Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Vulnerability Studies Under EMP: Impedance and PCI Testing of the Grid Control Devices

Control devices such as inverters and generator controllers are critical for the stable operation of the power grid, especially for power stability control and power dispatch. However, the Electromagnetic Pulse (EMP) is a potential threat to electronic devices in modern power grids, therefore decreasing the power grid resilience and bringing unrecoverable damages to the devices. To reveal the impact mechanism of the EMP, impedance and Pulse Current Injection (PCI) testing is established to study the vulnerability of the grid control devices. The impedance of the grid control devices is accurately measured using impedance analyzers with different frequency ranges. Then the voltage and current responses are tested based on the PCI testing. The vulnerability experiments based on two grid control devices are carried out. And the comparison results reveal that most ports would be damaged under EC8, and some ports can survive under EC5 according to the calculated PCI response and cumulative energy. The results can provide a reference for the future design of control devices and the strategic resilience of power grids.

Qiu, Wei↗

Assessment of NuScale SMR Steam Heat Augmentation for Chemical Plant Decarbonization

Nearly 50% of the total energy consumed by the industrial sector in the United States is used to produce process steam with natural gas and coal-fired boilers1 . This project conducts a technoeconomic assessment of a NuScale Small Modular Reactor (SMR) coupled with a chemical plant as an Integrated Energy System (IES) where nuclear produces steam and electric power to meet the requirements of a large chemical plant. In a 2020 study, ORNL evaluated the feasibility of using advanced SMRs, including the NuScale design, to supply energy to the Eastman Chemical Plant. However, since that report was published, NuScale received NRC approval for its uprated 77 MWe design with 56% more power and has also introduced a high-temperature, high pressure, steam heat-augmentation system, a key focus of the new study. The new study also benefits from revised capital costs, a 10-day refueling outage time, reduced plant staffing, higher capacity factors, and a site boundary Emergency Planning Zone methodology. The study consists of a techno-economic assessment of two possible energy sources (nuclear and natural gas) in a number of steam and power generation configurations (NuScale Power Modules (NPMs), boilers and combinations of both) to satisfy the steam and power demand with the most reliable and cost competitive system. A total of 2,947.3 klb/hr of steam and 72.5 MWe of electricity are required for the demonstration case. A range of scenarios and solutions are explored, from a 12-NPM plant (3,000 MWth)—with excess capacity and redundancy, capable of supplying a significant amount of extra power to the grid—to a 4-NPM (1,000 MWth) plant—supplemented with existing boilers or grid power for redundancy. The study uses historical steam and power data from a chemical plant and examines the sensitivity to natural gas and grid power cost variations. Scenarios with up to two times gas and electricity costs were considered. Profitability in a 60-year time horizon was analyzed, consistent with NuScale’s design life specification. A steady-state site integration and reliability analysis was performed, and trade-offs were identified.

20 FOSSIL-FUELED POWER PLANTS↗

Using distributed power electronics-based devices to improve the voltage and frequency stability of distribution systems

Methods include, in response to a line frequency variation of a power grid, adjusting a voltage setpoint of a voltage regulator coupled to the power grid at a grid edge to maintain a voltage at the grid edge, wherein the adjusting the regulated voltage setpoint is configured to reduce the line frequency variation to stabilize the line frequency of the power grid. Apparatus include a voltage regulator configured to couple to a power grid at a grid edge and to maintain a voltage at the grid edge, wherein the voltage regulator is further configured to adjust a voltage setpoint of a voltage regulator in response to a line frequency variation of the power grid to reduce the line frequency variation and stabilize the line frequency of the power grid.

Du, Wei↗

Bulk Power System Dynamics with Varying Levels of Synchronous Generators and Grid-Forming Power Inverters

Inverters using phase-locked loops for control depend on voltages generated by synchronous machines to operate. This might be problematic if much of the conventional generation fleet is displaced by inverters. To solve this problem, grid-forming control for inverters has been proposed as being capable of autonomously regulating grid voltages and frequency. Presently, the performance of bulk power systems with massive penetration of grid-forming inverters has not been thoroughly studied as to elucidate benefits. Hence, this paper presents inverter models with two grid-forming strategies: virtual oscillator control and droop control. The two models are specifically developed to be used in positive-sequence simulation packages and have been implemented in PSLF. The implementations are used to study the performance of bulk power grids incorporating inverters with gridforming capability. Specifically, simulations are conducted on a modified IEEE 39-bus test system and the microWECC test system with varying levels of synchronous and inverter-based generation. The dynamic performance of the tested systems with gridforming inverters during contingency events is better than cases with only synchronous generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-fluid, earth battery energy systems and methods

The present disclosure relates to a system for storing and time shifting at least one of excess electrical power from an electrical power grid, excess electrical power from the power plant itself, or heat from a heat generating source, in the form of pressure and heat, for future use in assisting with a production of electricity. An oxy-combustion furnace is powered by a combustible fuel source, plus excess electricity, during a charge operation to heat a reservoir system containing a quantity of a thermal storage medium. During a discharge operation, a discharge subsystem has a heat exchanger which receives heated CO 2 from the reservoir system and uses this to heat a quantity of high-pressure, supercritical CO 2 (sCO 2 ) to form very-high-temperature, high-pressure sCO 2 at a first output thereof. The very-high-temperature, high-pressure sCO 2 is used to drive a Brayton-cycle turbine, which generates electricity at a first output thereof for transmission to a power grid. The Brayton-cycle turbine also outputs a quantity of sCO 2 which is reduced in temperature and pressure to a heat recuperator subsystem. The heat recuperator subsystem circulates the sCO 2 and re-heats and re-pressurizes the sCO 2 before feeding it back to the heat exchanger to be even further reheated, and then output to the Brayton-cycle turbine as a new quantity of very-high-temperature, high-pressure sCO 2 , to assist in powering the Brayton-cycle turbine.

Buschek, Thomas A.↗

Analyzing Residential Charging Demand for Light-Duty Electric Vehicles in Colorado: Preprint

The past decade has witnessed the rapid adoption of electric vehicles (EVs). The momentum is expected to continue with strong support from the government and industry. Rapid EV adoption brings significant charging demand to the power grid, causing additional stress and non-negligible risks to the already-aging power grid. To help power grid operators understand the impacts of EV home charging on the grid and identify risk factors, this study presents a data-driven residential charging demand analysis for light-duty vehicles. This study considers two real-world grid service regions in Colorado and merges multiple data sources and state-of-the-art tools that characterize EV adoption projections, vehicle travel patterns, seasonal variations, residential charging accessibility, ambient temperature impact, EV charging behaviors, grid utility customers, vehicle registration, and household-level EV charging demand distribution. We characterize potential residential charging demand in 2030 for two regions within the state of Colorado: Boulder and Aurora. We project that EVs will be 26% of the light-duty vehicle population in Boulder and 16% in Aurora. Charging demand is characterized for ten power grid feeders (five for each study region). Across the ten feeders, peak total EV charging powers during wintertime range from less than 1 MW to more than 4 MW.

ADVANCED PROPULSION SYSTEMS↗

A Review on Artificial Intelligence for Grid Stability Assessment

Artificial intelligence provides a convenient route for power grid stability assessment. Compared with simulation-based approaches, artificial intelligence can potentially save time on model development and numerical computation in stability assessment. This paper first reviewed existing literature on using artificial intelligence for power grid stability assessment. Then a machine-leaning-based tool is presented and developed to assess power grid transient stability, frequency stability, and small signals stability. Test results verified the accuracy and effectiveness of the AI tool for power grid stability assessment.

You, Shutang↗

Hydropower Flexibility and Environmental Tradeoffs Analysis

The importance of hydropower increases as the power grid evolves with the higher variable renewable contribution. As conventional thermal power plants are retired, the importance of hydropower contribution increases to balance the variability of solar and wind generation. However, reservoir water resources are constrained by multiple constraints, and variability of water inflow to the reservoirs creates limitations to dam water releases for power grid needs. Coordinating multiple tools, including water resources, ecological, and technical and economic power grid modeling, informs dam water releases. The case study, the Columbia River Basin multipurpose reservoir project, is operated for hydropower production and many other purposes considering the aquatic habitat of the river basin. Specifically, the river basin fish population is a vital element for the tribal community of the river basin. We integrated a production cost model, a water resource model, and decades of tribal knowledge to analyze the fish-friendly way of operating Columbia hydropower scheduling and grid impacts. We measure power grid impacts for various water resources planning scenarios in terms of total system operating cost, system reliability indicators, changes in wind and solar generation and curtailments, local marginal prices, and revenue for hydropower producers. The study results inform reservoir operating rules decisions from hydropower power producers, system operators, other water users, tribes, environmentalists, and other stakeholders.

Columbia River↗

Efficient Network Partitioning: Application for Decentralized State Estimation in Power Distribution Grids: Preprint

Increase in the proliferation of DERs requires real-time situational awareness for efficient grid operations. State estimation plays an important role for real time control and management of the power grid. As the sensing infrastructure grows, aggregating and handling high volumes of data at a centralized location is extremely difficult. To address this challenge, this paper first proposes a novel and efficient hierarchical spectral clustering-based network partition algorithm followed by a decentralized compressive sensing (DCS) based state estimation. The applicability of the proposed network partitioning algorithm is tested on IEEE-123 bus, IEEE-8500 node, and a 6204-node distribution network. The results shows that the proposed approach efficiently divides the network into multiple sub-networks with the minimum edge connections among the neighbors. Then, we perform DCS-based state estimation on the 6204-node distribution network after dividing the network into 18 optimal partitions. Simulation results show that DCS-based state estimation recovers the system states with high accuracy and low complexity.

ADMM↗

Efficient Network Partitioning: Application for Decentralized State Estimation in Power Distribution Grids

Increase in the proliferation of distributed energy resources require real-time situational awareness for efficient grid operations. State estimation plays an important role for the real-time control and management of the power grid. As the sensing infrastructure grows, aggregating and handling high volumes of data at a centralized location is extremely difficult. To address this challenge, this paper first proposes a novel and efficient hier-archical spectral clustering-based network partitioning algorithm followed by a decentralized compressive sensing (DCS)-based state estimation. The applicability of the proposed network partitioning algorithm is tested on an IEEE 123-bus network, an IEEE 8,500-node system, and a 6,000+ node distribution network. The results shows that the proposed approach efficiently divides the network into multiple sub-networks with the minimum number of edge connections among the neighbors. Then, we perform DCS-based state estimation on the 6,000+ node distribution network after dividing the network into 18 optimal partitions. Simulation results show that the DCS-based state estimation recovers the system states with high accuracy and low complexity.

alternating direction method of multipliers↗

AI-Based Faster-Than-Real-Time Stability Assessment of Large Power Systems with Applications on WECC System

Achieving clean energy goals will require significant advances in regard to addressing the computational needs for next-generation renewable-dominated power grids. One critical obstacle that lies in the way of transitioning today’s power grid to a renewable-dominated power grid is the lack of a faster-than-real-time stability assessment technology for operating a fast-changing power grid. This paper proposes an artificial intelligence (AI) -based method that predicts the system’s stability margin information (e.g., the frequency nadir in the frequency stability assessment and the critical clearing time (CCT) value in the transient stability assessment) directly from the system operating conditions without performing the conventional time-consuming time-domain simulations over detailed dynamic models. Since the AI method shifts the majority of the computational burden to offline training, the online evaluation is extremely fast. This paper has tested the AI-based stability assessment method using multiple dispatch cases that are converted and tuned from actual dispatch cases of the Western Electricity Coordinating Council (WECC) system model with more than 20,000 buses. The results show that the AI-based method could accurately predict the stability margin of such a large power system in less than 0.2 milliseconds using the offline-trained AI agent. Therefore, the proposed method has great potential to achieve faster-than-real-time stability assessment for practical large power systems while preserving sufficient accuracy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

2024.03.13 Bushing Subcommittee presentation on Transformer Bushing Seismic Resilience: Design, Hazard, & Prevention Analysis [Slides]

Presents results from power grid simulations on synthetic grids that estimate the impact from power transformer failures due to earthquakes. In the best-case scenario, there is an 82.9% likelihood of load loss greater or equal to 51 MW. Methodologies are described as well as path forward to improving transformer resilience and, consequently, the resilience of the bulk power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Penetration Power Electronics Grid: Modeling and Simulation Gap Analysis

Increased penetration of power electronics in the grid is happening through development of high-power drives (like in Type 3 or 4 wind turbines, industrial drives, etc.), high-voltage direct current (HVdc) systems, flexible alternating current transmission systems (FACTS), energy storage systems (ESSs), inverter-based renewables like solar and wind, electric vehicle chargers, and other technologies. Ongoing research and development in new power electronic technologies including, but not limited to, solid-state power substations (SSPS), extreme fast charging (XFC), solid-state transformers, and multi-port power electronics that integrate multiple sources/loads will further increase penetration levels. To ensure stakeholders can integrate high penetration of power electronic technologies safely and reliably requires tools and methods to assess and evaluate their impact on the grid. Objectives: This report surveys, assesses, and analyzes commercially available and open-source tools that can support the assessment and evaluation of power electronics in future grids with high penetration levels. The study includes aspects that range from power flow analysis to dynamics evaluation (including hardware-in-the-loop – HIL testing) for such systems. The challenges and gaps associated with the current generation of toolsets available to assess the technical impact of introducing high penetration of power electronics are reported. The method is summarized in Figure ES-1.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control and Management of Multiple Converters in a Residential Smart Grid

Power electronic systems are becoming a staple building block for electric grid networks. However, these systems have been largely designed to grid integrate in ad hoc configurations with little or no coordination of control. This work proposes a central controller and power electronic system hardware and software design for a residential system (photovoltaic, energy storage and residential building). This system supports auto-integration, plug and play capabilities, and optimal energy management to meet different use cases. Modelling and multi-day testing of the system have been conducted in a controller hardware-in-the-loop (C-HIL) testbed. Multiple use cases and pricing options have been considered as part of the simulation and testing. Results are presented of these systems as a proof of principle.

Starke, Michael↗

Passive cooling designs to improve heat resilience of homes in underserved and vulnerable communities

Disadvantaged communities face a growing threat to staying safe during heat waves, especially during coincident power outages. This study develops a methodology to evaluate the effectiveness of passive cooling measures (those that operate without power) to improve residential building heat resilience. Building performance is simulated for representative homes and on district scales in two disadvantaged communities in Fresno, California. Eleven passive measures are evaluated using four heat resilience metrics with and without grid power. Results show performance of the mitigation measures varies by building characteristics, surrounding environment, and power scenario. The two most effective measures were installing solar-control window films and adding roof insulation. For pre-1978 single-family homes, these two measures can reduce unmet degree-hours (UDH) indoors by 12% and 11% respectively without grid power, or 28% and 37% with grid power. Their respective UDH reductions at district scale typically range 8% — 20% and 4% — 12% without grid power, or 14% — 44% and 8% — 51% with grid power. Top floors have higher overheating risk than lower floors during extreme heat events with coincident power outages. Natural ventilation can help, reducing UDH by 21% — 26%. The methodology and findings from this study can help cities, communities, and utilities develop effective and targeted strategies to promote greater residential heat resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Plug-and-Play Design Suite of Converters for the Electric Grid

Power electronic (PE) systems are increasingly being integrated into the electric grid in a distributed fashion. As the number of installations increases, the challenge of integration of these systems into the grid is also growing. Advanced control features of these systems are often overlooked or neglected due to the complex nature and novelty of these systems. This is also complicated from the vendor point of view as different converter topology integration is usually composed of single system designs with tight coupling and configurations. The presented work discusses a novel architecture for the integration of PE systems with other sources and loads to create a coordinated controllable resource for the grid. The presented work also describes a system level controller to coordinate these systems. 1 Testing results on a hardware in the loop (HIL) platform are provided to show the validity of the proposed architecture and framework.

Starke, Michael↗

Deadband Voltage Control and Power Buffering for Extreme Fast Charging Station

Voltage fluctuation is one of the most common challenges that electric vehicle charging station (EVCS) may introduce to the power grid. Local reactive power compensation (Q-compensation) capability of bi-directional electric vehicle (EV) chargers can mitigate the steady-state voltage violations caused by the EV charging itself or changes in the neighboring loads. Power buffering, using energy storage system (ESS), can be utilized to address the voltage transients (sags and swells) as a result of EV charging at the EVCS. To address PI controller’s ‘hunting’ issue, this paper proposes a Q-sign triggered deadband voltage control (V-control) method at the point of common coupling (PCC). In addition, to ensure the ramp rate of EV charging is within the allowable limits set forth by the grid code, a ramp rate control is proposed that uses the ESS as a ‘power buffer’. Lastly, different from most reported work in the literature where no explicit limit of the power electronic converters (PECs) is considered, this work considers a reasonable apparent power capacity limit of the PECs when achieving the V-control. This limit also affects the amount of active power that can be obtained from the grid, and subsequently may require ESS to function as ‘load sharing’ device to provide supplemental active power to satisfy EV load. A case study simulated in MATLAB (interfaced with PLECS) is presented to demonstrate the effectiveness of the proposed approaches for EVCS operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗