UNH TDP - Concurrent Measurements of Inflow, Power Performance, and Loads for a Grid-Synchronized Vertical Axis Cross-Flow Turbine Operating in a Tidal Estuary

This data was collected between October 12 and December 15 of 2021 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). This data set includes over 29 days of grid connected turbine operation during this 65 day time frame. The priority for this measurement campaign was to collect data while the turbine was electrically connected to the grid by means of a rectifier and inverter. The Fall_2021_UNH_Measurement_Timeline.png highlights when each instrument was functioning and the Fall_2021_UNH_Test_Log.jpg indicates the four main regions for analysis available from this measurement campaign. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal forcing with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Kaelin Chancey (Assessment Of The Localized Flow And Tidal Energy Conversion System At An Estuarine Bridge - UNH MS Thesis 2019). The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. This project was pursued to quantify device performance for cross flow turbines operating in a marine environment. Accurate physical models, to characterize cross flow turbine performance, require real operational data sets due to the complexity of blade fluid interactions. This data can help support model development which will help predict turbine performance when analyzing perspective project locations in the future. Instrumentation was deployed to measure; water speed/direction, electrical power output, turbine shaft speed, turbine thrust force, and platform motion. Concurrent measurements of these parameters allow for correlations (cause and affect) to be inferred, allowing for characterization of device performance over a range of operating conditions. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) directly upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier and the Shark power meter. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. This submission includes zipped folders for each instrument containing quality controlled (QC'd) data in daily .csv files for the relevant duration specific to each instrument, along with separate .csv file that contains the units for each variable. Some instrument daily files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. Note the degree of QC varied between each instrument due to time constraints. Particular time and attention was given to perform quality control tests on the acoustic based instruments that are particularly suscep...

16 TIDAL AND WAVE POWER↗

Considerations for high accuracy radiation efficiency measurements for the Solar Power Satellite (SPS) subarrays

The relatively large apertures to be used in SPS, small half-power beamwidths, and the desire to accurately quantify antenna performance dictate the requirement for specialized measurements techniques. Objectives include the following: (1) For 10-meter square subarray panels, quantify considerations for measuring power in the transmit beam and radiation efficiency to + or - 1 percent (+ or - 0.04 dB) accuracy. (2) Evaluate measurement performance potential of far-field elevated and ground reflection ranges and near-field techniques. (3) Identify the state-of-the-art of critical components and/or unique facilities required. (4) Perform relative cost, complexity and performance tradeoffs for techniques capable of achieving accuracy objectives. the precision required by the techniques discussed below are not obtained by current methods which are capable of + or - 10 percent (+ or - dB) performance. In virtually every area associated with these planned measurements, advances in state-of-the-art are required.

Kozakoff, D. J.↗

Unveiling the Nature of Soft Gamma Repeaters and Magnetars: Scientists Measure the Most Powerful Magnet Known

This newsletter from NASA Goddard Space Flight Center (GSFC) announces measurements of the magnetic field of a magnetar. The magnetic field was approx. 10(exp 15) gauss, up to 10 times more powerful than previous estimates. The newsletter also describes how the star's magnetic field slows its rotation, and how starquakes emit protons, which are trapped in this neutron star's magnetic field, and make it a soft gamma repeater (SGR).

Swank, Jean↗

Experimental measurement of structural power flow on an aircraft fuselage

An experimental technique is used to measure structural intensity through an aircraft fuselage with an excitation load applied near one of the wing attachment locations. The fuselage is a relatively large structure, requiring a large number of measurement locations to analyze the whole of the structure. For the measurement of structural intensity, multiple point measurements are necessary at every location of interest. A tradeoff is therefore required between the number of measurement transducers, the mounting of these transducers, and the accuracy of the measurements. Using four transducers mounted on a bakelite platform, structural intensity vectors are measured at locations distributed throughout the fuselage. To minimize the errors associated with using the four transducer technique, the measurement locations are selected to be away from bulkheads and stiffeners. Furthermore, to eliminate phase errors between the four transducer measurements, two sets of data are collected for each position, with the orientation of the platform with the four transducers rotated by 180 degrees and an average taken between the two sets of data. The results of these measurements together with a discussion of the suitability of the approach for measuring structural intensity on a real structure are presented.

Cuschieri, J. M.↗

A fiber-coupled dispersion interferometer for density measurements of pulsed power transmission line electron sheaths on Sandia’s Z machine

A fiber-coupled Dispersion Interferometer (DI) is being developed to measure the electron density of plasmas formed in power flow regions, such as magnetically insulated transmission lines, on Sandia National Laboratories (SNL’s) Z machine [D. B. Sinars et al., Phys. Plasmas 27, 070501 (2020)]. The diagnostic operates using a fiber-coupled 1550 nm CW laser with frequency-doubling to 775 nm. The DI is expected to be capable of line-average density measurements between ∼1013 and 1019 cm−2. Initial testing has been performed on a well-characterized RF lab plasma [A. G. Lynn et al., Rev. Sci. Instrum. 80, 103501 (2009)] at the University of New Mexico to quantify the density resolution lower limits of the DI. Initial testing of the DI has demonstrated line-average electron density measurements within 9% of results acquired via a 94 GHz mm wave interferometer for line densities of ∼1 × 1014 cm−2, despite significant differences in probe beam geometries. The instrument will next be utilized for measurements on a ∼1 MA-scale pulsed power driver {MYKONOS [N. Bennett et al., Phys. Rev. Accel. Beams 22, 120401 (2019)] at SNL} before finally being deployed on SNL’s Z machine. The close electrode spacing (mm scale) on Z requires probe beam sizes of ∼1 mm, which can only be obtained with visible or near infrared optical systems, as opposed to longer wavelength mm wave systems that would normally be chosen for this range of density.

Hines, N. R. (ORCID:0000000315316465)↗

Simulated Versus Measured UHF Radiated Power at LaRC Street Level

The Airspace Operations and Safety Program, System-Wide Safety Project /Technical Challenge 2 – Emerging Operations at NASA Langley aims to increase the flight safety of unmanned aerial vehicles (UAV’s) by informing UAV operators of regions of airspace where the radio frequency (RF) power at designated frequencies exceeds threshold values, indicating possible damage or interference with on-board systems. WinProp electromagnetic simulation software, a commercially available ray tracing program, has been implemented to predict radiated power from known RF sources. As a test case, the NextNav geolocation system, with nine transmitters operating at 926.227 MHz, was selected and modeled together with other existing structures at Langley. The radiated power at street level was calculated and compared with measurements taken at street level by a Signal Hound receiver and an Electro-Metrics antenna mounted on a van. The two sets of results generally agreed to within about 5 dB.

electromagnetic simulation↗

The Atacama Cosmology Telescope: A Measurement of the Primordial Power Spectrum

We present constraints on the primordial power spectrum of adiabatic fluctuations using data from the 2008 Southern Survey of the Atacama Cosmology Telescope (ACT). The angular resolution of ACT provides sensitivity to scales beyond l = 1000 for resolution of multiple peaks in the primordial temperature power spectrum, which enables us to probe the primordial power spectrum of adiabatic scalar perturbations with wavenumbers up to k approx. = 0.2 Mp/c. We find no evidence for deviation from power-law fluctuations over two decades in scale. Matter fluctuations inferred from the primordial temperature power spectrum evolve over cosmic time and can be used to predict the matter power spectrum at late times; we illustrate the overlap of the matter power inferred from CMB measurements (which probe the power spectrum in thc linear regime) with existing probes of galaxy clustering, cluster abundances and weak lensing constraints on the primordial power. This highlights the range of scales probed by current measurement.s of the matter power spectrum.

Hlozek, Renee↗

Characterizing Interference in a Wave-Powered Buoy

Oceanographic measurement buoys are power constrained by the capacity of their batteries and the available solar power. Many buoys are in locations with abundant wave energy, but wave energy converters are not being used to power them. One reason wave energy converters may not have not been developed for wave measurement buoys is that many buoys measure waves by precisely following the wave motion. Wave energy converters may inhibit this wave-following ability by altering a buoy's response to incoming waves. In this report, we present the results of field tests that measured the extent to which buoy motion was changed by modifications to the buoy for wave energy harvesting. The motion of the buoy was significantly modified by the addition of the hardware components necessary for harvesting wave energy. The ratio of the mass of the wave energy converter to the mass of the buoy was high for the system tested, which strongly affected buoy motion. A lower value for this ratio would decrease the effect of the wave energy converter on the motion of the buoy, thereby decreasing the impact on the buoy's ability to measure waves but also decreasing the power production capabilities. Therefore, the use of wave energy converters to power wave measurement buoys may be feasible for large buoys that measure low-frequency waves and have low power requirements.

16 TIDAL AND WAVE POWER↗

Precise synchronization of phasor measurements in electric power systems

Phasors representing positive sequence voltages and currents in a power network are in the most important parameters in several monitoring, control, and protection functions in interconnected electric power networks. Recent advances in computer relaying have led to very efficient and accurate phasor measurement systems. When the phasors to be measured are separated by hundreds of miles, it becomes necessary to synchronize the measurement processes, so that a consistent description of the state of the power system can be established. Global Positioning System (GPS) transmissions offer an ideal source for synchronization of phasor measurements. The concept and implementation of this technique are described. Several uses of synchronized phasor measurements are also described. Among these are improved state estimation algorithms, state estimator enhancements, dynamic state estimates, improved control techniques, and improved protection concepts.

Phadke, Arun G.↗

Improved L-C resonant decay technique for Q measurement of quasilinear power inductors: New results for MPP and ferrite powdered cores

The L-C resonant decay technique for measuring circuit Q or losses is improved by eliminating the switch from the inductor-capacitor loop. A MOSFET switch is used instead to momentarily connect the resonant circuit to an existing voltage source, which itself is gated off during the decay transient. Very reproducible, low duty cycle data could be taken this way over a dynamic voltage range of at least 10:1. Circuit Q is computed from a polynomial fit to the sequence of the decaying voltage maxima. This method was applied to measure the losses at 60 kHz in inductors having loose powder cores of moly permalloy and an Mn-Zn power ferrite. After the copper and capacitor losses are separated out, the resulting specific core loss is shown to be roughly as expected for the MPP powder, but anomalously high for the ferrite powder. Possible causes are mentioned.

Niedra, Janis M.↗

SPT-3G D1: A Measurement of Secondary Cosmic Microwave Background Anisotropy Power

We report new measurements of millimeter-wave temperature power spectra in the angular multipole range $1700 \le \ell \le 11,000$ (wavelengths $13^\prime \gtrsim λ\gtrsim 2^\prime$). We use two years of data in three observing bands centered near 95, 150, and 220 GHz from the SPT-3G receiver on the South Pole Telescope that cover a 1646 deg$^2$ region of the Southern sky. Using the measured power spectra, we present constraints on the thermal and kinematic Sunyaev-Zel'dovich (SZ) effects, radio galaxies, and cosmic infrared background (CIB). We find that inferred SZ powers are dependent on the detailed modeling of the thermal SZ-CIB correlation, and to a lesser extent on the assumed angular dependence of the SZ spectra. We report constraints for simulation-based model templates as well as fits where the angular dependencies of the SZ and CIB power spectra are allowed to vary. In the latter case at $\ell=3000$, we find thermal SZ power at 143 GHz of $D_{3000}^{\rm tSZ} = 4.91\pm0.37\, μ{\rm K}^2$ and kinematic SZ power of $D_{3000}^{\rm kSZ} =1.75\pm0.86\, μ{\rm K}^2$. We use the measured kinematic SZ power to estimate the duration of reionization, noting that the reionization inferences are sensitive to the model choices and assumed level of homogeneous kinematic SZ power from the late-time universe. We find a 95% limit on the duration from an ionization fraction of 25% to 75% of $Δ^{50} z_{\rm re} <\,3.8$ based on a semi-analytic model, or a limit on the duration from an ionization fraction of 5% to 95% of $Δ^{90} z_{\rm re} <\,6.1$ based on the AMBER simulations.

Chaubal, P. [Melbourne U.]↗

Measurement of the CMB temperature power spectrum and constraints on cosmology from the SPT-3G 2018 T T , T E , and E E dataset

We present a sample-variance-limited measurement of the temperature power spectrum ( T T ) of the cosmic microwave background using observations of a ∼ 1500 deg 2 field made by the SPT-3G in 2018. We report multifrequency power spectrum measurements at 95, 150, and 220 GHz covering the angular multipole range 750 ≤ ℓ < 3000 . We combine this T T measurement with the published polarization power spectrum measurements from the 2018 observing season and update their associated covariance matrix to complete the SPT-3G 2018 T T / T E / E E dataset. This is the first analysis to present cosmological constraints from SPT T T , T E , and E E power spectrum measurements jointly. We blind the cosmological results and subject the dataset to a series of consistency tests at the power spectrum and parameter level. We find excellent agreement between frequencies and spectrum types and our results are robust to the modeling of astrophysical foregrounds. We report results for Λ CDM and a series of extensions, drawing on the following parameters: the amplitude of the gravitational lensing effect on primary power spectra A L , the effective number of neutrino species N eff , the primordial helium abundance Y P , and the baryon clumping factor due to primordial magnetic fields b . We find that the SPT-3G 2018 T T / T E / E E data are well fit by Λ CDM with a probability to exceed of 15%. For Λ CDM , we constrain the expansion rate today to H 0 = 68.3 ± 1.5 km s - 1 Mpc - 1 and the combined structure growth parameter to S 8 = 0.797 ± 0.042 . The SPT-based results are effectively independent of Planck, and the cosmological parameter constraints from either dataset are within < 1 σ of each other. The addition of temperature data to the SPT-3G T E / E E power spectra improves constraints by 8–27% for each of the Λ CDM cosmological parameters. When additionally fitting A L , N eff , or N eff + Y P , the posteriors of these parameters tighten by 5–24%. In the case of primordial magnetic fields, complete T T / T E / E E power spectrum measurements are necessary to break the degeneracy between b and n s , the spectral index of primordial density perturbations. We report a 95% confidence upper limit from SPT-3G data of b < 1.0 . The cosmological constraints in this work are the tightest from SPT primary power spectrum measurements to date and the analysis forms a new framework for future SPT analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Power meter for optical efficiency measurements of laser-induced plasmas

A power meter was constructed to measure the power being deposited in transient laser-induced plasmas (LIP). The design rejects the radiation scattered from the laser beam by the LIP and that transmitted past the LIP. The power meter is constructed from a small metal-capped flask placed in an evacuated chamber. The steady-state heat production in the flask is determined from measurements of the temperature gradient on a thermal resistance connecting the top of the flask with a heat sink. The design worked well and should be applicable to a wide variety of situations if the dimensions of the system are adjusted to compensate for power levels substantially different from those used here.

Borucki, William J.↗

Performance of plane wavefront Fizeau interferometers in power spectral density measurements with tilted plane optics

Binary pseudo-random array (BPRA) test samples are useful devices for calibrating the instrument transfer function (ITF) of Fizeau interferometers, interferometric microscopes, and other optical and non-optical surface and wavefront metrology instruments. The intrinsic white noise character of the power spectral density (PSD) function of the BPRA pattern simplifies the extraction of the ITF from the measured PSD. The ITF determined in a dedicated calibration experiment can be used to reconstruct the surface height profile from the measured data, effectively enhancing the instrument’s spatial resolution. For a high confidence reconstruction procedure, a reliable analytical model of the IFT is desirable. Usually, the model accounts for the contributions to the ITF related the imperfections of the instrument’s optical and detector systems. Here, we experimentally demonstrate that in the case of surface height metrology with Fizeau interferometers, the PSD measurements and, therefore, the efficacy of the ITF calibration of the tool, are strongly affected by the instrument data acquisition and processing procedures, as well as by the shape of the optic under test and its alignment with respect to the interferometer.

Yashchuk, V V↗

Model-Free Building Temperature Control and Power Allocation Under Measurement Time Delays

Taking a step towards a greener planet has created an increased need for a higher integration of renewable energy resources into the electric grid. Nonetheless, the intermittency and uncertainty associated with renewable generation have slowed down this integration. Demand response (DR) has been recently adopted to address this challenge by utilizing demand side flexibility and enabling the participation of many grid-interactive efficient buildings (GEBs). However, existing DR methods require significant modeling and/or training efforts and are computationally expensive. To address the aforementioned issues, we propose a model-free control (MFC)-based strategy that is robust to the time delays in the temperature measurements of the thermostatically controlled loads (TCLs). It assigns to each GEB a local controller to maintain the TCLs’ temperatures within desired comfort levels, while the load aggregator (LA) allocates the assigned reference power provided by the distribution system operator (DSO) to support a specific grid service, such as demand peak reduction, load shifting, balancing supply and demand, and consuming the solar photovoltaic power locally. We investigate the effects of such loss of information on the local control action as well as on meeting the power allocation constraint. We conclude that, for an appropriate choice of design parameters, the proposed MFC controller is satisfactorily robust to measurement time delays.

Telsang, Bhagyashri↗

Drifting Acoustic Measurements around C-Power's SeaRay WEC

The repository contains underwater noise measurements and associated metadata collected around C-Power's SeaRay wave energy converter on July 15, 2024 and July 16, 2024 while it was deployed at the U.S. Navy's Wave Energy Test Site (WETS) in Kaneohe, HI. Measurements were obtained using Drifting Acoustic Instrumentation SYstems (DAISYs). DAISYs consist of a surface expression connected to a hydrophone recording package by a tether. Both elements are instrumented to provide metadata (e.g., position, orientation, and depth). Information about how to build DAISYs is available at https://www.pmec.us/research-projects/daisy. The repository's primary content is a compressed archive (.zip format), containing multiple MATLAB binary data files (.mat format). The structure of each file is included in the repository as a Word document (Data Description MHK-DR.docx). Each file contains time series information for a single DAISY deployment (file naming convention: WETS_DAISY_[Drift #].mat) consisting of processed hydrophone data and associated metadata. During these measurements, C-Power's SeaRay was located at approximately 21.48112 N, 157.74451 W.

16 TIDAL AND WAVE POWER↗

Predicted and Measured Modal Sound Power Levels for a Fan Ingesting Distorted Inflow

Refinements have been made to a method for estimating the modal sound power levels of a ducted fan ingesting distorted inflow. By assuming that each propagating circumferential mode consists only of a single radial mode (the one with the highest cut-off ratio), circumferential mode sound power levels can be computed for a variety of inflow distortion patterns and operating speeds. Predictions from the refined theory have been compared to data from an experiment conducted in the Advanced Noise Control Fan at NASA Glenn Research Center. The inflow to the fan was distorted by inserting cylindrical rods radially into the inlet duct. The rods were placed at an axial location one rotor chord length upstream of the fan and arranged in both regular and irregular circumferential patterns. The fan was operated at 2000, 1800, and 1400 rpm. Acoustic pressure levels were measured in the fan inlet and exhaust ducts using the Rotating Rake fan mode measurement system. Far field sound pressure levels were also measured. It is shown that predicted trends in circumferential mode sound power levels closely match the experimental data for all operating speeds and distortion configurations tested. Insight gained through this work is being used to develop more advanced tools for predicting fan inflow distortion tone noise levels.

Koch, L. Danielle↗

Offline Power Systems Applications Enabled by Phasor Measurement Units: Technical Assistance to the Power Sectors of Southeast Asia

This report provides a brief overview of several offline (non-real-time) applications facilitated by high-resolution time-synchronized measurements recorded by phasor measurement units (PMUs). The high reporting rate and time-synchronization of PMU records provide a detailed view of power system dynamics, enabling electric utilities to obtain a better understanding of their systems. In this report, the following applications have been reviewed: Power plant model validation, System model validation, Ringdown oscillation analysis, Frequency response analysis, Postmortem analysis of disturbance events Along with a brief technical background of the applications above, applicable North American Electric Reliability Corporation (NERC) standards have been discussed, and examples of implementation in North American organizations have been provided. Implementing several of the discussed applications may need a preliminary stage of data gathering from multiple entities, and several frameworks and process flows have been formulated by organizations around the world for this purpose. However, the data-gathering stage has not been considered in the scope of the present report.