Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A maximum correlation method for image construction of IRAS survey data

An algorithm is presented for the construction of images using linear array data with nonuniform scan coverage of object space and nonuniform detector responses. The algorithm achieves the maximum correlation between adjacent pixels, i.e., the smoothest image, consistent with the data and data uncertainties. For high spatial data density and signal-to-noise ratio, the achievable spatial resolution can exceed the diffraction limit of the optics. The capability of the algorithm is illustrated using 60-micron data from the region centered on the galaxy M101, obtained during the all-sky survey performed by the Infrared Astronomical Satellite. The 60-micron map produced has a resolution of about 36 arcsec and allows the identification of many H II regions by position and aperture photometry for the brighter ones. The achieved resolution is discussed in terms of the a priori estimate of the mean correlation length of the data, the directly measured FWHM in the final image, and the results of aperture photometry of M101 H II regions NGC 5447, 5455, 5461, 5462 and 5471.

Aumann, H. H.↗

The exciting young stellar object for the molecular outflow at the core of L1287

Using IR imaging, we demonstrate that a bipolar reflection nebula is associated with the nebula GN 00.33.9 at the core of the dark cloud L1287, and that these bipolar extensions are oriented with the molecular gas outflow lobes in this region. The polarization patterns in the high-resolution polarimetric maps indicate that the position of the primary source of illumination for these bipolar dust features lies to the north of both RNO 1B and RNO 1C. No NIR point source appears at the position in the images. In addition, the colors in the reflection nebulosity suggest the illuminating source is redder than either RNO 1B or RNO 1C. We suggest, therefore, that a previously unidentified young stellar object (YSO) is probably the driving source of the outflow. As the nominal position of IRAS 00338+6312 lies within 1.5 arcsec of the position of this newly identified YSO, we suggest that these are the same object. The colors and wavelength-dependent polarization levels in the vicinity of RNO 1C are most consistent with RNO 1C being a protostellar source.

Weintraub, David A.↗

The Accuracy of Saccadic and Perceptual Decisions in Visual Search

Saccadic eye movements during search for a target embedded in noise are suboptimally guided by information about target location. Our goal is to compare the spatial information used to guide the saccades with that used for the perceptual decision. Three observers were asked to determine the location of a bright disk (diameter = 21 min) in white noise (signal-to-noise ratio = 4.2) from among 10 possible locations evenly spaced at 5.9 deg eccentricity. In the first of four conditions, observers used natural eye movements. In the three remaining conditions, observers fixated a central cross at all times. The fixation conditions consisted of three different presentation times (100, 200, 300 msec), each followed by a mask. Eye-position data were collected, with a resolution of (approximately) 0.2 deg. In the natural viewing condition, we measured. the accuracy with respect to the target and the latency of the first saccade. In the fixation conditions, we discarded trials in which observers broke fixation. Perceptual performance was computed for all conditions. Averaged across observers, the first saccade was correct (closest to the target location) for 56 +/- (SD) % of trials (chance = 10 %) and occurred after a latency of 313 +/- 56 msec. Perceptual performance averaged 53 +/- 4, 63 +/- 4, 65 +/- 2 % correct at 100, 200, and 300 msec, respectively. For the signal-to-noise ratio used, at the time of initiation of the first saccade, there is little difference between the amount of information about target location available to the perceptual and saccadic systems.

Eckstein, Miguel P.↗

Taking a Position

"TerrAvoid" and "Position Integrity" combine Global Positioning Satellite (GPS) data with high-resolution maps of the Earth's topography. Dubbs & Severino, Inc., based in Irvine, California, has developed software that allows the system to be run on a battery-powered laptop in the cockpit. The packages, designed primarily for military sponsors and now positioned to hit the consumer market in coming months, came about as the result of the Jet Propulsion Laboratory's Technology Affiliates Program. Intended to give American industry assistance from NASA experts and to facilitate business use of intellectual property developed for the space program, the Technology Affiliates Program introduced the start-up company of Dubbs & Severino to JPL's Dr. Nevin Bryant four years ago. GeoTIFF is now in the public domain, and its use for commercial product development has evolved into an industry standard over the last year.

Source record↗

An Improved 360 Degree and Order Model of Venus Topography

We present an improved 360 degree and order spherical harmonic solution for Venus' topography. The new model uses the most recent set of Venus altimetry data with spacecraft positions derived from a recent high resolution gravity model. Geometric analysis indicates that the offset between the center of mass and center of figure of Venus is about 10 times smaller than that for the Earth, the Moon, or Mars. Statistical analyses confirm that the RMS topography follows a power law over the central part of the spectrum. Compared to the previous topography model, the new model is more highly correlated with Venus' harmonic gravity field.

Rappaport, Nicole J.↗

Low-resolution VLT Spectroscopy of GRBs 991216, 011211, 021211 and 030328

We present low-resolution VLT spectroscopy of the aftergiow position of the gamma ray bursts 991216, 011211, 021211 and 030328. The spectmm of GRB 991216 shows two probable absorption systems at z = 0.80 and z = 1.02, where the highest redshift most likely reflects the distance to the host galaxy. A third, more uncertain, system may be detected at z = 0.77. HST imaging of the field obtained 4 months later, show two amorphous regions of emission, one at the projected OT position, the presumed host galaxy at z = 1.02, and the other 0"6 away. All significant lines in the spectrum of GRB 011211 are identified with lines originating in a single absorption system at z = 2.142 plus or minus 0.002, the redshift of the GRB 011211 host galaxy. We also detect Lya in the host, for which we fit a neutral hydrogen column density of log N(HI)=20.4 plus or minus 0.2, which indicates that it is a damped Lya system. For GRB021211, we detect a single emission line in a spectrum tens of days after the burst, which we identify as [OII] at z = 1.006. The galaxy l"5 away from the afterglow location has z = 0.800, and is therefore unrelated to the GRB. Finally, for GRB030328 at least two absorption systems are required to explain all significant lines: one at z = 1.522, the likely redshift of the GRB, and the other at z = 1.295. For the latter system we only detect two lines, and we consider the reality of this system to be uncertain.

Vreeswijk, P. M.↗

Positions and Intensities in the 2v4/v1/v3 Vibrational System of 14NH3 near 3 mu m

Line positions and line intensities of the v1, v3 and 2V4 bands of 14NH3 were analyzed using line positions from 0.0054 cm-1 apodized resolution FT spectra recorded at Orsay and using line intensities from 0.011 cm-1 unapodized resolution FT spectra recorded at Kitt peak National Observatory. The theoretical model and the set of programs developed for treating the infrared system v1/v3/2v4 of ammonia are briefly discussed.

ammonia Jupiter infrared mapping↗

Models of Active Glacial Isostasy Roofing Warm Subduction: Case of the South Patagonian Ice Field

Modern geodetic techniques such as precise Global Positioning System (GPS) and high-resolution space gravity mapping (Gravity Recovery and Climate Experiment, GRACE) make it possible to measure the present-day rate of viscoelastic gravitational Earth response to present and past glacier mass changes. The Andes of Patagonia contain glacial environments of dramatic mass change. These mass load changes occur near a tectonically active boundary between the Antarctic and South American plates. The mechanical strength of the continental side of this boundary is influenced by Neogene ridge subduction and by the subduction of a youthful oceanic slab. A ridge of young volcanos parallels the Pacific coastline. Release of volatiles (such as water) at depth along this ridge creates a unique rheological environment. To assess the influence of this rheological ridge structure on the observational land uplift rate, we apply a two dimensional viscoelastic Earth model. A numerical study is presented which examines the sensitivity of the glacial loading-unloading response to the complex structure at depth related to the subducting slab, the viscous wedge between slab and continental lithosphere, and the increase of elastic thickness from oceanic to continental lithosphere. A key feature revealed by our numerical experiments is a continuum flow wherein the slab subdues the material transport toward oceanic mantle and crust. The restricted flow is sensitive to the details of slab mechanical strength and penetration into the upper mantle. The reduced viscosity within the mantle wedge, however, enhances the load-induced material transport everywhere within the asthenosphere.

crustal mass changes↗

An Improved 360 Degree and Order Model of Venus Topography

We present an improved 360 degree and order spherical harmonic solution for Venus' topography. The new model uses the most recent set of Venus altimetry data with spacecraft positions derived from a recent high resolution gravity model.

Venus↗

Mechanical Design Progress of the In Situ Nanoprobe Instrument for APS-U

The In Situ Nanoprobe (ISN, 19-ID) beamline will be a new best-in-class long beamline to be constructed as part of the Advanced Photon Source Upgrade (APS-U) project [1, 2]. To achieve long working distance at high spatial resolution, the ISN instrument will be positioned 210 m downstream of the x-ray source, in a dedicated satellite building, currently under construction [3]. The ISN instrument will use a nano-focusing Kirkpatrick-Baez (K-B) mirror system, which will focus hard x-rays to a focal spot as small as 20 nm, with a large working distance of 61 mm. The large working distance provides space for various in situ sample cells for x-ray fluorescence tomography and ptychographic 3D imaging, allows the use of a separate, independent vacuum chambers for the optics and sample, and provides the flexibility to run experiments in vacuum or at ambient pressure. A consequence of the small spot size and large working distance are stringent requirements for high angular stability of the K-B mirrors (5 nrad V-mirror and 16 nrad H-mirror) and high relative stability be-tween focus spot and sample (4 nmRMS). Additional features include fly-scanning up to 2 kg mass, sample plus in situ cell, at 1 mm/s in vertical and/or horizontal directions over an area of 10 mm x 10 mm. Environmental capabili-ties will include heating and cooling, flow of fluids and applied fields, as required for electrochemistry and flow of gases at high temperature for catalysis. To achieve these capabilities and precise requirements we have used precision engineering fundamentals to guide the design process.

Kearney, Steven P.↗

Subgrid resolution of flow and force fields.

By means of spline fitting, both while converting a Lagrangian distribution of field sources onto an Eulerian grid, and while interpolating the field from its Eulerian grid to the Lagrangian positions of the responding elements, one achieves effective resolution down to about one-eight of a grid mesh unit. One also avoids discontinuities and noise due to cell boundary crossings.

Buneman, O.↗

The JPL Field Emission Spectrometer

The Jet Propulsion Laboratory (JPL) Field Emission Spectrometer (FES) was built by Designs and Prototypes based on a set of functional requirements supplied by JPL. The instrument has a spectral resolution of 6 wavenumbers (wn) and can acquire spectra from either the Mid Infrared (3-5 mu m) or the Thermal Infrared (8-12 pm) depending on whether the InSb or HgCdTe detector is installed respectively. The instrument consists of an optical head system unit and battery. The optical head which is tripod mounted includes the interferometer and detector dewar assembly. Wavelength calibration of the interferometer is achieved using a Helium-Neon laser diode. The dewar needs replenishing with liquid Nitrogen approximately every four hours. The system unit includes the controls for operation and the computer used for acquiring viewing and processing spectra. Radiometric calibration is achieved with an external temperature-controlled blackbody that mounts on the fore-optics of the instrument. The blackbody can be set at 5 C increments between 10 and 55 C. The instrument is compact and weighs about 33 kg. Both the wavelength calibration and radiometric calibration of the instrument have been evaluated. The wavelength calibration was checked by comparison of the position of water features in a spectrum of the sky with their position in the output from a high resolution atmospheric model. The results indicatethat the features in the sky spectrum are within 6-8 wn of their position ill the model spectrum. The radiometric calibration was checked by first calibrating the instrument using the external blackbody supplied with the instrument and then measuring the radiance from another external blackbody at a series of temperatures. The temperatures of these radiance spectra were then recovered by inventing Planck's law and the recovered temperatures compared lo the measured blackbody temperature. These results indicate that radiometric calibration is good to 0.5 C over the range of temperatures 10 to 55 C. The results also indicate that the instrument drifts slowly over time and should be recalibrated every 20 to 30 minutes in the field to ensure good radiometric fidelity. The instrument has now been extensively tested in the field in the United States and Australia. These in situ field measurements are being used to validate emissivity spectra recovered from the Thermal Infrared Multispectral Scanner (TIMS) and also the Australian CO2 Laser. The availability of in situ measurements is proving crucial to validation of the spectra derived from the airborne instruments since many natural surfaces cannot be easily transported back to the laboratory.

Hook, Simon J.↗

Neutron Positioning and Geometric Distortion Correction on the SNS SiPM Anger Camera

Neutron Anger cameras are scintillator-based thermal neutron detectors that utilize pixelated photosensors to read out visible light signals and position neutrons accurately They are versatile detectors that can cover large areas for diffraction instruments and offer high efficiency and sub-millimeter spatial resolution. Photomultiplier Tube (PMT) based cameras are installed on three instruments at Spallation Neutron Source (SNS). The next generation camera uses Silicon Photomultipliers (SiPMs) instead of PMTs, which allows for a more compact design and higher spatial resolution. In this report, the Gaussian least-squares position fitting method is described in detail, as well as the method used to correct for geometric distortions across the face of the camera. Results from neutron camera tests before and after the distortion correction are shown and the spatial resolution is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-Ray Missions Based on LTD Technologies

Microcalorimeter arrays used as imaging spectrometers will enable ground-breaking science in X-ray astrophysics. Their development has been one of the driving applications of the low temperature detector community since the early 1980s. While their application in space remains in relative infancy, we are on the verge of an era in which microcalorimeter spectrometers are likely to dominate instrumentation for high-energy astrophysics missions. NASA sounding rocket experiments such as the X-ray Quantum Calorimeter (XQC) and Micro-X have now paved the way for orbital observatories. JAXA’s Astro-H gave us a glimpse of this fantastic new capability before its unfortunate demise. The launch of XRISM later this year should finally demonstrate the sort of large suite of observations that X-ray microcalorimeter arrays will make major contributions to. In the mid-2030s, we will see the launch of ESA’s flagship Athena mission, that will further advance the imaging and spectroscopic capabilities for the high-energy X-ray community enormously. Numerous other potential new mission concepts using X-ray microcalorimeters have been studied in detail such as NASA’s Lynx and the Light Element Mapper (LEM), JAXA’s Super-DIOS, and China’s Hot Universe Baryon Surveyor (HUBS). In the first half of this presentation, I will review the development and desired requirements of the X-ray microcalorimeter missions and concepts, and describe the current progress and status missions being implemented and proposed. In the second half of this presentation, I will focus on The Line Emission Mapper (LEM) which is a probe-class mission concept under study by NASA that is designed to provide unprecedented insight into the physics of galaxy formation, including stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. LEM incorporates a light-weight X-ray optic with 10” angular resolution and a large-format microcalorimeter array with a 15” pixel pitch over a 29’ field of view (FOV). The main microcalorimeter array and readout design takes advantage of mature technology that has been developed for Athena X-IFU. The central 7’ region of the array consists of ~ 800 transition-edge sensors (TESs), optimized for a bandpass of 0.3-2 keV and with an energy resolution of 1.2 eV at 1 keV. The rest of the FOV is covered by 4-pixel TES hydras with 2.5 eV energy resolution at 1 keV. Hydras are position-sensitive (‘thermally multiplexed’) detectors that enable extremely large numbers of effective pixels in an array, without a commensurate increase in the number of wires, bias circuit, and readout components. In total the array will have ~ 4k TESs with ~ 14k imaging elements on a 290 micron-pitch. The array will be read out with state-of-the-art time-division multiplexing (TDM), implement with 59 pixels (and 1 dark pixel) in each of the 69 TDM columns. Here we present a detailed overview of the baseline microcalorimeter detector design and present first results from both single pixel TESs and 4-pixel hydras. Our prototype LEM pixels utilize 15um x 50um Mo/Au TESs with a transition temperature of around 58 mK. These pixels incorporate high-fill-factor Au absorbers of thickness 0.54um. We have demonstrated an energy resolution of 0.90+/-0.02 eV and 1.90 +/-0.02 eV at 1.5 keV for single pixel and 4-pixel hydras, respectively, meeting the performance requirements of LEM. We show how the position discrimination in the hydra pixels can be achieved, down to energies of a few 100 eV, using the measured pulse rise-times. Finally, we will show that the properties of the LEM pixels are well optimized for the proposed TDM read out architecture.

Simon Richard Bandler↗

Study of CdZnTeSe Gamma-Ray Detector under Various Bias Voltages

Cadmium zinc telluride selenide (CdZnTeSe) is a new semiconductor material for gamma-ray detection and spectroscopy applications at room temperature. It has very high crystal quality compared to similar materials such as cadmium telluride and cadmium zinc telluride. The consistency of peak position in radiation detection devices is important to practical applications. In this paper, we have characterized a CdZnTeSe planar detector for bias voltages in the range of -20 V to -200 V and amplifier shaping time of 2, 3 and 6 μs. The peak position of the 59.6-keV gamma line of 241 Am becomes more stable as the absolute value of the applied voltage increases. The best energy resolution of 8.5% was obtained for the 59.6-keV gamma peak at -160 V bias voltage and 3-μs shaping time. The energy resolution was relatively stable in the -120 V to -200 V range for a 6-μs shaping time. Future work will be focused on the study of the peak position and energy resolution over time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of the neutron tracking capability of NEXT array in time-of-flight measurements to improve energy resolution

Precise neutron-energy measurements are required to probe the nuclear structure effects of neutron-rich nuclei, where β-delayed neutron emission becomes a dominant decay mode. The Neutron dEtector with Xn Tracking (NEXT) array has been designed and constructed to measure β-delayed neutrons with better energy resolution. The new design localizes the neutron interaction position by optically segmenting the detector along the direction of the neutron flight path, reducing the associated uncertainties in the neutron time-of-flight measurements. This significantly improves the energy resolution without losing the necessary detection efficiency. The proof-of-principle and efficiency measurements showed promising results. Herein, this article details the implementation of the neutron tracking capability of NEXT array in time-of-flight measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Locations of solar radio bursts

Measurements of the positions of the sources of solar radio bursts at decameter wavelengths, 20- to 60-MHz range, provide information about physical conditions in a region of the corona extending from about one-half to several solar radii from the surface of the sun. Position measurements in the 20- to 60-MHz range were made with the Clark Lake sweep-frequency grating interferometer. Although the resolution of the instrument is sufficient to measure source position accurately, the highly variable effect of refraction in the earth's ionosphere severely limits the observations, distorting position determinations to such an extent as to make much of the position data useless unless ionospheric refraction can be taken into account. A method was developed for the removal of the refractive effect from the data to permit determination of true source position. With this technique it is considered possible to measure spatial extent of radio sources that will provide information about emission processes and physical parameters in the corona.

Fitzenreiter, R.↗

Charge Resolution of the Silicon Matrix of the ATIC Experiment

ATIC (Advanced Thin Ionization Calorimeter) is a balloon borne experiment designed to measure the cosmic ray composition for elements from hydrogen to iron and their energy spectra from approx.50 GeV to near 100 TeV. It consists of a Si-matrix detector to determine the charge of a CRT particle, a scintillator hodoscope for tracking, carbon interaction targets and a fully active BGO calorimeter. ATIC had its first flight from McMurdo, Antarctica from 28/12/2000 to 13/01/2001. The ATIC flight collected approximately 25 million events. The silicon matrix of the ATIC spectrometer is designed to resolve individual elements from proton to iron. To provide this resolution careful calibration of each pixel of the silicon matrix is required. Firstly, for each electronic channel of the matrix the pedestal value was subtracted taking into account its drift during the flight. The muon calibration made before the flight was used then to convert electric signals (in ADC channel number) to energy deposits in each pixel. However, the preflight muon calibration was not accurate enough for the purpose, because of lack of statistics in each pixel. To improve charge resolution the correction was done for the position of Helium peak in each pixel during the flight . The other way to set electric signals in electronics channels of the Si-matrix to one scale was correction for electric channel gains accurately measured in laboratory. In these measurements it was found that small different nonlinearities for different channels are present in the region of charge Z > 20. The correction for these non-linearities was not done yet. In linear approximation the method provides practically the same resolution as muon calibration plus He-peak correction. For searching a pixel with the signal of primary particle an indication from the cascade in the calorimeter was used. For this purpose a trajectory was reconstructed using weight centers of energy deposits in BGO layers. The point of intersection of this trajectory with Si-matrix and its RMS was determined. The pixel with maximal signal in 3sigma region was taken as sought. The signal in this pixel was corrected by trajectory zenith angle. The preliminary results on charge resolution of the Si-matrix in the range from protons to iron are presented.

Zatsepin, V. I.↗