Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PPb”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Quantitative insights for diagnosing performance bottlenecks in lithium–sulfur batteries

Lithium–sulfur (Li–S) batteries hold significant promise for electric vehicles and aviation due to their high energy density and cost-effectiveness. However, understanding the root causes of performance degradation remains a formidable challenge, as the interplay of multiple factors obscures key failure mechanisms. A major limitation has been the inability to quantify soluble sulfur species within practical detection limits accurately and to correlate electrochemical processes with associated physical inventory changes. Here, we introduce the high-performance liquid chromatography-ultraviolet spectroscopy and gas chromatography sequential characterization (HUGS) toolkit, capable of precisely quantifying seven distinct sulfur and polysulfide species at concentrations as low as 40 ppb. HUGS has been successfully applied to practical coin and pouch cells without requiring cell modification. Furthermore, our self-developed software, Dr HUGS, enhanced the data analysis speed by over 30 times, enabling multi-source data integration and delivering comprehensive analysis results within minutes. Using HUGS, we identify significant capacity losses from inactive lithium and sulfur during initial cycles and sulfide-rich solid–electrolyte interphase (SEI) formation on the anode during later cycles. Notably, our findings reveal that soluble polysulfides have minimal contributions to capacity loss, challenging long-standing assumptions. Moreover, HUGS demonstrates that constant-pressure setups in Li–S pouch cells improve compositional uniformity compared to constant-gap configurations. For sulfurized polyacrylonitrile (SPAN) cathodes, unique issues such as non-sulfide SEI formation and lithium pulverization are observed, which can be mitigated through localized high-concentration electrolytes to enhance lithium inventory retention. By enabling precise quantification of critical inventory components, HUGS provides transformative insights into failure mechanisms across various electrolytes and cathode chemistries, guiding rational design strategies for next-generation energy storage systems.

25 ENERGY STORAGE↗

Electron cyclotron resonance (ECR) magnetometry with a plasma reservoir

The local magnetic field in a Penning–Malmberg trap is found by measuring the temperatures that result when electron plasmas are illuminated by microwave pulses. Multiple heating resonances are observed as the pulse frequencies are swept. The many resonances are due to electron bounce and plasma rotation sidebands. The heating peak corresponding to the cyclotron frequency resonance is identified to determine the magnetic field. A new method for quickly preparing low density electron plasmas for destructive temperature measurements enables a rapid and automated scan of microwave frequencies. This technique can determine the magnetic field to high precision, obtaining an absolute accuracy better than 1 ppm and a relative precision of 26 ppb. One important application is in situ magnetometry for antihydrogen-based tests of charge-parity-time symmetry and of the weak equivalence principle.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photoacoustic methane gas analyser based on a 3.3-μm optical parametric oscillator

We demonstrate a bench-scale prototype of a photoacoustic (PA) methane gas analyser that takes advantage of an optical parametric oscillator (OPO) based on a fan-out MgO : PPLN structure and resonant differential PA detector. The OPO emits in a repetitively pulsed mode (∼1750 Hz) at an idler wavelength of ∼3.3 μm with an average power of ∼40 – 50 mW. Using the prototype laser PA gas analyser, we experimentally demonstrate the feasibility of measuring the background methane concentration in air (∼2 – 3 ppm of CH{sub 4}). The threshold sensitivity of the PA gas analyser (1σ) is determined to be ∼ 49 ppb of CH{sub 4}. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physics with high-luminosity proton-nucleus collisions at the LHC

The physics case for the operation of high-luminosity proton-nucleus (pA) collisions at the CERN LHC is reviewed. The collection of $\mathcal{O}$(1–10 pb −1 ) of proton-lead (pPb) collisions at the LHC will provide unique physics opportunities in a broad range of topics including proton and nuclear parton distribution functions (PDFs and nPDFs), generalised parton distributions (GPDs), transverse momentum dependent PDFs (TMDs), low-x quantum chromodynamics and parton saturation, hadron spectroscopy, baseline studies for quark-gluon plasma and parton collectivity, double and triple parton scatterings, photon–photon collisions, and physics beyond the Standard Model; which are not otherwise as clearly accessible by exploiting data from any other colliding system at the LHC. This report summarises the accelerator aspects of high-luminosity pA operation at the LHC, as well as each of the physics topics outlined above, including the relevant experimental measurements that motivate much larger pA datasets than collected to date.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Redesigning the Jefferson Lab Hall A beam line for high precision parity experiments

The Continuous Electron Beam Accelerator Facility (CEBAF) was built with a thermionic electron source and the three original experimental hall lines reflected this. A few years after beam delivery began a parity violation experiment was approved and two polarimeters were installed in the Hall A beam line. The beam raster system was placed after the new Compton polarimeter, before one accelerator quadrupole and four quadrupoles in the new Moller polarimeter. It was very difficult to meet experimental requirements on envelope functions and raster shape with this arrangement so a sixth quadrupole was installed downstream of the Moller polarimeter to provide an additional degree of freedome. All of the parity experiments in Hall A have been run with this still-unsatisfactory configuration. The MOLLER experiment is predicated on achieving a 2% error on a 32 ppb asymmetry. Beam line changes are required to meet the systematic error budget. This work documents the existing beam line, an interim change which can be accomplished during a annual maintenance down, and the final configuration for MOLLER and subsequent experiments.

47 OTHER INSTRUMENTATION↗

Multiscale structural analysis of polymorphic phase boundaries in doped antiferroelectric sodium niobate

In the current work, we have performed multiscale structural analysis of a Pb-free sodium niobate-based smart system, i.e., 0.9⁢NaNbO 3 –0.1⁢Ba 0.9 ⁢Ca 0.1 ⁢TiO 3 (NN-10BCT) reported earlier for its high ferroelectric response. We have investigated the temperature-dependent evolution of crystal structure at long, medium, and short ranges using synchrotron x-ray diffraction (SXRD), Raman scattering, and pair distribution function(PDF) techniques in conjunction with dielectric studies. Temperature-dependent synchrotron x-ray diffraction data combined with dielectric analysis suggest two unique polymorphic phase boundaries (PPB) with two coexisting ferroelectric phases stable in the wide temperature ranges. These PPBs are stable in different regions viz. (i) cryogenic temperatures with coexisting R3c and Pmc⁢2 1 phases (ii) vicinity of room temperatures with coexisting Pmc⁢2 1 and Amm2 phases. In contrast to the conclusions drawn from SXRD, PDF reveals structures having lower symmetry (with coexisting Cc+ Pmc2 1 phases at 1.7 ≤r≤ 20 Å) at short ranges for these PPBs. In conclusion, the presence of different long- and short-range symmetries (accommodating tilt-oriented ferroelectric phases) in the unique polymorphic phase boundaries makes them thermally stable and advantageous for technological applications.

36 MATERIALS SCIENCE↗

Dielectron production in proton-proton and proton-lead collisions at $\sqrt{s_{NN}}$=5.02TeV

The first measurements of dielectron production at midrapidity (|η e | < 0.8) in proton–proton and proton–lead collisions at $\sqrt{s_{NN}}$ = 5.02 TeV at the LHC are presented. The dielectron cross section is measured with the ALICE detector as a function of the invariant mass m ee and the pair transverse momentum p T,ee in the ranges mee < 3.5 GeV/c 2 and p T,ee < 8 GeV/c, in both collision systems. In proton–proton collisions, the charm and beauty cross sections are determined at midrapidity from a fit to the data with two different event generators. This complements the existing dielectron measurements performed at $\sqrt{s}$ = 7 and 13 TeV. The slope of the $\sqrt{s}$ dependence of the three measurements is described by FONLL calculations. The dielectron cross section measured in proton–lead collisions is in agreement, within the current precision, with the expected dielectron production without any nuclear matter effects for e + e - pairs from open heavy-flavor hadron decays. For the first time at LHC energies, the dielectron production in proton–lead and proton–proton collisions are directly compared at the same $\sqrt{s_{NN}}$ via the dielectron nuclear modification factor R pPb . The measurements are compared to model calculations including cold nuclear matter effects, or additional sources of dielectrons from thermal radiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First measurement of Λ c + production down to p T = 0 in p p and p -Pb collisions at s N N = 5.02 TeV

The production of prompt $Λ_{c}^{+}$ baryons has been measured at midrapidity in the transverse momentum interval 0 < p T < 1 GeV/c for the first time, in pp and p–Pb collisions at a center-of-mass energy per nucleon-nucleon collision $\sqrt{s_{NN}}$ = 5.02 TeV . The measurement was performed in the decay channel $Λ_{c}^{+}$ → p$K_{S}^{0}$ by applying new decay reconstruction techniques using a Kalman-Filter vertexing algorithm and adopting a machine-learning approach for the candidate selection. The p T -integrated $Λ_{c}^{+}$ production cross sections in both collision systems were determined and used along with the measured yields in Pb–Pb collisions to compute the p T -integrated nuclear modification factors R pPb and R AA of $Λ_{c}^{+}$ baryons, which are compared to model calculations that consider nuclear modification of the parton distribution functions. The $Λ_{c}^{+}$/D 0 baryon-to-meson yield ratio is reported for pp and p–Pb collisions. Comparisons with models that include modified hadronization processes are presented, and the implications of the results on the understanding of charm hadronization in hadronic collisions are discussed. A significant (3.7σ) modification of the mean transverse momentum of $Λ_{c}^{+}$ baryons is seen in p –Pb collisions with respect to pp collisions, while the p T -integrated $Λ_{c}^{+}$/D 0 yield ratio was found to be consistent between the two collision systems within the uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Absolute Magnetometry with He3

We report development of a highly accurate (parts per billion) absolute magnetometer based on 3He NMR. Optical pumping polarizes the spins, long coherence times provide high sensitivity, and the 3He electron shell effectively isolates the nuclear spin providing accuracy limited only by corrections including materials, sample shape, and magnetization. Our magnetometer was used to confirm calibration, to 32 ppb, of the magnetic-field sensors used in recent measurements of the muon magnetic moment anomaly g-2, which differs from the standard model by 2.4 ppm. With independent determination of the magnetic moment of 3He, this work will lead the way to a new absolute magnetometry standard.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a Low-Cost, Sensitivity-Optimized Fluorescence Sensor for Visible Spectrum Analysis

This paper presents an economically viable, sensitivity-optimized fluorescence sensor for detecting low concentrations of fluorophores in the visible spectrum range. The sensor employs a deep ultraviolet (DUV) 275-nm LED and a dichroic mirror to establish a co-axial optical path for excitation and emission. Instead of utilizing a general-purposed spectrometer optimized for high spectral resolution, the sensor strikes a balance between resolution and sensitivity by using an appropriate aperture size and optimized optical design tailored for the spectral characteristics of fluorophores. Here, the manuscript demonstrates measurements of ppb-level rare earth element (REE) samples containing terbium (Tb), europium (Eu), dysprosium (Dy), and samarium (Sm) in aqueous solutions. Through balanced design that optimizes collection of fluorescence emission without losing spectral information, this work shows the feasibility of developing a low-cost, compact, and highly sensitive fluorescence sensors with improved detection sensitivity when compared to bench-top commercial spectrofluorometers at far higher costs.

47 OTHER INSTRUMENTATION↗

Real-Time High-Accuracy Digital Wireless Time, Frequency, and Phase Calibration for Coherent Distributed Antenna Arrays

his work presents a fully-digital high-accuracy real-time calibration procedure for frequency and time alignment of open-loop wirelessly coordinated coherent distributed antenna array (CDA) modems, enabling radio frequency (RF) phase coherence of spatially separated commercial off-the-shelf (COTS) software-defined radios (SDRs) without cables or external references such as the global navigation satellite system (GNSS). Building on previous work using high-accuracy spectrally-sparse time of arrival (ToA) waveforms and a multistep ToA refinement process, a high-accuracy two-way time transfer (TWTT)-based time–frequency coordination approach is demonstrated. Due to the two-way nature of the high-accuracy TWTT approach, the time and frequency estimates are Doppler and multipath tolerant, so long as the channel is reciprocal over the synchronization epoch. This technique is experimentally verified using COTS SDRs in a lab environment in static and dynamic scenarios and with significant multipath scatterers. Time, frequency, and phase stability were evaluated by beamforming over coaxial cables to an oscilloscope which achieved time and phase precisions of ~60– 70 ps , with median coherent gains above 99% using optimized coordination parameters, and a beamforming frequency root-mean-square error (RMSE) of 3.73 ppb in a dynamic scenario. Finally, experiments were conducted to compare the performance of this technique with previous works using an analog continuous-wave two-tone (CWTT) frequency reference technique in both static and dynamic settings.

Clock synchronization↗

Charm fragmentation fractions and $\mathbf {c\overline{c}}$ cross section in p–Pb collisions at $\mathbf {\sqrt{s _{NN}}=5.02 TeV}$

The total charm-quark production cross section per unit of rapidity dσ($\mathbf {c\overline{c}}$)/dy, and the fragmentation fractions of charm quarks to different charm-hadron species f(c → h c ), are measured for the first time in p–Pb collisions at $\sqrt{s_{NN}}$ = 5.02 TeV at midrapidity (–0.96 < y < 0.04 in the centre-of-mass frame) using data collected by ALICE at the CERN LHC. The results are obtained based on all the available measurements of prompt production of ground-state charm-hadron species: D 0 , D + , D$^{+}_{s}$, and J/ψ mesons, and Λ$^{+}_{c}$ and $Ξ$$^{0}_{c}$ baryons. The resulting cross section is dσ($\mathbf {c\overline{c}}$)/dy = 219.6 ± 6.3 (stat.) $^{+10.5}_{–11.8}$ (syst.) $^{+8.3}_{–2.9}$ (extr.) ± 5.4 (BR) ± 4.6 (lumi.) ± 19.5 (rapidity shape) + 15.0 (Ω$^{0}_{c}$) mb, which is consistent with a binary scaling of pQCD calculations from pp collisions. The measured fragmentation fractions are compatible with those measured in pp collisions at $\sqrt{s_{NN}}$ = 5.02 and 13 TeV, showing an increase in the relative production rates of charm baryons with respect to charm mesons in pp and p–Pb collisions compared with e + e – and e – p collisions. The p T -integrated nuclear modification factor of charm quarks, R pPb ($\mathbf {c\overline{c}}$) = 0.91 ± 0.04 (stat.) $^{+0.08}_{–0.09}$ (syst.) $^{+0.05}_{–0.03}$ (extr.) ± 0.03 (lumi.), is found to be consistent with unity and with theoretical predictions including nuclear modifications of the parton distribution functions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of an Electrochemical Hydrogen Contaminant Detector

Hydrogen refueling stations (HRSs) that dispense hydrogen to fuel cell vehicles need to ensure the quality of hydrogen to avoid contamination of the vehicle’s expensive fuel cell stacks. Currently, stations verify their fuel quality only periodically to ensure that they meet the strict fuel quality standards specified by either International Organization for Standards (ISO) or Society for Automotive Engineers (SAE). The development of hydrogen contaminant detectors (HCDs) that can provide low cost continuous monitoring at the HRS can be an invaluable asset in protecting fuel cell vehicles from any fuel contamination in-between infrequent expensive analysis of hydrogen fuel quality. An HCD capable of detecting < 200 ppb of CO in hydrogen is presented in this paper. The HCD is based on an electrochemical hydrogen pumping cell whose ultra-low loaded working electrode is poisoned by the contaminant, thus reducing its hydrogen oxidation reaction rate. The hydrogen pumping cell consists of a Nafion® membrane, a sputtered Pt working electrode, a Pt/Ru counter/pseudo-reference electrode and an internal water wicking system that provides humidification to the membrane and electrodes. When this HCD is operated in a pulsed voltammetry mode, it can provide stable CO response for thousands of hours in a HRS.

47 OTHER INSTRUMENTATION↗

The influence of dietary intake of omega-3 polyunsaturated fatty acids on the association between short-term exposure to ambient nitrogen dioxide and respiratory and cardiovascular outcomes among healthy adults

Background: Short-term exposure to ambient nitrogen dioxide (NO 2 ) is associated with adverse respiratory and cardiovascular outcomes. Supplementation of omega-3 polyunsaturated fatty acids (PUFA) has shown protection against exposure to fine particulate matter. This study aims to investigate whether habitual omega-3 PUFA intake differentially modify the associations between respiratory and cardiovascular responses and short-term exposure to ambient NO 2 . Methods: Sixty-two healthy participants were enrolled into low or high omega-3 groups based on their habitual omega-3 PUFA intake. Each participant was repeatedly assessed for lung function, blood lipids, markers of coagulation and fibrinolysis, vascular function, and heart rate variability (HRV) in up to five sessions, each separated by at least 7 days. This study was carried out in the Research Triangle area of North Carolina, USA between October 2016 and September 2019. Daily ambient NO 2 concentrations were obtained from an area air quality monitoring station on the day of outcome assessment (Lag0), 4 days prior (Lag1-4), as well as 5-day moving average (5dMA). The associations between short-term exposure to NO 2 and the measured indices were evaluated using linear mixed-effects models stratified by omega-3 levels and adjusted by covariates including relative humidity and temperature. Results: The average concentration of ambient NO 2 during the study periods was 5.3±3.8 ppb which was below the National Ambient Air Quality Standards (NAAQS). In the high omega-3 group, an interquartile range (IQR) increase in short-term NO 2 concentrations was significantly associated with increased lung function [e.g. 1.2% (95%CI: 0.2%, 2.2%) in FVC at lag1, 2.6% (95%CI: 0.4%, 4.8%) in FEV1 at 5dMA], decreased blood lipids [e.g. -2.6% (95%CI: -4.4%, -0.9%) in total cholesterol at lag2, -3.1% (95%CI: -6.1%, 0.0%) in HDL at 5dMA, and -3.1% (95%CI: -5.5%, -0.7%) in LDL at lag2], improved vascular function [e.g. 8.9% (95%CI: 0.6%, 17.2%) increase in FMD and 43.1% (95%CI: -79.8%, -6.3%) decrease in endothelin-1 at 5dMA], and changed HRV parameters [e.g. -7.2% (95%CI: -13.6%, -0.8%) in HFn and 13.4% (95%CI: 0.2%, 28.3%) in LF/HF ratio at lag3]. In the low omega-3 group, an IQR increase in ambient NO 2 was associated with elevations in coagulation markers (von Willebrand Factor, D-dimer) and a decrease in HRV (very-low frequency); however, null associations were observed between short-term NO 2 exposure and changes in lung function, blood lipids, and vascular function. Conclusions: The results in this study imply that dietary omega-3 PUFA consumption may offer respiratory and vascular benefits in response to short-term exposure of healthy adults to NO 2 levels below the NAAQS.

54 ENVIRONMENTAL SCIENCES↗

Air quality and health impacts of the 2020 wildfires in California

Abstract Background Wildfires in 2020 ravaged California to set the annual record of area burned to date. Clusters of wildfires in Northern California surrounded the Bay Area covering the skies with smoke and raising the air pollutant concentrations to hazardous levels. This study uses the Fire Inventory from the National Center for Atmospheric Research database and the Community Multiscale Air Quality model to estimate the effects of wildfire emissions on air quality during the period from August 16 to October 28 of 2020. In addition, low-cost sensor data for fine particulate matter (PM 2.5 ) from the PurpleAir network is used to enhance modeled PM 2.5 concentrations. The resulting impacts on ozone and PM 2.5 are used to quantify the health impacts caused by wildfires using the Benefits Mapping and Analysis Program – Community Edition. Results Wildfire activity significantly increased direct PM 2.5 emissions and emissions of PM 2.5 and ozone precursors. Direct PM 2.5 emissions surged up to 38 times compared to an average day. Modeling results indicated that wildfires alone led to a rise in ozone daily maximum 8-h average by up to 10 ppb and exceeded PM 2.5 air quality standards in numerous locations by up to 10 times. While modeled PM 2.5 concentrations were lower than measurements, correcting these with PurpleAir data improved the accuracy. The correction using PurpleAir data increased estimates of wildfire-induced mortality due to PM 2.5 exposure by up to 16%. Conclusions The increased hospital admissions and premature mortality attributed to wildfires were found to be comparable to the health impacts avoided by strategies aimed at meeting ozone and PM2.5 air quality standards. This suggests that widespread wildfire emissions can negate years of efforts dedicated to controlling air pollution. The integration of low-cost sensor data proved invaluable in refining the estimates of health impacts from PM2.5 resulting from wildfires.

54 ENVIRONMENTAL SCIENCES↗

Fermilab Muon $g - 2$ experiment: Current status

The Muon $g$ - 2 experiment at Fermilab (E989) is currently measuring the muon magnetic anomaly with a goal precision of 140 part per billion, which will be a fourfold precision improvement over the current best measurement by the previous Muon $g$ -2 experiment at the Brookhaven Laboratory (BNL). The BNL-measured value of the muon magnetic anomaly and the corresponding Standard Model (SM) best estimate differ by more than three standard deviation which inspired the current measurement as well as a theoretical drive for a significantly more precise calculation of the muon magnetic anomaly to rule out (or establish) statistical fluctuation as the origin of such a huge discrepancy. Stable central values along with 4-fold precision improvements in both theoretical (SM) and experimental fronts, would imply a ~ 7σ discrepancy and that will be a clear hint of the physics beyond the Standard Model. Such an unprecedented precision demands state-of-the-art technological improvements in all involved components to keep the systematic uncertainty below 70 ppb. This paper reports the current status of the E989 experiment after two years of data acquisition.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Association between long-term exposure to ambient air pollution and COVID-19 severity: a prospective cohort study

The tremendous global health burden related to COVID-19 means that identifying determinants of COVID-19 severity is important for prevention and intervention. We aimed to explore long-term exposure to ambient air pollution as a potential contributor to COVID-19 severity, given its known impact on the respiratory system. Methods: We used a cohort of all people with confirmed SARS-CoV-2 infection, aged 20 years and older and not residing in a long-term care facility in Ontario, Canada, during 2020. We evaluated the association between long-term exposure to fine particulate matter (PM 2.5 ), nitrogen dioxide (NO 2 ) and ground-level ozone (O 3 ), and risk of COVID-19-related hospital admission, intensive care unit (ICU) admission and death. We ascertained individuals’ longterm exposures to each air pollutant based on their residence from 2015 to 2019. We used logistic regression and adjusted for confounders and selection bias using various individual and contextual covariates obtained through data linkage. Results: Among the 151105 people with confirmed SARS-CoV-2 infection in Ontario in 2020, we observed 8630 hospital admissions, 1912 ICU admissions and 2137 deaths related to COVID-19. For each interquartile range increase in exposure to PM 2.5 (1.70 µg/m 3 ), we estimated odds ratios of 1.06 (95% confidence interval [CI] 1.01–1.12), 1.09 (95% CI 0.98–1.21) and 1.00 (95% CI 0.90–1.11) for hospital admission, ICU admission and death, respectively. Estimates were smaller for NO 2 . We also estimated odds ratios of 1.15 (95% CI 1.06–1.23), 1.30 (95% CI 1.12–1.50) and 1.18 (95% CI 1.02–1.36) per interquartile range increase of 5.14 ppb in O 3 for hospital admission, ICU admission and death, respectively.

60 APPLIED LIFE SCIENCES↗

A tailored fast thioacidolysis method incorporating multi-reaction monitoring mode of GC-MS for higher sensitivity on lignin monomer quantification

Abstract Thioacidolysis is widely used for lignin structural characterization by cleaving β-aryl ethers to release syringyl (S), guaiacyl (G), and p -hydroxyphenyl (H) monomers followed by GC analysis. However, the traditional thioacidolysis method requires tedious extraction steps with chlorinated solvent underlying harmful to health, limiting its efficiency and application. Herein, an improved thioacidolysis method with high sensitivity for the quantitation of lignin-derived monomers was developed. The improved protocol used a quick, streamlined procedure to recover the monomeric products using ethyl acetate as extracting solvent and MS detector in multi-reaction monitoring mode to enhance its ability to detect extremely low concentration (0.1 ppb with signal-to-noise higher than 2) of monomeric products. Additionally, a fast GC program was established to speed up the GC quantitation. Several representative lignocellulose samples, including gymnosperm, angiosperm, and poaceae, were used to test this tailored method. The results demonstrated that the ratios of lignin monomer compositions determined by this method were consistent with that of traditional procedure despite the slightly higher monomer yields measured. More importantly, this method uses non-chlorinated solvent for microscale extraction and requires no evaporation step for workup, which is a green and efficient way for the quantification of lignin monomer compositions.

Forestry↗