Real-Time Distributed Control of Smart Inverters for Network-level Optimization

The limitations of centralized optimization methods in managing electric power distribution systems operations have led to the distributed paradigm of computing and decision-making. Unfortunately, the existing distributed optimization algorithms are limited in their applicability to managing fast varying phenomena such as those resulting from highly variable Distributed Energy Resource (DER) generation patterns. They require a large number of communication rounds (in the order of 10 2 to 10 3 ) among the computing agents to solve one instance of the optimization problem. Related real-time distributed control methods are equally limited in their applications to power distribution systems with fast-changing DER generation; they require hundreds of rounds of communication and thus are slow in tracking the network-level optimal solutions. In this paper, we propose a novel distributed voltage controller that provides a fast-tracking of rapidly varying DER generation profiles while simultaneously converging to network-level optimal solutions within a few communication rounds. The proposed control algorithm leverages the radial topology of the system, which reduces the required communication rounds to reach the network-level optimum solution by order of magnitude. The novelty lies in carefully reducing the electrical network model from the perspective of each distributed controller and enabling appropriate data sharing among upstream and downstream nodes to achieve fast convergence. The simulation results demonstrate the effectiveness of the proposed approach in minimizing the feeder losses while maintaining the node voltage within the pre-specified limits.

voltage control, optimization, reactive power, inv↗

Phase identification using statistical analysis

A device includes at least one processor configured to determine, based on (i) a first plurality of time-varying electrical measurements corresponding to a feeder head of a power distribution network having a plurality of phases and (ii) a second plurality of time-varying electrical measurements corresponding to a node in the power distribution network, and using statistical analysis, a predicted phase, from the plurality of phases, that corresponds to the node. The processor may be configured to use ranked correlation coefficients (such as the Kendall rank correlation coefficient) to determine the predicted phase and may use principle component analysis. The processor is also configured to cause at least one device of the power distribution network to modify operation based at least on part on the predicted phase.

Veda, Santosh Sambamoorthy↗

Software Verification of VARPOW

The VARPOW program is a post-processing utility program for DIF3D, specifically DIF3DVARIANT, and it was developed to provide interface files for the thermal analysis program DASSH. The basic methodology of VARPOW is to take the neutron and gamma flux (moments) calculated by DIF3D (or GAMSOR) and combine them with the heating (coefficient) cross sections to calculate the spatial power distributions using the DIF3DVARIANT spatial basis. VARPOW can use the output from GAMSOR (both steady state neutron and gamma flux calculations) or standard DIF3D/REBUS calculations (neutron flux only). The correct approach for defining the power distribution is to use GAMSOR as its purpose was to properly compute the gamma heating throughout the modeled domain. The power densities calculated by VARPOW are broken into fuel, cladding and coolant terms for which isotope-wise categorization is needed. VARPOW has built in options the user can select for the isotope categorization or VARPOW can import a file that details the isotope categorization. VARPOW can export the solution in the polynomial basis of DIF3D-VARIANT or the monomial basis of DIF3D-VARIANT. The purpose of this work is to verify the power distribution results calculated by VARPOW from both the GAMSOR and DIF3D input options and verify that the input and output options are consistent with the manual. Hand calculation and independent numerical calculation are used for this verification work.

97 MATHEMATICS AND COMPUTING↗

Software Verification of VARPOW

The VARPOW program is a post-processing utility program for DIF3D, specifically DIF3DVARIANT, and it was developed to provide interface files for the thermal analysis program DASSH. The basic methodology of VARPOW is to take the neutron and gamma flux (moments) calculated by DIF3D (or GAMSOR) and combine them with the heating (coefficient) cross sections to calculate the spatial power distributions using the DIF3DVARIANT spatial basis. VARPOW can use the output from GAMSOR (both steady state neutron and gamma flux calculations) or standard DIF3D/REBUS calculations (neutron flux only). The correct approach for defining the power distribution is to use GAMSOR as its purpose was to properly compute the gamma heating throughout the modeled domain. The power desnities calculated by VARPOW are broken into fuel, cladding and coolant terms for which isotope-wise categorization is needed. VARPOW has built in options the user can select for the isotope categorization or VARPOW can import a file that details the isotope categorization. VARPOW can export the solution in the polynomial basis of DIF3D-VARIANT or the monomial basis of DIF3D-VARIANT. The purpose of this work is to verify the power distribution results calculated by VARPOW from both the GAMSOR and DIF3D input options and verify that the input and output options are consistent with the manual. Hand calculation and independent numerical calculation are used for this verification work.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Economic optimization of the energy transport component of a large distributed solar power plant

A solar thermal power plant with a field of collectors, each locally heating some transport fluid, requires a pipe network system for eventual delivery of energy power generation equipment. For a given collector distribution and pipe network geometry, a technique is herein developed which manipulates basic cost information and physical data in order to design an energy transport system consistent with minimized cost constrained by a calculated technical performance. For a given transport fluid and collector conditions, the method determines the network pipe diameter and pipe thickness distribution and also insulation thickness distribution associated with minimum system cost; these relative distributions are unique. Transport losses, including pump work and heat leak, are calculated operating expenses and impact the total system cost. The minimum cost system is readily selected. The technique is demonstrated on six candidate transport fluids to emphasize which parameters dominate the system cost and to provide basic decision data. Three different power plant output sizes are evaluated in each case to determine severity of diseconomy of scale.

Turner, R. H.↗

Artificial neural network application for space station power system fault diagnosis

This study presents a methodology for fault diagnosis using a Two-Stage Artificial Neural Network Clustering Algorithm. Previously, SPICE models of a 5-bus DC power distribution system with assumed constant output power during contingencies from the DDCU were used to evaluate the ANN's fault diagnosis capabilities. This on-going study uses EMTP models of the components (distribution lines, SPDU, TPDU, loads) and power sources (DDCU) of Space Station Alpha's electrical Power Distribution System as a basis for the ANN fault diagnostic tool. The results from the two studies are contrasted. In the event of a major fault, ground controllers need the ability to identify the type of fault, isolate the fault to the orbital replaceable unit level and provide the necessary information for the power management expert system to optimally determine a degraded-mode load schedule. To accomplish these goals, the electrical power distribution system's architecture can be subdivided into three major classes: DC-DC converter to loads, DC Switching Unit (DCSU) to Main bus Switching Unit (MBSU), and Power Sources to DCSU. Each class which has its own electrical characteristics and operations, requires a unique fault analysis philosophy. This study identifies these philosophies as Riddles 1, 2 and 3 respectively. The results of the on-going study addresses Riddle-1. It is concluded in this study that the combination of the EMTP models of the DDCU, distribution cables and electrical loads yields a more accurate model of the behavior and in addition yielded more accurate fault diagnosis using ANN versus the results obtained with the SPICE models.

Momoh, James A.↗

The synthesis and analysis of color images

A method is described for performing the synthesis and analysis of digital color images. The method is based on two principles. First, image data are represented with respect to the separate physical factors, surface reflectance and the spectral power distribution of the ambient light, that give rise to the perceived color of an object. Second, the encoding is made efficient by using a basis expansion for the surface spectral reflectance and spectral power distribution of the ambient light that takes advantage of the high degree of correlation across the visible wavelengths normally found in such functions. Within this framework, the same basic methods can be used to synthesize image data for color display monitors and printed materials, and to analyze image data into estimates of the spectral power distribution and surface spectral reflectances. The method can be applied to a variety of tasks. Examples of applications include the color balancing of color images, and the identification of material surface spectral reflectance when the lighting cannot be completely controlled.

Wandell, B. A.↗

The synthesis and analysis of color images

A method is described for performing the synthesis and analysis of digital color images. The method is based on two principles. First, image data are represented with respect to the separate physical factors, surface reflectance and the spectral power distribution of the ambient light, that give rise to the perceived color of an object. Second, the encoding is made efficiently by using a basis expansion for the surface spectral reflectance and spectral power distribution of the ambient light that takes advantage of the high degree of correlation across the visible wavelengths normally found in such functions. Within this framework, the same basic methods can be used to synthesize image data for color display monitors and printed materials, and to analyze image data into estimates of the spectral power distribution and surface spectral reflectances. The method can be applied to a variety of tasks. Examples of applications include the color balancing of color images, and the identification of material surface spectral reflectance when the lighting cannot be completely controlled.

Wandell, Brian A.↗

Resilient, Rural, and Revolutionary: Salisbury Square's Direct-Current Affordable Microgrid Community: Preprint

The technology to interconnect buildings with a dedicated direct-current (DC) power distribution network is in place today; what is missing is a turnkey approach to designing a DC microgrid - and the business models allowing such systems to be deployed, owned, and operated at scale. To close this gap, the Salisbury Square Development Team, comprising clean-energy experts, has engineered a resilient community DC microgrid for an affordable housing community in Randolph, Vermont. Ten single-family, occupant-owned residences and 12 multifamily rental units will share locally generated and stored solar energy via a DC power distribution bus capable of operating during extended grid outages. With a DC power distribution network in place, each home will be equipped with high-efficiency DC lighting and appliances, operating alongside alternating current (AC) appliances, even during an islanded mode of operation. To obtain a comprehensive understanding of what is possible and achievable, the Team collaborated with the local utility, regulatory agencies, a national laboratory, energy-as-service providers, and vendors. The collaborators evaluated microgrid typologies, business models, and energy modeling, and analyzed electrification and resilience. Further, the Team applied the URBANoptTM (Urban Renewable Building and Neighborhood optimization, NREL 2022) software development kit (SDK) to Salisbury Square's single-family and multifamily buildings to validate workflows and identify needs for advanced capability. This paper addresses the barriers to entry, scalability, and impact on residents and system ownership. It also examines the analysis that informed the design and engineering of the DC microgrid and the opportunities to streamline the process.

DER↗

Thermal Management and Power Packaging for Spacecraft of the Next Millennium

Power Distribution; Cabling, fault protection and switches to turn power on/off to spacecraft loads; Isolate loads from bus noise and regulate power to load against disturbances from the load and the bus; Protect the power distribution system from load failures.

X2000 Thermal management Power Packaging Next Mill↗

Impact of Radial Reflector Fidelity on Neutronics and Vessel Fluence Simulations

The Consortium for Advanced Simulation of Light Water Reactors is developing the Virtual Environment for Reactor Applications (VERA), and the MPACT code, which is the primary deterministic neutron transport solver in VERA, provides sub-pin level flux and power distributions as part of full-scale cycle depletion and analysis. In such calculations, an important aspect is the radial reflector treatment. To improve the fidelity of the radial reflector treatment, MPACT was extended to approximate the modeling of the reactor’s structural components such as the core shroud, barrel, neutron pads, and vessel. This work explores several modeling configurations with varying levels of fidelity and computational burden and assesses the importance of modeling fidelity on the eigenvalue and pin power distribution. Two two-dimensional (2-D) problems were analyzed to assess the impact on eigenvalue and pin power distributions with low-fidelity, coarse square cell reflector representations: (1) a Watts Bar Nuclear Plant Unit 1 (WBN1) quarter-core slice with depletion and (2) an AP1000 quarter-core slice. In this work, the analyses showed that the effect on eigenvalue is fairly small, but the effect on pin power is more pronounced, especially locally in the assemblies closest to the periphery, where the maximum pin power difference is nearly 3.5% in the AP1000 case. Two additional 2-D problems were used to assess the comparison between the low-fidelity coarse square cell treatment and a high-fidelity geometric representation that uses subpin material specification: (1) the same WBN1 quarter-core slice and (2) a representative model of the NuScale small modular reactor (SMR), which features a solid reflector design with moderator holes. These results demonstrate that even a coarse, low-fidelity representation adequately captures the necessary simulation characteristics. Last, these capabilities were applied to the 2-D WBN1 quarter-core depletion to assess the impact on vessel fluence using VeraShift. From adjoint calculations, pins along the periphery were observed to be of highest importance for fluence calculation, so the impact of the reflector representation in MPACT could theoretically substantially affect the predicted result. However, it was observed that the change in pin powers along the periphery minimally impacts the maximum vessel fluence with a difference within the statistical uncertainty but provides terrific insight on the sensitivity of the peripheral pins.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal and electric multidomain dynamic model for integration of power grid distribution with behind-the-meter devices

As renewable energy sources like solar and wind power become more integrated into the grid, coordinated control of behind-the-meter devices is crucial for enhancing grid flexibility and reliability and for meeting cost targets, with standardized models being developed to support this transition. The increasing flexibility and uncertainty of integrated renewable energy grids, along with interactions between various subsystems, make traditional steady-state modeling insufficient to capture transient and dynamic behaviors. Current models (e.g., composite load and battery equivalent models) focus on thermodynamic or electrical characteristics but overlook critical electromechanical interactions. This limits the ability to share performance information for grid services and hampers fast dynamic simulations. In addition, motor stalling is usually triggered by a fault event and attributed to the characteristics of the mechanical torque of the motor, resulting in absorption of a large amount of reactive power during the stalling period. Further, this significant withdrawal of reactive power will deteriorate the dynamic voltage stability of power grids and cause delayed voltage recovery. Therefore, an in-depth modeling of the thermodynamics or mechanical torque is essential to study the impacts of the realistic torque characteristics of those behind-the-meter devices on power system voltage stability. This study developed a dynamic multidomain model for building HVAC systems, such as air-source heat pumps, to simulate their thermal and electrical responses to grid transients. The model can accurately predict power metrics with a mean absolute percentage error of 10%, by validating against with power system computer-aided design performance data. Case studies demonstrate the model capability of capturing the transient response to sudden voltage changes, rapid load fluctuations, and system shutdowns respectively. During a sudden voltage drop (30% for 0.1s), a fully loaded heat pump’s motor speed dropped, continued declining, and shut down after 3.6s, with severe power oscillations and a torque spike. A partially loaded unit experienced temporary oscillations but stabilized. Under higher building loads, compressor speed increased from 64% to 100%, with power and torque rising before stabilizing. In safety-triggered shutdowns, power decreased after minor fluctuations, and torque briefly spiked before dropping to zero.

24 POWER TRANSMISSION AND DISTRIBUTION↗

HMI Data Driven Magnetohydrodynamic Model Predicted Active Region Photospheric Heating Rates: Their Scale Invariant, Flare Like Power Law Distributions, and Their Possible Association With Flares

A data driven, near photospheric, 3 D, non-force free magnetohydrodynamic model pre- dicts time series of the complete current density, and the resistive heating rate Q at the photosphere in neutral line regions (NLRs) of 14 active regions (ARs). The model is driven by time series of the magnetic field B observed by the Helioseismic & Magnetic Imager on the Solar Dynamics Observatory (SDO) satellite. Spurious Doppler periods due to SDO orbital motion are filtered out of the time series for B in every AR pixel. Errors in B due to these periods can be significant. The number of occurrences N(q) of values of Q > or = q for each AR time series is found to be a scale invariant power law distribution, N(Q) / Q−s, above an AR dependent threshold value of Q, where 0.3952 < or = s < or = 0.5298 with mean and standard deviation of 0.4678 and 0.0454, indicating little variation between ARs. Observations show that the number of occurrences N(E) of coronal flares with a total energy released > or = E obeys the same type of distribution, N(E) / E−S, above an AR dependent threshold value of E, with 0.38 < or approx. S < or approx. 0.60, also with little variation among ARs. Within error margins the ranges of s and S are nearly identical. This strong similarity between N(Q) and N(E) suggests a fundamental connection between the process that drives coronal flares and the process that drives photospheric NLR heating rates in ARs. In addition, results suggest it is plausible that spikes in Q, several orders of magnitude above background values, are correlated with times of the subsequent occurrence of M or X flares.

Goodman, Michael L.↗

HMI Data Driven Magnetohydrodynamic Model Predicted Active Region Photospheric Heating Rates: Their Scale Invariant, Flare Like Power Law Distributions, and Their Possible Association With Flares

A data driven, near photospheric, 3 D, non-force free magnetohydrodynamic model predicts time series of the complete current density, and the resistive heating rate Q at the photosphere in neutral line regions (NLRs) of 14 active regions (ARs). The model is driven by time series of the magnetic field B observed by the Helioseismic and Magnetic Imager on the Solar Dynamics Observatory (SDO) satellite. Spurious Doppler periods due to SDO orbital motion are filtered out of the time series for B in every AR pixel. Errors in B due to these periods can be significant. The number of occurrences N(q) of values of Q > or = q for each AR time series is found to be a scale invariant power law distribution, N(Q) / Q−s, above an AR dependent threshold value of Q, where 0.3952 < or = s < or = 0.5298 with mean and standard deviation of 0.4678 and 0.0454, indicating little variation between ARs. Observations show that the number of occurrences N(E) of coronal flares with a total energy released > or = E obeys the same type of distribution, N(E) / E−S, above an AR dependent threshold value of E, with 0.38 < or approx. S < or approx. 0.60, also with little variation among ARs. Within error margins the ranges of s and S are nearly identical. This strong similarity between N(Q) and N(E) suggests a fundamental connection between the process that drives coronal flares and the process that drives photospheric NLR heating rates in ARs. In addition, results suggest it is plausible that spikes in Q, several orders of magnitude above background values, are correlated with times of the subsequent occurrence of M or X flares.

Goodman, Michael L.↗

Enabling Fairness in Distributed PV Curtailment for Voltage Regulation: A Comparative Analysis

The growing adoption of photovoltaic systems in power distribution networks has yielded numerous advantages, but it has also introduced challenges, particularly in managing overvoltage issues. Uncoordinated photovoltaic integration can lead to voltage rise beyond acceptable levels. Curtailing active power is an effective method for addressing overvoltage issues in power distribution systems. Nevertheless, it is essential to distribute the curtailment fairly among the resources to maintain fairness and achieve a well-balanced utilization of renewable energy. This paper presents a comparative study of different fairness schemes for active power curtailment in photovoltaic integration systems. Three different curtailment methods are selected for demonstration: i) proportional, ii) egalitarian, and iii) financial. The study involves evaluating the curtailment schemes based on their ability to distribute the curtailed power among the photovoltaic systems in a justifiable manner, focusing on their formulation and distributed solution. A detailed performance comparison is carried out to highlight the cost of catering for fairness schemes in photovoltaic curtailment using relevant metrics, where simulations are carried out using a modified IEEE 123-bus test case.

Mukherjee, Monish↗

Mathematical model for the dc-ac inverter for the Space Shuttle

The reader is informed of what was done for the mathematical modeling of the dc-ac inverter for the Space Shuttle. The mathematical modeling of the dc-ac inverter is an essential element in the modeling of the electrical power distribution system of the Space Shuttle. The electrical power distribution system which is present on the Space Shuttle is made up to 3 strings each having a fuel cell which provides dc to those systems which require dc, and the inverters which convert the dc to ac for those elements which require ac. The inverters are units which are 2 wire structures for the main dc inputs and 2 wire structures for the ac output. When 3 are connected together a 4 wire wye connection results on the ac side. The method of modeling is performed by using a Least Squares curve fitting method. A computer program is presented for implementation of the model along with graphs and tables to demonstrate the accuracy of the model.

Berry, Frederick C.↗

Assessment of the Impact of Realistic Sensor Physics and the Integration of Ex-Core Sensors on Reactor Power Synthesis

In the work documented in this report, a weighting function–based core power synthesis method was applied to multiple Monte Carlo N-Particle (MCNP) reactor models, which are informed based on simulated self-powered neutron detector (SPND) responses. The weighting function method used has been coined the point-based iterative (PBI) method. The goal of this application is to assess the impact of considering realistic sensor physics in the generation of the simulated SPND outputs as well as to consider how the synthesis is impacted based on the inclusion of ex-core detectors in the model. The NuScale small modular reactor (SMR) and Westinghouse AP1000 pressurized water reactor (PWR) are the models that served as the testbeds for the assessment of realistic sensor physics; this was achieved by using Geant4 SPND models in comparison with analytical models, such that the effect of electron transport in realistic SPND geometries in the Geant4 model can be understood in terms of synthesis error and convergence time. The comparison was considered for fuel burnup–induced perturbations, for a range of sensor string densities and synthesized power distribution axial fidelities. The Texas A&M Testing, Research, Isotopes, General Atomics Reactor (TAMU TRIGA) reactor MCNP model was used to assess the impact of ex-core sensors; this was done by performing synthesis with and without the ex-core detectors and by quantifying the synthesis error and number of iterations associated with Gaussian-type perturbations in many locations in the core. The TAMU TRIGA model was particularly pertinent for this study because of the interest in future experimental tests with SPNDs in this reactor, as well as the ease of modifying the MCNP model to include ex-core detectors with heterogeneously described response functions. Results from the comparison between the Geant4 and analytical SPND models indicate that similar average and maximum synthesis errors were obtained for burnup-induced perturbations in both the NuScale SMR and the AP1000. This was true for a range of sensor string densities and axial fidelities. However, there were marked differences between both the Geant4 and analytically informed models in terms of the iterations required to converge on the synthesized power distribution. Namely, the Geant4-informed models tended to lead to fewer iterations, except for a few sensor–core configurations that had particularly numerous iterations. Results from the ex-core sensor assessment with the TAMU TRIGA model indicate that the inclusion of ex-core sensors drastically reduces the synthesis error of Gaussian-type perturbations close to the edge of the core, and it slightly reduces synthesis errors for perturbations closer to the center of the core. This was achieved with a minimal increase in computational cost—that is, the number of iterations required for convergence. The errors were identified to be in the same location as the perturbation in the core, indicating that the methodology remains robust for unperturbed regions of the core. A secondary result from this study with the TAMU TRIGA was yielded by analysis of the neutron flux levels in the in-core and ex-core sensor locations of the core; these flux levels indicate that SPNDs could be used as both in-core and ex-core sensors, so long as the emitter material is sensitive to thermal neutrons. The results from these studies provide a quantitative understanding of the importance of considering realistic sensor physics and including ex-core sensors to perform accurate and timely power distribution synthesis of a reactor core.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Resilience Analytics for Interdependent Power and Water Distribution Systems

The occurrence of large-scale outages in power distribution systems (PDSs) caused, for instance, by extreme weather events has raised concerns on the cascading impact of the power outages on the resilience of other critical infrastructures, including water distribution systems (WDSs), whose healthy operation highly relies on the availability of power from PDSs. Here, this paper proposes an analytics model for quantifying the interdependence between the resilience of power and water distribution systems. The proposed model first performs spatio-temporal outage analysis on the PDS and WDS to determine the PDS power serving capability and the resulting cascading impact on the WDS water serving capability during the occurrence of disruptions. The resilience interdependence is then determined by a proposed set of six metrics calculated using the power and water serving capability profiles, which trace and quantify the cascading impacts of power outages in the operation of WDSs during the degradation and recovery stages. The proposed analytics model is implemented on the IEEE 33-bus power distribution system supplying power for pumping stations of a 15-node test WDS, considering multiple cases of water storage capacity, single and multiple outage scenarios, and availability of distributed generation. The numerical results demonstrate that the proposed metrics track the temporal and spatial interdependence between the resilience of power and water distribution systems, providing a mechanism to identify weak spots, and assess options to enhance the resilience of the critical water infrastructure.