Digital Single-Phase Power-Factor Controller

Digital circuit has faster response to load changes. Digital power-factor controller senses changing motor-load torques by sampling open-circuit voltage across gate-controlled silicon switch. Circuit responds more rapidly to hanging loads than analog power-factor controllers because no low-pass filter is in feedback loop.

Dabney, R. W.↗

Literature Survey on Operational Voltage Control and Reactive Power Management on Transmission and Sub-Transmission Networks

Voltage and reactive power system control is generally performed following usual patterns of loads, based on off-line studies for daily and seasonal operations. This practice is currently challenged by the inclusion of distributed renewable generation, such as solar. There has been focus on resolving this problem at the distribution level; however, the transmission and sub-transmission levels have received less attention. This paper provides a literature review of proposed methods and solution approaches to coordinate and optimize voltage control and reactive power management, with an emphasis on applications at transmission and sub-transmission level. The conclusion drawn from the survey is that additional research is needed in the areas of optimizing switch shunt actions and coordinating all available resources to deal with uncertain patterns from increasing distributed renewable generation in the operational time frame. These topics are not deeply explored in the literature.

capacitors↗

COMMERCIAL UTILITY PERSPECTIVES ON NUCLEAR POWER PLANT CONTROL ROOM MODERNIZATION

Commercial nuclear power plants (NPPs) in the United States need to modernize their main control rooms (MCR). Many NPPs have done partial upgrades with some success and with some challenges. The Department of Energy’s (DOE) Light Water Reactor Sustainability (LWRS) Program, and in particular the Advanced Instrumentation and Controls (I&C) and Information Systems Technologies Research and Development (R&D) Pathway within LWRS, is designed to assist commercial nuclear power industry with their MCR modernization efforts. As part of this framework, a survey was issued to utility representatives of the LWRS Program Advanced Instrumentation, Information, and Control Systems/Technologies (II&C) Utility Working Group to obtain their views on a range of issues related to MCR modernization, including: drivers, barriers, and technology options, and the effects these aspects will have on concepts of operations, modernization strategies, and staffing. This paper summarizes the key survey results and discusses their implications.

99 GENERAL AND MISCELLANEOUS↗

Microgrid Power Flow Control with Integrated Battery Management Functions

This paper presents a microgrid power flow control for islanded microgrids consisting of photovoltaic (PV) system, battery energy storage system (BESS) and diesel generator. The proposed control ensures automatic coordination among the microgrid units. To achieve the coordination, the local control of PV system and BESS are configured to regulate power flow without relying on communications. The generator is controlled as the back-up source and its connection depends on battery state of charge (SOC). A state machine with hysteresis settings is used to trigger smooth transition among operation modes. Not only does the proposed controller consider battery SOC and power limits, but also integrates three-stage charging control as battery charging mechanism, which is not considered in the existing literature. The proposed control is validated for an islanded hybrid microgrid using an OPAL-RT real-time simulator.

Long, Qian↗

Performance of a flight qualified, thermoelectrically temperature controlled QCM sensor with power supply, thermal controller and signal processor

A thermoelectrically temperature controlled quartz crystal microbalance (QCM) system was developed for the measurement of ion thrustor generated mercury contamination on spacecraft. Meaningful flux rate measurements dictated an accurately held sensing crystal temperature despite spacecraft surface temperature variations from -35 C to +60 C over the flight temperature range. An electronic control unit was developed with magentic amplifier transformer secondary power supply, thermal control electronics, crystal temperature analog conditioning and a multiplexed 16 bit frequency encoder.

Wallace, D. A.↗

Motor power factor controller with a reduced voltage starter

A power factor type motor controller is disclosed in which the conventional power factor constant voltage command signal is replaced during a starting interval with a graduated control voltage. This continuation-impart of a pending patent application (Serial No. 199, 765: Three Phase Factor Controller) provides a means for modifying the operation of the system for a motor start-up interval of 5 to 30 second. Using a ramp generators, an initial ramp-like signal replaces a constant power factor signal supplied by a potentiometer. The ramp-like signal is applied to a 15 terminal where it is summed with an operating power factor signal from phase detectors in order to obtain a control signal for ultimately controlling SCR devices. The SCR devices are turned on at an advancing rate with time responsive to the combination signal described rather than simply a function of a ramp-like signal alone.

Nola, F. J.↗

Magnetic Amplifier-Based Power-Flow Controller

The concept of the magnetic amplifier, a common electromagnetic device in electronic applications in the past, has seldom been used in power systems. In this paper, we introduce the magnetic amplifier-based power-flow controller (MAPFC), an innovative low-cost device that adopts the idea of the magnetic amplifier for power-flow control applications. The uniqueness of MAPFC is in the use of the magnetization of the ferromagnetic core, shared by an ac and a dc winding, as the medium to control the ac winding reactance inserted in series with the transmission line to be controlled. Large power flow in the line can be regulated by the small dc input to the dc winding. Moreover, a project on the R&D of an MAPFC has been funded by the U.S. Department of Energy (DOE) and conducted by the Oak Ridge National Laboratory (ORNL), the University of Tennessee-Knoxville, and Waukesha Electric Systems, Inc. since early 2012. Findings from the project are presented along with some results obtained in a laboratory environment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-efficiency grid-connected photovoltaic module integrated converter system with high-speed communication interfaces for small-scale distribution power generation

This paper presents a high-efficiency grid-connected photovoltaic (PV) module integrated converter (MIC) system with reduced PV current variation. The proposed PV MIC system consists of a high-efficiency step-up DC-DC converter and a single-phase full-bridge DC-AC inverter. An active-clamping flyback converter with a voltage-doubler rectifier is proposed for the step-up DC-DC converter. The proposed step-up DC-DC converter reduces the switching losses by eliminating the reverse-recovery current of the output rectifying diodes. To reduce the PV current variation introduced by the grid-connected inverter, a PV current variation reduction method is also suggested. The suggested PV current variation reduction method reduces the PV current variation without any additional components. Moreover, for centralized power control of distributed PV MIC systems, a PV power control scheme with both a central control level and a local control level is presented. The central PV power control level controls the whole power production by sending out reference power signals to each individual PV MIC system. The proposed step-up DC-DC converter achieves a high-efficiency of 97.5% at 260 W output power to generate the DC-link voltage of 350 V from the PV voltage of 36.1 V. The PV MIC system including the DC-DC converter and the DC-AC inverter achieves a high-efficiency of 95% with the PV current ripple less than 3% variation of the rated PV current. (author)

14 SOLAR ENERGY↗

Real-time simulator and controller of power system using distributed data streaming server

Systems and methods for simulating and controlling a power system in real time, using a controller, are provided. The controller includes a simulation layer to simulate an operation of the power system, a disturbance generation layer to provide data to the simulation layer to disturb the simulated operation of the power system, an application layer to display the simulated operation of the power system and generate a control signal to control, based on the simulated operation of the power system, at least one element of the power system, and a distributed data streaming server (D2S2) to allow interoperability among the simulation layer, the disturbance layer, and the application layer.

Li, Fangxing↗

Improved Controllers For Heaters In Toxic-Gas Combustors

Commercial electronic proportional controllers installed in place of mechanical power controllers for electric heaters in toxic-gas combustors at NASA's Jet Propulsion Laboratory. Designed to maintain temperature of heater at preset value by turning power fully on or fully off when temperature falls below or rises above that value, respectively. Solid-state power controllers overcome deficiencies of mechanical power controllers.

Wishard, James↗

Power Factor Controller Avoids False Turnoff

Single-phase power-factor controller includes special inhibiting circuit to avoid false turnoff. If thyristor trigger signal occurs during flow of current from preceding half cycle, inhibiting signal delays application of trigger pulse until beginning of next current half cycle.

Nola, F. J.↗

Phase Detector for Power-Factor Controller

Positive feedback assures reliable switching. Three Phase Power Factor Controller includes three phase detectors, each produces rectangular waves of duration approximately equal to lag time between line voltage and motor current.

Nola, F. J.↗

Phase detector for three-phase power factor controller

A phase detector for the three phase power factor controller (PFC) is described. The phase detector for each phase includes an operational amplifier which senses the current phase angle for that phase by sensing the voltage across the phase thyristor. Common mode rejection is achieved by providing positive feedback between the input and output of the voltage sensing operational amplifier. this feedback preferably comprises a resistor connected between the output and input of the operational amplifier. The novelty of the invention resides in providing positive feedback such that switching of the operational amplifier is synchronized with switching of the voltage across the thyristor. The invention provides a solution to problems associated with high common mode voltage and enables use of lower cost components than would be required by other approaches.

Nola, F. J.↗

Power-Factor Controllers: How Safe?

Potential safety problems with power-factor controllers (PFC's) evaluated. Based on study of PFCs in use with appliances, report recommends measures to prevent consumers from misapplying these energy saving devices. Device used on such appliances as refrigerators, sewing machines, pumps, hair dryers, and food processors. When misused, they fail to save energy and may cause damage.

Long, K.↗

Review and investigation of unsatisfactory control characteristics involving in stability of pilot-airplane combination and methods for predicting these difficulties from ground tests

A number of examples are presented of control difficulties not completely covered by existing handling-qualities requirements. 520/3:*:These control difficulties appear to result from a tendency for dynamic instability of the combination of pilot, control system, and airplane. The unsatisfactory characteristics involved have been encountered most frequently with hydraulic-power control systems. The nature of the difficulties may range from a slight interference with the ability of the pilot to hold precisely straight and level flight to a dangerous tendency toward divergent short-period oscillations which require constant attention of the pilot to control. Tests of a bomber and a fighter airplane with experimental power control systems have been made to study this problem further. The results of the investigation show that control difficulties of the type considered have always been associated with a marked phase difference between the pilot's control force and the associated control-surface deflection. The presence of static friction in the control valves of hydraulic-power control systems was found to be the explanation for unsatisfactory characteristics in several airplanes equipped with such systems. The valve friction may cause a phase lag between the pilot's control force and the associated control-surface deflection approaching 180 degrees at small control deflections. Definite limits or simple rules for the tolerable amount of valve friction appear to be difficult to establish because of the large number of variables which may influence the problem.The control characteristics of the airplanes tested were strongly influenced by minor design details of the power control systems.

Phillips, William H↗