Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POLYVINYLS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Polymer thin films as universal substrates for extreme ultraviolet absorption spectroscopy of molecular transition metal complexes

Polystyrene and polyvinyl chloride thin films are explored as sample supports for extreme ultraviolet (XUV) spectroscopy of molecular transition metal complexes. Thin polymer films prepared by slip-coating are flat and smooth, and transmit much more XUV light than silicon nitride windows. Analytes can be directly cast onto the polymer surface or co-deposited within it. The M-edge XANES spectra (40–90 eV) of eight archetypal transition metal complexes (M = Mn, Fe, Co, Ni) are presented to demonstrate the versatility of this method. The films are suitable for pump/probe transient absorption spectroscopy, as shown by the excited-state spectra of Fe(bpy) 3 2+ in two different polymer supports.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Capture-gated Spectroscopic Measurements of Monoenergetic Neutrons with a Composite Scintillation Detector

Abstract—We report on the measurements of Monoenergetic neutrons from DD and DT fusion reactions by use of the capture gating method in a heterogeneous plastic-glass composite scintillation detector. The cylindrical detector is 5.08 cm in diameter and 5.05 cm in height and was fabricated using 1-mm diameter Li-doped glass rods(GS20) and scintillating polyvinyl toluene (EJ-290). Different scintillation decay constants are used to identify energy depositions in two materials constituting the composite scintillator. Geant4 simulations of the neutron thermalization and capture process were conducted, finding a mean capture time of approximately 2.6 ms for both DD and DT neutrons. A capture gating time acceptance window based on simulation results was used to identify the neutron thermalization pulses. The total scintillation light yield produced in neutron thermalization was measured and found to show consistency on event-by-event basis despite the variety of neutron thermalization histories prior to capture. The ratio of light yields from thermalization of 14.1 MeV and 2.45 MeV neutrons in the EJ-290 scintillator was determined to be 14.6, and the light output from 2.45 MeV neutrons was also correlated to its electron equivalent, obtaining a value of 0.58*0.05 MeVee.

47 OTHER INSTRUMENTATION↗

Simulated X-Ray Radiographic Performance of a Bismuth-Loaded PVT Array

Recent material advancements in organic plastic scintillators enable marked increases in material detection efficiency, light yield, and pulse shape discrimination properties. These advances may resolve significant capability gaps for lowcost, portable, and durable dual-particle imaging (DPI) systems for nuclear safety, security, and safeguard purposes. One such material, a 21% bismuth-loaded polyvinyl toluene (BiPVT), is computationally evaluated as a small, pixelated radiographic array using Monte Carlo N-Particle (MCNP) and Zemax OpticStudio, and it is compared to identical evaluations of EJ-200 and EJ-256 arrays. MCNP software enables estimates of particle interaction and energy deposition, while OpticStudio computes optical light transport within each material. Here, computational estimates of spatial resolution and relative light collection at 370 kVp are found to agree with experimental results for both EJ-200 and EJ-256 arrays, thereby validating predictions of the same for the BiPVT array. As such, for equivalent exposures at 370 kVp, a BiPVT array may provide ~20× the light collection expected from EJ-200 and ~10× that expected from EJ-256. Similar comparisons of estimated light collection are also computed at 150 and 270 kVp, and these results suggest that BiPVT will provide significantly improved performance over EJ-200 and EJ-256 across all energies practical for portable X-ray radiography.

42 ENGINEERING↗

In Vitro Thrombogenicity Testing of Biomaterials in a Dynamic Flow Loop: Effects of Length and Quantity of Test Samples

Abstract The results of in vitro dynamic thrombogenicity testing of biomaterials and medical devices can be significantly impacted by test conditions. To develop and standardize a robust dynamic in vitro thrombogenicity tool, the key test parameters need to be appropriately evaluated and optimized. We used a flow loop test system previously developed in our laboratory to investigate the effects of sample length and the number of samples per test loop on the thrombogenicity results. Porcine blood heparinized to a donor-specific target concentration was recirculated at room temperature through polyvinyl chloride (PVC) tubing loops containing test materials for 1 h at 200 mL/min. Four test materials (polytetrafluoroethylene (PTFE), latex, PVC, and silicone) with various thrombotic potentials in two sample lengths (12 and 18 cm) were examined. For the 12-cm long materials, two different test configurations (one and two samples per loop) were compared. Thrombogenicity was assessed through percent thrombus surface coverage, thrombus weight, and platelet count reduction in the blood. The test system was able to effectively differentiate the thrombogenicity profile of the materials (latex > silicone > PVC ≥ PTFE) at all test configurations. Increasing test sample length by 50% did not significantly impact the test results as both 12 and 18 cm sample lengths were shown to equally differentiate thrombotic potentials between the materials. The addition of a second test sample to each loop did not increase the test sensitivity and may produce confounding results, and thus a single test sample per loop is recommended.

Engineering↗

Potential of dual-energy subtraction for converting CT numbers to electron density based on a single linear relationship

Purpose: The conversion of the computed tomography (CT) number to electron density is one of the main processes that determine the accuracy of patient dose calculations in radiotherapy treatment planning. However, the CT number and electron density of tissues cannot be generally interrelated via a simple one-to-one correspondence because the CT number depends on the effective atomic number as well as the electron density. The purpose of this study is to present a simple conversion from the energy-subtracted CT number ({Delta}HU) by means of dual-energy CT (DECT) to the relative electron density ({rho}{sub e}) via a single linear relationship. Methods: The {Delta}HU-{rho}{sub e} conversion method was demonstrated by performing analytical DECT image simulations that were intended to imitate a second-generation dual-source CT (DSCT) scanner with an additional tin filtration for the high-kV tube. The {Delta}HU-{rho}{sub e} calibration line was obtained from the image simulation with a 33 cm-diameter electron density calibration phantom equipped with 16 inserts including polytetrafluoroethylene, polyvinyl chloride, and aluminum; the elemental compositions of these three inserts were quite different to those of body tissues. The {Delta}HU-{rho}{sub e} conversion method was also applied to previously published experimental CT data, which were measured using two different CT scanners, to validate the clinical feasibility of the present approach. In addition, the effect of object size on {rho}{sub e}-calibrated images was investigated by image simulations using a 25 cm-diameter virtual phantom for two different filtrations: with and without the tin filter for the high-kV tube. Results: The simulated {Delta}HU-{rho}{sub e} plot exhibited a predictable linear relationship over a wide range of {rho}{sub e} from 0.00 (air) to 2.35 (aluminum). Resultant values of the coefficient of determination, slope, and intercept of the linear function fitted to the data were close to those of the ideal case. The maximum difference between the ideal and simulated {rho}{sub e} values was -0.7%. The satisfactory linearity of {Delta}HU-{rho}{sub e} was also confirmed from analyses of the experimental CT data. In the experimental cases, the maximum difference between the nominal and simulated {rho}{sub e} values was found to be 2.5% after two outliers were excluded. When compared with the case without the tin filter, the {Delta}HU-{rho}{sub e} conversion performed with the tin filter yielded a lower dose and more reliable {rho}{sub e} values that were less affected by the object-size variation. Conclusions: The {Delta}HU-{rho}{sub e} calibration line with a simple one-to-one correspondence would facilitate the construction of a well-calibrated {rho}{sub e} image from acquired dual-kV images, and currently, second generation DSCT may be a feasible modality for the clinical use of the {Delta}HU-{rho}{sub e} conversion method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-BRF-04: Registration of 3D Transesophageal Echocardiography and X-Ray Fluoroscopy Using An Inverse Geometry X-Ray System

Purpose: To develop a method for the fusion of 3D echocardiography and Scanning-Beam Digital X-ray (SBDX) fluoroscopy to assist with catheter device and soft tissue visualization during interventional procedures. Methods: SBDX is a technology for low-dose inverse geometry x-ray fluoroscopy that performs digital tomosynthesis at multiple planes in real time. In this study, transesophageal echocardiography (TEE) images were fused with SBDX images by estimating the 3D position and orientation (the “pose”) of the TEE probe within the x-ray coordinate system and then spatially transforming the TEE image data to match this pose. An initial pose estimate was obtained through tomosynthesis-based 3D localization of points along the probe perimeter. Position and angle estimates were then iteratively refined by comparing simulated projections of a 3D probe model against SBDX x-ray images. Algorithm performance was quantified by imaging a TEE probe in different known orientations and locations within the x-ray field (0-30 degree tilt angle, up to 50 mm translation). Fused 3D TEE/SBDX imaging was demonstrated by imaging a tissue-mimicking polyvinyl alcohol cylindrical cavity as a catheter was navigated along the cavity axis. Results: Detected changes in probe tilt angle agreed with the known changes to within 1.2 degrees. For a 50 mm translation along the source-detector axis, the detected translation was 50.3 mm. Errors for in-plane translations ranged from 0.1 to 0.9 mm. In a fused 3D TEE/SBDX display, the catheter device was well visualized and coincident with the device shadow in the TEE images. The TEE images portrayed phantom boundaries that were not evident under x-ray. Conclusion: Registration of soft tissue anatomy derived from TEE imaging and device imaging from SBDX x-ray fluoroscopy is feasible. The simultaneous 3D visualization of these two modalities may be useful in interventional procedures involving the navigation of devices to soft tissue anatomy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-75: A Simple Technique for Proton Beam Range Verification

Purpose: To develop a measurement-based technique to verify the range of proton beams for quality assurance (QA). Methods: We developed a simple technique to verify the proton beam range with in-house fabricated devices. Two separate devices were fabricated; a clear acrylic rectangular cuboid and a solid polyvinyl chloride (PVC) step wedge. For efficiency in our clinic, we used the rectangular cuboid for double scattering (DS) beams and the step wedge for pencil beam scanning (PBS) beams. These devices were added to our QA phantom to measure dose points along the distal fall-off region (between 80% and 20%) in addition to dose at mid-SOBP (spread out Bragg peak) using a two-dimensional parallel plate chamber array (MatriXX™, IBA Dosimetry, Schwarzenbruck, Germany). This method relies on the fact that the slope of the distal fall-off is linear and does not vary with small changes in energy. Using a multi-layer ionization chamber (Zebra™, IBA Dosimetry), percent depth dose (PDD) curves were measured for our standard daily QA beams. The range (energy) for each beam was then varied (i.e. ±2mm and ±5mm) and additional PDD curves were measured. The distal fall-off of all PDD curves was fit to a linear equation. The distal fall-off measured dose for a particular beam was used in our linear equation to determine the beam range. Results: The linear fit of the fall-off region for the PDD curves, when varying the range by a few millimeters for a specific QA beam, yielded identical slopes. The calculated range based on measured point dose(s) in the fall-off region using the slope resulted in agreement of ±1mm of the expected beam range. Conclusion: We developed a simple technique for accurately verifying the beam range for proton therapy QA programs.

60 APPLIED LIFE SCIENCES↗

Energy dependent response of plastic scintillation detectors to photon radiation of low to medium energy

Purpose: Plastic scintillation detectors are promising candidates for the dosimetry of low- to medium-energy photons but quantitative knowledge of their energy response is a prerequisite for their correct use. The purpose of this study was to characterize the energy dependent response of small scintillation detectors (active volume <1 mm{sup 3}) made from the commonly used plastic scintillator BC400. Methods: Different detectors made from BC400 were calibrated at a number of radiation qualities ranging from 10 to 280 kV and at a {sup 60}Co beam. All calibrations were performed at the Physikalisch-Technische Bundesanstalt, the National Metrology Institute of Germany. The energy response in terms of air kerma, dose to water, and dose to the scintillator was determined. Conversion factors from air kerma to dose to water and to dose to the scintillator were derived from Monte Carlo simulations. In order to quantitatively describe the energy dependence, a semiempirical model known as unimolecular quenching or Birks’ formula was fitted to the data and from this the response to secondary electrons generated within the scintillator material BC400 was derived. Results: The detector energy response in terms of air kerma differs for different scintillator sizes and different detector casings. It is therefore necessary to take attenuation within the scintillator and in the casing into account when deriving the response in terms of dose to water from a calibration in terms of air kerma. The measured energy response in terms of dose to water for BC400 cannot be reproduced by the ratio of mean mass energy-absorption coefficients for polyvinyl toluene to water but shows evidence of quenching. The quenching parameter kB in Birks’ formula was determined to be kB = (12.3 ± 0.9) mg MeV{sup −1} cm{sup −2}. Conclusions: The energy response was quantified relative to the response to {sup 60}Co which is the common radiation quality for the calibration of therapy dosemeters. The observed energy dependence could be well explained with the assumption of ionization quenching as described by Birks’ formula. Plastic scintillation detectors should be calibrated at the same radiation quality that they will be used at and changes of the spectrum within the application need to be considered. The authors results can be used to evaluate the range of validity of a given calibration.

60 APPLIED LIFE SCIENCES↗

TH-CD-206-08: An Anthropopathic Deformable Phantom for Geometric and Dose Accumulation Accuracy Validation of Deformable Image Registration

Purpose: To design and construct a three-dimensional (3D) anthropopathic abdominal phantom for evaluating deformable image registration (DIR) accuracy on images and dose deformation in adaptive radiation therapy (ART). Method: Organ moulds, including liver, kidney, spleen, stomach, vertebra and two metastasis tumors, are 3D printed using the contours from an ovarian cancer patient. The organ moulds are molded with deformable gels that made of different mixtures of polyvinyl chloride (PVC) and the softener dioctyl terephthalate. Gels with different densities are obtained by a polynomial fitting curve which describes the relation between the CT number and PVC-softener blending ratio. The rigid vertebras are constructed by moulding with white cement. The final abdominal phantom is assembled by arranging all the fabricated organs inside a hollow dummy according to their anatomies and sealed with deformable gel with averaged CT number of muscle and fat. Geometric and dosimetric landmarks are embedded inside the phantom for spatial accuracy and dose accumulation accuracy studies. Three DIR algorithms available in the open source DIR toolkit-DIRART, including the Demons, the Horn-Schunck and Lucas-Kanade method and the Level-Set Motion method, are tested using the constructed phantom. Results: Viscoelastic behavior is observed in the constructed deformable gel, which serves as an ideal material for the deformable phantom. The constructed abdominal phantom consists of highly realistic anatomy and the fabricated organs inside have close CT number to its reference patient. DIR accuracy studies conducted on the constructed phantom using three DIR approaches indicate that geometric accuracy of a DIR algorithm has achieved does not guarantee accuracy in dose accumulation. Conclusions: We have designed and constructed an anthropopathic abdominal deformable phantom with satisfactory elastic property, realistic organ density and anatomy. This physical phantom is recyclable and can be used for routine validations of DIR geometric accuracy and dose accumulation accuracy in ART. This work is supported in part by grant from VARIAN MEDICAL SYSTEMS INC, the National Natural Science Foundation of China (no 81428019 and no 81301940), the Guangdong Natural Science Foundation (2015A030313302) and the 2015 Pearl River S&T Nova Program of Guangzhou (201506010096).

60 APPLIED LIFE SCIENCES↗

Stress-controlled medium-amplitude oscillatory shear (MAOStress) of PVA–Borax

We report the first-ever complete measurement of MAOStress material functions, which reveal that stress can be more fundamental than strain or strain rate for understanding linearity limits as a function of Deborah number. The material used is a canonical viscoelastic liquid with a single dominant relaxation time: polyvinyl alcohol (PVA) polymer solution cross-linked with tetrahydroborate (Borax) solution. We outline experimental limit lines and their dependence on geometry and test conditions. These MAOStress measurements enable us to observe the frequency dependence of the weakly nonlinear deviation as a function of stress amplitude. The observed features of MAOStress material functions are distinctly simpler than MAOStrain, where the frequency dependence is much more dramatic. The strain-stiffening transient network model was used to derive a model-informed normalization of the nonlinear material functions that accounts for their scaling with linear material properties. Moreover, we compare the frequency dependence of the critical stress, strain, and strain-rate for the linearity limit, which are rigorously computed from the MAOStress and MAOStrain material functions. While critical strain and strain-rate change by orders of magnitude throughout the Deborah number range, critical stress changes by a factor of about 2, showing that stress is a more fundamental measure of nonlinearity strength. This work extends the experimental accessibility of the weakly nonlinear regime to stress-controlled instruments and deformations, which reveal material physics beyond linear viscoelasticity but at conditions that are accessible to theory and detailed simulation.

Mechanics↗

Defects vibrations engineering for enhancing interfacial thermal transport in polymer composites

To push upper boundaries of thermal conductivity in polymer composites, understanding of thermal transport mechanisms is crucial. Despite extensive simulations, systematic experimental investigation on thermal transport in polymer composites is limited. To better understand thermal transport processes, we design polymer composites with perfect fillers (graphite) and defective fillers (graphite oxide), using polyvinyl alcohol (PVA) as a matrix model. Measured thermal conductivities of ~1.38 ± 0.22 W m -1 K -1 in PVA/defective filler composites is higher than those of ~0.86 ± 0.21 W m -1 K -1 in PVA/perfect filler composites, while measured thermal conductivities in defective fillers are lower than those of perfect fillers. We identify how thermal transport occurs across heterogeneous interfaces. Thermal transport measurements, neutron scattering, quantum mechanical modeling, and molecular dynamics simulations reveal that vibrational coupling between PVA and defective fillers at PVA/filler interfaces enhances thermal conductivity, suggesting that defects in polymer composites improve thermal transport by promoting this vibrational coupling.

42 ENGINEERING↗

Integrated low-temperature PVC and polyolefin upgrading

Polyolefins and their chlorinated derivatives such as polyvinyl chloride (PVC) are among the most prevalent plastics in global production and waste streams. Traditional waste-to-energy methods such as incineration and pyrolysis, as well as most chemical upcycling methods for PVC utilization, require thorough, high-temperature dechlorination to prevent the release of toxic chlorinated compounds. Here, we present here a strategy for upgrading discarded PVC into chlorine-free fuel range hydrocarbons and hydrogen chloride in a single-stage process catalyzed by chloroaluminate ionic liquids. This approach offsets endothermic dechlorination and carbon-carbon bond cleavage with exothermic alkylation and hydrogen transfer by isobutane or isopentane in a low-temperature tandem process. The light isoalkanes are available from refinery processes and partly from recycling of the product stream. This process is suitable for handling real-world mixed and contaminated PVC and polyolefin waste streams.

Zhang, Wei [East China Normal Univ. (ECNU), Shangh↗

Synthesis of functional materials in combustion reactions

The conditions for obtaining oxide compounds in combustion reactions of nitrates of metals with organic chelating–reducing agents such as amino acids, urea, and polyvinyl alcohol are reviewed. Changing the nature of internal fuels and the reducing agent-to-oxidizing agent ratio makes possible to modify the thermal regime of the process, fractal dimensionality, morphology, and dispersion of synthesized functional materials. This method can be used to synthesize simple and complex oxides, composites, and metal powders, as well as ceramics and coatings. The possibilities of synthesis in combustion reactions are illustrated by examples of αand γ-Al{sub 2}O{sub 3}, YSZ composites, uranium oxides, nickel powder, NiO and NiO: YSZ composite, TiO{sub 2}, and manganites, cobaltites, and aluminates of rare earth elements.

36 MATERIALS SCIENCE↗

Specific features of ZnCdS nanoparticles synthesized in different solvents

Stable colloidal solutions of ZnCdS nanoparticles (3–6 nm in diameter) in polyvinyl alcohol, polyethylene glycol, and H{sub 2}O are produced. The size of the synthesized nanoparticles is independent of the relation between precursors. It is shown that stabilization of the particles is defined by the charge-stability factor and can be attained without any additional stabilizing additives. The ZnCdS quantum dots synthesized emit in a wide spectral range from 450 to 600 nm.

36 MATERIALS SCIENCE↗

On a Possibility of the Overgrowth of Diamonds in the Hydrocarbon Atmosphere

The possibility to increase sizes of diamond crystals at least 25 μm by means of their annealing at a temperature of 1450 K in a hydrocarbon atmosphere has been studied. The initial diamond crystals are incorporated in the polyvinyl acetate layer on the surface of a silicon monocrystal and subjected to the annealing in methane atmosphere with low pressure in the presence of an external electric field with intensity up to 0.04 V/μm. Under these conditions the charged ions of methane dissociation products are accelerated and acquire the kinetic energy that is comparable with energy sufficient to form sp{sup 3}-hybride bonds, which can lead to an increase in the sizes of initial seed crystallites. The obtained substrates of a composite with a typical thickness not higher than 1.2 mm, which contain a joined diamond crystal in the carbon matrix, can be used as thermal conductive and electrical insulating spacers in devices for cooling items of electronic engineering.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diurnal observations of basal stem CO2 efflux in three canopy dominant trees in the central Amazon

We explored mechanisms responsible for disturbance-induced shifts in carbon metabolism in forests north of Manaus, Brazil (S2º 38' 17", W60º 09' 25"), using data from a selective logging experiment (BIONTE). BIONTE (the BIOmass and NuTrient Experiment) selective logging treatments were initiated in the mid-1980s and comprised variable removal of commercial tree (not total) species basal area (T1 =32%, T2 = 42%, T3 = 69%), and control plots with no logging (T0). Raw data including tree base diameter (Db), CO2 concentration versus time inside a static stem chamber, and wood density were used to derive stem respiration rates (Rw), wood production rates (Pw), and wood carbon use efficiency (CUE). Changes in tree base diameter (Db; measured at 1.3 m height, or above the buttresses) was used to calculate wood production for individual trees (Pw). Wood density enabled calculation of stem growth rate in the same units as stem respiration (mmol C m-2 s-1). Four trees were randomly selected from five tree growth rate classes for each treatment block, for a total of 20 trees per treatment block, or 80 trees total from the BIONTE plots. Each of the 80 trees selected for the Rw study were outfitted with dendrometer bands (da Silva et al. 2002). Stem respiration was measured using the method described in Chambers et al. (2004). Briefly, an infra-red gas analyzer (LiCor 820) was operated as a closed dynamic chamber with a flow rate of 1.0 L min-1. Polyvinyl chloride (PVC) semi-cylindrical chambers (250–400 mL) were secured to the tree stem near the dendrometer bands using nylon straps. The measurement interval spanned 1–2 min, and the CO2 flux from the stem of each tree was quantified using the enclosed stem area and slope of the stem CO2 concentration versus time.

54 ENVIRONMENTAL SCIENCES↗

Synthesis and characterization of polylactic acid microspheres via emulsion-based processing

Polylactic acid (PLA) microspheres are primarily used in drug delivery applications and rarely manufactured commercially. In encapsulation, the drug encapsulation and microsphere synthesis process happen simultaneously. Simultaneous synthesis necessitates conditions that ensure the drugs to be encapsulated remain viable in the synthesis process. Here, in the present work, solid pure PLA microspheres are prepared using a repeatable centrifugal mixing method to create a single emulsion system. A planetary thinky mixer is used to achieve centrifugal mixing. PLA acts as the dispersed phase of the emulsion, whereas Polyvinyl alcohol (emulsifier) dissolved in deionized water serves as the bulk phase. The emulsions are stirred for about 4 min at 2000 rpm. Microspheres prepared by mechanical mixing are compared with microspheres prepared by centrifugal mixing. The microspheres prepared by centrifugal mixing proved to be narrower and closer to a normal distribution with a mean size (D x 50) of 30 microns. The size distribution of planetary mixed microspheres did not change from one batch to another.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cleareye In-Ground and In-Concrete DIV Inspections: FY11 Final Report

This report summarizes the results of a series of feasibility testing studies for in-ground and in-concrete imaging/detection technologies including radar imaging and acoustic time-of flight method. The objectives of this project are: (1) Design Information Verification (DIV) Tools for In-Concrete Inspections - To determine the feasibility of using holographic radar imaging (HRI), radar imaging, and acoustic time-of-flight (TOF) non-destructive evaluation technologies to detect, locate and identify pipes and voids embedded in standard-density and high-density concrete walls that typify those the IAEA will need to verify during field inspections; (2) DIV Tools for In-Ground Inspections - To determine the feasibility of using HRI and radar imaging non-destructive evaluation technologies to detect, locate, and identify objects buried at various depths made of various materials (metal, plastic, wood, and concrete) and representing geometries that typify those the IAEA will need to verify during field inspections; and (3) Based on the results of the studies, recommend the next steps needed to realize fieldable tools for in-concrete and in-ground inspections (including detection of deeply buried polyvinyl chloride [PVC] pipes) that employ the technologies shown to be feasible.

09 BIOMASS FUELS↗