Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POLYETHYLENE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Friction and wear of polyethylene oxide polymer having a range of molecular weights

Sliding friction and wear experiments were conducted at light loads (25 to 250 g) with various molecular weights of the polyethylene oxide polymer sliding on itself and iron. Results of the experimental investigation indicate that: (1) the coefficient of friction for the polymer decreases with increasing molecular weight; (2) friction coefficient is higher for the polymer sliding on itself than it is for the polymer sliding on iron; (3) at sufficiently high loads localized surface melting occurs and the friction coefficient is the same for the polymer sliding on itself and iron; (4) fracture cracks develop in the sliding wear track at higher but not lower sliding velocities, reflecting a strain rate sensitivity to crack initiation, and (5) the friction coefficient for the polymer sliding on iron increases with the formation of a polymer film on the iron surface.

Buckley, D. H.↗

Strain-rate/temperature behavior of high density polyethylene in compression

The compressive strain rate/temperature behavior of highly linear, high density polyethylene was analyzed in terms of the predictive relations developed for metals and other crystalline materials. For strains of 5 percent and above, the relationship between applied strain rate, dotted epsilon, and resulting flow stress, sigma, was found to be: dotted epsilon exp times (Q sub f/RT) = k'(sigma/sigma sub c) to the nth power; the left-hand side is the activation-energy-compensated strain rate, where Q sub f is activation energy for flow, R is gas constant, and T is temperature; k is a constant, n is temperature-independent stress exponent, and sigma/sigma sub c is structure-compensated stress. A master curve resulted from a logarithmic plot of activation-energy-compensated strain rate versus structure-compensated stress.

Clements, L. L.↗

Effect of sterilization irradiation on friction and wear of ultrahigh-molecular-weight polyethylene

The effect of sterilization gamma irradiation on the friction and wear properties of ultrahigh molecular weight polyethylene (UHMWPE) sliding against 316L stainless steel in dry air at 23 C was determined. A pin-on-disk apparatus was used. Experimental conditions included a 1-kilogram load, a 0.061- to 0.27-meter-per-second sliding velocity, and a 32000- to 578000-meter sliding distance. Although sterilization doses of 2.5 and 5.0 megarads greatly altered the average molecular weight and the molecular weight distribution, the friction and wear properties of the polymer were not significantly changed.

Jones, W. R., Jr.↗

Effect of pyrolysis temperature on toxicity of gases from a polyethylene polymer

A polyethylene polymer was evaluated for time of toxic effect to occur as the result of exposure to gases generated by pyrolysis at various temperatures, using the toxicity screening test method developed at the University of San Francisco. Times to various animal responses decreased with increasing pyrolysis temperature over the range from 400 C to 800 C. Responses at a pyrolysis temperature of 350 C were more rapid than would be expected from the other data, and may indicate the predominance of different pyrolysis reactions in this particular temperature region.

Hilado, C. J.↗

Development of optimum process for electron beam cross-linking of high density polyethylene thermal energy storage pellets, process scale-up and production of application qualities of material

The electron irradiation conditions required to prepare thermally from stable high density polyethylene (HDPE) were defined. The conditions were defined by evaluating the heat of fusion and the melting temperature of several HDPE specimens. The performance tests conducted on the specimens, including the thermal cycling tests in the thermal energy storage unit are described. The electron beam irradiation tests performed on the specimens, in which the total radiation dose received by the pellets, the electron beam current, the accelerating potential, and the atmospheres were varied, are discussed.

Salyer, I. O.↗

Nonlinear viscoelastic characterization of thin polyethylene film

In order to understand the state of stress and strain in a typical balloon fabricated from thin polyethylene film, experiment data in the literature reviewed. It was determined that the film behaves as a nonlinear viscoelasticity material and should be characterized accordingly. A simple uniaxial, nonlinear viscoelastic model was developed for predicting stress given a certain strain history. The simple model showed good qualitative agreement with results of constant rate, uniaxial accurately predicting stresses for cyclic strain histories typical of balloon flights. A program was outlined which will result in the development of a more complex nonlinear viscoelastic model.

Wilbeck, J. S.↗

Effect of gamma irradiation on the friction and wear of ultrahigh molecular weight polyethylene

The effect of sterilization gamma irradiation on the friction and wear properties of ultrahigh molecular weight polyethylene (UHMWPE) sliding against stainless steel 316L in dry air at 23 C is investigated, the results to be used in the development of artificial joints which are to surgically replace diseased human joints. A pin-on-disk sliding friction apparatus is used, a constant sliding speed in the range 0.061-0.27 m/s is maintained, a normal load of 1 kgf is applied with dead weight, and the irradiation dose levels are: 0, 2.5, and 5.0 Mrad. Wear and friction data and conditions for each of the ten tests are summarized, and include: (1) wear volume as a function of the sliding distance for the irradiation levels, (2) incremental wear rate, and (3) coefficient of friction as a function of the sliding distance. It is shown that (1) the friction and wear properties of UHMWPE are not significantly changed by the irradiation doses of 2.5 and 5.0 Mrad, (2) the irradiation increases the amount of insoluble gel as well as the amount of low molecular weight material, and (3) after run-in the wear rate is either steady or gradually decreases as a function of the sliding distance.

Jones, W. R.↗

Effect of sliding speed and contact stress on tribological properties of ultra-high-molecular-weight polyethylene

A pin on disk apparatus was used to investigate the effect of sliding speed on the friction, wear, and transfer film characteristics of hemispherically tipped AISI 440C high temperature (HT) stainless steel riders sliding against ultrahigh molecular weight polyethylene (UHMWPE) disks. The surface morphology of the wear track was studied to determine possible wear mechanisms. Geometry effects were determined by comparing the results to those of others who used different specimen configurations. The results indicate that sliding speed, sliding distance, contact stress, and specimen geometry can all markedly influence the tribological properties of UHMWPE.

Fusaro, R. L.↗

Friction, wear, transfer and wear surface morphology of ultra-high-molecular-weight polyethylene

Tribological studies at 25 C in a 50-percent-relative-humidity air atmosphere were conducted using hemispherically tipped 440 C HT (high temperature) stainless steel pins sliding against ultra-high-molecular-weight polyethylene (UHMWPE) disks. The results indicate that sliding speed, sliding distance, contact stress and specimen geometry can markedly affect friction, UHMWPE wear, UHMWPE transfer and the type of wear mechanisms that occur. Adhesion appears to be the predominant wear mechanism; but after long sliding distances at slow speeds, heavy ridges of transfer result which can induce fatigue-like wear on the UHMWPE disk wear track. In one instance, abrasive wear to the metallic pin was observed. This was caused by a hard particle embedded in the UHMWPE disk wear track.

Fusaro, R. L.↗

Structure and properties of polyethylene films used in heavy lift balloons

The following features of five polyethylene films used by NASA in the construction of heavy lift balloons have been examined: molecular weight, molecular weight distribution, branching, melting behavior, density, surface texture, birefringence, orientation of crystalline regions, unlaxial deformation in the machine and transverse directions, and the effect of sample geometry and strain rate on deformation behavior. The goal of this exploratory study was to determine whether there are significant differences in any of the above mentioned features, or combination of features between the films. The acquisition of such information is a first step towards determining whether there are any specific correlations between film characteristics and the incidence of catastrophic failure of balloons during ascent through the troposphere. This exploratory study has resulted in the identification of similarities and differences between various features of the films.

Khoury, F.↗

Friction, wear, transfer, and wear surface morphology of ultrahigh-molecular-weight polyethylene

Tribological studies at 25 C in a 50-percent-relative-humidity air atmosphere were conducted using hemispherically tipped 440 C HT (high temperature) stainless steel pins sliding against ultra-high-molecular-weight polyethylene (UHMWPE) disks. The results indicate that sliding speed, sliding distance, contact stress and specimen geometry can markedly affect friction, UHMWPE wear, UHMWPE transfer and the type of wear mechanisms that occur. Adhesion appears to be the predominant wear mechanism; but after long sliding distances at slow speeds, heavy ridges of transfer result which can induce fatigue-like wear on the UHMWPE disk wear track. In one instance, abrasive wear to the metallic pin was observed. This was caused by a hard particle embedded in the UHMWPE disk wear track.

Fusaro, R. L.↗

Cell separation by immunoaffinity partitioning with polyethylene glycol-modified Protein A in aqueous polymer two-phase systems

Previous work has shown that polyethylene glycol (PEG)-bound antibodies can be used as affinity ligands in PEG-dextran two-phase systems to provide selective partitioning of cells to the PEG-rich phase. In the present work it is shown that immunoaffinity partitioning can be simplified by use of PEG-modified Protein A which complexes with unmodified antibody and cells and shifts their partitioning into the PEG-rich phase, thus eliminating the need to prepare a PEG-modified antibody for each cell type. In addition, the paper provides a more rigorous test of the original technique with PEG-bound antibodies by showing that it is effective at shifting the partitioning of either cell type of a mixture of two cell populations.

Karr, Laurel J.↗

12-crown-4 ether-assisted enhancement of ionic conductivity and interfacial kinetics in polyethylene oxide electrolytes

The electrical and electrochemical properties of thin films of polyethylene oxide electrolytes with and without 12-crown-4 ether (12Cr4) are studied as a function of temperature and in the frequency regime from 100 kHz to 0.1 Hz. These measurements were made on electrolytes containing LiCF3SO3, LiBF4, or LiClO4 salts. At a given temperature, the bulk conductivity for a particular salt depends on the 12Cr4 concentration, reaching a maximum for a ratio of 12Cr4 to Li of 0.003.

Nagasubramanian, G.↗

Effects of 12-Crown-4 ether on the ionic conductivity and electrode kinetics of electrolytes in polyethylene oxide

Results are described of investigations of the electrical and electrochemical properties of thin films of polyethylene oxide (PEO) electrolytes with and without 12-Crown-4 ether (12Cr4) as a function of temperature and in the frequency regime 100 kHz-0.1 Hz. These measurements were made for LiCF3SO3, LiBF4, and LiClO4 salts. At a given temperature, the bulk conductivity, sigma, (S/cm), for a particular salt, depends on the 12Cr4 concentration with sigma reaching a maximum at about 3 mM 12Cr4. Of the three salts studied, the sigma is the highest for PEO/LiBF4 with 3 mM 12Cr4. The ac and dc measurements yield a lower charge transfer resistance for 12Cr4-incorporated samples than for samples without. Plating/stripping of Li occurs at a potential closer to Li(+)/Li for 12Cr4 samples than those without. The conductivities of a thin (about 100 microns) and a thick (400 microns) films are similar.

Nagasubramanian, G.↗

Polyethylene Glycol Propionaldehydes

New class of compounds derived from polyethylene glycol (PEG's) namely, PEG-propionaldehydes, offers two important advantages over other classes of PEG aldehyde derivatives: compounds exhibit selective chemical reactivity toward amino groups and are stable in aqueous environment. PEG's and derivatives used to couple variety of other molecules, such as, to tether protein molecules to surfaces. Biotechnical and biomedical applications include partitioning of two phases in aqueous media; immobilization of such proteins as enzymes, antibodies, and antigens; modification of drugs; and preparation of protein-rejecting surfaces. In addition, surfaces coated with PEG's and derivatives used to control wetting and electroosmosis. Another potential application, coupling to aminated surfaces.

Harris, Joe M.↗

The elastic and yield behavior of polyethylene tubes subjected to biaxial loadings

The elastic and yield response of extruded thin-walled high-density polyethylene tubes with a density in the range of 0.961 to 0.964 gm/cu cm was investigated. Material properties in the axial and hoop directions were measured, and the tubes were found to be mildly transversely isotropic. The yield response was pressure sensitive, and was well predicted using the pressure-modified Hill criterion using a compressive to tensile yield strength ratio of 1:12.

Tuttle, M. E.↗

A study of the damage tolerance enhancement of carbon/epoxy laminates by utilizing an outer lamina of ultra high molecular weight polyethylene

The damage tolerance of carbon/epoxy was examined when an outer layer of ultra high molecular weight polyethylene (Spectra) material was utilized on the specimen. Four types of 16 ply quasi-isotropic panels, (0,+45,90,-45)s2 were tested. The first contained no Spectra, while the others had one lamina of Spectra placed on either the top (impacted side), bottom or both surfaces of the composite plate. A range of impact energies up to approximately 8.5 Joules (6.3 ft-lbs) was used to inflict damage upon these specimens. Glass/Phenolic honeycomb beams with a core density of 314 N/m3 (2.0 lb/ft3) and 8 ply quasi-isotropic facesheets were also tested for compression-after-impact strength with and without Spectra at impact energies of 1,2,3 and 4 Joules (.74, 1.47, 2.21 and 2.95 ft-lbs). It was observed that the composite plates had little change in damage tolerance due to the Spectra, while the honeycomb panels demonstrated a slight increase in damage tolerance when Spectra was added, the damage tolerance level being more improved at higher impact energies.

Nettles, Alan T.↗

Solving a product safety problem using a recycled high density polyethylene container

The objectives are to introduce basic problem-solving techniques for product safety including problem identification, definition, solution criteria, test process and design, and data analysis. The students are given a recycled milk jug made of high density polyethylene (HDPE) by blow molding. The objectives are to design and perform proper material test(s) so they can evaluate the product safety if the milk jug is used in a certain way which is specified in the description of the procedure for this investigation.

Liu, Ping↗