Electrical cable utilization for wave energy converters

Here, this paper investigates the suitability of sizing the electrical export cable based on the rating of the contributing WECs within a farm. These investigations have produced a new methodology to evaluate the probabilities associated with peak power values on an annual basis. It has been shown that the peaks in pneumatic power production will follow an exponential probability function for a linear model. A methodology to combine all the individual probability functions into an annual view has been demonstrated on pneumatic power production by a Backward Bent Duct Buoy (BBDB). These investigations have also resulted in a highly simplified and perfunctory model of installed cable cost as a function of voltage and conductor cross-section. This work solidifies the need to determine electrical export cable rating based on expected energy delivery as opposed to device rating as small decreases in energy delivery can result in cost savings.

16 TIDAL AND WAVE POWER↗

Correcting distortions of thin-walled machined parts by machine hammer peening

Thin-walled aerostructural components frequently get distorted after the machining process. Reworking to correct distortions or eventually rejecting parts significantly increases the cost. This paper proposes a new approach to correct distortions in thin-walled components by strategically applying hammer peening on target surfaces of a machined component. Aluminium alloy 7475-T7351 was chosen for this research. The study was divided in two stages. First, the residual stresses (RS) induced by four different pneumatic hammer peening conditions (modifying the stepover distance and initial offset) were characterised in a test coupon, and one of the conditions was selected for the next stage. In the second stage, a FEM model was used to predict distortions caused by machining in a representative workpiece. Then, the RS induced by hammer peening were included in an FEM model to define two hammer peening strategies (varying the coverage area) to analyse the capability to reduce distortions. Two workpieces were machined and then treated with the simulated hammer peening strategies for experimental validation. Results in the test coupon showed that pneumatic hammer peening can generate high compressive RS (-50 to –350 MPa) up to 800 μm depth, with their magnitude increasing with a reduced stepover distance. Application of hammer peening over 4% of the surface of the representative workpiece reduced the machining-induced distortions by 37%, and a coverage area of 100% led to and overcorrection by a factor of five. This confirms that hammer peening can be strategically applied (in target areas and changing the percentage of coverage) to correct low or severe distortions.

42 ENGINEERING↗

Fission Product Yields from 232Th, 238U, and 235U Using 14 MeV Neutrons

Neutron-induced fission yield studies using deuterium-tritium fusion-produced 14 MeV neutrons have not yet directly measured fission yields from fission products with half-lives on the order of seconds (far from the line of nuclear stability). Fundamental data of this nature are important for improving and validating the current models of the nuclear fission process. Cyclic neutron activation analysis (CNAA) was performed on three actinide targets–thorium-oxide, depleted uranium metal, and highly enriched uranium metal–at the University of Michigan's Neutron Science Laboratory (UM-NSL) using a pneumatic system and Thermo-Scientific D711 accelerator-based fusion neutron generator. This was done to measure the fission yields of short-lived fission products and to examine the differences between the delayed fission product signatures of the three actinides. The measured data were compared against previously published results for 89Kr, -90, and -92 and 138Xe, -139, and -140. The average percent deviation of the measured values from the Evaluated Nuclear Data Files VII.1 (ENDF/B-VII.1) for thorium, depleted-uranium, and highly-enriched uranium were -10.2%, 4.5%, and -12.9%, respectively. In addition to the measurements of the six known fission products, 23 new fission yield measurements from 84As to 146La are presented.

Pierson, Bruce D.↗

Cryogenic pellet production developments for long-pulse plasma operation

Long pulse plasma operation on large magnetic fusion devices require multiple forms of cryogenically formed pellets for plasma fueling, on-demand edge localized mode (ELM) triggering, radiative cooling of the divertor, and impurity transport studies. The solid deuterium fueling and ELM triggering pellets can be formed by extrusions created by helium cooled, twin-screw extruder based injection system that freezes deuterium in the screw section. A solenoid actuated cutter mechanism is activated to cut the pellets from the extrusion, inserting them into the barrel, and then fired by the pneumatic valve pulse of high pressure gas. Fuel pellets are injected at a rate up to 10 Hz, and ELM triggering pellets are injected at rates up to 20 Hz. The radiative cooling and impurity transport study pellets are produced by introducing impurity gas into a helium cooled section of a pipe gun where it deposits in-situ. A pneumatic valve is opened and propellant gas is released downstream where it encounters a passive punch which initially accelerates the pellet before the gas flow around the finishes the pellet acceleration. This paper discusses the various cryogenic pellet production techniques based on the twin-screw extruder, pipe gun, and pellet punch designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Online remote control systems for static and dynamic compression and decompression using diamond anvil cells

The ability to remotely control pressure in diamond anvil cells (DACs) in accurate and consistent manner at room temperature, and at cryogenic and elevated temperatures, is crucial for effective and reliable operation of a high-pressure synchrotron facility such as High Pressure Collaborative Access Team (HPCAT). Over the last several years, a considerable effort has been made to develop instrumentation for remote and automated pressure control in DACs during synchrotron experiments. We have designed and implemented an array of modular pneumatic (double-diaphragm), mechanical (gearboxes), and piezoelectric devices and their combinations for controlling pressure and compression/decompression rate at various temperature conditions from 4 K in cryostats to several thousand Kelvin in laser-heated DACs. Because HPCAT is a user facility and diamond cells for user experiments are typically provided by users, our development effort has been focused on creating different loading mechanisms and frames for a variety of existing and commonly used diamond cells rather than designing specialized or dedicated diamond cells with various drives. In this paper, we review the available instrumentation for remote static and dynamic pressure control in DACs and show some examples of their applications to high pressure research.

47 OTHER INSTRUMENTATION↗

Programmable soft valves for digital and analog control

In soft devices, complex actuation sequences and precise force control typically require hard electronic valves and microcontrollers. Existing designs for entirely soft pneumatic control systems are capable of either digital or analog operation, but not both, and are limited by speed of actuation, range of pressure, time required for fabrication, or loss of power through pull-down resistors. Using the nonlinear mechanics intrinsic to structures composed of soft materials—in this case, by leveraging membrane inversion and tube kinking—two modular soft components are developed: a piston actuator and a bistable pneumatic switch. These two components combine to create valves capable of analog pressure regulation, simplified digital logic, controlled oscillation, nonvolatile memory storage, linear actuation, and interfacing with human users in both digital and analog formats. Three demonstrations showcase the capabilities of systems constructed from these valves: 1) a wearable glove capable of analog control of a soft artificial robotic hand based on input from a human user’s fingers, 2) a human-controlled cushion matrix designed for use in medical care, and 3) an untethered robot which travels a distance dynamically programmed at the time of operation to retrieve an object. This work illustrates pathways for complementary digital and analog control of soft robots using a unified valve design.

42 ENGINEERING↗

Physiologically guided approach to characterizing respiratory motion

Purpose: To characterize radiation therapy patient breathing patterns based on measured external surrogate information. Methods: Breathing surrogate data were collected during 4DCT from a cohort of 50 patients including 28 patients with lung cancer and 22 patients without lung cancer. A spirometer and an abdominal pneumatic bellows were used as the surrogates. The relationship between these measurements was assumed to be linear within a small phase difference. The signals were correlated and drift corrected using a previously published method to convert the signal into tidal volume. The airflow was calculated with a first order time derivative of the tidal volume using a window centered on the point of interest and with a window length equal to the CT gantry rotation period. The airflow was compared against the tidal volume to create ellipsoidal patterns that were binned into 25 ml × 25 ml/s bins to determine the relative amount of time spent in each bin. To calculate the variability of the maximum inhalation tidal volume within a free-breathing scan timeframe, a metric based on percentile volume ratios was defined. The free breathing variability metric (κ) was defined as the ratio between extreme inhalation tidal volumes (defined as >93 tidal volume percentile of the measured tidal volume) and normal inhalation tidal volume (defined as >80 tidal volume percentile of the measured tidal volume). Results: There were three observed types of volume-flow curves, labeled Types 1, 2, and 3. Type 1 patients spent a greater duration of time during exhalation withκ = 1.37 ± 0.11. Type 2 patients had equal time duration spent during inhalation and exhalation with κ = 1.28 ± 0.09. The differences between the mean peak exhalation to peak inhalation tidal volume, breathing period, and the 85th tidal volume percentile for Type 1 and Type 2 patients were statistically significant at the 2% significance level. The difference between κ and the 98th tidal volume percentile for Type 1 and Type 2 patients was found to be statistically significant at the 1% significance level. Three patients did not display a breathing stability curve that could be classified as Type 1 or Type 2 due to chaotic breathing patterns. These patients were classified as Type 3 patients. Conclusions: Based on an observed volume-flow curve pattern, the cohort of 50 patients was divided into three categories called Type 1, Type 2, and Type 3. There were statistically significant differences in breathing characteristics between Type 1 and Type 2 patients. The use of volume-flow curves to classify patients has been demonstrated as a physiological characterization metric that has the potential to optimize gating windows in radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-12: An Image-Guided Soft Robotic Patient Positioning System for Maskless Head-And-Neck Cancer Radiotherapy: A Proof-Of-Concept Study

Purpose: We propose a surface-image-guided soft robotic patient positioning system for maskless head-and-neck radiotherapy. The ultimate goal of this project is to utilize a soft robot to realize non-rigid patient positioning and real-time motion compensation. In this proof-of-concept study, we design a position-based visual servoing control system for an air-bladder-based soft robot and investigate its performance in controlling the flexion/extension cranial motion on a mannequin head phantom. Methods: The current system consists of Microsoft Kinect depth camera, an inflatable air bladder (IAB), pressured air source, pneumatic valve actuators, custom-built current regulators, and a National Instruments myRIO microcontroller. The performance of the designed system was evaluated on a mannequin head, with a ball joint fixed below its neck to simulate torso-induced head motion along flexion/extension direction. The IAB is placed beneath the mannequin head. The Kinect camera captures images of the mannequin head, extracts the face, and measures the position of the head relative to the camera. This distance is sent to the myRIO, which runs control algorithms and sends actuation commands to the valves, inflating and deflating the IAB to induce head motion. Results: For a step input, i.e. regulation of the head to a constant displacement, the maximum error was a 6% overshoot, which the system then reduces to 0% steady-state error. In this initial investigation, the settling time to reach the regulated position was approximately 8 seconds, with 2 seconds of delay between the command start of motion due to capacitance of the pneumatics, for a total of 10 seconds to regulate the error. Conclusion: The surface image-guided soft robotic patient positioning system can achieve accurate mannequin head flexion/extension motion. Given this promising initial Result, the extension of the current one-dimensional soft robot control to multiple IABs for non-rigid positioning control will be pursued.

60 APPLIED LIFE SCIENCES↗

Auto Indexer Auto-Indexer for Percussive Hammers: Vane Motor Dynamometer Testing

Objectives Options associated with geothermal drilling operations are generally limited by factors such as formation temperature and rock strength. The objective of the research is to expand the "tool box" available to the geothermal driller by furthering the development of a high-temperature drilling motor that can be used in directional drilling applications for drilling high temperature geothermal formations. The motor is specifically designed to operate in conjunction with a pneumatic down-the-hole-hammer. It provides a more compact design compared to traditional drilling motors such as PDMs (positive displacement motors). The packaging can help to enhance directional drilling capabilities. It uses no elastomeric components, which enables it to operate in higher temperatures (greater than 250 degrees F). Current work on the motor has shown that is a capable of operating under pneumatic power with a down-the-hole-hammer. Further development work will include continued testing and refining motor components and evaluating motor capabilities. Targets/Milestones Complete testing current motor - 12/31/2010 Make final material and design decisions - 01/31/2011 Build and test final prototype - 04/31/2011 Final demonstration - 07/31/2011 Impacts The development of the motor will help to achieve program technical objectives by improving well construction capabilities. This includes enabling high-temperature drilling as well as enhancing directional drilling. A key component in the auto indexer is the drive motor. It is an air-driven vane motor that converts the energy stored in the compressed air to mechanical energy. The motor is attached to hammer-like components which impart an impulsive load onto the drive shaft. The impulsive force on the drive shaft in turn creates an indexing action. A controlled test was performed to characterize the performance of the the vane motor for a given pressure. The Sandia dynamometer test station was used to determine the performance of the motor for a given input pressure.

15 GEOTHERMAL ENERGY↗

Causal Analysis of the Inadvertent Contact with an Uncontrolled Electrical Hazardous Energy Source (120 Volts AC)

On September 25, 2013, a Health Physics Technician (HPT) was performing preparations to support a pneumatic transfer from the HFEF Decon Cell to the Room 130 Glovebox in HFEF, per HFEF OI 3165 section 3.5, Field Preparations. This activity involves an HPT setting up and climbing a portable ladder to remove the 14-C meter probe from above ball valve HBV-7. The HPT source checks the meter and probe and then replaces the probe above HBV-7, which is located above Hood ID# 130 HP. At approximately 13:20, while reaching past the HBV-7 valve position indicator switches in an attempt to place the 14-C meter probe in the desired location, the HPT’s left forearm came in contact with one of the three sets of exposed terminals on the valve position indication switches for HBV 7. This resulted in the HPT receiving an electrical shock from a 120 Volt AC source. Upon moving the arm, following the electrical shock, the HPT noticed two exposed electrical connections on a switch. The HPT then notified the HFEF HPT Supervisor, who in turn notified the MFC Radiological Controls Manager and HFEF Operations Manager of the situation. Work was stopped in the area and the hazard was roped off and posted to prevent access to the hazard. The HPT was escorted by the HPT Supervisor to the MFC Dispensary and then preceded to CFA medical for further evaluation. The individual was evaluated and released without any medical restrictions. Causal Factor (Root Cause) A3B3C01/A5B2C08: - Knowledge based error/Attention was given to wrong issues - Written Communication content LTA, Incomplete/situation not covered The Causal Factor (root cause) was attention being given to the wrong issues during the creation, reviews, verifications, and actual performance of HFEF OI-3165, which covers the need to perform the weekly source check and ensure placement of the probe prior to performing a “rabbit” transfer. This resulted in the hazard not being identified and mitigated in the procedure. Work activities with in HFEF-OI-3165 placed the HPT in proximity of an unmitigated hazard directly resulting in this event. Contributing Factor A3B3C04/A4B5C04: - Knowledge Based Error, LTA Review Based on Assumption That Process Will Not Change - Change Management LTA, Risks/consequences associated with change not adequately reviewed/assessed Prior to the pneumatic system being out of service, the probe and meter were not being source checked together. The source check issue was identified and addressed during the period of time when the system was out of service. The corrective actions for this issue resulted in the requirement that a meter and probe be source checked together as it is intended to be used. This changed the activity and required an HPT to weekly, when in use, remove and install the probe from above HBV-7 to meet the requirement of LRD 15001 Part 5 Article 551.5. Risks and consequences associated with this change were not adequately reviewed or assessed. Failure to identify the hazard associated with this change directly contributed to this event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated Component-Specific Measurements to Develop Emission Factors for Compressors and Gas Gathering Lines

The Department of Energy (DOE) National Energy Technology Laboratory (NETL) and other critical stakeholders (e.g., U.S. Environmental Protection Agency (USEPA), state regulators, and industry) seek to more accurately characterize and quantify methane emissions from compressors and gathering lines within the Gathering and Boosting (G&B) segment of the natural gas system network. These efforts will reduce uncertainties in emissions estimates in USEPA’s current Green House Gas Inventory (GHGI) under their Greenhouse Gas Reporting Program (GHGRP). For this study, four G&B stations in the Gulf Coast Area were visited four times over the course of one year. Components were classified according to equipment and component type and emissions from select components were measured using multiple measurement technologies. The following major equipment types were considered: i) compressors, ii) separators, iii) dehydrators, iv) coalescers, v) slug catchers, vi) yard piping, vii) tanks, and viii) gathering lines. Individual components on each equipment type were further divided into the following main categories: i) connectors, ii) valves, iii) pressure relief valves (PRV), iv) meters, v) gauges, vi) regulators, vii) pneumatic device vents, and viii) compressor vents (e.g., distance piece vents [DPVs] and rod packing vents [RPVs]). Components were screened for the presence of leaks and venting emissions with an optical gas imaging (OGI) camera, and methane emission rates were measured using a microdilution high volume sampler. Downwind emissions were measured using an Open Path Fourier Transform Infrared (OP-FTIR) Spectrometer. Data were evaluated to assess correlation with site, equipment, time, and operational variables. Key findings and recommendations from the study include: A) Different counting methodologies can result in vastly different component counts, thus influencing total emissions calculations using Subpart W population EFs. A standard methodology should be adopted for classifying and counting components in order to minimize inconsistencies across studies and instruct stakeholders responsible for GHGI reporting. B) Results support current component subcategories listed in USEPA Subpart W, including the subdivision of connectors (flanged and “other”) and pneumatic device vents (intermittent, continuous low bleed, and continuous high bleed). C) Emission rates vary across sites and a relationship between higher emissions and compressor age was observed for some components. D) Component emission rates varied between field campaigns. The type of components contributing to overall measured emissions also varied among field campaigns. However, the emission rate variability was larger between different components (of the same category) than the variability in one component over the four field campaigns. Therefore, when calculating emission factors, it is not necessary to take repeat measurements to capture component variability. E) Measuring the emission rate of a sample for an extended period of time is not necessary to capture the average component emission rate. F) For reporting purposes, excluding liquid lines from site-wide screening may have a negligible effect on component-related emissions. However, from a site management perspective, malfunctioning components were not uncommon on liquid lines and contributed substantially to fugitive emissions at some sites. G) Population EFs, whether including or excluding liquid lines, were a conservative estimate of fugitive emissions. Leaker EFs consistently underestimated emissions at the field sites. Measurements at more sites, particularity sites in other areas of the country, need to be completed before determining the accuracy of EFs.

03 NATURAL GAS↗

Top Loading Helium Cryostat Integrated with High-Pressure Cell with Fast Remote Pressure Control (Final Report for SBIR Phase 1)

A large number of physical phenomena, such as superconductivity and quantum critical phenomena, often appear only at very low temperatures below 5 K. There is an immense interest to investigate these phenomena at high pressure as a means of tuning interatomic distances, and thus the interaction parameters controlling these phenomena, in a continuous and controlled fashion. The current P-T condition for neutron scattering experiments are limited to either relatively low pressures of about 2 GPa at temperatures below 5 K, or to relatively high temperatures at pressures or tens of GPa. The purpose of this research is to develop neutron sample environment instrumentation for reaching 10-20 GPa at 1-2K with rapid and reliable online pressure and temperature control (i.e. without having to interrupt the experiment). The ultimate goal of the project is to design an integrated fast-cooling low-temperature sample environment cryogenic system compatible with state of the art neutron diamond anvil cells suitable for single-crystal neutron scattering experiments for temperatures down to 2K and pressures of several tens of GPa. The integrated system will consist of top-loading Helium flow cryostat with in-situ sample alignment mechanisms, large-volume diamond anvil cells (DAC) made from novel superalloy Pascalloy and optimized for fast cooling and heating, and a compact remote pressure control mechanism for the DAC based on a novel concept of inflatable bellows integrated with a lever-arm based force amplifier. In Phase I, we have designed, manufactured, and tested prototypes of the novel compact force-amplified pneumatic pressure control mechanism for Neutron Diamond Anvil Cell (nDAC), which allows to use pneumatic bellows system for smooth remote pressure control in the nDAC inside a top-loading cryostat with bore size of 70 mm or larger. This allows significant minimum temperature decrease in remotely controlled nDAC from 5-10 K down to 2 K. We also studied mechanical properties of a novel non-magnetic superalloy Pascalloy with different heat-treatment conditions and preliminary results indicate that up to date this is probably the strongest and most suitable material for making more compact and lightweight cryogenic nDACs for neuron scattering experiments at extreme conditions, allowing much faster cooling and heating. Potential applications: The new developments will allow to create a wide range of compact Diamond Anvil Cells for neutron diffraction which can reach several tens of GPA pressure at 2-4 K while preserving accurate remote pressure control capabilities. The new concepts can be used for developing sample environment instrumentation outside the neutron scattering field. The new development have very strong potential for expanding experimental capabilities in materials sciences and have high commercialization potential. The proposed new cryogenic high-pressure system or any of its individual components will be in high demand not only in neutron scattering facilities, but also at synchrotron beamlines and other high-pressure research facilities around the world.

36 MATERIALS SCIENCE↗

Methane Mitigation Thermoelectric Generator (MMTEG) (Final Scientific/ Technical Report)

Gas Technology Institute (GTI) has completed a $1.815M (plus $500K cost share), 54-month Co-operative agreement with the Department of Energy’s National Energy Technology Laboratory to develop a Methane Mitigation Thermoelectric Generator (MMTEG) system for gas field applications. This novel system uses fugitive gas to produce electrical power and consists of Thermoelectric Generators (TEG) driven by a linear burner, an air compressor, an accumulator, valves, batteries, and power electronics. The electrical power generated by the system is used to compress air and, in turn, the air is used to operate the pneumatic valves at the well site instead of using natural gas (NG) which would then be vented. The team completed the project objectives which included (1) Design, fabricate and test an integrated 6We nominal MMTEG prototype system, (2) Design a “retrofit kit” MMTEG system capable of being field tested at a gas well production site, and (3) build and test the field MMTEG system in a laboratory environment. Multiple system options were developed prior to selecting a “Passive” system which meets cost, NG savings, and greenhouse gas (GHG) reduction targets although not as efficient as initially planned. The MMTEG system is built primarily from commercial off-the-shelf parts (in some cases re-purposed) including the heat exchanger, heat rejection, electronic components, and also the TEGs. The team developed and implemented a novel system including the control system developed by Morrison Applied Sciences (MAS). The team completed incremental demonstrations of the hardware prior to the MMTEG system demonstration. A one-year simulation of the air delivery and battery charging subsystems was completed prior to the integration into the MMTEG system. In addition, the team simulated two-years of thermal cycles for integrated Burner/TEG/heat rejection subsystem. Finally, the entire MMTEG system was assembled, and troubleshooting was completed over a two-week period. Next, the MMTEG system was tested to simulate over 15 weeks of entire system operation over approximately four weeks in an accelerated test fashion with minimal intervention (such as changing fuel tanks). The MMTEG system met the key goals of a unit cost of under $1500 while saving 97% of NG expended today (including leakage) on average by pneumatic systems venting to the atmosphere. The MMTEG system reduced GHG emissions by 1000X (using the methane intensification factor of 28 relative to CO2). GTI is currently pursuing a field test of the MMTEG system. Interfacing with producers has provided additional insight into system improvements. Planned improvements include additional weather protection and control system improvements including the implementation of a long- range radio capability to notify operators if there is a fault.

03 NATURAL GAS↗

Predictive Self-Healing Seals for Gas Transmission

Damaged elastomeric diaphragms within pneumatic controllers used in the oil and gas industry lead to an unintended release of methane. Self-healing microvascular materials capable of healing various types of damage have been fabricated. These microvascular materials are designed to replace currently available commercial diaphragms found in pneumatic controllers and provide a solution to reduce unintended methane leaks. This project demonstrated the ability of these materials to reduce methane release by more than 80% in lab and pilot settings. Additionally, ML approaches successfully identified leaking systems based on training using synthetic and real data.

03 NATURAL GAS↗

Optimizing Hammermill Performance Through Screen Selection and Hammer Design

Background: Mechanical preprocessing, which includes particle size reduction and mechanical separation, is one of the primary operations in the feedstock supply system for a lignocellulosic biorefinery. It is the means by which raw biomass from the field or forest is mechanically transformed into an on-spec feedstock with characteristics better suited for the fuel conversion process. Results: This work provides a general overview of the objectives and methodologies of mechanical preprocessing and then presents experimental results illustrating (1) improved size reduction via optimization of hammer mill configuration, (2) improved size reduction via pneumatic-assisted hammer milling, and (3) improved control of particle size and particle size distribution through proper selection of grinder process parameters. Conclusion: Optimal grinder configuration for maximal process throughput and efficiency is strongly dependent on feedstock type and properties, such moisture content. Tests conducted using a HG200 hammer grinder indicate that increasing the tip speed, optimizing hammer geometry, and adding pneumatic assist can increase grinder throughput as much as 400%.

09 BIOMASS FUELS↗

Electropneumatic transducer automatically limits motor current

Pneumatic controller regulates the load on a centrifugal freon compressor in a water cooling system, thus limiting the current input to an electric motor driving it. An electromechanical transducer monitoring the motor input current sends out air signals which indicate changes in the current to the pneumatic controller.

Lovitt, T. F.↗

Actuator device schedules rate of valve closure

Prevalve actuator schedules the closure rate of a valve. The actuator is spring loaded to produce a normally open valve and pneumatically powered to close the valve. The closure rate is controlled by means of pneumatic snubber and booster circuitry.

Source record↗

Precision control system for engine fuel

System controls two or more pneumatically operated metering valves from common pneumatic source without interaction between valve controls. Unit affords independent metering of liquid from single source to two concurrent applications. Calibration and testing demonstrate complete absence of interaction between valves and corresponding flow rates.

Hawkins, D. E.↗