T-1065: Secondary Emitters Study

One possibility to make a fast and radiation resistant shower maximum (SM) detector or preshower detector is to use a secondary emitter (SE) as an active element. This method was proposed in 1990. Micro channel plates (MCP) were used as SE in the SM. The attractive properties of such SM are: 1) a two-dimensional map of energy at the SE location; 2) timing information at few tens of picosecond level, also as transverse shower size and 3) possible separation of electromagnetic and hadronic energy based on the differences of the shower size and timing. An electron-multiplier-based sampling calorimeter requires thin planar detectors at an affordable cost. Large-area photo detectors based on ALD-functionalized 20-cm-square borosilicate glass capillary micro-channel plates (MCPs), currently being developed by the LAPPD Collaboration, are candidates for the active elements. The first results of the new shower maximum detector with the micro channel plate photomultiplier (MCP-PMT) as active elements are described. The current proposal is the next natural step in this direction. The experimenters propose using large-area MCPs assembled without the usual bialkali photocathodes as the active element in sampling calorimeters. LAPPD modules without photocathodes can be economically assembled in a glove box and then pumped and sealed using the process to construct photomultipliers, bypassing the slow and expensive vacuum-transfer process required by bialkali photocathodes. The first use of electron multipliers, in this case MCPs (Fig. 1, left) as an active element in multi-layer sampling calorimeters is described. A chevron of two MCPs in vacuum, was located behind a tungsten plate on which 5 GeV and 26 GeV electrons were incident (Fig. 1, right). The amplitude of the MCP signal (Fig. 2) as a function of the tungsten thickness was measured. The primary electrons produce a shower of secondary particles, including positron-electron pairs and gammas; the response of the MCPs (Fig. 2, left) is proportional to the number of particles in the shower, which is dependent on the initial particle energy. The MCP signal shape is presented in the Fig. 2, right). The FWHM of the signal is 1 ns.

43 PARTICLE ACCELERATORS↗

T-1072: Beam test for muon strips

Beam test for muon strips is an experiment to measure the efficiency, time resolution and longitudinal position resolution of scintillator strips for a muon system at future colliders. The muon system at future colliders is envisioned as several layers of position-sensitive detectors embedded in the iron flux-return yoke of the solenoidal magnet. The role of the muon system is primarily the identification of muons and track matching to the central tracker, besides serving as the tail catcher for the hadronic showers that penetrate beyond the hadron calorimetry. Previous tests performed at Fermilab with cosmic muons have shown that scintillators with wavelength-shifting (WLS) fibers and a SiPM readout offer promising performance (NIM A 823, 2016, pp.120-125). The purpose of the present beam tests is to determine the performance parameters with better accuracy. The measurement setup is schematically presented in Fig. 1. The length of the tested strips will vary between 1 m and 2 m. The scintillator strip to be tested will be placed horizontally perpendicular to the beam on a platform in the area behind the beam dump of MT6.2. Two fast scintillators S1 and S2 with vacuum PMT readout will be placed in front and after the tested strip in the beam. The distance between S1 and S2 is 1 m. One fast scintillator strip S3 will be placed in beam immediately in front of the tested strip, perpendicular to the tested strip. A rack with a CAMAC crate and two NIM crates will be used for the data acquisition. The data collection will be performed and monitored from a PC with USB connection to the CAMAC Crate controller.

43 PARTICLE ACCELERATORS↗

Tagging Cosmic Ray Background in the Icarus Detector

ICARUS T-600 will be the Far Detector of the upcoming SBN program, for which it will leverage a ∼ 1ns response and a high resolution for neutrino event reconstruction. ICARUS will respond to the challenge of the cosmic flux at the surface thanks to its Cosmic Ray Tagging (CRT) system. The work conducted during the Summer Students at Fermilab program contributed to the calibration activities that are ongoing in view of the second physics run in late 2022: the timing of CRT and PMT signals was analysed, highlighting the need for corrections to the PMTs. The timing delay for the global trigger signal for a section of the side CRT. The possibility of calibrating the light yield of the side CRTs with run data was finally explored.

47 OTHER INSTRUMENTATION↗

Neutron Positioning and Geometric Distortion Correction on the SNS SiPM Anger Camera

Neutron Anger cameras are scintillator-based thermal neutron detectors that utilize pixelated photosensors to read out visible light signals and position neutrons accurately They are versatile detectors that can cover large areas for diffraction instruments and offer high efficiency and sub-millimeter spatial resolution. Photomultiplier Tube (PMT) based cameras are installed on three instruments at Spallation Neutron Source (SNS). The next generation camera uses Silicon Photomultipliers (SiPMs) instead of PMTs, which allows for a more compact design and higher spatial resolution. In this report, the Gaussian least-squares position fitting method is described in detail, as well as the method used to correct for geometric distortions across the face of the camera. Results from neutron camera tests before and after the distortion correction are shown and the spatial resolution is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance and long-term stability of the ICARUS-T600 scintillation light detection system

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently used as a far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible LSND-like sterile neutrino signal at $\Delta m^2 \sim 1 eV^2$ with the Booster Neutrino Beam (BNB). A light detection system, based on 360 large area Photo-Multiplier Tubes (PMTs), has been realized for ICARUS-T600 to detect VUV photons produced after the passage of ionizing particles in LAr. This system is fundamental for the TPC operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the detector is exposed to a huge flux of cosmic rays due to its shallow depths operations, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of neutrino interactions within the BNB spill gate. Long-term behavior of PMT gains and timing resolution, demonstrate the robustness and reliability of the ICARUS scintillation light detection system and provide valuable input for the design and operation of future large-scale liquid argon detectors.

Raselli, Gian Luca [INFN, Perugia] (ORCID:00000002↗

A study of muon neutrino to electron neutrino oscillations in the MINOS experiment

The observation of neutrino oscillations (neutrino changing from one flavor to another) has provided compelling evidence that the neutrinos have non-zero masses and that leptons mix, which is not part of the original Standard Model of particle physics. The theoretical framework that describes neutrino oscillation involves two mass scales (Δm atm 2 and Δm sol 2 ), three mixing angles (θ 12 , θ 23 , and θ 13 ) and one CP violating phase (δ CP ). Both mass scales and two of the mixing angles (θ 12 and θ 23 ) have been measured by many neutrino experiments. The mixing angle θ 13 , which is believed to be very small, remains unknown. The current best limit on θ13 comes from the CHOOZ experiment: θ 13 < 11° at 90% C.L. at the atmospheric mass scale. δ CP is also unknown today. MINOS, the Main Injector Neutrino Oscillation Search, is a long baseline neutrino experiment based at Fermi National Accelerator Laboratory. The experiment uses a muon neutrino beam, which is measured 1 km downstream from its origin in the Near Detector at Fermilab and then 735 km later in the Far Detector at the Soudan mine. By comparing these two measurements, MINOS can obtain parameters in the atmospheric sector of neutrino oscillations. MINOS has published results on the precise measurement of Δm atm 2 and θ 23 through the disappearance of muon neutrinos in the Far Detector and on a search for sterile neutrinos by looking for a deficit in the number of neutral current interactions seen in the Far Detector. MINOS also has the potential to improve the limit on the neutrino mixing angle θ 13 or make the first measurement of its value by searching for an electron neutrino appearance signal in the Far Detector. This is the focus of the study presented in this thesis. We developed a neural network based algorithm to distinguish the electron neutrino signal from background. The most important part of this measurement is the background estimation, which is done through extrapolation. The number of background events is measured at the Near Detector, then extrapolated to the Far Detector. Since different background sources extrapolate differently, some knowledge about the relative contribution from different background sources is necessary. We developed a method that can be used to obtain relative contributions of various background sources from comparison of background rates in the horn-on and horn-off configurations. We also described our effort to improve two aspects of the Monte Carlo simulation which are very important for the v e appearance analysis: one is the hadronization model in the neutrino-nucleon interactions, the other is the modeling of PMT crosstalk. We performed a blind analysis and examined several sidebands before looking at the signal region. After we opened the box, we observed a 1.4 σ excess of v e -like events in the Far Detector compared with the number of predicted background events. The excess is well within the statistical fluctuation of the background events. If we interpret the excess as a v e signal from v μ → v e oscillation, the best fit sin 2 2θ 13 value is consistent with the CHOOZ limit. However we want to emphasize that our result is consistent with θ 13 = 0 at 90% C.L..

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Muon g-2 Calorimeter Prototypes

The proposed design is a tungsten-scintillating fiber calorimeter with 35 segments, each read out by a separate PMT. Tungsten, which is significantly denser than lead, produces compact showers. This is necessary, in order to improve shower separation in analysis and to fully contain the showers within a calorimeter that satisfies the strict space constraints of the experiment. A single calorimeter segment (4 x 6 x 15 cm{sup 3}) has been constructed in order establish the feasibility of the new design and study its properties. Initial tests of the detector segment at the Paul Scherrer Institute were conducted with a low energy < 400 MeV/c electron beam. A higher-energy test with electrons up to a few GeV/c was performed at the Test Beam Facility under the experimental number T-967. All data from that test have been analyzed and published, and the tungsten-scintillating fiber calorimeter still appears to be a viable candidate. For this test beam run, a larger calorimeter (15 x 15 x 11 cm{sup 3}) has been constructed and an emphasis will be placed on understanding shower leakage and the ability to separate pileup events with a more granular readout. The experimenters will measure the energy resolution, linearity, and shower size of the calorimeter segment. This will provide important information for finalizing decisions on the angle of the fibers relative to the incoming electrons and the optimal granularity of the readout.

43 PARTICLE ACCELERATORS↗

BdCESA7 , BdCESA8 , and BdPMT utility promoter constructs for targeted expression to secondary cell-wall-forming cells of grasses

Utility vectors with promoters that confer desired spatial and temporal expression patterns are useful tools for studying gene and cellular function and for industrial applications. To target the expression of DNA sequences of interest to cells forming plant secondary cell walls, which generate most of the vegetative biomass, upstream regulatory sequences of the Brachypodium distachyon lignin biosynthetic gene BdPMT and the cellulose synthase genes BdCESA7 and BdCESA8 were isolated and cloned into binary vectors designed for Agrobacterium -mediated transformation of monocots. Expression patterns were assessed using the β-glucuronidase gene GUSPlus and X-glucuronide staining. All three promoters showed strong expression levels in stem tissue at the base of internodes where cell wall deposition is most active, in both vascular bundle xylem vessels and tracheids, and in interfascicular tissues, with expression less pronounced in developmentally older tissues. In leaves, BdCESA7 and BdCESA8 promoter-driven expression was strongest in leaf veins, leaf margins, and trichomes; relatively weaker and patchy expression was observed in the epidermis. BdPMT promoter-driven expression was similar to the BdCESA promoters expression patterns, including strong expression in trichomes. The intensity and extent of GUS staining varied considerably between transgenic lines, suggesting that positional effects influenced promoter activity. Introducing the BdPMT and BdCESA8 Open Reading Frames into BdPMT and BdCESA8 utility promoter binary vectors, respectively, and transforming those constructs into Brachypodium pmt and cesa8 loss-of-function mutants resulted in rescue of the corresponding mutant phenotypes. This work therefore validates the functionality of these utility promoter binary vectors for use in Brachypodium and likely other grass species. Lastly, the identification, in Bdcesa8-1 T-DNA mutant stems, of an 80% reduction in crystalline cellulose levels confirms that the BdCESA8 gene is a secondary-cell-wall-forming cellulose synthase.

59 BASIC BIOLOGICAL SCIENCES↗

The Event Detection System in the NEXT-White Detector

This article describes the event detection system of the NEXT-White detector, a 5 kg high pressure xenon TPC with electroluminescent amplification, located in the Laboratorio Subterráneo de Canfranc (LSC), Spain. The detector is based on a plane of photomultipliers (PMTs) for energy measurements and a silicon photomultiplier (SiPM) tracking plane for offline topological event filtering. The event detection system, based on the SRS-ATCA data acquisition system developed in the framework of the CERN RD51 collaboration, has been designed to detect multiple events based on online PMT signal energy measurements and a coincidence-detection algorithm. Implemented on FPGA, the system has been successfully running and evolving during NEXT-White operation. The event detection system brings some relevant and new functionalities in the field. A distributed double event processor has been implemented to detect simultaneously two different types of events thus allowing simultaneous calibration and physics runs. This special feature provides constant monitoring of the detector conditions, being especially relevant to the lifetime and geometrical map computations which are needed to correct high-energy physics events. Other features, like primary scintillation event rejection, or a double buffer associated with the type of event being searched, help reduce the unnecessary data throughput thus minimizing dead time and improving trigger efficiency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photodetector timing research at Fermilab

We describe here the outlines of research undertaken by Fermilab into timing characteristics of photodetectors. We describe our experimental method and give benchtop results on the timing resolution of micro-channel plate photomultipliers (MCP-PMT) and silicon photomultipliers (SiPM). In addition, we describe results of various configurations of these detectors, along with quartz radiators, in particle test beams at Fermilab. Results for timing of scintillator light using the DRS4 high speed digitizer are also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Outer planet Grand Tour missions photometry/polarimetry experiment critical components study

Work performed during this effort was limited to two primary areas of technical concern: optical design optimization, and sensor selection. An optical system concept was established, and various system components were evaluated through experimental test sequences. Photodetectors were investigated for the applicability in meeting OPGT requirements as constrained by the photometry/polarimetry team directives. The most promising (gallium arsenide PMT) was further experimentally tested to ascertain its behavior with respect to anticipated environmental conditions. Results of testing and summary of the preceding tradeoff study effort are presented.

Pellicori, S. F.↗

Feasibility test for a V-slit star mapper for pioneer spacecraft terminal navigation

A laboratory demonstration of the feasibility of using a V-slit star mapper to meet the sensitivity and accuracy of on-board navigational requirements for future Pioneer Missions to the outer planets was conducted by the Control and Sensors Laboratory of TRW. The breadboard was extremely simple in configuration, consisting of an end-on photomultiplier tube and a V-slit reticle located at the focal plane of the objective lens. In addition, a plano-convex lens was used between the reticle and the PMT in a Fabry-Perot configuration. The analytical effort indicated that the sensor should easily meet the requirements. The Pioneer SRA test set was examined to determine its basic accuracy and modify it where necessary to bring its accuracy into the 1-3 arc second range. The test results show that it is feasible to use this type of star mapper in the 10 arc second accuracy range. The test equipment accuracy (approximately 5 arc Sec) was sufficient to bound the sensor errors at less than 10 arc seconds.

Gates, R. F.↗

Photomultiplier tube development for the 1.06 micrometer wavelength

High speed, electrostatic photomultipliers were developed for use in 400 megabit laser communication systems operating at the 1.06 micron wavelength. A high performance, electrostatic III-V photocathode PMT was shown in communication system tests to perform competitively with solid state and avalanche photodiodes. Signal-induced noise and III-V cathode stability were identified as remaining technical problems while cathode quantum efficiencies of or = 5% at 1.06 micron and 320 picosecond rise and fall time pulse performance were achieved.

Enck, R. S., Jr.↗

A statistical model of the photomultiplier gain process with applications to optical pulse detection

A Markov diffusion model was used to determine an approximate probability density for the random gain. This approximate density preserves the correct second-order statistics and appears to be in reasonably good agreement with experimental data. The receiver operating curve for a pulse counter detector of PMT cathode emission events was analyzed using this density. The error performance of a simple binary direct detection optical communication system was also derived.

Tan, H. H.↗

Double Compton scatter telescope calibration

Calibration techniques for a medium energy gamma ray telescope are described. Gain calibration using Compton edge spectra involves comparisons of pulse height spectra with spectra simulated by a Monte Carlo computer code which includes Compton scattering and pair production, plural scattering and variable energy resolution, and cell size. The telescope considered comprises 56 cells of liquid scintillator in four size groups, with a total liquid volume of 325 l; each cell has its own photomultiplier tube. Energy and angular resolutions and the PMT gain calibration procedure are verified with double scatter data for monoenergetic gamma rays at a known location. Detection probabilities for any cell combination in the two telescope arrays are calculated per steradian as a function of the scattering for a number of different energies with a Van de Graaff accelerator.

Dayton, B.↗

Approximation to the Probability Density at the Output of a Photmultiplier Tube

The probability density of the integrated output of a photomultiplier tube (PMT) is approximated by the Gaussian, Rayleigh, and Gamma probability densities. The accuracy of the approximations depends on the signal energy alpha: the Gamma distribution is accurate for all alpha, the Raleigh distribution is accurate for small alpha (approximate or less than 1 photon) and the Gaussian distribution is accurate for large alpha (approximate or greater than 10 photons).

Stokey, R. J.↗

A stochastic model for photon noise induced by charged particles in multiplier phototubes of the space telescope fine guidance sensors

The Space Telescope (ST) is subjected to charged particle strikes in its space environment. ST's onboard fine guidance sensors utilize multiplier phototubes (PMT) for attitude determination. These tubes, when subjected to charged particle strikes, generate spurious photons in the form of Cerenkov radiation and fluorescence which give rise to unwanted disturbances in the pointing of the telescope. A stochastic model for the number of these spurious photons which strike the photocathode of the multiplier phototube which in turn produce the unwanted photon noise are presented. The model is applicable to both galactic cosmic rays and charged particles trapped in the Earth's radiation belts. The model which was programmed allows for easy adaption to a wide range of particles and different parameters for the phototube of the multiplier. The probability density functions for photons noise caused by protons, alpha particles, and carbon nuclei were using thousands of simulated strikes. These distributions are used as part of an overall ST dynamics simulation. The sensitivity of the density function to changes in the window parameters was also investigated.

Howell, L. W.↗

Characteristics of the MSFC, PDS microdensitometer

The results of several parametric studies carried out on the Marshall Space Flight Center (MSFC) Photometric Data System PDS-10 microdensitometer are summarized for the purposes of documenting the operation and limitations of the system for inhouse research and to provide a bench mark for comparison with other microdensitometers. The results are grouped into four general areas. These are: (1) system overall stability to drift, (2) photometric linearity and noise, (3) reproducibility, and (4) scanning performance. Test data taken in order to evaluate the interdependency of scan speed, noise and position are included. Shown also are results of tests for system stability, reproducibility, stray light and PMT settling time.

Fountain, W. F.↗