Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Numerical studies of the fluid and optical fields associated with complex cavity flows

Numerical solutions for the flowfield about several cavity configurations have been computed using the Reynolds averaged Navier-Stokes equations. Comparisons between numerical and experimental results are made in two dimensions for free shear layers and a rectangular cavity, and in three dimensions for the transonic aero-window problem of the Stratospheric Observatory for Infrared Astronomy (SOFIA). Results show that dominant acoustic frequencies and magnitudes of the self excited resonant cavity flows compare well with the experiment. In addition, solution sensitivity to artificial dissipation and grid resolution levels are determined. Optical path distortion due to the flow field is modelled geometrically and is found to match the experiment. The fluid field was computed using a diagonalized scheme within an overset mesh framework. An existing code, OVERFLOW, was utilized with the additions of characteristic boundary condition and output routines required for reduction of the unsteady data. The newly developed code is directly applicable to a generalized three dimensional structured grid zone. Details are provided in a paper included in Appendix A.

Atwood, Christopher A.↗

Compact Multi-Gas Monitor for Life Support Systems Control in Space: Evaluation Under Realistic Environmental Conditions

Advanced space life support systems require lightweight, low-power, durable sensors for monitoring critical gas components. A luminescence-based optical flow-through cell to monitor carbon dioxide, oxygen, and humidity has been developed and was demonstrated using bench-top instrumentation under environmental conditions relevant to portable life support systems, including initially pure oxygen atmosphere, temperature range from 50 F to 150 F, and humidity from dry to 100% RH and under conditions of water condensation. This paper presents the most recent progress in the development of this sensor technology. Trace gas contaminants in a space suit, originating from hardware and material off-gassing and crew member metabolism, are from many chemical families. The result is a gas mix much more complex than the pure oxygen fed into the space suit, and this complexity may interfere with gas sensor readings. This paper presents an evaluation of optical sensor performance when exposed to the most significant trace gases reported to be found in space suits. A study of the calibration stability of the sensors is also presented. For that purpose, a profile of temperature, pressure, humidity, and gas composition for the duration of an EVA has been defined, and the performance of sensors operated repeatedly under those conditions has been studied. Finally, this paper presents the first compact readout unit for these optical sensors, designed for the volume, power, and weight restrictions of a PLSS.

Alonso, Jesus Delgado↗

Measurement Capabilities of Planar Doppler Velocimetry in Large-Scale Wind Tunnels

Over the past few years, Planar Doppler Velocimetry (PDT) has been shown by several laboratories to offer an attractive means for measuring three-dimensional velocity vectors everywhere in a light sheet placed in a flow. Unlike some other optical means of measuring flow velocities, PDT is particularly attractive for use in large wind tunnels where distances to the sample region may be several meters, because it does not require the spatial resolution and tracking of individual scattering particles or the alignment of crossed beams at large distances. To date, demonstrations of PDT (also called Doppler Global Velocimetry by some authors) have been made either in low speed flows without quantitative comparison to other measurements, or in supersonic flows where the Doppler shift is large and its measurement is relatively insensitive to instrumental errors. Moreover, most reported applications have relied on the use of continuous-wave lasers, which limit the measurement to time-averaged velocity fields. This work summarizes the results of two previous studies of PDT in which the use of pulsed lasers to obtain instantaneous velocity vector fields is evaluated. The objective has been to quantitatively define and demonstrate PDT capabilities for applications in large-scale wind tunnels that are intended primarily for the testing of rotorcraft and subsonic aircraft at speeds typically less than 100 m/s. For such applications, the adequate resolution of low-speed flow fields requires accurate measurements of small Doppler shifts that are obtained at distances of several meters from the sample region and with a field of view that is sufficient to encompass the entire region of interest. The use of pulsed lasers provides the unique capability to obtain not only time-averaged fields, but also their statistical fluctuation amplitudes and the spatial excursions of unsteady flow regions such as wakes, separations, and rotor-tip vortices. To accomplish the objectives of these studies, the PDT measurement process was first modeled and its performance evaluated computationally. The noise sources considered included those related to the optical and electronic properties of Charge-Coupled Device (CCD) arrays and to speckle effects associated with the coherent illumination of aerosols from pulsed lasers. The signal noise estimates were incorporated into the PDT signal analysis process and combined with computed scattering signals using a Mae scattering theory for a distributed range of aerosol particle sizes. The results are used to define the necessary instrument configuration, to show that the expected signal levels from a practical PDT system are sufficiently large to allow its useful application in large facilities, and to show that the expected velocity measurement uncertainties are small compared to the mean velocities of interest for most subsonic, large-scale wind tunnel testing, Experimental studies using several bench-top setups are then described that validate the physics of the PDT model and demonstrate the ability to obtain accurate PDT measurements using procedures that are compatible with large-scale wind tunnel operations. The PDT measurement capabilities found in this study lead to the conclusion that PDT offers significant advantages compared to other means of measuring velocity fields in large-scale wind tunnels, including those operating at low speeds.

McKenzie, Robert L.↗

Multilayer Approach for Characterization of Bacterial Diversity in a Marginal Sea: From Surface to Seabed

Bacteria are the most important microorganisms in the world oceans, accounting for up to 75% of the total biomass. They are responsible for fundamental biogeochemical processes and therefore often used as ecological indicators. In this study, bacteria were quantified by flow cytometry and their diversity assessed by High Throughput Sequencing (HTS) in the southern Adriatic Sea. The most abundant bacterial groups were also quantified by qPCR. The samples were collected from the surface to the seabed over a total of 16 different depths at four stations during the late winter BIOTA (BIO-Tracing Adriatic water masses) cruise conducted in March 2016. The investigated area showed unusual water mass properties and was characterized by a shallow mixed layer, which differed from the usual winter convection conditions, typical of middle-altitude ecosystems and important for the seasonal picoplankton dynamics of this area. Heterotrophic bacteria were separated into HNA (relative High Nucleic Acid content) and LNA (Low Nucleic Acid content) subpopulations with abundances up to 1.8×10(exp 5) and 8.8×10(exp 5) cells/mL, respectively. HNA dominated at offshore stations reaching their maximum at depths below the euphotic zone. The bacterial community was dominated by Alphaproteobacteria, accounting for greater than 40% of the total sequence reads and were mainly represented by the SAR11 clade (90.84%), followed by Marinimicrobia (18% of the total sequence reads), mainly represented by clade SAR406 (8.44%). Distinctive bacterial groups were found in the euphotic layer (Bacteroidetes and Actinobacteria) and aphotic layer samples (Deltaproteobacteria, Marinimicrobia, Chloroflexi, Acidobacteria and Planctomycetes). Results of the qPCR analyses further confirmed HTS results with highest abundances obtained for Alphaproteobacteria, followed by Gammaproteobacteria and Bacteroidetes. The adopted multiple approach, combining different molecular tools, critically supported by optics and flow cytometry, reveal changes in the bacterial assemblages during the unusual thermohaline conditions observed in 2016 in the southern Adriatic Sea.

Southern Adriatic Sea↗

Path-Integrated Stereo X-Ray Digital Image Correlation: Resolving the Violation of Conservation of Intensity

In this study, x-ray imaging addresses many challenges with visible light imaging in extreme environments, where optical diagnostics such as digital image correlation (DIC) and particle image velocimetry (PIV) suffer biases from index of refraction changes and/or cannot penetrate visibly occluded objects. However, conservation of intensity—the fundamental principle of optical image correlation algorithms—may be violated if ancillary components in the X-ray path besides the surface or fluid of interest move during the test. The test series treated in this work sought to characterize the safe use of fiber-epoxy composites in aerospace and aviation industries during fire accident scenarios. Stereo X-ray DIC was employed to measure test unit deformation in an extreme thermal environment involving a visibly occluded test unit, incident surface heating to temperatures above 600°C, and flames and soot from combusting epoxy decomposition gasses. The objective of the current work is to evaluate two solutions to resolve the violation of conservation of intensity that resulted from both the test unit and the thermal chamber deforming during the test. The first solution recovered conservation of intensity by pre-processing the path-integrated X-ray images to isolate the DIC pattern of the test unit from the thermal chamber components. These images were then correlated with standard, optical DIC software. The second solution, called Path-Integrated Digital Image Correlation (PI-DIC), modified the fundamental matching criterion of DIC to account for multiple, independently-moving components contributing to the final image intensity. The PI-DIC algorithm was extended from a 2D framework to a stereo framework and implemented in a custom DIC software. Both solutions accurately measured the cylindrical shape of the undeformed test unit, recovering radii values of R = 76.20±0.12 mm compared to the theoretical radius of R theor = 76.20 mm. During the test, the test unit bulged asymmetrically as decomposition gasses pressurized the interior and eventually burned in a localized jet. Both solutions measured the heterogeneous radius of this bulge, which reached a maximum of approximately R = 91 mm, with a discrepancy of 2–3% between the two solutions. Two solutions that resolve the violation of conservation of intensity for path-integrated X-ray images were developed. Both were successfully employed in a stereo X-ray DIC configuration to measure deformation of an aluminum-skinned, fiber-epoxy composite test unit in a fire accident scenario.

47 OTHER INSTRUMENTATION↗

Charge Separation in Monolayer WSe 2 by Strain Engineering: Implications for Strain-Induced Diode Action

Strain-engineering band structure in transition-metal dichalcogenides (TMDC) is a promising avenue toward capabilities in optoelectronics. For example, controlling the flow of optically generated quasiparticles can be achieved by a localized strain field which reduces the bandgap and generates an energy-band gradient that funnels neutral excitons to the strain apex. It would be even more advantageous to mimic a diode’s internal field, where both conduction and valence bands bend in the same direction, to separate electrons and holes. This can be achieved if the strain in the TMDC layer lowers both the conduction band minimum as well as the valence band maximum during strain-induced band narrowing. Here, we have used density functional theory (DFT) calculations of monolayer WSe 2 electronic structure under biaxial strain to show that WSe 2 has this property. In this work, to test the band bending experimentally, we combined localized strain with electrostatic doping to follow photoluminescence from excitons and positive or negative trions. In unstrained WSe 2 , both positive and negative trion emissions dominate over excitons away from charge neutrality. In contrast, for strained areas, negative trions accumulate, while positive trion emission is near zero away from charge neutrality, indicating a lack of holes. Hence, strain bends both conduction and valence bands down, similarly to the band bending in a PN-diode depletion region, providing an opportunity to separate electrons and holes via localized strain.

2D materials↗

A combined numerical and experimental study to elucidate primary breakup dynamics in liquid metal droplet-on-demand printing

Droplet-on-demand liquid metal jetting is emerging as a powerful technology for the additive manufacturing of metallic parts. The success of this method hinges on overcoming several technological challenges. Additionally, the principal one among these challenges is the controlled repeatable ejection of single uniform droplets. Due to the high density and surface tension of liquid metals, the droplet ejection process occurs near the minimal extremes of the printability phase diagram, defined by acceptable ranges for the Weber (We) and Ohnesorge (Oh) numbers. In this work, we experimentally demonstrate the satellite-free ejection of pneumatically actuated molten tin droplets in this extreme corner of printability and use a combination of high-speed video analysis and volume-of-fluid modeling to elucidate the droplet dynamics. While the simulations at low Oh and We can correctly describe several aspects of the breakup process, such as an increasing tail and pinch-point near the nozzle, no single parameter set can completely capture the droplet shape at breakup. Instead, the experimental droplet dynamics appear to include features from both high and low Oh breakup. This disagreement is ascribed to the incomplete description of the droplet ejection process including wetting and exit effects near the nozzle opening and surface effects such as transient cooling and oxide formation.

36 MATERIALS SCIENCE↗

Molecular outflows driven by low-mass protostars. I. Correcting for underestimates when measuring outflow masses and dynamical properties

We present a survey of 28 molecular outflows driven by low-mass protostars, all of which are sufficiently isolated spatially and/or kinematically to fully separate into individual outflows. Using a combination of new and archival data from several single-dish telescopes, 17 outflows are mapped in {sup 12}CO (2-1) and 17 are mapped in {sup 12}CO (3-2), with 6 mapped in both transitions. For each outflow, we calculate and tabulate the mass (M {sub flow}), momentum (P {sub flow}), kinetic energy (E {sub flow}), mechanical luminosity (L {sub flow}), and force (F {sub flow}) assuming optically thin emission in LTE at an excitation temperature, T {sub ex}, of 50 K. We show that all of the calculated properties are underestimated when calculated under these assumptions. Taken together, the effects of opacity, outflow emission at low velocities confused with ambient cloud emission, and emission below the sensitivities of the observations increase outflow masses and dynamical properties by an order of magnitude, on average, and factors of 50-90 in the most extreme cases. Different (and non-uniform) excitation temperatures, inclination effects, and dissociation of molecular gas will all work to further increase outflow properties. Molecular outflows are thus almost certainly more massive and energetic than commonly reported. Additionally, outflow properties are lower, on average, by almost an order of magnitude when calculated from the {sup 12}CO (3-2) maps compared to the {sup 12}CO (2-1) maps, even after accounting for different opacities, map sensitivities, and possible excitation temperature variations. It has recently been argued in the literature that the {sup 12}CO (3-2) line is subthermally excited in outflows, and our results support this finding.

79 ASTRONOMY AND ASTROPHYSICS↗

THERMAL STABILITY OF MAGNETIZED, OPTICALLY THIN, RADIATIVE COOLING-DOMINATED ACCRETION DISKS

We investigate the thermal stability of optically thin, two-temperature, radiative cooling-dominated accretion disks. Our linear analysis shows that the disk is thermally unstable without magnetic fields, which agrees with previous stability analysis on the Shapiro-Lightman-Eardley disk. By taking into account the effects of magnetic fields, however, we find that the disk can be, or partly be, thermally stable. Our results may be helpful to understand the outflows in optically thin flows. Moreover, such radiative cooling-dominated disks may provide a new explanation of the different behaviors between black hole and neutron star X-ray binaries on the radio/X-ray correlation.

79 ASTRONOMY AND ASTROPHYSICS↗

Time calibration and synchronization of the scintillation light detection system in ICARUS-T600

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently taking data in the Short Baseline Neutrino (SBN) program at Fermilab (U.S.A.) to search for a possible LSND-like sterile neutrino signal at Δm 2 ≈ 1 eV 2 with the Booster Neutrino Beam (BNB). A light detection system, based on 360 large area Photo-Multiplier Tubes (PMTs), has been realized for ICARUS-T600 to detect VUV photons produced by the passage of ionizing particles in LAr. This system is fundamental for the TPC operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the detector is exposed to a huge flux of cosmic rays due to its shallow depths installation, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of genuine neutrino interactions. The correct time reconstruction of events requires the precise knowledge of the delay of each PMT channel and a good synchronization of recording electronics, this last based on fast sampling digitizers. To achieve a time resolution better than 1 ns, we perform three consecutive timing corrections deployed at different stages of the optical data flow. Results demonstrate the capability of the ICARUS-T600 light detection system to allow a precise reconstruction of the temporal evolution of each event occurring in the detector and the association of neutrino events with the bunched structure of BNB.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SUPER-CRITICAL GROWTH OF MASSIVE BLACK HOLES FROM STELLAR-MASS SEEDS

We consider super-critical accretion with angular momentum onto stellar-mass black holes as a possible mechanism for growing billion-solar-mass black holes from light seeds at early times. We use the radiatively inefficient ''slim disk'' solution—advective, optically thick flows that generalize the standard geometrically thin disk model—to show how mildly super-Eddington intermittent accretion may significantly ease the problem of assembling the first massive black holes when the universe was less than 0.8 Gyr old. Because of the low radiative efficiencies of slim disks around non-rotating as well as rapidly rotating black holes, the mass e-folding timescale in this regime is nearly independent of the spin parameter. The conditions that may lead to super-critical growth in the early universe are briefly discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of liquid-phase thermometry in impinging jet sprays using synchrotron x-ray scattering

Liquid thermometry during primary and secondary breakup of liquid sprays is challenging due to the presence of highly dynamic, optically complex flow features. This work evaluates the use of x-ray scattering from a focused, monochromatic beam of the Advanced Photon Source at Argonne National Laboratory for the measurement of liquid temperatures within the mixing zone of an impinging jet spray. The measured scattering profiles are converted to temperature through a previously developed two-component partial least squares (PLS) regression model. Transmitive mixing during jet merging is inferred through spatial mapping of temperatures within the impingement region. In this work, the technique exhibits uncertainties of ±2K in temperature and 2% in capturing the correct scattering profile, showing its potential utility for probing liquid temperature distributions in multiphase flows.

42 ENGINEERING↗

Durable, Ultra-Thin Diaphragms for Liquid Alkaline Water Electrolysis

W. L. Gore & Associates assembled a world class team (De Nora Tech, LLC; New York University; and thyssenkrupp nucera) to develop durable, ultra-low resistance diaphragms that dramatically improve system efficiency, dynamic response, and operational flexibility. To enable the use of ultra-thin diaphragms, an optimized electrode package was chosen as part of an electrode down select study. Ultra-thin diaphragms based on microporous polymer scaffolds imbibed with zirconia nanoparticles were developed and tested. Performance and durability on par with incumbent materials was demonstrated. A transparent electrolyzer to directly observe in-situ diaphragm-bubble interactions was designed and built, and simultaneous optical and electrochemical performance tests were performed. A Pressurized Alkaline Water Electrolysis (PAWE) single cell test station was designed to support advanced R&D in high-pressure electrolysis, particularly for evaluating novel electrode and separator configurations under elevated temperature and pressure operating conditions. Due to early project termination, the original scope could not be fully achieved.

08 HYDROGEN↗

Instrumentation for airbreathing propulsion; Proceedings of the Symposium, U.S. Naval Postgraduate School, Monterey, Calif., September 19-21, 1972

New developments and refinements in measuring techniques used for both ground testing and in-flight control, diagnosis, and monitoring of airbreathing combustors are analyzed in a number of papers. Some of the techniques studied include the application of laser velocimeters for flow measurements; on-the-shaft data systems for rotating engine components; total pressure averaging in pulsating flows; fiber optic and laser digital pressure transducers; holography of nozzles, jets, and spraying systems; application of the Raman effect fo flowfield diagnostics; holography of JP-4 droplets and combusting boron particles; the use of a laser-powered optical proximity probe in advanced turbofan engine development; pyrometry for measurement of surface temperature distribution on a rotating turbine blade; an ultrasonic turbine inlet gas temperature sensor; automatic detection and suppression of inlet buzz; and electrostatic probes for sensing incipient engine failure. Individual items are announced in this issue.

Fuhs, A. E.↗

Laser Doppler Velocimeter System

Seeded flows measured optically. Laser Doppler velocimeter integrated with wind-tunnel pressure vessel with mounting system minimizing effects of vibrations and of pressure and thermal strains.

Seegmiller, H. Lee↗

Water intrusion in thin-skinned composite honeycomb sandwich structures

Thin-skinned composite honeycomb sandwich structures from the trailing edge of the U.S. Army's Apache and Chinook helicopters have been tested to ascertain their susceptibility to water intrusion as well as such intrusions' effects on impact damage and cyclic loading. Minimum-impact and fatigue conditions were determined which would create microcracks sufficiently large to allow the passage of water through the skins; damage sufficient for this to occur was for some skins undetectable under a 40X-magnification optical microscope. Flow rate was a function of moisture content, damage, applied strain, and pressure differences.

Jackson, Wade C.↗

Three-component laser Doppler velocimeter measurements in a juncture flow

A single-axis, five-beam, three-component laser velocimeter (LV) system was used in a major experiment. Satisfactory results were obtained with the LV system in the juncture flow. Limited optical access to the tunnel proved to be a problem for the three component LV system in determining the third component.

Kubendran, L. R.↗