Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Occupancy prediction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

An over-approximation of entropy for elemental multiconfigurational ground state electronic structures

The ability to predict the chemical and physical properties of a material is directly related to the structure and interactions of its electrons. For materials comprised of f-block elements (the lanthanides and actinides found in the last two rows of the periodic table), the complexity of electronic structure has presented great difficulty in understanding, modeling, and predicting material properties. The complexity of multiconfigurational ground state electronic structures is illustrated herein by the combinatorics of electron permutations within individual and cumulative occupancy configurations. A non-integer orbital occupancy representation of multiconfigurational ground states is described for superposition mixing between multiple near-energy degenerate occupancy configurations and generalized in such a way that established ground states are returned by approximation for elements with less-complex electronic structures. By considering the occupancy configurations as statistical mechanics macrostates, and the permutations of electrons as statistical mechanics microstates within those macrostates, an over-approximation of entropy for multiconfigurational elemental ground state electronic structures has been calculated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

HEMS: Home Energy Management System [SWR-15-12] - Stochastic Optimal Scheduling of Residential Appliances with Renewable Energy Sources

The HEMS algorithm schedules residential appliance operation to minimize the weighted sum of occupant discomfort, total energy cost, peak electricity consumption and carbon footprint, weighted according to occupant preferences. A centralized mixed integer linear programming (MILP) based optimization approach is taken, with the HEMS managing all appliances directly, following a Model Predictive Control (MPC) methodology which determines the optimal schedule over the user-specified scheduling horizon and repeats the optimization at configurable time intervals. The HEMS is developed on the General Algebraic Modeling System (GAMS) using the MILP solver. This system is able to effectively deal with the stochasticity in the distributed system by utilizing Monte Carlo simulation where uncertainties in future electricity price, outdoor temperature, water usage, solar and wind generation can be accounted for. The HEMS controls the operation of the heating, ventilation and air conditioning (HVAC) system, water heater, refrigerator, residential batteries, electric vehicles, standalone micro combined heat and power (CHP) generator, dishwasher, washer/dryer, pool pumps, and lighting.

Pratt, Annabelle↗

Quantum-mechanical treatment of an electron undergoing synchrotron radiation.

The problem of an electron moving perpendicular to an intense magnetic field is approached from the framework of quantum mechanics. A numerical solution to the related rate equations describing the probabilities of occupation of the electron's energy states is put forth along with the expected errors involved. The quantum-mechanical approach is found to predict a significant amount of energy broadening with time for an initially monoenergetic electron beam entering a region of an intense magnetic field as long as the product of initial energy and magnetic field is of order 50 MG BeV or larger.

White, D.↗

NASA/FAA general aviation crash dynamics program - A status report

The objective of the Langley Research Center general aviation crash dynamics program is to develop technology for improved crash safety and occupant survivability in general aviation aircraft. The program involves three basic areas of research: controlled full-scale crash testing, nonlinear structural analyses to predict large deflection elasto-plastic response, and load attenuating concepts for use in improved seat and subfloor structure. Both analytical and experimental methods are used to develop expertise in these areas. Analyses include simplified procedures for estimating energy dissipating capabilities and complex computerized procedures for predicting airframe response. These analyses are being developed to provide designers with methods for predicting accelerations, loads, and displacements of collapsing structure. Tests on typical full-scale aircraft and on full- and sub-scale structural components are being performed to verify the analyses and to demonstrate load attenuating concepts.

Thomson, R. G.↗

Modeling of HVAC operational faults in building performance simulation

Operational faults are common in the heating, ventilating, and air conditioning (HVAC) systems of existing buildings, leading to a decrease in energy efficiency and occupant comfort. Various fault detection and diagnostic methods have been developed to identify and analyze HVAC operational faults at the component or subsystem level. However, current methods lack a holistic approach to predicting the overall impacts of faults at the building level—an approach that adequately addresses the coupling between various operational components, the synchronized effect between simultaneous faults, and the dynamic nature of fault severity. This study introduces the novel development of a fault-modeling feature in EnergyPlus which fills in the knowledge gap left by previous studies. This paper presents the design and implementation of the new feature in EnergyPlus and discusses in detail the fault-modeling challenges faced. The new fault-modeling feature enables EnergyPlus to quantify the impacts of faults on building energy use and occupant comfort, thus supporting the decision making of timely fault corrections. Including actual building operational faults in energy models also improves the accuracy of the baseline model, which is critical in the measurement and verification of retrofit or commissioning projects. As an example, EnergyPlus version 8.6 was used to investigate the impacts of a number of typical operational faults in an office building across several U.S. climate zones. Finally, the results demonstrate that the faults have significant impacts on building energy performance as well as on occupant thermal comfort. Finally, the paper introduces future development plans for EnergyPlus fault-modeling capability.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

In vivo doses of butadiene epoxides as estimated from in vitro enzyme kinetics by using cob(I)alamin and measured hemoglobin adducts: An inter-species extrapolation approach

1,3-Butadiene (BD) is a rodent and human carcinogen. In the cancer tests, mice have been much more susceptible than rats with regard to BD-induced carcinogenicity. The species-differences are dependent on metabolic formation/disappearance of the genotoxic BD epoxy-metabolites that lead to variations in the respective in vivo doses, i.e. “area under the concentration-time curve” (AUC). Differences in AUC of the most gentoxic BD epoxy-metabolite, diepoxybutane (DEB), are considered important with regard to cancer susceptibility. The present work describes: the application of cob(I)alamin for accurate measurements of in vitro enzyme kinetic parameters associated with BD epoxy-metabolites in human, mouse and rat; the use of published data on hemoglobin (Hb) adduct levels of BD epoxides from BD exposure studies on the three species to calculate the corresponding AUCs in blood; and a parallelogram approach for extrapolation of AUC of DEB based on the in vitro metabolism studies and adduct data from in vivo measurements. The predicted value of AUC of DEB for humans from the parallelogram approach was 0.078 nM · h for 1 ppm · h of BD exposure compared to 0.023 nM · h/ppm · h as calculated from Hb adduct levels observed in occupational exposure. The corresponding values in nM · h/ppm · h were for mice 41 vs. 38 and for rats 1.26 vs. 1.37 from the parallelogram approach vs. experimental exposures, respectively, showing a good agreement. This quantitative inter-species extrapolation approach will be further explored for the clarification of metabolic rates/pharmacokinetics and the AUC of other genotoxic electrophilic compounds/metabolites, and has a potential to reduce and refine animal experiments. - Highlights: • In vitro metabolism to in vivo dose extrapolation of butadiene metabolites was proposed. • A parallelogram approach was introduced to estimate dose (AUC) in humans and rodents. • AUC of diepoxybutane predicted in humans was 0.078 nM h/ppm h butadiene exposure. • The presented approach has a potential to reduce, refine and replace animal experiments.

60 APPLIED LIFE SCIENCES↗

Thermalized axion inflation

We analyze the dynamics of inflationary models with a coupling of the inflaton φ to gauge fields of the form φ F F-tilde / f , as in the case of axions. It is known that this leads to an instability, with exponential amplification of gauge fields, controlled by the parameter ξ= φ-dot /(2 fH ), which can strongly affect the generation of cosmological perturbations and even the background. We show that scattering rates involving gauge fields can become larger than the expansion rate H , due to the very large occupation numbers, and create a thermal bath of particles of temperature T during inflation. In the thermal regime, energy is transferred to smaller scales, radically modifying the predictions of this scenario. We thus argue that previous constraints on ξ are alleviated. If the gauge fields have Standard Model interactions, which naturally provides reheating, they thermalize already at ξ∼>2.9, before perturbativity constraints and also before backreaction takes place. In absence of SM interactions (i.e. for a dark photon), we find that gauge fields and inflaton perturbations thermalize if ξ∼>3.4; however, observations require ξ∼>6, which is above the perturbativity and backreaction bounds and so a dedicated study is required. After thermalization, though, the system should evolve non-trivially due to the competition between the instability and the gauge field thermal mass. If the thermal mass and the instabilities equilibrate, we expect an equilibrium temperature of T {sub eq} ≅ ξ H / g-bar where g-bar is the effective gauge coupling. Finally, we estimate the spectrum of perturbations if φ is thermal and find that the tensor to scalar ratio is suppressed by H /(2 T ), if tensors do not thermalize.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Metering Best Practices Applied in the National Renewable Energy Laboratory's Research Support Facility: A Primer to the 2011 Measured and Modeled Energy Consumption Datasets

Modern buildings are complex energy systems that must be controlled for energy efficiency. The Research Support Facility (RSF) at the National Renewable Energy Laboratory (NREL) has hundreds of controllers -- computers that communicate with the building's various control systems -- to control the building based on tens of thousands of variables and sensor points. These control strategies were designed for the RSF's systems to efficiently support research activities. Many events that affect energy use cannot be reliably predicted, but certain decisions (such as control strategies) must be made ahead of time. NREL researchers modeled the RSF systems to predict how they might perform. They then monitor these systems to understand how they are actually performing and reacting to the dynamic conditions of weather, occupancy, and maintenance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NREL RSF Weather Data 2011

Modern buildings are complex energy systems that must be controlled for energy efficiency. The Research Support Facility (RSF) at the National Renewable Energy Laboratory (NREL) has hundreds of controllers -- computers that communicate with the building's various control systems -- to control the building based on tens of thousands of variables and sensor points. These control strategies were designed for the RSF's systems to efficiently support research activities. Many events that affect energy use cannot be reliably predicted, but certain decisions (such as control strategies) must be made ahead of time. NREL researchers modeled the RSF systems to predict how they might perform. They then monitor these systems to understand how they are actually performing and reacting to the dynamic conditions of weather, occupancy, and maintenance. This submission includes the Weather data form the RSF systems energy model. The weather data was used to contextualize and compare energy use data like heating and cooling. The weather data was also used by the RSF Energy Model to model the energy use of the RSF. Energy Model data and Measured Energy data related to the RSF Systems Model can be found in the "Related Datasets" section of this submission.

2011↗

NREL RSF Measured Data 2011

Modern buildings are complex energy systems that must be controlled for energy efficiency. The Research Support Facility (RSF) at the National Renewable Energy Laboratory (NREL) has hundreds of controllers -- computers that communicate with the building's various control systems -- to control the building based on tens of thousands of variables and sensor points. These control strategies were designed for the RSF's systems to efficiently support research activities. Many events that affect energy use cannot be reliably predicted, but certain decisions (such as control strategies) must be made ahead of time. NREL researchers modeled the RSF systems to predict how they might perform. They then monitor these systems to understand how they are actually performing and reacting to the dynamic conditions of weather, occupancy, and maintenance. This submission includes the Measured Energy Data from the RSF Systems Model. The data includes a csv with measured data from NREL's Research and Support Facility (RSF) for 2011. The dataset contains hourly data for: Total Cooling (kW)- Total Heating (kW)- Total Mechanical (kW)- Total Lighting (kW)- Total Plug Loads (kW)- Total Data Center (kW)- Total Building (kW)- PV (kW)- Building Net (kW). Energy Model data and Weather data related to the RSF Systems Model can be found in the "Related Datasets" section of this submission.

2011↗

NREL RSF Energy Model 2011

Modern buildings are complex energy systems that must be controlled for energy efficiency. The Research Support Facility (RSF) at the National Renewable Energy Laboratory (NREL) has hundreds of controllers -- computers that communicate with the building's various control systems -- to control the building based on tens of thousands of variables and sensor points. These control strategies were designed for the RSF's systems to efficiently support research activities. Many events that affect energy use cannot be reliably predicted, but certain decisions (such as control strategies) must be made ahead of time. NREL researchers modeled the RSF systems to predict how they might perform. They then monitor these systems to understand how they are actually performing and reacting to the dynamic conditions of weather, occupancy, and maintenance. This submission includes the Energy Model from the RSF Systems Model. Comparing actual performance (metered) with expected performance (modeled) is key to understand corrective actions to ensure performance as originally intended. The Energy Model in this submission was made to model energy usage in the RSF and was compared to actual metered data to verify the model. Measured data and Weather data related to the RSF Systems Model can be found in the "Related Datasets" section of this submission.

2011↗

Metering Best Practices Applied in the National Renewable Energy Laboratory's Research Support Facility: A Primer to the 2011 Measured and Modeled Energy Consumption Datasets

Modern buildings are complex energy systems that must be controlled for energy efficiency. The Research Support Facility (RSF) at the National Renewable Energy Laboratory (NREL) has hundreds of controllers -- computers that communicate with the building's various control systems -- to control the building based on tens of thousands of variables and sensor points. These control strategies were designed for the RSF's systems to efficiently support research activities. Many events that affect energy use cannot be reliably predicted, but certain decisions (such as control strategies) must be made ahead of time. NREL researchers modeled the RSF systems to predict how they might perform. They then monitor these systems to understand how they are actually performing and reacting to the dynamic conditions of weather, occupancy, and maintenance.

47 OTHER INSTRUMENTATION↗

Metering Best Practices Applied in the National Renewable Energy Laboratory's Research Support Facility: A Primer to the 2011 Measured and Modeled Energy Consumption Datasets

Modern buildings are complex energy systems that must be controlled for energy efficiency. The Research Support Facility (RSF) at the National Renewable Energy Laboratory (NREL) has hundreds of controllers -- computers that communicate with the building's various control systems -- to control the building based on tens of thousands of variables and sensor points. These control strategies were designed for the RSF's systems to efficiently support research activities. Many events that affect energy use cannot be reliably predicted, but certain decisions (such as control strategies) must be made ahead of time. NREL researchers modeled the RSF systems to predict how they might perform. They then monitor these systems to understand how they are actually performing and reacting to the dynamic conditions of weather, occupancy, and maintenance.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

General aviation crash safety program at Langley Research Center

The purpose of the crash safety program is to support development of the technology to define and demonstrate new structural concepts for improved crash safety and occupant survivability in general aviation aircraft. The program involves three basic areas of research: full-scale crash simulation testing, nonlinear structural analyses necessary to predict failure modes and collapse mechanisms of the vehicle, and evaluation of energy absorption concepts for specific component design. Both analytical and experimental methods are being used to develop expertise in these areas. Analyses include both simplified procedures for estimating energy absorption capabilities and more complex computer programs for analysis of general airframe response. Full-scale tests of typical structures as well as tests on structural components are being used to verify the analyses and to demonstrate improved design concepts.

Thomson, R. G.↗

Computational strategy for quantifying human pesticide exposure based upon a saliva measurement

The National Research Council of the National Academies report, Toxicity Testing in the 21st Century: A Vision and Strategy, highlighted the importance of quantitative exposure data for evaluating human toxicity risk and noted that biomonitoring is a critical tool for quantitatively evaluating exposure from both environmental and occupational settings. Direct measurement of chemical exposures using personal monitoring provides the most accurate estimation of a subject’s true exposure, and non-invasive methods have also been advocated for quantifying the pharmacokinetics and bioavailability of drugs and xenobiotics. In this regard, there is a need to identify chemicals that are readily cleared in saliva at concentrations that can be quantified to support the implementation of this approach.. The current manuscript describes the use of computational modeling approaches that are closely coupled to in vivo and in vitro experiments to predict salivary uptake and clearance of xenobiotics. The primary mechanism by which xenobiotics leave the blood and enter saliva is thought to involve paracellular transport, passive transcellular diffusion, or trancellular active transport with the majority of drugs and xenobiotics cleared from plasma into saliva by passive diffusion. The transcellular or paracellular diffusion of unbound chemicals in plasma to saliva has been computational modeled using a combination of compartmental and physiologically based approaches. Of key importance for determining the plasma:saliva partitioning was the utilization of a modified Schmitt algorithm that calculates partitioning based upon the tissue composition, pH, chemical pKa and plasma protein-binding. Sensitivity analysis of key model parameters specifically identified that both protein-binding and pKa (for weak acids and bases) had the most significant impact on the determination of partitioning and that there were clear species dependent differences based upon physiological variance between rats and humans. Ongoing efforts are focused on extending this modeling strategy to an in vitro salivary acinar cell based system that will be utilized to experimentally determine and computationally predict salivary gland uptake and clearance for a broad range of xenobiotics. Hence, it is envisioned that a combination of salivary biomonitoring and computational modeling will enable the non-invasive measurement of both environmental and occupational exposure in human populations using saliva.

compuational strategy↗

Co-simulation for performance prediction of integrated building and HVAC systems - An analysis of solution characteristics using a two-body system

Integrated performance simulation of buildings and heating, ventilation and airconditioning (HVAC) systems can help reducing energy consumption and increasing occupant comfort. However, no single building performance simulation (BPS) tool offers suffcient capabilities and flexibilities to analyze integrated building systems and to enable rapid prototyping of innovative building and system technologies. One way to alleviate this problem is to use co-simulation to integrate different BPS tools. Co-simulation approach represents a particular case of simulation scenario where at least two simulators solve coupled differential-algebraic systems of equations and exchange data that couples these equations during the time integration. This article analyzes how co-simulation influences consistency, stability and accuracy of the numerical approximation to the solution. Consistency and zero-stability are studied for a general class of the problem, while a detailed consistency and absolute stability analysis is given for a simple two-body problem. Since the accuracy of the numerical approximation to the solution is reduced in co-simulation, the article concludes by discussing ways for how to improve accuracy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DARK MATTER SEARCHES IN THE GAMMA-RAY EXTRAGALACTIC BACKGROUND VIA CROSS-CORRELATIONS WITH GALAXY CATALOGS

We compare the measured angular cross-correlation between the Fermi-Large Area Telescope γ-ray sky and catalogs of extragalactic objects with the expected signal induced by weakly interacting massive particle (WIMP) dark matter (DM). We include a detailed description of the contribution of astrophysical γ-ray emitters such as blazars, misaligned active galactic nucleus (AGN), and star-forming galaxies, and perform a global fit to the measured cross-correlation. Five catalogs are considered: Sloan Digital Sky Survey (SDSS)-DR6 quasars, Two Micron All Sky Survey galaxies, NRAO VLA Sky Survey radio galaxies, SDSS-DR8 Luminous Red Galaxies, and the SDSS-DR8 main galaxy sample. To model the cross-correlation signal, we use the halo occupation distribution formalism to estimate the number of galaxies of a given catalog in DM halos and their spatial correlation properties. We discuss uncertainties in the predicted cross-correlation signal arising from the DM clustering and WIMP microscopic properties, which set the DM γ-ray emission. The use of different catalogs probing objects at different redshifts significantly reduces, though not completely, the degeneracy among the different γ-ray components. We find that the presence of a significant WIMP DM signal is allowed by the data but not significantly preferred by the fit, although this is mainly due to a degeneracy with the misaligned AGN component. With modest substructure boost, the sensitivity of this method excludes thermal annihilation cross sections at 95% level for WIMP masses up to few tens of GeV. Constraining the low-redshift properties of astrophysical populations with future data will further improve the sensitivity to DM.

79 ASTRONOMY AND ASTROPHYSICS↗

Limitations to the ‘basic’ HOD model and beyond

ABSTRACT We use the IllustrisTNG cosmological, hydrodynamical simulations to test fundamental assumptions of the mass-based halo occupation distribution (HOD) approach to modelling the galaxy–halo connection. By comparing the clustering of galaxies measured in the 300 Mpc TNG box (TNG300) with that predicted by the standard (basic) HOD model, we find that, on average, the ‘basic’ HOD model underpredicts the real-space correlation function in the TNG300 box by ∼15 per cent on scales of $1 \,\,\lt\,\, r \,\,\lt\,\, 20 \ {\rm Mpc}\, h^{-1}$, which is well beyond the target precision demanded of next-generation galaxy redshift surveys. We perform several tests to establish the robustness of our findings to systematic effects, including the effect of finite box size and the choice of halo finder. In our exploration of ‘secondary’ parameters with which to augment the ‘basic’ HOD, we find that the local environment of the halo, the velocity dispersion anisotropy, β, and the product of the half-mass radius and the velocity dispersion, σ2Rhalfmass, are the three most effective measures of assembly bias that help reconcile the ‘basic’ HOD-predicted clustering with that in TNG300. In addition, we test other halo properties such as halo spin, formation epoch, and halo concentration. We also find that at fixed halo mass, galaxies in one type of environment cluster differently from galaxies in another. We demonstrate that a more complete model of the galaxy–halo connection can be constructed if we combine both mass and local environment information about the halo.

42 ENGINEERING↗