Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Occupancy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Factors linked to participant attrition in a longitudinal occupational health surveillance program

For occupational medical screening programs focused on long-term health surveillance, participant attrition is a significant barrier to success. Here we investigate demographic, medical history, and clinical data from National Supplemental Screening Program (NSSP) examinees for association with likelihood of return for a second exam (rescreening). A total of 15,733 individuals completed at least one NSSP exam before December 31, 2016; of those, 4832 also completed a second exam on or before December 31, 2019. Stepwise logistic regression models were used to identify variables associated with whether a participant was rescreened in the NSSP. Individuals were less likely to return for rescreening if they had a history of any cancer; cardiovascular problems; diabetes or kidney disease; or if they used insulin. Age at time of first exam and job site category significantly influenced likelihood of return. Workers categorized as “guests” were more likely to return. Participants were less likely to return if they had an abnormal urinalysis, abnormal pulmonary function, pneumoconiosis, aortic atherosclerosis, or hearing loss at their initial exam. Participants who received a chest X-ray at their initial screening were more likely to return. The presence of health problems is strongly linked to screening program attrition. Participants who are older at the time of their initial screening exam are less likely to return. The discovery of several strong demographic, medical, and job associations reveals the importance for medical screening programs to understand and address factors that influence participant retention and, consequently, the effectiveness of long-term health surveillance activities.

60 APPLIED LIFE SCIENCES↗

Filters from taxis air conditioning system: A tool to characterize driver's occupational exposure to bioburden?

Highlights: • Filters from air conditioning system are a suitable method to characterize bioburden in vehicles. • Fungi and bacteria occur widely in taxis and personal vehicles. • The genera Aspergillus, Cladosporium and Penicillium were often detected. • Filters should be more frequently replaced to avoid bioburden proliferation and reaerosolization. • Culture based and molecular methods used in parallel enabled an improved risk characterization. Bioburden proliferation in filters from air conditioning systems of taxis represents a possible source of occupational exposure. The aim of this study was to determine the occurrence of fungi and bacteria in filters from the air conditioning system of taxis used for patient transportation and to assess the exposure of drivers to bioburden. Filters from the air conditioning systems of 19 taxis and 28 personal vehicles (used as controls) operating in three Portuguese cities including the capital Lisbon, were collected during the winter season. The occurrence and significance of bioburden detected in the different vehicles are reported and discussed in terms of colony-forming units (CFU) per 1 m{sup 2} of filter area and by the identification of the most frequently detected fungal isolates based on morphology. Azole-resistant mycobiota, fungal biomass, and molecular detection of Aspergillus species/strains were also determined. Bacterial growth was more prevalent in taxis (63.2%) than in personal vehicles (26.3%), whereas fungal growth was more prevalent in personal vehicles (53.6%) than in taxis (21.1–31.6%). Seven different azole-resistant species were identified in this study in 42.1% taxi filters. Levels of fungal biomass were above the detection limit in 63% taxi filters and in 75% personal vehicle filters. No toxigenic species were detected by molecular analysis in the assessed filters. The results obtained show that bioburden proliferation occurs widely in filters from the air conditioning systems of taxis, including the proliferation of azole-resistant fungal species, suggesting that filters should be replaced more frequently. The use of culture based-methods and molecular tools combined enabled an improved risk characterization in this setting.

54 ENVIRONMENTAL SCIENCES↗

Occupational exposure in the fluorescent lamp recycling sector in France

Highlights: • Chemical risks were assessed in the five fluorescent lamp recycling facilities. • The main hazardous agents are mercury vapors and dust containing lead and yttrium. • Exposure and pollutant levels were correlated with steps and processes. • All the stages and processes are concerned by worrying levels of pollutants. • We suggest recommendations to reduce chemical risk. - Abstract: The fluorescent lamp recycling sector is growing considerably in Europe due to increasingly strict regulations aimed at inciting the consumption of low energy light bulbs and their end-of-life management. Chemical risks were assessed in fluorescent lamp recycling facilities by field measurement surveys in France, highlighting that occupational exposure and pollutant levels in the working environment were correlated with the main recycling steps and processes. The mean levels of worker exposure are 4.4 mg/m{sup 3}, 15.4 μg/m{sup 3}, 14.0 μg/m{sup 3}, 247.6 μg/m{sup 3}, respectively, for total inhalable dust, mercury, lead and yttrium. The mean levels of airborne pollutants are 3.1 mg/m{sup 3}, 9.0 μg/m{sup 3}, 9.0 μg/m{sup 3}, 219.2 μg/m{sup 3}, respectively, for total inhalable dust, mercury, lead and yttrium. The ranges are very wide. Surface samples from employees’ skin and granulometric analysis were also carried out. The overview shows that all the stages and processes involved in lamp recycling are concerned by the risk of hazardous substances penetrating into the bodies of employees, although exposure of the latter varies depending on the processes and tasks they perform. The conclusion of this study strongly recommends the development of a new generation of processes in parallel with more information sharing and regulatory measures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

3d-Orbital Occupancy Regulated Ir-Co Atomic Pair Toward Superior Bifunctional Oxygen Electrocatalysis

Atomically dispersed metal catalysts are hailed as the most promising catalyst category for oxygen electrocatalysis. However, the challenges in regulating electronic configuration and unveiling the mechanism on the atomic scale are hindering their practical implementation. Herein, we modulate the Co d-orbital electron configuration by constructing the Ir–Co atomic pair toward boosted bifunctional activity. The as-developed dual-atom IrCo–N–C catalyst displays unprecedented activity with a half-wave potential of 0.911 V for oxygen reduction reaction and only 330 mV overpotential at 10 mA cm –2 for oxygen evolution reaction, outperforming the single-atom counterparts as well as the commercial Pt/C and Ir/C benchmarks. The impressive bifunctionality is also verified in a Zn–air battery prototype with an ultra-high cyclability over 450 cycles. Furthermore, theoretical calculations are performed to shed light on the synergetic effects of the atomic pair site, where the incorporation of Ir atom alters the d-orbital energy level of Co and thus induces the re-arrangement of d-electron toward intensified spin polarization. As a result, the lower occupancy of d z 2 orbital facilitates the electron acceptation from oxygen to form a stronger Co–O σ bond, thereby propelling faster reaction kinetics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ta, Ti and Hf effects on Nb 3 Sn high-field performance: temperature-dependent dopant occupancy and failure of Kramer extrapolation

The increasing demand for improving the high-field (16-22 T) performance of Nb 3 Sn conductors requires a better understanding of the properties of modern wires much closer to irreversibility field, H Irr . In this study we investigated the impact of Ta, Ti and Hf doping on the high-field pinning properties, the upper critical field, H c2 , and H Irr . We found that the pinning force curves of commercial Ti and Ta doped wires at different temperatures do not scale and that the Kramer extrapolation, typically used by magnet designers to estimate high-field critical current density and magnet operational margins from lower field data, is not reliable and significantly overestimates the actual H Irr . In contrast, new laboratory scale conductors made with Nb-Ta-Hf alloy have improved high-field J c performance and, despite contributions by both grain boundary and point defect pinning mechanisms, have more predictable high-field behavior. Using Extended X-ray Absorption Fine Structure spectroscopy, EXAFS, we found that for the commercial Ta and Ti doped conductors, the Ta site occupancy in the A15 structure gradually changes with the heat treatment temperature whereas Ti is always located on the Nb site with clear consequences for H c2 . Finally, this work reveals the still limited understanding of what determines H c2 , H Irr and the high-field J c performance of Nb 3 Sn and the complexity of optimizing these conductors so that they can reach their full potential for high-field applications.

36 MATERIALS SCIENCE↗

Occupational Contamination with a Highly Enriched Uranium Solution

This medical case report describes the first reported instance of occupational skin contamination with a uranyl nitrate solution containing highly enriched uranium. The report provides an overview of the unique medical treatment and management considerations in such a case. Herein, internal dose assessment is covered in detail. The discussion covers key points regarding uranium characteristics, chemical and radiological damage to body tissues from HEU exposure, and resources available for assistance with a case of radiological contamination. This information adds to the limited medical literature on this topic and provides a valuable reference for medical personnel when dealing with this uncommon problem.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Unobtrusive Sensor-Based Occupancy Facing Direction Detection and Tracking Using Advanced Machine Learning Algorithms

Facing direction detection plays a critical role in human-computer interaction and has a wide application in surveillance systems, driving awareness recognition, smart home appliances, computer games, and so on. Current detection methods are mainly focused on extracting specific patterns from user's optical images, which raises concerns on privacy invasion and these detection techniques do not usually work in a dark environment. To address these concerns, here this paper proposes an activity recognition system guided by an unobtrusive sensor (ARGUS). By using a low pixel infrared thermopile array sensor, ARGUS is capable of identifying five facing directions (left 45°/90°, right 45°/90°, and front) through the support vector machine classifier. Also two feature extraction methods are compared. One is manually-defined and the other is based on a pre-trained convolutional neural network (CNN) model. The facing direction detection accuracy resulting from manually-defined features reaches 85.3%, 90.6%, and 85.2% at detection distance of 0.6, 1.2, and 1.8 m, respectively. The level of accuracy resulted from using pre-trained CNN features demonstrates a much more reliable performance (89.1%, 95.3%, and 95.1% at distance of 0.6, 1.2, and 1.8 m, respectively). In addition, ARGUS has been successfully applied for occupancy tracking with a root mean square error of 0.19 m.

42 ENGINEERING↗

Hanford Tank Farm Occupational Exposure and Risk Assessment Plan: Health Process Project (Rev.1)

The overall objective of the Hanford Tank Farm Occupational Exposure and Risk Assessment Plan (hereafter referred to as the “Assessment Plan”) is to provide the Tank Operations Contractor (TOC), Washington River Protection Solutions (WRPS), and the U.S. Department of Energy (DOE) with a plan for developing a transparent, peer-reviewed process for assessing potential health risks associated with worker exposures to chemical emissions from the Hanford tank farms. Revision 1 (2018) incorporates changes to the original draft plan prepared in 2016 to reflect updated strategies based on initial implementation of the recommended actions.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Evaluation of the Reliability of Passive Infrared (PIR) Occupancy Sensors for Residential Indoor Lighting

Solid-state lighting (SSL) technologies have penetrated the general illumination market in recent years, largely replacing conventional technologies such as incandescent and fluorescent lighting. Most of the initial excitement about light-emitting diode (LED) sources for SSL devices focused on their energy savings potential resulting from vast improvements in source efficiency and luminous efficacy compared with conventional illumination products. More recently, the focus has shifted toward other aspects of lighting application efficiency, namely intensity effectiveness and spectral efficiency, because of the ease of controlling both the light intensity of LEDs with drive voltage and the color properties of the LED-based illuminators. To capitalize on the energy savings of increased intensity effectiveness and spectral efficiency, a lighting control system (LCS) is often used. While the current penetration of LCSs is relatively modest, it is anticipated that lighting controls (i.e., connected lighting, controls and LED and conventional lighting) could have an installed penetration as higher as 46% by the year 2035, saving an additional 1.3 quads of energy. Despite the large energy savings that can be gained from using LCSs, standard test methods for evaluating sensors employed in LCSs and reliability data of the LCSs and their components are generally lacking. The National Electrical Manufacturers Association (NEMA) developed the only standard, NEMA WD 7-2011 (R2016), to test occupancy and motion sensor performance (herein referred to as “the NEMA protocol”). In a previous U.S. Department of Energy (DOE) effort, some concerns of the NEMA protocol were identified (e.g., strict height and weight limits on test subjects, large amounts of manual effort, sometimes inconsistent repeatability). During the current work, a consistent detection length test (DLT) and a Robotic Sensor Evaluation System (RoboSES) were developed to alleviate some of these concerns. RoboSES acts as a human surrogate by using thermal pads on a mannequin and a remote-controlled mobile base to test a sensor’s field of view (FOV). This report builds on the earlier DOE efforts to understand sensor technologies used in LCSs for general illumination. Specifically, this report describes the optimization of RoboSES, characterizes and establishes test methods to assess the reliability of multiple passive infrared (PIR) sensors, and reports the findings of robustness and reliability testing on two commercial PIR sensors intended for residential applications. The information presented in this report is gained from up to 4,000 hours (hrs) of accelerated stress tests (ASTs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Biokinetic data and models for occupational intake of lanthanoids

The lanthanoid (or lanthanide) chemical elements comprise fifteen elements with atomic numbers 57 (lanthanum) through 71 (lutetium). This paper reviews data related to the biological behavior of these elements in the human body and proposes biokinetic models for application to occupational intake of radio-lanthanoids. Generic (element-independent) absorption rates from the respiratory and alimentary tracts to blood are proposed. The proposed systemic models are largely generic but include some element-specific parameter values to reflect regular changes with ionic radius in certain aspects of the behavior of the lanthanoids. This work was performed within the internal dosimetry task group (INDOS) of Committee 2 of the International Commission on Radiological Protection (ICRP).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Human performance cognitive-behavioral modeling: a benefit for occupational safety

Human Performance Modeling (HPM) is a computer-aided job analysis software methodology used to generate predictions of complex human-automation integration and system flow patterns with the goal of improving operator and system safety. The use of HPM tools has recently been increasing due to reductions in computational cost, augmentations in the tools' fidelity, and usefulness in the generated output. An examination of an Air Man-machine Integration Design and Analysis System (Air MIDAS) model evaluating complex human-automation integration currently underway at NASA Ames Research Center will highlight the importance to occupational safety of considering both cognitive and physical aspects of performance when researching human error.

Occupational Health↗

Building America Case Study: Occupant Comfort from a Mini-Split Heat Pump, San Antonio, Texas

IBACOS worked with builder Imagine Homes to evaluate the performance of an occupied new construction test house following construction of the house in the hot, humid climate of San Antonio, Texas. The project measures the effectiveness of a space conditioning strategy using a multihead mini-split heat pump (MSHP) system in a reduced-load home to achieve acceptable comfort levels (temperature and humidity) and energy performance. IBACOS collected long-term data and analyzed the energy consumption and comfort conditions of the occupied house after one year of operation. Although measured results indicate that the test system provides comfort both inside and outside the ASHRAE Standard 55-2010 range, the occupants of the house claimed both adequate comfort and appreciation of the ease of use and flexibility of the installed MSHP system. IBACOS also assisted the builder to evaluate design and specification changes necessary to comply with Zero Energy Ready Home, but the builder chose to not move forward with it because of concerns about the 'solar ready' requirements of the program.

30 DIRECT ENERGY CONVERSION↗

An Unbalanced Battle in Excellence: Revealing Effect of Ni/Co Occupancy on Water Splitting and Oxygen Reduction Reactions in Triple–Conducting Oxides for Protonic Ceramic Electrochemical Cells

Porous electrodes that conduct electrons, protons, and oxygen ions with dramatically expanded catalytic active sites can replace conventional electrodes with sluggish kinetics in protonic ceramic electrochemical cells. In this work, a strategy is utilized to promote triple conduction by facilitating proton conduction in praseodymium cobaltite perovskite through engineering non-equivalent B-site Ni/Co occupancy. Surface infrared spectroscopy is used to study the dehydration behavior, which proves the existence of protons in the perovskite lattice. The proton mobility and proton stability are investigated by hydrogen/deuterium (H/D) isotope exchange and temperature-programmed desorption. It is observed that the increased nickel replacement on the B-site has a positive impact on proton defect stability, catalytic activity, and electrochemical performance. This doping strategy is demonstrated to be a promising pathway to increase catalytic activity toward the oxygen reduction and water splitting reactions. The chosen PrNi 0.7 Co 0.3 O 3–δ oxygen electrode demonstrates excellent full-cell performance with high electrolysis current density of –1.48 A cm –2 at 1.3 V and a peak fuel-cell power density of 0.95 W cm –2 at 600 °C and also enables lower-temperature operations down to 350 °C, and superior long-term durability.

08 HYDROGEN↗

Karlin–McGregor Mutational Occupancy Problem Revisited

Some population is made of n individuals that can be of p possible species (or types). The update of the species abundance occupancies is from a Moran mutational model designed by Karlin and McGregor in 1967. We first study the equilibrium species counts as a function of n, p and the total mutation probability ν before considering various asymptotic regimes on n, p and ν.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Full Detector Simulation with Unprecedented Background Occupancy at a Muon Collider

In recent years, a Muon collider has attracted a lot of interest in the high-energy physics community, thanks to its ability of achieving clean interaction signatures at multi-TeV collision energies in the most cost-effective way. Estimation of the physics potential of such an experiment must take into account the impact of beam-induced background on the detector performance, which has to be carefully evaluated using full detector simulation. Tracing of all the background particles entering the detector region in a single bunch crossing is out of reach for any realistic computing facility due to the unprecedented number of such particles. To make it feasible a number of optimisations have been applied to the detector simulation workflow. This contribution presents an overview of the main characteristics of the beam-induced background at a Muon collider, the detector technologies considered for the experiment and how they are taken into account to strongly reduce the number of irrelevant computations performed during the detector simulation. Special attention is dedicated to the optimisation of track reconstruction with the conformal tracking algorithm in this high-occupancy environment, which is the most computationally demanding part of event reconstruction.

97 MATHEMATICS AND COMPUTING↗

Data, exergy, and energy analysis of a vertical-bore, ground-source heat pump to for domestic water heating under simulated occupancy conditions

Evidence is provided to support the view that greater than two-thirds of energy required to produce domestic hot water may be extracted from the ground which serves as renewable energy resource. The case refers to a 345 m2 research house located in Oak Ridge, Tennessee, 36.01 N 84.26 W in a mixed-humid climate with HDD of 2218 C-days (3993 F-days) and CDD of 723 C-days (1301 F-days). The house is operated under simulated occupancy conditions in which the hot water use protocol is based on the Building America Research Benchmark Definition (Hendron 2008; Hendron and Engebrecht 2010) which captures the water consumption lifestyles of the average family in the United States. The 5.275 (1.5-ton) water-to-water ground source heat pump (WW-GSHP) shared the same vertical bore with a 7.56 KW water-to-air ground source heat pump for space conditioning the same house. Energy and exergy analysis of data collected continuously over a twelve month period provide performance metrics and sources of inherent systemic inefficiencies. Data and analyses are vital to better understand how WW-GSHPs may be further improved to enable the ground to be used as a renewable energy resource.

15 GEOTHERMAL ENERGY↗