Deep-learning-aided extraction of optical constants in scanning near-field optical microscopy

Scanning near-field optical microscopy is one of the most effective techniques for spectroscopy of nanoscale systems. However, inferring optical constants from the measured near-field signal can be challenging because of a complicated and highly nonlinear interaction between the scanned probe and the sample. Conventional fitting methods applied to this problem often suffer from the lack of convergence or require human intervention. Here, we develop an alternative approach where the optical parameter extraction is automated by a deep learning network. The network provides an initial estimate that is subsequently refined by a traditional fitting algorithm. In conclusion, we show that this method demonstrates superior accuracy, stability against noise, and computational speed when applied to simulated near-field spectra.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A cryogenic white light absorption spectroscopy setup with in situ gamma irradiation and thermo-optical annealing for optical fiber radiation-induced attenuation characterization

Silica optical fiber sensors offer a fast, distributed measurement solution in various cryogenic and radiation environments, such as magnets for fusion power. Under these conditions, light-absorbing point defects limit lifetime via radiation-induced attenuation (RIA). To support RIA kinetics prediction, we present an in situ, broadband absorption spectroscopy setup combining gamma irradiation with liquid nitrogen cooling. The apparatus enables continuous monitoring of narrowband RIA levels and the use of secondary optical annealing light sources, alongside broadband spectrum measurements to characterize RIA defects through spectrum decomposition. Initial results confirm the inevitable photobleaching effect of the probe light source, which must be accounted for. In addition, we report RIA kinetics during cycles of gamma irradiation at 77 K and isochronal thermal annealing steps from liquid nitrogen to room temperature, showcasing the setup’s ability to replicate real fiber operation scenarios. These instruments form an ideal platform to further study the kinetics of RIA coupled with thermal and optical annealing.

Absorption spectroscopy↗

Method of optical coherence tomography with parallel depth-resolved signal reception and fibre-optic phase modulators

The method of optical coherence tomography with the scheme of parallel reception of the interference signal (P-OCT) is developed on the basis of spatial paralleling of the reference wave by means of a phase diffraction grating producing the appropriate time delay in the Mach–Zehnder interferometer. The absence of mechanical variation of the optical path difference in the interferometer essentially reduces the time required for 2D imaging of the object internal structure, as compared to the classical OCT that uses the time-domain method of the image construction, the sensitivity and the dynamic range being comparable in both approaches. For the resulting field of the interfering object and reference waves an analytical expression is derived that allows the calculation of the autocorrelation function in the plane of photodetectors. For the first time a method of linear phase modulation by 2π is proposed for P-OCT systems, which allows the use of compact high-frequency (a few hundred kHz) piezoelectric cell-based modulators. For the demonstration of the P-OCT method an experimental setup was created, using which the images of the inner structure of biological objects at the depth up to 1 mm with the axial spatial resolution of 12 μm were obtained. (optical coherence tomography)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of haemodilution on the optical properties of blood during coagulation studied by optical coherence tomography

We report an investigation of the effects of blood dilution with hypertonic (7.5 %) and normal (0.9 %) saline on its optical properties during coagulation in vitro using optical coherence tomography. The light penetration depth and attenuation coefficient are obtained from the dependences of reflectance on the depth. Normal whole blood has served as the control group. The average coagulation time is equal to 420±16,418±16 and 358±14 s with blood volume replacement of 2 %, 11 %, and 20 % by 0.9 % normal saline, respectively. With 2 %, 11% and 20% blood volume replacement with 7.5 % hypertonic saline, the average coagulation time is 422±17,1160±45 and 1730±69 s, respectively. For normal whole blood, the average coagulation time amounts to 425±19 s. it is shown that dilution with normal saline has a procoagulant effect when it replaces 20 % of blood volume, and hypertonic saline has an anticoagulant effect if it replaces 11 % or more of blood volume. It is concluded that optical coherence tomography is a potential technique to quantify and monitor the liquid – gel transition during the coagulation process of blood diluted by normal and hypertonic saline. (biophotonics)

60 APPLIED LIFE SCIENCES↗

Laser optical frequency combs and their applications in optical fibre communication systems and astrophysics

This paper examines the generation and applications of laser optical frequency combs (LOFCs). The unique properties of LOFCs are widely used in spectroscopy and metrology, in particular for making ultra-accurate optical clocks. The use of LOFCs contributes to advances in optical fibre communication systems and studies pertaining to fundamental problems of astrophysics, such as the search for and investigation of exoplanets and verification of the hypothesis that physical constants vary with time. (invited paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Acousto-optic modulators for fibre-optic lines

The specific features of efficient matching of acousto-optic devices with single-mode fibres for the cases of isotropic and anisotropic diffraction are considered. The acousto-optic interaction geometry, optimal for modulating an arbitrarily polarised light beam with a possibility of tuning its frequency shift in the range up to ∼10 MHz, is chosen. Acousto-optic modulators/frequency shifters based on paratellurite (TeO{sub 2}), pigtailed with polarisation-maintaining and non-polarisation-maintaining fibres, have been developed for wavelengths of 1064 and 1550 nm, and their main technical parameters are investigated. (paper)

36 MATERIALS SCIENCE↗

TESTING THE APODIZED PUPIL LYOT CORONAGRAPH ON THE LABORATORY FOR ADAPTIVE OPTICS EXTREME ADAPTIVE OPTICS TESTBED

We present testbed results of the Apodized Pupil Lyot Coronagraph (APLC) at the Laboratory for Adaptive Optics (LAO). These results are part of the validation and tests of the coronagraph and of the Extreme Adaptive Optics (ExAO) for the Gemini Planet Imager (GPI). The apodizer component is manufactured with a halftone technique using black chrome microdots on glass. Testing this APLC (like any other coronagraph) requires extremely good wavefront correction, which is obtained to the 1 nm rms level using the microelectricalmechanical systems (MEMS) technology, on the ExAO visible testbed of the LAO at the University of Santa Cruz. We used an APLC coronagraph without central obstruction, both with a reference super-polished flat mirror and with the MEMS to obtain one of the first images of a dark zone in a coronagraphic image with classical adaptive optics using a MEMS deformable mirror (without involving dark hole algorithms). This was done as a complementary test to the GPI coronagraph testbed at American Museum of Natural History, which studied the coronagraph itself without wavefront correction. Because we needed a full aperture, the coronagraph design is very different from the GPI design. We also tested a coronagraph with central obstruction similar to that of GPI. We investigated the performance of the APLC coronagraph and more particularly the effect of the apodizer profile accuracy on the contrast. Finally, we compared the resulting contrast to predictions made with a wavefront propagation model of the testbed to understand the effects of phase and amplitude errors on the final contrast.

79 ASTRONOMY AND ASTROPHYSICS↗

Light scattering from ultracold atoms in optical lattices as an optical probe of quantum statistics

We study off-resonant collective light scattering from ultracold atoms trapped in an optical lattice. Scattering from different atomic quantum states creates different quantum states of the scattered light, which can be distinguished by measurements of the spatial intensity distribution, quadrature variances, photon statistics, or spectral measurements. In particular, angle-resolved intensity measurements reflect global statistics of atoms (total number of radiating atoms) as well as local statistical quantities (single-site statistics even without optical access to a single site) and pair correlations between different sites. As a striking example we consider scattering from transversally illuminated atoms into an optical cavity mode. For the Mott-insulator state, similar to classical diffraction, the number of photons scattered into a cavity is zero due to destructive interference, while for the superfluid state it is nonzero and proportional to the number of atoms. Moreover, we demonstrate that light scattering into a standing-wave cavity has a nontrivial angle dependence, including the appearance of narrow features at angles, where classical diffraction predicts zero. The measurement procedure corresponds to the quantum nondemolition measurement of various atomic variables by observing light.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Free Spectroscopic Databank of Optical Constants for Use in Optics Education and Modeling: complex refractive index data n and k from 1.0 to 25 um

The reflectance spectra of solid and liquids can be complicated since they depend not only on absorption, but also on the refraction, reflection, and scattering of light, all of which are wavelength dependent. The physical form and morphological effects associated with solid and liquid samples are thus known to affect their reflectance spectra in a non-linear fashion, particularly in the infrared. Measuring the optical constants n(?) and k(?) represents an alternative approach, allowing one to model these many effects and thus requiring fewer laboratory measurements. In this paper an overview is presented of the protocols used to measure the n/k optical constants, particularly for liquids. For the liquids, a multiple path length measurements approach is employed, and in this paper we demonstrate the method to determine the complex optical constants n(?) and k(?) of squalene. The resultant calculated spectra of 1 µm and 100 µm thick layers of squalene on an aluminum substrate as derived from the experimental n(?) and k(?) values are shown to demonstrate such effects. The public availability of the n(?)/k(?) data as well as solids hemispherical reflectance data are also discussed.

optical constants, refractive index, solids, Liqui↗

Compact MEMS-based Adaptive Optics Optical Coherence Tomography for Clinical Use

We describe a compact MEMS-based adaptive optics (AO) optical coherence tomography system with improved AO performance and ease of clinical use. A typical AO system consists of a Shack-Hartmann wavefront sensor and a deformable mirror that measures and corrects the ocular and system aberrations. Because of the limitation on the current deformable mirror technologies, the amount of real-time ocular-aberration compensation is restricted and small in the previous AO-OCT instruments. In this instrument, we proposed to add an optical apparatus to correct the spectacle aberrations of the patients such as myopia, hyperopia and astigmatism. This eliminated the tedious process of the trial lenses in clinical imaging. Different amount of spectacle aberration compensation was achieved by motorized stages and automated with the AO computer for ease of clinical use. In addition, the compact AO-OCT was optimized to have minimum system aberrations to reduce AO registration errors and improve AO performance.

59 BASIC BIOLOGICAL SCIENCES↗

Polarization-Controlled Topological Charge Inversion of Optical Vortices in Multielliptical Optical Fibers

Analytical expressions for higher-order modes with azimuthal number |ℓ|≥ 2and their propagation constants for multielliptical optical fibers exhibiting a torsional mechanical stress are obtained in the vicinity of the resonance twist-pitch values. It is demonstrated that the resonance modes represent a superposition of two optical vortices with identical circular polarization and opposite signs of the topological charge. The effect of topological-charge inversion of the output optical vortex controlled by a change of sign of the circular polarization of the input beam is predicted. This effect paves the way to creating a logical CNOT element based on multielliptical fibers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Acousto-Optic Commutation of Fiber-Optic Channels

An acousto-optic commutator of fiber-optic channels based on a ТеО{sub 2} two-coordinate deflector has been proposed and realized. The commutator yields switching of optical radiation from a single output waveguide into a two-dimensional input matrix of waveguides, or vice versa, switching from any matrix waveguide into a single output one. The main interrelated parameters have been obtained. It has been established that the commutator has a short response time of 2–10 μs, yields up to several hundreds of switching channels, low insertion losses of 2–5 dB, and a considerable inter-channel isolation from –35 to –60 dB. Experiments were performed for the output matrix containing 19 waveguides. The channel multiplexing operating mode of this commutator has been demonstrated, which is simultaneous transmission of a signal from the output waveguide into a given number of waveguides of the input matrix.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Resonant-type third-order optical nonlinearity and optical bandgap in multicomponent oxide glasses

Optical nonlinearity or the nonlinear hyperpolarizability of amorphous materials (e.g., glasses) is related directly to the complex third-order susceptibility. The imaginary part of third-order susceptibility affects negatively the maximum data rate in telecommunication systems. In addition, many transition metals containing glasses have bandgaps with semiconductor-like behavior. So, due to the necessity of operation near the absorption band edge, the study of optical nonlinearity and band structure in glasses is very essential. In this work, we investigated the relationship between the imaginary third-order nonlinear susceptibility and the bandgap of some different series of prepared oxide glasses. A universal empirical formula is given to correlate the imaginary part of the third-order nonlinear susceptibility of the glasses and their optical bandgaps. The obtained nonlinearity is discussed in view of available theories and mechanisms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultralow-threshold thin-film lithium niobate optical parametric oscillator

Materials with strong second-order ( χ <#comment/> ( 2 ) ) optical nonlinearity, especially lithium niobate, play a critical role in building optical parametric oscillators (OPOs). However, chip-scale integration of low-loss χ <#comment/> ( 2 ) materials remains challenging and limits the threshold power of on-chip χ <#comment/> ( 2 ) OPO. Here we report an on-chip lithium niobate optical parametric oscillator at the telecom wavelengths using a quasi-phase-matched, high-quality microring resonator, whose threshold power ( ∼ <#comment/> 30 µ <#comment/> W ) is 400 times lower than that in previous χ <#comment/> ( 2 ) integrated photonics platforms. An on-chip power conversion efficiency of 11% is obtained from pump to signal and idler fields at a pump power of 93 µW. The OPO wavelength tuning is achieved by varying the pump frequency and chip temperature. With the lowest power threshold among all on-chip OPOs demonstrated so far, as well as advantages including high conversion efficiency, flexibility in quasi-phase-matching, and device scalability, the thin-film lithium niobate OPO opens new opportunities for chip-based tunable classical and quantum light sources and provides a potential platform for realizing photonic neural networks.

Lu, Juanjuan (ORCID:0000000319389119)↗

Active Irradiation Testing of Temperature Sensing Capability of Clad Sapphire Optical Fibers with Type 2 Bragg Gratings using Optical Backscatter Reflectometry

This work investigated the temperature-sensing capabilities of Type II fiber Bragg gratings (FBGs) inscribed in sapphire optical fiber in the Ohio State University Research Reactor (OSURR). A Luna Innovations 4600 optical backscatter reflectometer (OBR) was used to interrogate FBGs in three sapphire optical fibers with an internal cladding that was developed by Ohio State. The sapphire fibers were fusion-spliced to silica lead fibers. In addition to the sapphire fibers, two silica fibers with the same Type II FBGs were included in the experiment as a reference. The fiber-based sensors were irradiated in the Central Irradiation Facility (CIF) of the OSURR for a total of 40 hours over 5 days at a reactor power of 450 kW, resulting in a total neutron fluence of approximately 2.5 × 10 18 n/cm 2 and a gamma dose of approximately 3.48 Grad. Two K-type thermocouples were included within the rig: one at the core centerline and the other 12 inches above the top of the core. The temperature was not actively controlled, but the thermocouples were used to provide a reference to which the fiber-based temperature measurements could be compared.

36 MATERIALS SCIENCE↗

Commercialization of a Non-Intrusive Optical (NIO) Technology to Measure Heliostat Optical Errors in Utility-Scale Concentrating Solar Power Plants: Final TCF Report

The drone-based Non-Intrusive Optical (NIO) Technology has been developed at NREL to allow for efficient and automated optical characterization of heliostats in Concentrating Solar Power (CSP) plants. For this project, the technology will be developed into a commercial tool package, including software and user-interface (UI), operations manual, and training and support services. The project team will partner with Tietronix to perform market assessment and stakeholder engagement, develop the tool package and business model, and perform data collection and analysis to demonstrate and refine the capabilities for use at a commercial plant. The team will collaborate with a commercial plant to conduct the data collection operations and provide optical error deliverables. The goal of the project is to advance the commercialization of the technology to a stage where a beta version can be demonstrated at additional commercial plants and developed into a licensable product.

14 SOLAR ENERGY↗

In-situ monitoring of surface post-processing in large aperture fused silica optics with Optical Coherence Tomography

Optical Coherence Tomography is explored as a method to image laser-damage sites located on the surface of large aperture fused silica optics during post-processing via CO{sub 2} laser ablation. The signal analysis for image acquisition was adapted to meet the sensitivity requirements for this application. A long-working distance geometry was employed to allow imaging through the opposite surface of the 5-cm thick optic. The experimental results demonstrate the potential of OCT for remote monitoring of transparent material processing applications.

36 MATERIALS SCIENCE↗

Performance of a MEMS-base Adaptive Optics Optical Coherency Tomography System

We have demonstrated that a microelectrical mechanical systems (MEMS) deformable mirror can be flattened to < 1 nm RMS within controllable spatial frequencies over a 9.2-mm aperture making it a viable option for high-contrast adaptive optics systems (also known as Extreme Adaptive Optics). The Extreme Adaptive Optics Testbed at UC Santa Cruz is being used to investigate and develop technologies for high-contrast imaging, especially wavefront control. A phase shifting diffraction interferometer (PSDI) measures wavefront errors with sub-nm precision and accuracy for metrology and wavefront control. Consistent flattening, required testing and characterization of the individual actuator response, including the effects of dead and low-response actuators. Stability and repeatability of the MEMS devices was also tested. An error budget for MEMS closed loop performance will summarize MEMS characterization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗