Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NOISE INTENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Effective potential and chiral symmetry breaking

The nonequilibrium effective potential is calculated for the Frank model of spontaneous mirror-symmetry breaking in chemistry in which external noise is introduced to account for random environmental effects. The well-mixed limit, corresponding to negligible diffusion, and the case of diffusion in two space dimensions are studied in detail. White noise has a disordering effect in the former case, whereas in the latter case a phase transition occurs for external noise exceeding a critical intensity which racemizes the system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-J-114: A Practical Hybrid Method for Improving the Quality of CT-CBCT Deformable Image Registration for Head and Neck Radiotherapy

Purpose: Accurate deformable image registration (DIR) between CT and CBCT in H&N is challenging. In this study, we propose a practical hybrid method that uses not only the pixel intensities but also organ physical properties, structure volume of interest (VOI), and interactive local registrations. Methods: Five oropharyngeal cancer patients were selected retrospectively. For each patient, the planning CT was registered to the last fraction CBCT, where the anatomy difference was largest. A three step registration strategy was tested; Step1) DIR using pixel intensity only, Step2) DIR with additional use of structure VOI and rigidity penalty, and Step3) interactive local correction. For Step1, a public-domain open-source DIR algorithm was used (cubic B-spline, mutual information, steepest gradient optimization, and 4-level multi-resolution). For Step2, rigidity penalty was applied on bony anatomies and brain, and a structure VOI was used to handle the body truncation such as the shoulder cut-off on CBCT. Finally, in Step3, the registrations were reviewed on our in-house developed software and the erroneous areas were corrected via a local registration using level-set motion algorithm. Results: After Step1, there were considerable amount of registration errors in soft tissues and unrealistic stretching in the posterior to the neck and near the shoulder due to body truncation. The brain was also found deformed to a measurable extent near the superior border of CBCT. Such errors could be effectively removed by using a structure VOI and rigidity penalty. The rest of the local soft tissue error could be corrected using the interactive software tool. The estimated interactive correction time was approximately 5 minutes. Conclusion: The DIR using only the image pixel intensity was vulnerable to noise and body truncation. A corrective action was inevitable to achieve good quality of registrations. We found the proposed three-step hybrid method efficient and practical for CT/CBCT registrations in H&N. My department receives grant support from Industrial partners: (a) Varian Medical Systems, Palo Alto, CA, and (b) Philips HealthCare, Best, Netherlands.

60 APPLIED LIFE SCIENCES↗

Plasma wave interactions with energetic ions near the magnetic equator

An intense band of electromagnetic noise is frequently observed near the magnetic equatorial plane at radial distance from about 2 to 5 Re. Recent wideband wave-form measurements with the IMP-6 and Hawkeye-1 satellites have shown that the equatorial noise consists of a complex superposition of many harmonically spaced lines. Several distinctly different frequency spacings are often evident in the same spectrum. The frequency spacing typically ranges from a few Hz to a few tens of Hz. It is suggested that these waves are interacting with energetic protons, alpha particles, and other heavy ions trapped near the magnetic equator. The possible role these waves play in controlling the distribution of the energetic ions is considered.

Gurnett, D. A.↗

Plasma wave interactions with energetic ions near the magnetic equator

An intense band of electromagnetic noise is frequently observed near the magnetic equatorial plane at radial distance from about 2 to 9 earth radii. Recent wide band wave form measurements with the Imp 6 and Hawkeye 1 satellites have shown that the equatorial noise consists of a complex superposition of many harmonically spaced lines. Several distinctly different frequency spacings are often evident in the same spectrum. The frequency spacing typically ranges from a few hertz to a few tens of hertz. The purpose of this paper is to suggest that these waves are interacting with energetic protons, alpha particles, and other heavy ions trapped near the magnetic equator. The possible role that these waves play in controlling the distribution of the energetic ions is considered.

Gurnett, D. A.↗

Implications of possible shuttle charging

Shuttle charging is discussed and two analyses of shuttle charging are performed. The first predicts the effective collecting area of a wire grid, biased with the respect to the potential of the magnetoplasma surrounding it. The second predicts the intensity of broadband electromagnetic noise that is emitted when surface electrostatic discharges occur between the beta cloth and the wire grid sewn on it.

Taylor, W. W. L.↗

Plasma waves near Saturn - Initial results from Voyager 1

The Voyager 1 plasma wave instrument detected many familiar types of plasma waves during the encounter with Saturn, including ion-acoustic waves and electron plasma oscillations upstream of the bow shock, an intense burst of electrostatic noise at the shock, and chorus, hiss, electrostatic electron cyclotron waves, and upper hybrid resonance emissions in the inner magnetosphere. A clocklike Saturn rotational control of low-frequency radio emissions was observed, and evidence was obtained of possible control by the moon Dione. Strong plasma wave emissions were detected at the Titan encounter indicating the presence of a turbulent sheath extending around Titan, and upper hybrid resonance measurements of the electron density show the existence of a dense plume of plasma being carried downstream of Titan by the interaction with the rapidly rotating magnetosphere of Saturn.

Gurnett, D. A.↗

Analytical and experimental evaluations of Space Shuttle TPS tile vibration response

Analytical studies and laboratory experiments have been performed to evaluate the vibration response of the Space Shuttle Thermal Protection System (TPS) tiles due to the intense rocket generated acoustic noise during lift-off. The TPS tiles are mounted over the exterior of the Space Shuttle Orbiter structure through Strain Isolation Pads (SIP) which protect the tiles from thermal induced shear loads at their interface. The analytical predictions indicate that the response of a typical tile is governed by the structural vibration inputs through the SIP under the tile at frequencies below 250 Hz, and by the direct acoustic excitation over the exterior surface of the tile at frequencies above 250 Hz. An evaluation of the laboratory test data for this same tile, in which conditioned (partial) coherent output spectral analysis procedures were used, leads to exactly the same conclusion. The results demonstrate the power of conditioned spectral analysis procedures in identifying vibration response mechanisms when two or more of the inputs are highly correlated.

Piersol, A. G.↗

Light aircraft sound transmission study

The plausibility of using the two microphone sound intensity technique to study noise transmission into light aircraft was investigated. In addition, a simple model to predict the interior sound pressure level of the cabin was constructed.

Heitman, K.↗

Holographic interferometry with an injection seeded Nd:YAG laser and two reference beams

The performance of twin injection seeded Nd:YAG lasers is compared with the performance of an argon-ion laser for recording dual-reference-beam holograms in AGFA 8E56 emulsion. Optical heterodyning is used to measure interference, and the results are expressed in terms of heterodyning signal level and intensity signal-to-noise. The Nd:YAG laser system is to be used for optical inspections of structures for cracks, defects, gas leaks, and structural changes.

Decker, Arthur J.↗

Experimental assessment of helicopter rotor turbulence ingestion noise in hover

An experiment was conducted to assess the accuracy of a theory for non-isotropic turbulence ingestion. In order to generate non-isotropic turbulence in a controlled environment, a scale model rotor in a closed chamber was used so that the turbulence generated by the rotor was reingested by the recirculating flow. Simultaneous measurements of turbulence inflow properties and far field acoustics were acquired. Measurements confirmed that the inflow turbulence was highly non-isotropic. The measured aerodynamic properties were used as inputs for the noise prediction procedure. The general agreement between the non-isotropic noise prediction procedure and the experiment was good, although the procedure generally overpredicts the quasi-tonal low to mid range frequencies and underpredicts the higher broadband signals. The predicted sound power level as a function of polar angle was in close agreement with measurements, except near the rotor plane, which is not modeled by the present analysis. It is determined that the most sensitive parameter influencing the predicted noise was the turbulence intensity.

Simonich, J. C.↗

Holographic interferometry with an injection seeded Nd:YAG laser and two reference beams

The performance of twin injection seeded Nd:YAG lasers is compared with the performance of an argon-ion laser for recording dual-reference-beam holograms in AGFA 8E56 emulsion. Optical heterodyning is used to measure interference, and the results are expressed in terms of heterodyning signal level and intensity signal-to-noise. The Nd:YAG laser system is to be used for optical inspections of structures for cracks, defects, gas leaks, and structural changes.

Decker, Arthur J.↗

A quantitative assessment of RFI in the near-earth environment

This paper reviews the known sources of RF noise, their spectral and intensity characteristics, and how serious a threat each represents to monitoring in the earth's neighborhood. It is clear that the quietest frequency/time regime for monitoring galactic and extragalactic sources is over the dayside of the earth in the 0.8-10 MHz band. Observations made in 1969 from RAE-1 achieved an interference-free duty cycle of nearly 50 percent in the band below 4 MHz on the nightside of the planet. It is felt that, by going to an altitude of about 10 Re, observations during the present epoch could match or exceed the 1969 RAE observing conditions, particularly on the dayside of the planet.

Desch, Michael D.↗

Space Shuttle Crawler Transporter Sound Attenuation Study

The crawler transporter (CT) is the world's largest tracked vehicle known, weighing 6 million pounds with a length of 131 feet and a width of 113 feet. The Kennedy Space Center (KSC) has two CTs that were designed and built for the Apollo program in the 1960's, maintained and retrofitted for use in the Space Shuttle program. As a key element of the Space Shuttle ground systems, the crawler transports the entire 12-million-pound stack comprising the orbiter, the mobile launch platform (MLP), the external tank (ET), and the solid rocket boosters (SRB) from the Vehicle Assembly Building (VAB) to the launch pad. This rollout, constituting a 3.5-5.0-mile journey at a top speed of 0.9 miles-per-hour, requires over 8 hours to reach either Launch Complex 39A or B. This activity is only a prelude to the spectacle of sound and fury of the Space Shuttle launch to orbit in less than 10 minutes and traveling at orbital velocities of Mach 24. This paper summarizes preliminary results from the Crawler Transporter Sound Attenuation Study, encompassing test and engineering analysis of significant sound sources to measure and record full frequency spectrum and intensity of the various noise sources and to analyze the conditions of vibration. Additionally, data such as ventilation criteria, plus operational procedures were considered to provide a comprehensive noise suppression design for implementation. To date, sound attenuation study and results on Crawler 2 have shown significant noise reductions ranging from 5 to 24 dBA.

Margasahayam, Ravi N.↗

Truncated non-linear interferometer-based sensor system

A truncated non-linear interferometer-based sensor system includes an input that receives an optical beam and a non-linear amplifier that generates a probe beam and a conjugate beam from the optical beam. The system's local oscillators are related to the probe beam and the conjugate beam. The system includes a sensor that transduces an input with the probe beam and the conjugate beam. The transduction detects changes in the phase of each of the probe beam and the conjugate beam. The system's phase sensitive detectors detect phase modulations between the respective local oscillators, the probe beam, and the conjugate beam and outputs phase signals based on detected phase modulations. The system measures phase signals indicative of the sensor's input resulting from a sum or difference of the phase signals. The measurement exhibits a quantum noise reduction in an intensity difference, a phase sum, or an amplitude difference quadrature.

47 OTHER INSTRUMENTATION↗

Truncated nonlinear interferometer-based sensor system

A truncated non-linear interferometer-based sensor system includes an input port that receives an optical beam and a non-linear amplifier that amplifies the optical beam with a pump beam and renders a probe beam and a conjugate beam. The system's local oscillators have a relationship with the respective beams. The system includes a sensor that transduces an input with the probe beam and the conjugate beam or their respective local oscillators. It includes one or more phase-sensitive detectors that detect a phase modulation between the respective local oscillators and the probe beam and the conjugate beam. Output from the phase-sensitive-detectors is based on the detected phase modulation. The phase-sensor-detectors include measurement circuitry that measure the phase signals. The measurement is the sum or difference of the phase signals in which the measured combination exhibit a quantum noise reduction in an intensity difference or a phase sum or an amplitude difference quadrature.

Pooser, Raphael C.↗

Lip noise generated by flow separation from nozzle surfaces

Flow separation from nozzle surfaces can be a source of significant noise in addition to the jet noise. When no flow separation region exists only jet noise is observed at every angle, for velocities down to 120 m/sec, with both low and high levels of initial turbulence. Intense nearly periodic turbulence and noise is caused by flow separation from the thin core nozzle lip of a coaxial nozzle. This can be described by a combination of aeolian tone and trailing edge noise theory. Noise caused by flow separation from the surfaces of other nozzle geometries has somewhat different characteristics.

Olsen, W.↗

Reliable detection of fluence anomalies in EPID-based IMRT pretreatment quality assurance using pixel intensity deviations

Purpose: This work uses repeat images of intensity modulated radiation therapy (IMRT) fields to quantify fluence anomalies (i.e., delivery errors) that can be reliably detected in electronic portal images used for IMRT pretreatment quality assurance. Methods: Repeat images of 11 clinical IMRT fields are acquired on a Varian Trilogy linear accelerator at energies of 6 MV and 18 MV. Acquired images are corrected for output variations and registered to minimize the impact of linear accelerator and electronic portal imaging device (EPID) positioning deviations. Detection studies are performed in which rectangular anomalies of various sizes are inserted into the images. The performance of detection strategies based on pixel intensity deviations (PIDs) and gamma indices is evaluated using receiver operating characteristic analysis. Results: Residual differences between registered images are due to interfraction positional deviations of jaws and multileaf collimator leaves, plus imager noise. Positional deviations produce large intensity differences that degrade anomaly detection. Gradient effects are suppressed in PIDs using gradient scaling. Background noise is suppressed using median filtering. In the majority of images, PID-based detection strategies can reliably detect fluence anomalies of {>=}5% in {approx}1 mm{sup 2} areas and {>=}2% in {approx}20 mm{sup 2} areas. Conclusions: The ability to detect small dose differences ({<=}2%) depends strongly on the level of background noise. This in turn depends on the accuracy of image registration, the quality of the reference image, and field properties. The longer term aim of this work is to develop accurate and reliable methods of detecting IMRT delivery errors and variations. The ability to resolve small anomalies will allow the accuracy of advanced treatment techniques, such as image guided, adaptive, and arc therapies, to be quantified.

60 APPLIED LIFE SCIENCES↗

Additive evaluation criteria for aircraft noise

The occurrence of unexpected aircraft noise events will frequently evoke intense complaints about annoyance over such events. It is recognized that the relationship between the volume of complaints and the corresponding maximum noise levels does in fact depend on the circumstances of the complainants and the time of year. The frequency of occurrence of the respective noise events is also a factor. The possible practical value of the addition of the maximal noise level, to the well-known cumulative noise descriptors L(sub eq), L(sub dn), etc. may be considered. One might start by considering the difference between the L(sub eq) and the average maximal noise level of the twenty loudest single noise events on an average day. A somewhat less sharply focused consideration of the maximum noise levels was adopted. In that standard the scope of noise-mitigation measures is defined generally with reference to L(sub eq). If the average maximal noise level L(sub max) of the entire aircraft fleet mix exceeds the L(sub eq) by more than 20 dB(A) and if more than 20 daily aircraft noise events exceed the L(sub eq) than the difference L(sub max)-20 becomes the key criterion for noise-mitigation measures. A statistical correlation of a large number of data from aircraft-noise-monitoring sensors located both directly underneath and laterally disposed to an aircraft flight-path has supplied a basis for the determination of the distribution of the maximal noise levels about the average value, L(sub max), of each type of aircraft. This distribution is given for the takeoff climb and for the landing approach.

Meyer, Thomas J.↗