Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NOISE ATTENUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Modeling and analyzing parasitic parameters in high frequency converters

This research focuses on electromagnetic interference (EMI) / electromagnetic compatibility (EMC) design and analysis in power electronics systems. To limit the EMI under the standards, different methods and strategies are investigated. Parasitic parameters of high frequency (HF) transformer are analyzed using a novel analytical method, finite element method (FEM), and experimental measurements for different structures and windings arrangements. Also, the magnetic field, electric field, electric displacement, and electric potential distribution are simulated and analyzed. Moreover, a high voltage system is considered and analyzed to improve the EMC. The EMI propagation paths are analyzed. The EMI noise level of the system is obtained and compared to the IEC61800-3 standard. To improve the EMC, the parasitic parameters of the transformer, as the main path of EMI circulation, are analyzed and optimized to block the propagation. Furthermore, the geometry structure of the HF transformer is optimized to lower the parasitics in the system. Three pareto-optimal techniques are investigated for the optimization. The models and results are verified by 3D-FEM and experimental results for several given scenarios. Furthermore, the EMC modeling and conducted EMI analysis are developed for a system including an AC-DC-DC power supply (rectifier and dual active bridge (DAB) converter). Moreover, the common mode (CM) EMI noise propagation through the system is discussed and the noise sources and effect of components on the noise are analyzed. Additionally, the CM impedance of different parts of the system and the noise levels are discussed. Finally, EMI attenuation techniques were applied to the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coupling of Helmholtz resonators to improve acoustic liners for turbofan engines at low frequency

An analytical and test program was conducted to evaluate means for increasing the effectiveness of low frequency sound absorbing liners for aircraft turbine engines. Three schemes for coupling low frequency absorber elements were considered. These schemes were analytically modeled and their impedance was predicted over a frequency range of 50 to 1,000 Hz. An optimum and two off-optimum designs of the most promising, a parallel coupled scheme, were fabricated and tested in a flow duct facility. Impedance measurements were in good agreement with predicted values and validated the procedure used to transform modeled parameters to hardware designs. Measurements of attenuation for panels of coupled resonators were consistent with predictions based on measured impedance. All coupled resonator panels tested showed an increase in peak attenuation of about 50% and an increase in attenuation bandwidth of one one-third octave band over that measured for an uncoupled panel. These attenuation characteristics equate to about 35% greater reduction in source perceived noise level (PNL), relative to the uncoupled panel, or a reduction in treatment length of about 24% for constant PNL reduction. The increased effectiveness of the coupled resonator concept for attenuation of low frequency broad spectrum noise is demonstrated.

Dean, L. W.↗

Large-Scale Simulations and Detailed Flow Field Measurements for Turbomachinery Aeroacoustics

The presentation is a review of recent work in highly loaded compressors, turbine aeroacoustics and cooling fan noise. The specific topics are: the importance of correct numerical modeling to capture blade row interactions in the Ultra Efficient Engine Technology Proof-of-Concept Compressor, the attenuation of a detonation pressure wave by an aircraft axial turbine stage, current work on noise sources and acoustic attenuation in turbines, and technology development work on cooling fans for spaceflight applications. The topic areas were related to each other by certain themes such as the advantage of an experimentalist s viewpoint when analyzing numerical simulations and the need to improve analysis methods for very large numerical datasets.

VanZante, Dale↗

Summary of HEAT 1 Aeroacoustics Installation Effects

A critical part of the NASA High-Speed Research (HSR) program is the demonstration of satisfactory suppression of the jet noise present at low airspeeds. One scheme for reducing jet exhaust noise generated by a future High-Speed Civil Transport (HSCT) is the use of a mixer/ ejector system which would entrain large quantities of ambient air into the exhaust flow from the powerplant in order to cool and slow the jet exhaust before it leaves the tailpipe. Of the variety of factors which can affect the noise suppression characteristics of the mixer/ejector system, the influence of the wing flow field and high-lift devices is not well understood. The effectiveness of the noise suppression device must be evaluated in the presence of the wing/high-lift system before definitive assessments can be made concerning HSCT noise. Of nearly equal importance is the evaluation of the performance of the high-lift system(s) in the presence of realistic propulsion units which feature high ambient flow entrainment rates and jet thrust coefficients. These noise suppressors must provide the required acoustic attenuation while not overly degrading the thrust efficiency of the propulsion system or the lift enhancement of the high-lift devices on the wing. The overall objective of the NASA High-lift Engine Aeroacoustics Technology program is to demonstrate satisfactory interaction between the jet noise suppressor and the high-lift system at airspeeds and angles of attack consistent with takeoff, climb, approach, and landing. In support of this program, an isolated aeroacoustic test of a 13.5%-scale, candidate mixer/ejector nozzle was performed in the Ames' Research Center 40- by 80-Foot Wind Tunnel. The purpose of the test was to measure the baseline aeroacoustic performance characteristics of this nozzle in isolation from the aerodynamic flowfield induced by an HSCT airframe. The test documented the acoustic signature of the nozzles with treated and hardwall ejector surfaces and with changes in the ratio of ejector-duct-to-jet-area over a wide range range of nozzle pressure ratios and freestream Mach numbers. The test also measured the thrust performance, ambient-flow aspiration ratio, and internal and external static pressures on the nozzles. The isolated aeroacoustic performance data has been compared with results obtained with this nozzle installed on a 13.5% Boeing Reference H HSCT configuration, semi-span model. The semi-span, aeroacoustics integration test documented the first-order effects of the airframe flowfield on the acoustic performance of the nozzle and the effect of the nozzle secondary inlet flows on the aerodynamic performance of the wing high-lift systems. This investigation is critical to understanding the mutual installation effects of mixer/ejector nozzles and wing high-lift systems.

Smith, Brian E.↗

SU-F-I-58: Image Quality Comparisons of Different Motion Magnitudes and TR Values in MR-PET

Purpose: The aim of this work is to evaluate the accuracy and sensitivity of a respiratory-triggered MR-PET protocol in detecting four different sized lesions at two different magnitudes of motion, with two different TR values, using a novel PET-MR-CT compatible respiratory motion phantom. Methods: The eight-compartment torso phantom was setup adjacent to the motion stage, which moved four spherical compartments (28, 22, 17, 10 mm diameter) in two separate (1 and 2 cm) linear motion profiles, simulating a 3.5 second respiratory cycle. Scans were acquired on a 3T MR-PET system (Biograph mMR; Siemens Medical Solutions, Germany). MR measurements were taken with: 1) Respiratory-triggered T2-weighted turbo spin echo (BLADE) sequence in coronal orientation, and 2) Real-time balanced steady-state gradient echo sequence (TrueFISP) in coronal and sagittal planes. PET was acquired simultaneously with MR. Sphere geometries and motion profiles were measured and compared with ground truths for T2 BLADE-TSE acquisitions and real time TrueFISP images. PET quantification and geometry measurements were taken using standardized uptake values, voxel intensity plots and were compared with known values, and examined alongside MR-based attenuation maps. Contrast and signal-to-noise ratios were also compared for each of the acquisitions as functions of motion range and TR. Results: Comparison of lesion diameters indicate the respiratory triggered T2 BLADE-TSE was able to maintain geometry within −2 mm for 1 cm motion for both TR values, and within −3.1 mm for TR = 2000 ms at 2 cm motion. Sphere measurements in respiratory triggered PET images were accurate within +/− 5 mm for both ranges of motion for 28, 22, and 17 mm diameter spheres. Conclusion: Hybrid MR-PET systems show promise in imaging lung cancer in non-compliant patients, with their ability to acquire both modalities simultaneously. However, MR-based attenuation maps are still susceptible to motion derived artifacts and pose the potential to affect PET accuracy.

60 APPLIED LIFE SCIENCES↗

Dual energy exposure control (DEEC) for computed tomography: Algorithm and simulation study

DECT means acquiring the same object at two different energies, respectively two different tube voltages U{sub 1} and U{sub 2}. The raw data q{sub 1} and q{sub 2} undergo a decomposition process of type p=p(q{sub 1},q{sub 2}). The raw data p are reconstructed to obtain monochromatic images of the attenuation {mu}, of the object density {rho}, or of a specific material distribution. Recent advances in DECT focus on noise reduction techniques [S. Richard and J. H. Siewerdsen, Med. Phys. 35(2), 586-600 (2008)] and enable high performance DECT such as lung nodule detection [Shkumat et al., Med. Phys. 35(2), 629-632 (2008)]. Given p and a raw data-based projection-wise patient dose estimation D({alpha}) the authors determine the optimal tube current curves I{sub 1}({alpha}) and I{sub 2}({alpha}), with {alpha} being the view angle, which minimizes image noise for a given patient dose level. DEEC can perform online; I{sub 1}({alpha}) and I{sub 2}({alpha}) can be determined during the scan. Simulation studies using semianthropomorphic phantom data were carried out. In particular, functions p that generate {mu}-images and density images were evaluated. Image quality was compared to standard scans at U{sub 0}=120 kV (clinical CT) and U{sub 0}=45 kV (micro-CT) that were taken at the same dose level (D{sub 0}=D{sub 1}+D{sub 2}) and identical spatial resolution. Appropriate choice of p(q{sub 1},q{sub 2}) allows to obtain {mu}-images that show fewer artifacts and yield image noise levels comparable to the noise of the standard scan. The authors compared the standard scan to {mu}-images at 70 keV, which is the effective energy used in clinical CT, and found optimal results with {mu}-images at 25 keV for micro-CT. Nonoptimal choice of the decomposition function will, however, significantly increase image noise. In particular {mu}-images at 511 keV, as needed for PET/CT attenuation correction, exhibit more than twice as much image noise as the standard scan. With DEEC, which guarantees best dose usage possible, monochromatic images are generated with only slightly increased noise levels at the same dose compared to a standard scan. The benefit of significantly decreased artifacts appears to allow using DEEC-generated monochromatic images in daily routine. Furthermore, DEEC is not restricted to DECT and the inherent tube current modulation algorithm may also be applied to single energy CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ATS-6 attenuation diversity measurements at 20 and 30 GHz

The results of data obtained at The University of Texas at Austin in conjunction with the ATS-6 millimeter wave experiment are presented. Attenuation measurements at 30 GHz and sky noise data at 20 GHz were obtained simultaneously at each of two sites separated by 11 km. Space diversity reduces outage time for a system in Austin, Texas with a 10 dB fade margin at 30 GHz from 15 hours to 16 minutes per year. The maximum cloud height shows a good correlation to the maximum attenuations measured.

Vogel, W. J.↗

Attenuation diversity measurements at 20 and 30 GHz

The results of data obtained at The University of Texas at Austin in conjunction with the ATS-6 millimeter wave experiment are presented. Attenuation measurements at 30 GHz and sky noise data at 20 GHz were obtained for 93 days simultaneously at each of two sites separated by 11 km and for 314 days at one site. The ratio of the loss at 30 GHz to that at 20 GHz due to rain varied from about 2 to about 4 with a median value of 2.65. This value was used to estimate 30 GHz losses for the 38.6% of time during attenuation events for which the satellite link was not available. Space diversity reduced outage time for a system in Austin, Texas, with a 10 db fade margin at 30 GHz from 3.8 hours to 4.1 minutes for the 93 days. Extrapolated to a yearly base this corresponds to 15 hours and to 16 minutes respectively. A plot of maximum observed cloud height against maximum hourly attenuation indicates that for a given attenuation level a lower limit is set for the maximum cloud height.

Vogel, W. J.↗

SU-F-J-71: Improving CT Quality for Radiation Therapy Planning and Delivery Guidance Using a Non-Linear Contrast Enhancement Technique

Purpose: Advanced image post-processing techniques which enhance soft-tissue contrast in CT have not been widely employed for RT planning or delivery guidance. The purpose of this work is to assess the soft-tissue contrast enhancement from non-linear contrast enhancing filters and its impact in RT. The contrast enhancement reduces patient alignment uncertainties. Methods: Non-linear contrast enhancing methods, such as Best Contrast (Siemens), amplify small differences in X-ray attenuation between two adjacent structure without significantly increasing noise. Best Contrast (BC) separates a CT into two frequency bands. The low frequency band is modified by a non-linear scaling function before recombination with the high frequency band. CT data collected using a CT-on-rails (Definition AS Open, Siemens) during daily CT-guided RT for 6 prostate cancer patients and an image quality phantom (The Phantom Laboratory) were analyzed. Images acquired with a standard protocol (120 kVp, 0.6 pitch, 18 mGy CTDIvol) were processed before comparison to the unaltered images. Contrast and noise were measured in the the phantom. Inter-observer variation was assessed by placing prostate contours on the 12 CT study sets, 6 enhanced and 6 unaltered, in a blinded study involving 8 observers. Results: The phantom data demonstrate that BC increased the contrast between the 1.0% supra-slice element and the background substrate by 46.5 HU while noise increased by only 2.3 HU. Thus the contrast to noise ratio increased from 1.28 to 6.71. Furthermore, the variation in centroid position of the prostate contours was decreased from 1.3±0.4 mm to 0.8±0.3 mm. Thus the CTV-to-PTV margin was reduced by 1.1 mm. The uncertainty in delineation of the prostate/rectum edge decreased by 0.5 mm. Conclusion: As demonstrated in phantom and patient scans the BC filter accentuates soft-tissue contrast. This enhancement leads to reduced inter-observer variation, which should improve RT planning and delivery. Supported by Siemens.

60 APPLIED LIFE SCIENCES↗

Dose reduction using a dynamic, piecewise-linear attenuator

Purpose: The authors recently proposed a dynamic, prepatient x-ray attenuator capable of producing a piecewise-linear attenuation profile customized to each patient and viewing angle. This attenuator was intended to reduce scatter-to-primary ratio (SPR), dynamic range, and dose by redistributing flux. In this work the authors tested the ability of the attenuator to reduce dose and SPR in simulations. Methods: The authors selected four clinical applications, including routine full field-of-view scans of the thorax and abdomen, and targeted reconstruction tasks for an abdominal aortic aneurysm and the pancreas. Raw data were estimated by forward projection of the image volume datasets. The dynamic attenuator was controlled to reduce dose while maintaining peak variance by solving a convex optimization problem, assuminga priori knowledge of the patient anatomy. In targeted reconstruction tasks, the noise in specific regions was given increased weighting. A system with a standard attenuator (or “bowtie filter”) was used as a reference, and used either convex optimized tube current modulation (TCM) or a standard TCM heuristic. The noise of the scan was determined analytically while the dose was estimated using Monte Carlo simulations. Scatter was also estimated using Monte Carlo simulations. The sensitivity of the dynamic attenuator to patient centering was also examined by shifting the abdomen in 2 cm intervals. Results: Compared to a reference system with optimized TCM, use of the dynamic attenuator reduced dose by about 30% in routine scans and 50% in targeted scans. Compared to the TCM heuristics which are typically used withouta priori knowledge, the dose reduction is about 50% for routine scans. The dynamic attenuator gives the ability to redistribute noise and variance and produces more uniform noise profiles than systems with a conventional bowtie filter. The SPR was also modestly reduced by 10% in the thorax and 24% in the abdomen. Imaging with the dynamic attenuator was relatively insensitive to patient centering, showing a 17% increase in peak variance for a 6 cm shift of the abdomen, instead of an 82% increase in peak variance for a fixed bowtie filter. Conclusions: A dynamic prepatient x-ray attenuator consisting of multiple wedges is capable of achieving substantial dose reductions and modest SPR reductions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Design and preliminary test results at Mach 5 of an axisymmetric slotted sound shield

The basic theory and sound attenuation mechanisms, the design procedures, and preliminary experimental results are presented for a small axisymmetric sound shield for supersonic wind tunnels. The shield consists of an array of small diameter rods aligned nearly parallel to the entrance flow with small gaps between the rods for boundary layer suction. Results show that at the lowest test Reynolds number (based on rod diameter) of 52,000 the noise shield reduced the test section noise by about 60 percent ( or 8 db attenuation) but no attenuation was measured for the higher range of test reynolds numbers from 73,000 to 190,000. These results are below expectations based on data reported elsewhere on a flat sound shield model. The smaller attenuation from the present tests is attributed to insufficient suction at the gaps to prevent feedback of vacuum manifold noise into the shielded test flow and to insufficient suction to prevent transition of the rod boundary layers to turbulent flow at the higher Reynolds numbers. Schlieren photographs of the flow are shown.

Beckwith, I. E.↗

Performance of direct and iterative algorithms on an optical systolic processor

The frequency-multiplexed optical linear algebra processor (OLAP) is treated in detail with attention to its performance in the solution of systems of linear algebraic equations (LAEs). General guidelines suitable for most OLAPs, including digital-optical processors, are advanced concerning system and component error source models, guidelines for appropriate use of direct and iterative algorithms, the dominant error sources, and the effect of multiple simultaneous error sources. Specific results are advanced on the quantitative performance of both direct and iterative algorithms in the solution of systems of LAEs and in the solution of nonlinear matrix equations. Acoustic attenuation is found to dominate iterative algorithms and detector noise to dominate direct algorithms. The effect of multiple spatial errors is found to be additive. A theoretical expression for the amount of acoustic attenuation allowed is advanced and verified. Simulations and experimental data are included.

Ghosh, A. K.↗

Improved Broadband Liner Optimization Applied to the Advanced Noise Control Fan

The broadband component of fan noise has grown in relevance with the utilization of increased bypass ratio and advanced fan designs. Thus, while the attenuation of fan tones remains paramount, the ability to simultaneously reduce broadband fan noise levels has become more desirable. This paper describes improvements to a previously established broadband acoustic liner optimization process using the Advanced Noise Control Fan rig as a demonstrator. Specifically, in-duct attenuation predictions with a statistical source model are used to obtain optimum impedance spectra over the conditions of interest. The predicted optimum impedance information is then used with acoustic liner modeling tools to design liners aimed at producing impedance spectra that most closely match the predicted optimum values. Design selection is based on an acceptance criterion that provides the ability to apply increased weighting to specific frequencies and/or operating conditions. Constant-depth, double-degree of freedom and variable-depth, multi-degree of freedom designs are carried through design, fabrication, and testing to validate the efficacy of the design process. Results illustrate the value of the design process in concurrently evaluating the relative costs/benefits of these liner designs. This study also provides an application for demonstrating the integrated use of duct acoustic propagation/radiation and liner modeling tools in the design and evaluation of novel broadband liner concepts for complex engine configurations.

Nark, Douglas M.↗

Phase-weighted slant stacking for surface wave dispersion measurement

SUMMARY Surface wave retrieval from ambient noise records using seismic interferometry techniques has been widely used for multiscale shear wave velocity (Vs) imaging. One key step during Vs imaging is the generation of dispersion spectra and the extraction of a reliable dispersion curve from the retrieved surface waves. However, the sparse array geometry usually affects the ability for high-frequency (>1 Hz) seismic signals’ acquisition. Dispersion measurements are degraded by array response due to sparse sampling and often present smeared dispersion spectra with sidelobe artefacts. Previous studies usually focus on interferograms’ domain (e.g. cross-correlation function) and attempt to enhance coherent signals before dispersion measurement. We propose an alternative technique to explicitly deblur dispersion spectra through use of a phase-weighted slant-stacking algorithm. Numerical examples demonstrate the strength of the proposed technique to attenuate array responses as well as incoherent noise. Three different field examples prove the flexibility and superiority of the proposed technique: the first data set consists of ambient noise records acquired using a nodal seismometer array; the second data set utilizes distributed acoustic sensing (DAS) and a marine fibre-optic cable to acquire a similar ambient noise data set; the last data set is a vibrator-based active-source surface wave data. The enhanced dispersion measurements provide cleaner and higher-resolution spectra without distortions which will assist both human interpreters as well as ML algorithms in efficiently picking curves for subsequent Vs inversion.

58 GEOSCIENCES↗

Methods of reducing low frequency cabin noise and sonically induced stresses, based on the intrinsic structural tuning concept

Control of low frequency interior noise has been difficult in all commercial and general aviation aircraft, since the existing sound attenuation techniques are less effective at these frequencies. Therefore low frequency cabin noise and sonically induced stresses can be reduced mainly by a proper design of the fuselage structure. For this purpose, a concept based on intrinsic tuning and damping of fuselage structural elements has been under development at Boeing for the past three years. This paper describes the results of some laboratory and field tests that were conducted for evaluation of the concept.

Sengupta, G.↗

Seeing through noise in power laws

Despite widespread claims of power laws across the natural and social sciences, evidence in data is often equivocal. Modern data and statistical methods reject even classic power laws such as Pareto’s law of wealth and the Gutenberg–Richter law for earthquake magnitudes. We show that the maximum-likelihood estimators and Kolmogorov–Smirnov (K-S) statistics in widespread use are unexpectedly sensitive to ubiquitous errors in data such as measurement noise, quantization noise, heaping and censorship of small values. This sensitivity causes spurious rejection of power laws and biases parameter estimates even in arbitrarily large samples, which explains inconsistencies between theory and data. We show that logarithmic binning by powers of λ > 1 attenuates these errors in a manner analogous to noise averaging in normal statistics and that λ thereby tunes a trade-off between accuracy and precision in estimation. Binning also removes potentially misleading within-scale information while preserving information about the shape of a distribution over powers of λ, and we show that some amount of binning can improve sensitivity and specificity of K-S tests without any cost, while more extreme binning tunes a trade-off between sensitivity and specificity. We therefore advocate logarithmic binning as a simple essential step in power-law inference.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Seeing through noise in power laws

Despite widespread claims of power laws across the natural and social sciences, evidence in data is often equivocal. Modern data and statistical methods reject even classic power laws such as Pareto’s law of wealth and the Gutenberg–Richter law for earthquake magnitudes. We show that the maximum-likelihood estimators and Kolmogorov–Smirnov (K-S) statistics in widespread use are unexpectedly sensitive to ubiquitous errors in data such as measurement noise, quantization noise, heaping and censorship of small values. This sensitivity causes spurious rejection of power laws and biases parameter estimates even in arbitrarily large samples, which explains inconsistencies between theory and data. We show that logarithmic binning by powers of λ > 1 attenuates these errors in a manner analogous to noise averaging in normal statistics and that λ thereby tunes a trade-off between accuracy and precision in estimation. Binning also removes potentially misleading within-scale information while preserving information about the shape of a distribution over powers of λ, and we show that some amount of binning can improve sensitivity and specificity of K-S tests without any cost, while more extreme binning tunes a trade-off between sensitivity and specificity. We therefore advocate logarithmic binning as a simple essential step in power-law inference.

97 MATHEMATICS AND COMPUTING↗