Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Characterization of EJ-270 and Ce-doped LiCAF scintillators for the development of high-rate neutron reflectometer detectors

The Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory is anticipated to provide a neutron source with ∼20 times increase in peak brightness than the First Target Station. The neutron reflectometers currently in operation at the First Target Station need to be upgraded due to the increased neutron flux. A prototype neutron detector module based upon a pixelated scintillator array readout by silicon photomultipliers is being developed to address the high-rate challenge faced with future neutron reflectometer instruments at the Second Target Station. Two types of scintillator materials were considered for this detector development, i.e., 6 Li-loaded EJ-270 plastic scintillator and Ce-doped LiCAF single crystal. This paper reports the scintillator characterization results, including light yield, pulse shape discrimination performance, capability to detect thermal neutrons in a high γ-ray field, and γ-ray sensitivity. The number of photons produced per neutron capture by EJ-270 and LiCAF:Ce was measured to be 2176 ± 91 and 2651 ± 108, respectively. EJ-270 demonstrated a good capability to discriminate between neutrons and γ-rays by employing the commonly used charge comparison method (figure-of-merit: 1.13 ± 0.01 for an energy cut of 292–426 keVee) and a reasonable performance when using the time-over-threshold techniques; however, no discrimination was observed from LiCAF:Ce regardless of the pulse shape discrimination approaches utilized, making pulse height discrimination necessary for LiCAF:Ce to differentiate between neutrons and γ-rays. Both EJ-270 and LiCAF:Ce exhibited an acceptable capacity to detect thermal neutrons at high exposure rates up to approximately 584 mR/h. Furthermore, the γ-ray sensitivities measured with a 60 Co source at an exposure rate of around 1145 mR/h were determined to be (6.11 ± 0.87) × 10 −6 and (7.64 ± 1.08) × 10 −7 for EJ-270 and LiCAF:Ce, respectively.

EJ-270↗

Commissioning of the neutron irradiation station at the University of Notre Dame

Cross section data for neutron-induced reactions are needed for applications in nuclear astrophysics, stockpile stewardship, and nuclear reactor design but often contain discrepancies and gaps. A neutron source with a high neutron flux, a well-characterized neutron energy distribution, and a wide range of available neutron energies is ideal for studying such reactions in order to improve on existing data and provide new experimental results. For this purpose, the Neutron Irradiation Station (NIS) was developed using the 7 Li(p,n) 7 Be reaction. Neutron energy profiles were obtained using 3 He spectrometers and neutron standards were used to determine the neutron flux using the activation method. The neutron energy profile was found to be quasi-monoenergetic and neutrons were produced at energies from 1 keV to 1 MeV. Finally, the flux at the production target was found to be (1.42 ± 0.20) x 10 8 s −1 cm −2 .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Conceptual Design of Neutron Sensor Qualification Device

The Advanced Sensors and Instrumentation Program at Idaho National Laboratory has been formulating strategies to qualify sensors for use in nuclear environments, particularly in irradiation experiments and advanced reactors. When qualifying neutron sensors for use in high-temperature environments, the wide range of neutron flux levels and representative energy spectra presents significant challenges. This paper discusses the development of the Neutron Sensor Qualification Device (NQD), which is designed to test neutron sensors in high temperature controlled environments with known neutron spectra, addressing the spatial and spectral complexities of neutron fluxes in reactor cores. The proposed NQD will be situated in the exposure room at the Armed Forces Radiobiology Research Institute, thus affording a unique capability to expose sensors to high neutron and gamma fluxes. To achieve thermal control, the device will utilize a radiation-hardened tube furnace, accommodating multiple sensors and neutron activation dosimetry wires. Titanium, iron, and cobalt dosimeter wires are chosen from the American Society for Testing and Materials and International Reactor Dosimetry and Fusion File libraries as references for providing energy-dependent fluence measurements. The design ensures precise sensor positioning to minimize mutual shielding and flux perturbation, which are evaluated via Monte Carlo N particle Transport Code (MCNP) simulations. These simulations have informed the development of guidelines on sensor placement within the NQD. The NQD is essential to the qualification of neutron sensors for advanced reactor technologies. It enables controlled testing of a statistically significant number of sensors, thereby supporting assessments of sensor performance across various neutron flux levels and temperatures. This paper highlights the detailed planning for the NQD prototype, along with its inaugural irradiation (scheduled for fiscal year [FY] 2025). The results from this initial testing will be fundamental in evaluating the device’s performance and establishing measurement uncertainty for in-pile neutron sensor measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Westcott g factors extended to arbitrary neutron energy spectra

Westcott 𝑔 factors are used in Neutron Activation Analysis (NAA) and Prompt Gamma-ray Activation Analysis (PGAA) to evaluate the impact of non-1∕𝑣 behavior in the neutron-capture cross sections of certain nuclei on activation product yields. This non-1∕𝑣 behavior arises from the presence of neutron resonances in the neutron- capture cross sections that overlap with the source neutron spectrum at low (< 5 eV) energies. Historically, Westcott 𝑔 factors that have been cataloged for NAA and PGAA applications are the result of calculations that assume a Maxwellian neutron flux distribution with a given temperature. In this work, we use this approach with updated neutron-capture cross sections from the Evaluated Nuclear Data File, version VIII.1 (ENDF/B-VIII.1) to tabulate Westcott 𝑔 factor values for a broad range of Maxwellian distribution temperatures, comparing the results against currently-available 𝑔 factors from International Atomic Energy Agency tables and other sources. Here, it was discovered during this analysis that the use of guided thermal and cold-neutron beams at certain facilities necessitates an approach for evaluating Westcott 𝑔 factors based on arbitrary non-Maxwellian spectra. In this paper, we present an approach for calculating 𝑔 factors with user-specified neutron spectra, and we demonstrate these methods to obtain Westcott 𝑔-factors for guided- and cold-neutron beams at the Budapest Research Reactor and the Forschungsreaktor München II reactor. As part of this work, open-source software has been developed that can be used to perform these calculations for applications in PGAA and NAA experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Structural Aspects of Neutron Survival Probabilities

The neutron survival probability (and related quantities including probabilities of extinction and initiation) is a central element of the broader stochastic theory of neutron populations and finds application in fields including reactor start-up, analysis of reactor power bursts and criticality accidents, and safeguards. In a full neutron transport formulation, the equation governing the single-neutron survival probability is a backward or adjoint-like integro-partial differential equation with the added complexity of being highly nonlinear. Analogous formulations of this equation exist in the context of many approximate theories of neutron transport, with the point kinetics formulation having received significant theoretical attention since the 1940s. This work continues this tradition by providing a novel analysis of the single-neutron survival probability equation using the tools of boundary layer theory. The analysis reveals that the “fully dynamic” solution of the single-neutron survival probability equation—and some key probability distributions derived from it—may be cast as a singular perturbation around the underlying quasi-static single-neutron probability of initiation. In this perturbation solution, the expansion parameter is the ratio of the neutron generation time to a macroscopic time scale characterizing the overall system evolution; this interpretation illuminates some of the fundamental structural aspects of neutron survival phenomena.

97 MATHEMATICS AND COMPUTING↗

Statistical and systematic uncertainties in extracting the source properties of neutron star-black hole binaries with gravitational waves

Gravitational waves emitted by neutron star black hole mergers encode key properties of neutron stars - such as their size, maximum mass and spins - and black holes. However, the presence of matter and the high mass ratio makes generating long and accurate waveforms from these systems hard to do with numerical relativity, and not much is known about systematic uncertainties due to waveform modeling. In this work, we simulate gravitational waves from neutron star black hole mergers by hybridizing numerical relativity waveforms produced with the SpEC code with a recent numerical relativity surrogate NRHybSur3dq8Tidal. These signals are analyzed using a range of available waveform families, and statistical and systematic errors are reported. We find that at a network signal-to-noise ratio (SNR) of 30, statistical uncertainties are usually larger than systematic offsets, while at an SNR of 70 the two become comparable. The individual black hole and neutron star masses, as well as the mass ratios, are typically measured very precisely, though not always accurately at high SNR. At a SNR of 30 the neutron star tidal deformability can only be bound from above, while for louder sources it can be measured and constrained away from zero. All neutron stars in our simulations are non-spinning, but in no case we can constrain the neutron star spin to be smaller than ~0.4 (90% credible interval). Waveform families whose late inspiral has been tuned specifically for neutron star black hole signals typically yield the most accurate characterization of the source parameters. Their measurements are in tension with those obtained using waveform families tuned against binary neutron stars, even for mass ratios that could be relevant for both binary neutron stars and neutron star black holes mergers.

79 ASTRONOMY AND ASTROPHYSICS↗

Tomographic Reconstruction of the Neutron Time-Energy Spectrum from a Dense Plasma Focus

A dense plasma focus (DPF) nuclear fusion device is an attractive pulsed neutron source in many applications, due to its relatively large neutron yield, produced in a short time duration. In order to design a DPF that generates neutrons within a specified time profile, or generates a neutron energy spectrum with specific properties, it is necessary to be able to characterize and model the results of the fusion process releasing the neutrons. The time-energy spectrum of fusion neutrons is an ideal quantity to use to validate multiphysics codes that simulate the pinch and fusion processes, because it is a quantity that requires the physics of each of the stages leading up to and ending in the fusion reaction to be simulated correctly. In particular, since DPF fusion neutrons are not monoenergetic -- and there can often be several fusion pinches creating neutrons -- a computer simulation matching high quality neutron spectrum measurements provides great confidence in the fidelity of the simulation. In order to make such a comparison, it is first necessary to have quality measurements from which to infer the spectrum. In this work we pose neutron spectroscopy as the classical tomographic inverse problem from neutron time of flight data at multiple distances, but enhanced by using an additional measurement of the time profile of the fusion pinch near its source and by using detector pairs set up in a geometry that allows for scatter background subtraction. The detector pairs enhance the quality of the time of flight measurements, and the additional constraint posed by the measured time profile allows for reconstructions discretized as finely as the time measurements and in energy as finely as 100 keV, without the problem being underdetermined. We present results from a Deuterium-fueled DPF at the U.S. Department of Energy's Nevada National Security Site and show that we can infer the time-energy spectrum from our measurements for both single and multi-pinch fusion reactions with equal fidelity.

Catenacci, Jared↗

Identification of Final-State Neutrons in ANNIE

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton gadolinium-loaded (Gd-loaded) water Cherenkov detector located on the Booster Neutrino beamline at Fermilab. ANNIE's primary physics objectives include measuring neutron multiplicity for neutrino-nucleus interactions and performing cross-section measurements of charge current quasi-elastic and neutral current quasi-elastic processes. These measurements aim to improve neutrino energy reconstruction and reduce uncertainties in current and future neutrino oscillation experiments. Additionally, ANNIE serves as a testbed for advanced technologies such as Large Area Picosecond Photodetectors (LAPPDs) and Water-Based Liquid Scintillator, which enhance vertex resolution and enable detection below the Cherenkov threshold. By leveraging the high neutron capture cross section of Gd-loaded water, ANNIE is well positioned to observe final-state neutrons in beam-correlated neutrino interactions. To constrain the uncertainties in the neutron capture efficiency and time within the detector, we have conducted multiple calibration campaigns using an AmBe source. The AmBe source is deployed at different locations of the tank to map the neutron capture efficiency and determine the expected neutron capture time. Additionally, the AmBe calibration data are used to define the precise neutron clustering that will be useful for identifying neutron-like clusters from neutrino interaction. In this poster, we will present the current status of the AmBe neutron calibration program and the development of neutron cluster definition for the ANNIE Experiment.

Ajana, Dhavalkumar [Florida State U.]↗

Neutron measurements in space.

The experimental measurements of the neutron flux and energy spectrum in space since 1964 are reviewed and related to the theoretical predictions. A discussion of the neutron sources is presented. The difficulties associated with neutron measurements of both the atmospheric neutron leakage flux and solar neutrons are included. Particular emphasis is placed upon the neutron leakage flux and energy measurements at energies greater than about 1 MeV. The possibilities of CRAND as a source for the energetic trapped protons are discussed in light of recent measurements of the 10- to 100-MeV neutron flux. The current status of the solar neutron flux observations is also presented. An attempt is made to interpret and discuss recent neutron measurements. In order to understand these results, the theoretical predictions of the neutron fluxes and energy spectra from possible neutron sources are briefly presented.

Lockwood, J. A.↗

Preliminary Analysis of the Multisphere Neutron Spectrometer

Crews working on present-day jet aircraft are a large occupationally exposed group with a relatively high average effective dose from galactic cosmic radiation. Crews of future high-speed commercial aircraft flying at higher altitudes would be even more exposed. To help reduce the significant uncertainties in calculations of such exposures, the Atmospheric Ionizing Radiation (AIR) Project, an international collaboration of 15 laboratories, made simultaneous radiation measurements with 14 instruments on five flights of a NASA ER-2 high-altitude aircraft. The primary AIR instrument was a highly sensitive extended-energy multisphere neutron spectrometer with lead and steel shells placed within the moderators of two of its 14 detectors to enhance response at high energies. Detector responses were calculated for neutrons and charged hadrons at energies up to 100 GeV using MCNPX. Neutron spectra were unfolded from the measured count rates using the new MAXED code. We have measured the cosmic-ray neutron spectrum (thermal to greater than 10 GeV), total neutron fluence rate, and neutron effective dose and dose equivalent rates and their dependence on altitude and geomagnetic cutoff. The measured cosmic-ray neutron spectra have almost no thermal neutrons, a large "evaporation" peak near 1 MeV and a second broad peak near 100 MeV which contributes about 69% of the neutron effective dose. At high altitude, geomagnetic latitude has very little effect on the shape of the spectrum, but it is the dominant variable affecting neutron fluence rate, which was 8 times higher at the northernmost measurement location than it was at the southernmost. The shape of the spectrum varied only slightly with altitude from 21 km down to 12 km (56 - 201 grams per square centimeter atmospheric depth), but was significantly different on the ground. In all cases, ambient dose equivalent was greater than effective dose for cosmic-ray neutrons.

Goldhagen, P.↗

Computational Transport Modeling of High-Energy Neutrons Found in the Space Environment

The high charge and high energy (HZE) particle radiation environment in space interacts with spacecraft materials and the human body to create a population of neutrons encompassing a broad kinetic energy spectrum. As an HZE ion penetrates matter, there is an increasing chance of fragmentation as penetration depth increases. When an ion fragments, secondary neutrons are released with velocities up to that of the primary ion, giving some neutrons very long penetration ranges. These secondary neutrons have a high relative biological effectiveness, are difficult to effectively shield, and can cause more biological damage than the primary ions in some scenarios. Ground-based irradiation experiments that simulate the space radiation environment must account for this spectrum of neutrons. Using the Particle and Heavy Ion Transport Code System (PHITS), it is possible to simulate a neutron environment that is characteristic of that found in spaceflight. Considering neutron dosimetry, the focus lies on the broad spectrum of recoil protons that are produced in biological targets. In a biological target, dose at a certain penetration depth is primarily dependent upon recoil proton tracks. The PHITS code can be used to simulate a broad-energy neutron spectrum traversing biological targets, and it account for the recoil particle population. This project focuses on modeling a neutron beamline irradiation scenario for determining dose at increasing depth in water targets. Energy-deposition events and particle fluence can be simulated by establishing cross-sectional scoring routines at different depths in a target. This type of model is useful for correlating theoretical data with actual beamline radiobiology experiments. Other work exposed human fibroblast cells to a high-energy neutron source to study micronuclei induction in cells at increasing depth behind water shielding. Those findings provide supporting data describing dose vs. depth across a water-equivalent medium. This poster presents PHITS data suggesting an increase in dose, up to roughly 10 cm depth, followed by a continual decrease as neutrons come to a stop in the target.

Cox, Brad↗

Precise Measurement of the Neutron Skin Thicknesses of 208Pb and 48Ca

Despite great leaps of development in nuclear physics over the past century, we still do not have a comprehensive understanding of nuclear structure. This is mainly due to the lack of precise knowledge of the neutron distribution inside nucleus. Electromagnetic probes are ineffective in probing neutrons, unlike their charged partners, the protons. Therefore, it is of great importance to constrain the neutron distributions experimentally. Heavy nuclei have more neutrons than protons in order to balance the repulsion between protons. In such neutron-rich nuclei, the extra neutrons are pushed out to the surface by the nuclear symmetry energy, forming the so-called ?neutron skin?. The neutron skin can be probed with a well-established experimental technique ? parity-violating electron scattering (PVES). Using the scattering of longitudinally polarized electrons by an unpolarized target, PREX-II and CREX measure the small parity-violating asymmetry in cross sections. Employing electrons with opposite helicities the weak form factor, the neutron distribution and the neutron skin thickness of the target nucleus are extracted. With excellent beam qualities and dedicated instrumentation at Jefferson Lab, the asymmetry measurements are statistics-limited. We report the results of these two high-precision measurements and their implications on broad topics, from the nuclear structures to the neutron stars.

Zhang, Weibin↗

A scalable transformer model for real-time decision making in neutron scattering experiments

The U.S. Department of Energy's (DOE's) neutron research facilities at Oak Ridge National Laboratory (ORNL), including the High Flux Isotope Reactor (HFIR) and the Spallation Neutron Source (SNS), are a state-of-the-art neutron scattering facility that allows researchers to study the structure and dynamics of materials at the atomic scale. At the SNS, neutrons are measured using the time-of-flight (TOF) technique as they move through a neutron beamline to interact with a sample. Large volumes of neutron scattering data are collected and recorded in neutron event mode. Optimal productivity of the TOF instrument is limited due to the lack of real-time data analysis tools. The large amount of data generated by the experiments can be challenging to process and analyze in real time, particularly for experiments that require rapid feedback and adjustment of experimental parameters. The regular computer/workstation cannot keep up with the experiment speed to provide real-time feedback to adjust experimental parameters, so connecting the supercomputers available to the neutron facility is necessary to achieve real-time data analysis and experiment steering. To address this challenge, we exploit the Frontier supercomputer at Oak Ridge Leadership Computing Facility (OLCF) to train a scalable temporal fusion transformer model for real-time decision making of TOF neutron scattering experimentation. Here, in this paper, we present the results using Frontier to provide the processing power needed to rapidly process and analyze large volumes of single-crystal diffraction data collected at TOPAZ, a neutron time-of-flight Laue single-crystal diffractometer at the SNS.

97 MATHEMATICS AND COMPUTING↗

Analysis of SPND Material Candidates for Real-Time Neutron Spectrum Monitoring Poster

The future of the nuclear industry will be shaped by advanced reactor designs requiring innovative instrumentation for safe operation. A key area of innovation is the ability to accurately and reliably monitor the neutron energy spectrum during operations, which would also enhance the experimental capabilities of existing research reactors. To address this need, our research focuses on the potential use of Self-Powered Neutron Detectors (SPNDs) for real-time neutron spectrum monitoring. We investigated various candidate materials for SPNDs by evaluating their energy-dependent reaction rates. Promising materials were further modeled using MCNP to determine the free electron production per neutron across the neutron energy spectrum, approximating their energy-dependent signal sensitivity. Our findings identified Samarium (Sm) and Gadolinium (Gd) as top candidates for thermal neutrons, Hafnium (Hf) and Thulium (Tm) for epithermal neutrons, and Tantalum (Ta) for fast neutrons. These materials will undergo future experimental validation to confirm the modeled responses and assess their feasibility for real-time neutron spectrum measurements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

A modular apparatus for use in high-precision measurements of parity violation in polarized eV neutron transmission

We describe a modular apparatus for use in parity-violation measurements in epithermal neutron–nucleus resonances with high instantaneous neutron fluxes at the Manuel Lujan Jr. Neutron Scattering Center at Los Alamos National Laboratory. This apparatus is designed to conduct high-precision measurements of the parity-odd transmission asymmetry of longitudinally polarized neutrons through targets containing nuclei with p-wave neutron–nucleus resonances in the 0.1–10 eV energy regime and to accommodate a future search for time reversal violation in polarized neutron transmission through polarized nuclear targets. The apparatus consists of an adjustable neutron and gamma collimation system, a 3 He- 4 He ion chamber neutron flux monitor, two identical cryostats for target cooling, an adiabatic eV-neutron spin flipper, a near-unit efficiency 6 Li- 7 Li scintillation detector operated in current mode, a flexible CAEN data acquisition system, and a neutron spin filter based on spin-exchange optical pumping of 3 He gas. We describe the features of the apparatus design devoted to the suppression of systematic errors in parity-odd asymmetry measurements. We describe the configuration of the apparatus used to conduct a precision measurement of parity violation at the 0.7 eV p-wave resonance in 139 La which employs two identical 139 La targets, one to polarize the beam on the p-wave resonance using the weak interaction and one to analyze the polarization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of a positron-emission-tomography-based SiPM readout for compact segmented neutron imagers

Gamma-ray emission from special nuclear material (SNM) is relatively easy to shield from detection using modest amounts of high-Z material. In contrast, fast-neutrons are much more penetrating and can escape relatively thick high-Z shielding without losing significant energy. Furthermore, fast neutrons provide a clear and unambiguous signature of the presence of SNM with few competing natural background sources. The challenge of detecting fast neutrons is twofold. First, the neutron flux from SNM are only a fraction of the corresponding gamma-ray flux. Second, fast neutrons can be difficult to differentiate from gamma rays. The ability to discriminate gamma rays from neutrons, combined with a neutron imaging capability, can in some situations enable the localization of SNM neutron sources distinct from background. With the developments of pulse-shape-sensitive plastic scintillators that offer excellent gamma-ray/neutron discrimination, and arrays of silicon photomultipliers combined with highly scalable and fast positron-emission-tomography (PET) multi-channel readout systems, field-deployable neutron imagers suitable for SNM detection might now be within reach. In this paper, we present a characterization of the performance of a recently available commercial PET-scanner readout, including its sensitivity to pulse-shape differences between fast neutrons and gamma rays, energy and timing resolution. Here, we find that, while the pulse-shape discrimination is achievable with stilbene, further improvement of the readout is required to achieve it with the PSD-capable available plastic scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High average-flux laser-driven neutron source

Laser-driven neutron generation is an attractive alternative to more established methods for compact, short-pulse-duration neutron sources with applications in medical science, material science and imaging. Despite extensive investigation of various techniques, achieving performance comparable to nuclear reactors or conventional accelerators remains challenging. In this work, we generate a stable, high-repetition-rate laser-driven neutron source reaching a record average flux of 7.8 × 10 7 n/sr/s, improving on other existing laser-based sources by more than one order of magnitude. Our approach is based on a two-step process where electrons are accelerated to relativistic energies via laser wakefield acceleration (LWFA), and subsequently generate neutrons through Bremsstrahlung emission followed by photonuclear reactions in a tungsten converter. Experimental results, supported by Monte Carlo simulations, show a neutron flux of 3.0 × 10 7 n/cm 2 /s near the target, on par with some compact accelerator-based neutron sources. Additionally, a direct comparison with the target-normal sheath acceleration (TNSA) pitcher-catcher scheme, performed on the same laser system, reveals a significantly higher total neutron yield of 3.9 × 10 8 neutrons per shot, outperforming the TNSA scheme by several orders of magnitude. These findings represent a significant advancement towards the development of practical laser-driven neutron sources and highlight the advantages of LWFA-based neutron generation for future applications.

Vallières, Simon [Institut National de la Recherch↗

Design of an epithermal neutron velocity selection system for the Penn State Breazeale Reactor

A series of mechanical neutron choppers to operate as a velocity selection system have been developed for the Pennsylvania State Breazeal Reactor (PSBR). This chopper system will provide pulsed epithermal neutrons in the energy range of 0.5–40 eV with 2% or better energy resolution, and with a transmission of 1E-6 or better. Four different chopper geometries have been evaluated for their utility as mechanical neutron choppers. Specifically, Fermi, ring, piston, and disc choppers have been evaluated to assess their potential neutronics performance and mechanical constructability. A series of high-speed disc choppers were selected for the final design, and optimization work was performed to maximize the neutron pulse intensity. It is estimated that the optimized system will produce an epithermal neutron intensity of approximately 96 n/s. This system can also be operated in a time of flight (TOF) configuration such that the neutrons arriving at the source have a white spectrum. This operation can be accomplished by leaving the second stage of choppers in the open position, or by removing it from the beam completely. Such unique source of epithermal neutrons produced by this chopper system will have applications in both prompt and delayed epithermal neutron activation analysis (ENAA), as well as in neutron resonance transmission analysis (NRTA).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗