Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NECK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Viking configuration pitch damping derivatives as influenced by support interference and test technique at transonic and supersonic speeds.

Experimental studies to determine the 140-deg spherically-blunted cone configuration single degree-of-freedom damping derivative included model sting interference effects at M = 1.76 to 3.0. Minimal sting influences are noted with sting/model diameter ratios of 0.183 and effective sting lengths of 3.55 of the reference length. Increasing the ratio of sting diameter to reference length to 0.53 influences damping considerably at angles of attack from 0 to 3 deg at all Reynolds numbers but shows little or no effect at higher angles. Free-flight model wake geometries (wake neck position and size) correlate well with those from captive model tests with the small diameter sting; this adds confidence to obtaining damping derivatives through captive model testing. The damping characteristics of an early Viking configuration obtained on 11.23 and 4.35% scale models using forced and free oscillation test methods, respectively, in two different test facilities are compared. The agreement is quite good under test conditions.

Steinberg, S.↗

Noninvasive measurement of central venous pressure

A technique for the noninvasive measurement of CVP in man was developed. The method involves monitoring venous velocity at a point in the periphery with a transcutaneous Doppler ultrasonic velocity meter while the patient performs a forced expiratory maneuver. The idea is the CVP is related to the value of pressure measured at the mouth which just stops the flow in the vein. Two improvements were made over the original procedure. First, the site of venous velocity measurement was shifted from a vein at the antecubital fossa (elbow) to the right external jugular vein in the neck. This allows for sensing more readily events occurring in the central veins. Secondly, and perhaps most significantly, a procedure for obtaining a curve of relative mean venous velocity vs mouth pressure was developed.

Webster, J. G.↗

A study of the thermoregulatory characteristics of a liquid-cooled garment with automatic temperature control based on sweat rate: Experimental investigation and biothermal man-model development

Experimental results for three subjects walking on a treadmill at exercise rates of up to 590 watts showed that thermal comfort could be maintained in a liquid cooled garment by using an automatic temperature controller based on sweat rate. The addition of head- and neck-cooling to an Apollo type liquid cooled garment increased its effectiveness and resulted in greater subjective comfort. The biothermal model of man developed in the second portion of the study utilized heat rates and exchange coefficients based on the experimental data, and included the cooling provisions of a liquid-cooled garment with automatic temperature control based on sweat rate. Simulation results were good approximations of the experimental results.

Chambers, A. B.↗

Adjustment of saccade characteristics during head movements.

Saccade characteristics have been studied during coordinated eye-head movements in monkeys. Amplitude, duration, and peak velocity of saccades with head turning were compared with saccades executed while the head was artificially restrained. The results indicate that the saccade characteristics are modulated as a function of head movement, hence the gaze movement (eye+head) exactly matches saccades with head fixed. Saccade modulation is achieved by way of negative vestibulo-ocular feedback. The neck proprioceptors, because of their longer latency, are effective only if the head starts moving prior to the onset of saccade. It is concluded that saccades make with head turning are not 'ballistic' movements because their trajectory is not entirely predetermined by a central command.

Morasso, P.↗

Dislocation generation during early stage sintering.

Discussion of the effects of capillarity-induced stresses on dislocations during early stage sintering. A special version of Hirth's (1963) theoretical calculation procedures modified to describe dislocation nucleation on planes meeting the sintering body's neck surface obliquely is shown to predict plastic flow at stress levels know to exist between micron size metal particles in the early stages of sintering.

Sheehan, J. E.↗

Mechanical coupling for high cyclic loading

One-piece cylindrical coupling with ""necked-down'' regions at each end form flexures allowing small misalignments between actuator and load. Coupling has zero backlash, low mass, close spacing between actuator and load, high stiffness in direction of motion, and allowance for misalignments and deflections without causing high side loading on components.

Dustin, M. O.↗

Property investigation and sputter deposition of dispersion-hardened copper for fatigue specimen fabrication

Sputter-deposited alloys of dispersion-hardenable Cu-0.25 vol% SiC and Cu-0.50 vol% SiC and precipitation-hardenable Cu-0.15 wt% Zr and Cu-0.05 wt% Mg-0.15 wt% Zr-0.40 wt% Cr were investigated for selection to evaluate fatigue specimen performance with potential application in fabricating regeneratively cooled rocket thrust chambers. Yield strengths in the 700 to 1000-MN/sq m range were observed with uniform elongation ranging from 0.5 to 1.5% and necking indicative of greater ductility. Electrical conductivity measured as an analog to thermal conductivity gave values 90% IACS for Cu-0.15 wt% Zr and Cu-0.05 wt% Mg-0.15 wt% Zr-0.40 wt% Cr. A 5500-g sputtered deposit of Cu-0.15 wt% Zr alloy, 12.29 mm (0.484 in.) average thickness in the fatigue specimen gage length, was provided to NASA on one of their substrates.

Mcclanahan, E. D.↗

Finite element formulations for problems of large elastic-plastic deformation

An Eulerian finite element formulation is presented for problems of large elastic-plastic flow. The method is based on Hill's variational principle for incremental deformations, and is suited to isotropically hardening Prandtl-Reuss materials. The formulation is given in a manner which allows any conventional finite element program, for "small strain" elasticplastic analysis, to be simply and rigorously adapted to problems involving arbitrary amounts of deformation and arbitrary levels of stress in comparison to plastic deformation moduli. The method is applied to a necking bifurcation analysis of a bar in plane-strain tension. A unified general formulation of finite element equations, both Lagrangian and Eulerian, for large deformations, with arbitrary choice of the conjugate stress and strain measures, and a discussion is given of other proposed formulations for elastic-plastic finite element analysis at large strain.

Mcmeeking, R. M.↗

Cyclic deformation at a crack tip and its correlation with fatigue crack propagation

Results of measurements of fatigue crack growth and the cyclic surface strains near crack tips in 2024-T351 aluminum alloy for two plate thicknesses and two stress ratios. It is shown that crack tip necking complicates cyclic deformation. In this case, crack growth rate not only reflects the material property, but is also affected by specimen geometry. It is concluded that for general material evaluation it is more desirable to use a specimen thick enough so that the condition of plane strain prevails.

Kang, T. S.↗

Applications of the direct photon absorption technique for measuring bone mineral content in vivo. Determination of body composition in vivo

The bone mineral content, BMC, determined by monoenergetic photon absorption technique, of 29 different locations on the long bones and vertebral columns of 24 skeletons was measured. Compressive tests were made on bone from these locations in which the maximum load and maximum stress were measured. Also the ultimate strain, modulus of elasticity and energy absorbed to failure were determined for compact bone from the femoral diaphysis and cancellous bone from the eighth through eleventh thoracic vertebrae. Correlations and predictive relationships between these parameters were examined to investigate the applicability of using the BMC at sites normally measured in vivo, i.e. radius and ulna in estimating the BMC and/or strength of the spine or femoral neck. It was found that the BMC at sites on the same bone were highly correlated r = 0.95 or better; the BMC at sites on different bones were also highly interrelated, r = 0.85. The BMC at various sites on the long bones could be estimated to between 10 and 15 per cent from the BMC of sites on the radius or ulna.

Cameron, J. R.↗

Depth of immersion as a determinant of the natriuresis of water immersion

The current study was undertaken to further assess the contribution of an immersion-induced hydrostatic pressure gradient on the redistribution of blood volume. The rate of sodium excretion by seated subjects was significantly increased by water immersion up to the chest and neck compared to waist immersion and controls. These results are consistent with the hypothesis that whereas immersion to the level of the diaphragm merely cancels the intravascular hydrostatic pressure gradient by providing an identical external gradient, immersion above the diaphragm level results in increased water pressure which tends to favor a shift in blood volume from the lower extremities.

Epstein, M.↗

Finite-element formulations for problems of large elastic-plastic deformation

An Eulerian finite element formulation is presented for problems of large elastic-plastic flow. The method is based on Hill's variational principle for incremental deformations, and is ideally suited to isotropically hardening Prandtl-Reuss materials. Further, the formulation is given in a manner which allows any conventional finite element program, for 'small strain' elastic-plastic analysis, to be simply and rigorously adapted to problems involving arbitrary amounts of deformation and arbitrary levels of stress in comparison to plastic deformation moduli. The method is applied to a necking bifurcation analysis of a bar in plane-strain tension. The paper closes with a unified general formulation of finite element equations, both Lagrangian and Eulerian, for large deformations, with arbitrary choice of the conjugate stress and strain measures. Further, a discussion is given of other proposed formulations for elastic-plastic finite element analysis at large strain, and the inadequacies of some of these are commented upon.

Mcmeeking, R. M.↗

Biothermal simulation of scuba divers

A biothermal model of the immersed man is presented and validated. Comparisons are made between analytic and experimental values of temperature-vs-time profiles for neck-immersed seminude and wet-suited subjects. An engineering example is presented to demonstrate how the model may be used to evaluate proposed life-support system designs.

Montgomery, L. D.↗

Effects of water immersion on renal hemodynamics in normal man

The present study was undertaken to delineate the effects of water immersion to the neck (NI) on renal plasma flow and glomerular filtration rate as assessed by the clearance of p-aminohippuric acid (PAH) and inulin, respectively. Nine normal male subjects were studied on two occasions, control and NI. The conditions of seated posture and time of day were identical. Immersion did not alter either clearance at a time when sodium excretion was increasing markedly. The constancy of PAH clearance during NI suggests that renal blood flow is unaltered and that the natriuresis of NI is mediated independently of alterations in overall renal perfusion. The sluggish decline of a natriuresis during recovery is consistent with the presence of a humoral factor contributing to the encountered natriuresis.

Epstein, M.↗

Helmet latching and attaching ring

A neck ring releasably secured to a pressurized garment carries an open-ended ring normally in the engagement position fitted into an annular groove and adapted to fit into a complementary annular groove formed in a helmet. Camming means formed on the inner surface at the end of the helmet engages the open-ended ring to retract the same and allow for one motion donning even when the garment is pressurized. A projection on the end of the split ring is engageable to physically retract the split ring.

Chase, E. W.↗

Influence of central venous pressure upon sinus node responses to arterial baroreflex stimulation in man

Measurements were made of sinus node responses to arterial baroreceptor stimulation with phenylephrine injection or neck suction, before and during changes of central venous pressure provoked by lower body negative pressure or leg and lower truck elevation. Variations of central venous pressure between 1.1 and 9.0 mm Hg did not influence arterial baroreflex mediated bradycardia. Baroreflex sinus node responses were augmented by intravenous propranolol, but the level of responses after propranolol was comparable during the control state, lower body negative pressure, and leg and trunk elevation. Sinus node responses to very brief baroreceptor stimuli applied during the transitions of central venous pressure also were comparable in the three states. The authors conclude that physiological variations of central venous pressure do not influence sinus node responses to arterial baroreceptor stimulation in man.

Mark, A. L.↗

Hypervelocity gun

A velocity amplifier system which uses both electric and chemical energy for projectile propulsion is provided in a compact hypervelocity gun suitable for laboratory use. A relatively heavy layer of a tamping material such as concrete encloses a loop of an electrically conductive material. An explosive charge at least partially surrounding the loop is adapted to collapse the loop upon detonation of the charge. A source of electricity charges the loop through two leads, and an electric switch which is activated by the charge explosive charge, disconnects the leads from the source of electricity and short circuits them. An opening in the tamping material extends to the loop and forms a barrel. The loop, necked down in the opening, forms the sabot on which the projectile is located. When the loop is electrically charged and the explosive detonated, the loop is short circuited and collapsed thus building up a magnetic field which acts as a sabot catcher. The sabot is detached from the loop and the sabot and projectile are accelerated to hypervelocity.

Ford, F. C.↗

Optokinetic motion sickness - Attenuation of visually-induced apparent self-rotation by passive head movements

An experimental study was conducted on seven normal subjects to evaluate the effectiveness of passive head movements in suppressing the optokinetically-induced illusory self-rotation. Visual simulation was provided by a servo-controlled optokinetic drum. Each subject participated in two experimental sessions. In one condition, the subject's head remained stationary while he gazed passively at a moving stripe pattern. In the other, he gazed passively and relaxed his neck muscles while his head was rotated from side to side. It appears that suppression of optokinetically-induced illusory self-rotation with passive head movements results from the operation of a spatial constancy mechanism interrelating visual, vestibular, and kinesthetic information on ongoing body orientation. The results support the view that optokinetic 'motion sickness' is related, at least in part, to an oculomotor disturbance rather than a visually triggered disturbance of specifically vestibular etiology.

Teixeira, R. A.↗