Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Motion Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A System for Measuring the Sway of the Vehicle Assembly Building

A system was developed to measure the sway of the Vehicle Assembly Building (VAB) at Kennedy Space Center. This system was installed in the VAB and gathered more than one total year of data. The building movement was correlated with measurements provided by three wind towers in order to determine the maximum deflection of the building during high-wind events. The VAB owners were in the process of obtaining new platforms for use in assembling very tall rockets when analysis of the VAB showed that a high wind could move the building sufficiently that an upper platform might impact a rocket. The problem arises because safety requires a relatively small gap between the platform and the rocket, while a large enough gap is needed to ensure that stacking tolerances prevent contact between the rocket and the platform. This only leaves an inch or two (approximately 2 to 5 cm) of total clearance, so when the analysis showed that more than a couple of inches of motion could occur in a high wind, there was a potential for damaging the rocket. The KSC Applied Physics Laboratory was asked to install a system in the VAB that could measure the motion of the building in high winds to determine the actual building sway. The motion of the VAB roof under wind load was measured optically, and under analysis, it was determined that a relatively large-aperture optical system would be required to reduce diffraction effects to less than a small fraction of an inch (approximately mm) at a distance of 500 ft (≈150 m). A 10-in. (approximately 250 mm) telescope was placed on the floor of the building, looking at the ceiling. On the ceiling, a flat plate with three white LEDs was mounted in an "L" shape, such that the telescope was essentially looking at three stars. Software was written to track the motion of these three points using an image processing system. This provided a better than 1/10-in. (approximately 2.5-mm) 2D measurement faster than once a second. Data was downloaded once a month for comparison with the wind tower data. The system was fully operational and provided enough data to show that the VAB will only move 1 in. (approximately 2.5 cm) at the ceiling under 70-knot winds. Adjustable platforms are not required.

Youngquist, Robert↗

TH-CD-207A-09: Stay On Target: Dynamic, Patient-Specific Templates of Fiducial Marker Clusters for IGRT

Purpose: Pancreatic SBRT relies on extremely accurate delivery of ablative radiation doses to the target, and intra-fractional tracking of fiducial markers can facilitate improvements in dose delivery. However, this requires algorithms that are able to find fiducial markers with high speed and accuracy. The purpose of this study was to develop a novel marker tracking algorithm that is robust against many of the common errors seen with traditional template matching techniques. Methods: Using CBCT projection images, a method was developed to create detailed template images of fiducial marker clusters without prior knowledge of the number of markers, their positions, or their orientations. Briefly, the method (i) enhances markers in projection images, (ii) stabilizes the cluster’s position, (iii) reconstructs the cluster in 3D, and (iv) precomputes a set of static template images dependent on gantry angle. Furthermore, breathing data were used to produce 4D reconstructions of clusters, yielding dynamic template images dependent on gantry angle and breathing amplitude. To test these two approaches, static and dynamic templates were used to track the motion of marker clusters in more than 66,000 projection images from 75 CBCT scans of 15 pancreatic SBRT patients. Results: For both static and dynamic templates, the new technique was able to locate marker clusters present in projection images 100% of the time. The algorithm was also able to correctly locate markers in several instances where only some of the markers were visible due to insufficient field-of-view. In cases where clusters exhibited deformation and/or rotation during breathing, dynamic templates resulted in cross-correlation scores up to 70% higher than static templates. Conclusion: Patient-specific templates provided complete tracking of fiducial marker clusters in CBCT scans, and dynamic templates helped to provide higher cross-correlation scores for deforming/rotating clusters. This novel algorithm provides an extremely accurate method to detect fiducial markers during treatment. Research funding provided by Varian Medical Systems to Miften and Jones.

60 APPLIED LIFE SCIENCES↗

OBSERVATIONAL EVIDENCE OF PARTICLE ACCELERATION ASSOCIATED WITH PLASMOID MOTIONS

We report a strong association between the particle acceleration and plasma motions found in the 2010 August 18 solar flare. The plasma motions are tracked in the extreme ultraviolet (EUV) images taken by the Atmospheric Imaging Assembly (AIA) on board the Solar Dynamics Observatory and the Extreme UltraViolet Imager (EUVI) on the Solar Terrestrial Relations Observatory spacecraft Ahead , and the signature of particle acceleration was investigated by using Nobeyama Radioheliograph data. In our previous paper, we reported that in EUV images many plasma blobs appeared in the current sheet above the flare arcade. They were ejected bidirectionally along the current sheet, and the blobs that were ejected sunward collided with the flare arcade. Some of them collided or merged with each other before they were ejected from the current sheet. We discovered impulsive radio bursts associated with such plasma motions (ejection, coalescence, and collision with the post flare loops). The radio bursts are considered to be the gyrosynchrotron radiation by nonthermal high energy electrons. In addition, the stereoscopic observation by AIA and EUVI suggests that plasma blobs had a three-dimensionally elongated structure. We consider that the plasma blobs were three-dimensional plasmoids (i.e., flux ropes) moving in a current sheet. We believe that our observation provides clear evidence of particle acceleration associated with the plasmoid motions. We discuss possible acceleration mechanisms on the basis of our results.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetohydrodynamics and Heat Transfer in a Free-Surface, Flowing Liquid Metal Experiment

This thesis examines magnetohydrodynamic (MHD) effects and heat transfer in free-surface, liquid metal flow. The interaction of the flow with the applied magnetic field introduces an anisotropy to the fluid motion, resulting in starkly different behavior depending on the orientation and strength of the applied magnetic field. The transition from a hydrodynamic state to an MHD state was experimentally found to be characterized by the interaction parameter, N = &sigma L B 2 /&rho v0 , crossing above 0.5. The experiment consisted of a channel 1 m in length, up to 16 cm in width and 1 to 2.5 cm in depth situated within an electromagnet capable of producing a uniform magnetic field up to 2.7 kG. The fluid velocity was measured with an array of 25 potential probes that resolved the spanwise velocity profile, while waves on the surface of the metal were monitored via a diagnostic that tracked the motion of a laser beam reflected off of the free surface. Lastly, the temperature response of the fluid was recorded with an array of 32 thermocouples embedded in the bottom of the channel and a mid-wavelength infrared camera used to image the free surface. Three distinct sets of experiments were performed to investigate the effects of the applied magnetic field on the dynamics within the flow, studying: 1) changes to vortices in the wake of a cylinder, 2) behavior of surface fluctuations due to the turbulent flow, and 3) vertical heat transfer resulting from heat deposition on the free surface. The first set of experiments examined the wake of a cylinder inserted into the flow with its axis parallel to the magnetic field. Measurements with the potential probes indicated that vortices in the wake became laminarized as the field was increased due to the alignment of the injected vorticity with the applied field. The second set of experiments showed that surface fluctuations were suppressed at high magnetic fields, but the precise nature of the damping depended on the orientation of the applied field. Lastly, when heat was injected at the free surface via a resistive heater, the temperature response of the fluid was found to vary considerably depending on the strength and direction of the applied field. In all experiments, it was observed that the angle between the vorticity of structures in the flow and the applied magnetic field dictated the macroscopic behavior of the fluid. This work provides the first experimental results of several phenomena associated with free-surface, liquid metal flows in an applied magnetic field. Further, the results have direct implications for proposed flowing liquid metal divertors for fusion reactors, and offer insight into the nature of turbulent MHD flows.

fusion↗

SU-E-T-183: Clinical Quality Assurance Workflow for Dynamic Tumor Tracking Radiation Dose Delivery

Purpose: One of the most important aspects of implementation of new treatment modalities is an ‘end-to-end’ verification of the treatment process. Radiation treatment based on dynamic tracking of a tumor is highly patient-specific, therefore, special attention should be paid to quality assurance of the treatment delivery. Our goal was to design the clinical workflow that ensures accurate delivery of the planned dose using the Dynamic Target Tracking option of VeroTM (BrainLab,MHI) linac. Methods: A patient simulation is designed to include a pre-treatment session to verify whether the system can reliably track the motion of the implanted marker and build the 4D model of the target motion. The external surrogate and target motion patterns are recorded in the ExactracTM log files. In this work, a spectrum of custom marker and external surrogate motion trajectories closely resembling the patient specific motion patterns was used. 1mm thick/11mm long VisicoilTM marker was placed 15 and 20mm from the center of the spherical tissue equivalent target (centroid to centroid distance) in the 4D motion phantom (CIRSTM). 3D conformal (3 mm block margin) SBRT plans were delivered to 2 moving targets in the phantom: 1) 20mm diameter target that allows ion chamber dose measurement and 2) 25mm target that allows using film to measure CAX dose (GafchromicTM EBT3 used). The measured dose was compared to the iPlanTM TPS results using MonteCarlo algorithm (1% variance, Dose-to-water). Results: On average, film shows 98.9% pass using gamma criterion for 2% and 2mm DTA, 94.3% match for 2% and 1 mm DTA, 98% pass for 1% and 2 mm DTA however only 88% points passing for 1% and 1 mm DTA. Ion chamber measurements agreed with the calculation within 1.5%. Conclusion: The clinical QA workflow was designed for SBRT delivery using real-time tumor tracking on VeroTM linac.

60 APPLIED LIFE SCIENCES↗

Optimum value of original events on the PEPT technique

Do Positron emission particle tracking (PEPT) has been used to track the motion of a single radioactively labeled tracer particle within a bed of similar particles. In this paper, the effect of the original event fraction on the results precise in two experiments has been reviewed. Results showed that the algorithm can no longer distinguish some corrupt trajectories, in addition to; further iteration reduces the statistical significance of the sample without improving its quality. Results show that the optimum value of trajectories depends on the type of experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

European sea bass show behavioural resilience to near-future ocean acidification

Ocean acidification (OA)-caused by rising concentrations of carbon dioxide (CO 2 )-is thought to be a major threat to marine ecosystems and has been shown to induce behavioural alterations in fish. Here we show behavioural resilience to near-future OA in a commercially important and migratory marine finfish, the Sea bass (Dicentrarchus labrax). Sea bass were raised from eggs at 19 °C in ambient or near-future OA (1000 μatm pCO 2 ) conditions and n = 270 fish were observed 59-68 days post-hatch using automated tracking from video. Fish reared under ambient conditions, OA conditions, and fish reared in ambient conditions but tested in OA water showed statistically similar movement patterns, and reacted to their environment and interacted with each other in comparable ways. Thus our findings indicate behavioural resilience to near-future OA in juvenile sea bass. Moreover, simulated agent-based models indicate that our analysis methods are sensitive to subtle changes in fish behaviour. Lastly, it is now important to determine whether the absences of any differences persist under more ecologically relevant circumstances and in contexts which have a more direct bearing on individual fitness.

54 ENVIRONMENTAL SCIENCES↗

Gigatraj: An Atmospheric Trajectory Model

Atmospheric trajectory models have a long history of success in tracking air motions in the lower stratosphere and upper troposphere over periods of up to a few days. Parcels have been traced backwards from observations to identify whatever phenomena (strong convection, volcanic eruptions, rocket launches, etc.) put their signature on them. Parcels have also been initialized at a known event and traced forward to examine their subsequent physical and chemical evolution. We describe a new trajectory model, "gigatraj," that aims to increase exibility by (a) making it straightforward to use new meteorological data sources, including those not based on regular latitude-longitude grids; (b) enabling a run-time choice of vertical coordinate system for kinematic and/or quasi-isentropic calculations; (c) allowing for the output of arbitrary meteorological products, selectable by the user and interpolated to the parcels' locations and times. The model can be run in a serial or parallel processing environment, so that large numbers of parcels can be traced in a reasonable time. Information is presented on model accuracy and performance. The former is demonstrated by runs using both test-pattern winds (comparing expected paths with actual output) and real-world winds (comparing forward and backward runs to characterize how well parcels retrace their paths). Sample cases are also shown, including a reverse domain lling (RDF) calculation illustrating a tropopause fold event. Model output can be displayed using the new Visualization And Lagrangian dynamics Immersive eXtended Reality (VALIXR) system, and an example will be shown. In addition, we describe work to incorporate a version of gigatraj into the Goddard Earth Observing System (GEOS) of NASA's Global Modeling and Assimilation O ce (GMAO) at Goddard Space Flight Center. This enables trajectory calculations to be performed within the running GEOS model at the latter's native time resolution, instead of using the winds from every few hours. It also provides access to all of GEOS's internal variables as they are calculated. This module may be useful, for example, for tracking rapid chemical changes in a Lagrangian framework.

dynamics↗

TU-H-CAMPUS-TeP2-01: A Comparison of Noninvasive Techniques to Assess Radiation-Induced Lung Damage in Mice

Purpose: To evaluate the use of post-irradiation changes in respiratory rate and CBCT-based morphology as predictors of survival in mice. Methods: C57L/J mice underwent whole-thorax irradiation with a Co-60 beam to four different doses [0Gy (n=3), 9Gy (n=5), 11Gy (n=7), and 13Gy (n=5)] in order to induce varying levels of pneumonitis. Respiratory rate measurements, breath-hold CBCTs, and free-breathing CBCTs were acquired pre-irradiation and at six time points between two and seven months post-irradiation. For respiratory rate measurements, we developed a novel computer-vision-based technique. We recorded mice sleeping in standard laboratory cages with a 30 fps, 1080p webcam (Logitech C920). We calculated respiratory rate using corner detection and optical flow to track cyclical motion in the fur in the recorded video. Breath-hold and free-breathing CBCTs were acquired on the X-RAD225Cx system. For breathhold imaging, the mice were intubated and their breath was held at full-inhale for 20 seconds. Healthy lung tissue was delineated in the scans using auto-threshold contouring (0–0.7 g/cm{sup 3}). The volume of healthy lung was measured in each of the scans. Next, lung density was measured in a 6-mm{sup 2} ROI in a fixed anatomic location in each of the scans. Results: Day-to-day variability in respiratory rate with our technique was 13%. All metrics except for breath-hold lung volume were correlated with survival: lung density on free-breathing (r=−0.7482,p<0.01) and breath-hold images (r=−0.5864,p<0.01), free-breathing lung volume (r=0.7179,p<0.01), and respiratory rate (r= 0.6953,p<0.01). Lung density on free-breathing scans was correlated with respiratory rate (r=0.7142,p<0.01) and lung density on breath-hold scans (r=0.5543,p<0.01). One significant practical hurdle in the CBCT measurements was that at least one lobe of the lung was collapsed in 36% of free-breathing scans and 45% of breath-hold scans. Conclusion: Lung density and lung volume on free-breathing CBCTs and respiratory rate outperform breath-hold CBCT measurements as indicators for survival from radiation-induced pneumonitis. This work was partially funded by Elekta.

60 APPLIED LIFE SCIENCES↗

Potential benefits of dosimetric VMAT tracking verified with 3D film measurements

Purpose: To evaluate three different plan adaptation strategies using 3D film-stack dose measurements of both focal boost and hypofractionated prostate VMAT treatments. The adaptation strategies (a couch shift, geometric tracking, and dosimetric tracking) were applied for three realistic intrafraction prostate motions. Methods: A focal boost (35 × 2.2 and 35 × 2.7 Gy) and a hypofractionated (5 × 7.25 Gy) prostate VMAT plan were created for a heterogeneous phantom that allows for internal prostate motion. For these plans geometric tracking and dosimetric tracking were evaluated by ionization chamber (IC) point dose measurements (zero-D) and measurements using a stack of EBT3 films (3D). The geometric tracking applied translations, rotations, and scaling of the MLC aperture in response to realistic prostate motions. The dosimetric tracking additionally corrected the monitor units to resolve variations due to difference in depth, tissue heterogeneity, and MLC-aperture. The tracking was based on the positions of four fiducial points only. The film measurements were compared to the gold standard (i.e., IC measurements) and the planned dose distribution. Additionally, the 3D measurements were converted to dose volume histograms, tumor control probability, and normal tissue complication probability parameters (DVH/TCP/NTCP) as a direct estimate of clinical relevance of the proposed tracking. Results: Compared to the planned dose distribution, measurements without prostate motion and tracking showed already a reduced homogeneity of the dose distribution. Adding prostate motion further blurs the DVHs for all treatment approaches. The clinical practice (no tracking) delivered the dose distribution inside the PTV but off target (CTV), resulting in boost dose errors up to 10%. The geometric and dosimetric tracking corrected the dose distribution’s position. Moreover, the dosimetric tracking could achieve the planned boost DVH, but not the DVH of the more homogeneously irradiated prostate. A drawback of both the geometric and dosimetric tracking was a reduced MLC blocking caused by the rotational component of the MLC aperture corrections. Because of the used CTV to PTV margins and the high doses in the considered fractionation schemes, the TCP differed less than 0.02 from the planned value for all targets and all correction methods. The rectal NTCP constraints, however, could not be realized using any of these methods. Conclusions: The geometric and dosimetric tracking use only a limited input, but they deposit the dose distribution with higher geometric accuracy than the clinical practice. The latter case has boost dose errors up to 10%. The increased accuracy has a modest impact [Δ(NT)CP < 0.02] because of the applied margins and the high dose levels used. To allow further margin reduction tracking methods are vital. The proposed methodology could further be improved by implementing a rotational correction using collimator rotations.

60 APPLIED LIFE SCIENCES↗

Neptune long-lived atmospheric features in 2013–2015 from small (28-cm) to large (10-m) telescopes

Since 2013, observations of Neptune with small telescopes (28–50 cm) have resulted in several detections of long-lived bright atmospheric features that have also been observed by large telescopes such as Keck II or Hubble. The combination of both types of images allows the study of the long-term evolution of major cloud systems in the planet. In 2013 and 2014 two bright features were present on the planet at southern mid-latitudes. These may have merged in late 2014, possibly leading to the formation of a single bright feature observed during 2015 at the same latitude. This cloud system was first observed in January 2015 and nearly continuously from July to December 2015 in observations with telescopes in the 2-10-m class and in images from amateur astronomers. These images show the bright spot as a compact feature at -40.1 ± 1.6° planetographic latitude well resolved from a nearby bright zonal band that extended from -42° to -20°. The size of this system depends on wavelength and varies from a longitudinal extension of 8000 ± 900 km and latitudinal extension of 6500 ± 900 km in Keck II images in H and Ks bands to 5100 ± 1400 km in longitude and 4500 ± 1400 km in latitude in HST images in 657 nm. Over July to September 2015 the structure drifted westward in longitude at a rate of 24.48 ± 0.03°/day or -94 ± 3 m/s. This is about 30 m/s slower than the zonal winds measured at the time of the Voyager 2 flyby. Tracking its motion from July to November 2015 suggests a longitudinal oscillation of 16° in amplitude with a 90-day period, typical of dark spots on Neptune and similar to the Great Red Spot oscillation in Jupiter. The limited time covered by high-resolution observations only covers one full oscillation and other interpretations of the changing motions could be possible. HST images in September 2015 show the presence of a dark spot at short wavelengths located in the southern flank (planetographic latitude -47.0°) of the bright compact cloud observed throughout 2015. The drift rate of the bright cloud and dark spot translates to a zonal speed of -87.0 ± 2.0 m/s, which matches the Voyager 2 zonal speeds at the latitude of the dark spot. Identification of a few other features in 2015 enabled the extraction of some limited wind information over this period. This work demonstrates the need of frequently monitoring Neptune to understand its atmospheric dynamics and shows excellent opportunities for professional and amateur collaborations.

79 ASTRONOMY AND ASTROPHYSICS↗

Electromagnetic Tracking of Intrafraction Prostate Displacement in Patients Externally Immobilized in the Prone Position

Purpose: To evaluate intrafraction prostate displacement among patients immobilized in the prone position using real-time monitoring of implanted radiofrequency transponders. Methods and Materials: The Calypso localization system was used to track prostate motion in patients receiving external beam radiation therapy (XRT) for prostate cancer. All patients were treated in the prone position and immobilized with a thermoplastic immobilization device. Real-time measurement of prostate displacement was recorded for each treatment fraction. These measurements were used to determine the duration and magnitude of displacement along the three directional axes. Results: The calculated centroid of the implanted transponders was offset from the treatment isocenter by >=2 mm, >=3 mm, and >=4 mm for 38.0%, 13.9%, and 4.5% of the time. In the lateral dimension, the centroid was offset from the treatment isocenter by >=2 mm, >=3 mm, and >=4 mm for 2.7%, 0.4%, and 0.06% of the time. In the superior-inferior dimension, the centroid was offset from the treatment isocenter by >=2 mm, >=3 mm, and >=4 mm for 16.1%, 4.7%, and 1.5% of the time, respectively. In the anterior-posterior dimension, the centroid was offset from the treatment isocenter by >=2 mm, >=3 mm, and >=4 mm for 13.4%, 3.0%, and 0.5% of the time. Conclusions: Intrafraction prostate displacement in the prone position is comparable to that in the supine position. For patients with large girth, in whom the supine position may preclude accurate detection of implanted radiofrequency transponders, treatment in the prone position is a suitable alternative.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Eulerian adaptive finite-difference method for high-velocity impact and penetration problems

Owing to the complex processes involved, faithful prediction of high-velocity impact events demands a simulation method delivering efficient calculations based on comprehensively formulated constitutive models. Such an approach is presented herein, employing a weighted essentially non-oscillatory (WENO) method within an adaptive mesh refinement (AMR) framework for the numerical solution of hyperbolic partial differential equations. Applied widely in computational fluid dynamics, these methods are well suited to the involved locally non-smooth finite deformations, circumventing any requirement for artificial viscosity functions for shock capturing. Application of the methods is facilitated through using a model of solid dynamics based upon hyper-elastic theory comprising kinematic evolution equations for the elastic distortion tensor. The model for finite inelastic deformations is phenomenologically equivalent to Maxwell s model of tangential stress relaxation. Closure relations tailored to the expected high-pressure states are proposed and calibrated for the materials of interest. Sharp interface resolution is achieved by employing level-set functions to track boundary motion, along with a ghost material method to capture the necessary internal boundary conditions for material interactions and stress-free surfaces. The approach is demonstrated for the simulation of high velocity impacts of steel projectiles on aluminium target plates in two and three dimensions.

Barton, Philip T.↗

A diffusive information preservation method for small Knudsen number flows

The direct simulation Monte Carlo (DSMC) method is a powerful particle-based method for modeling gas flows. It works well for relatively large Knudsen (Kn) numbers, typically larger than 0.01, but quickly becomes computationally intensive as Kn decreases due to its time step and cell size limitations. An alternative approach was proposed to relax or remove these limitations, based on replacing pairwise collisions with a stochastic model corresponding to the Fokker–Planck equation [J. Comput. Phys., 229, 1077 (2010); J. Fluid Mech., 680, 574 (2011)]. Similar to the DSMC method, the downside of that approach suffers from computationally statistical noise. To solve the problem, a diffusion-based information preservation (D-IP) method has been developed. The main idea is to track the motion of a simulated molecule from the diffusive standpoint, and obtain the flow velocity and temperature through sampling and averaging the IP quantities. To validate the idea and the corresponding model, several benchmark problems with Kn ∼ 10{sup −3}–10{sup −4} have been investigated. It is shown that the IP calculations are not only accurate, but also efficient because they make possible using a time step and cell size over an order of magnitude larger than the mean collision time and mean free path, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulations of grain growth in tungsten armor materials under ARC plasma edge operation conditions using an integrated plasma-edge/materials model

An integrated model of grain growth deuterium-exposed tungsten polycrystals, consisting of a two-dimensional vertex dynamics model fitted to atomistic data, has been developed to assess the grain growth kinetics of deuterium-exposed polycrystalline tungsten (W). The model tracks the motion of grain boundaries under the effect of driving forces stemming from grain boundary curvature and differential deuterium concentration accumulation. Here, we apply the model to experimentally synthesized tungsten polycrystals under deuterium-saturated conditions relevant to the ARC concept design. The results indicate rapid grain growth kinetics in the near-surface region adjacent to the plasma, where the temperature reaches 1400 K, whereas the microstructure remains stable deeper in the material with the lower temperature of 1000 K. The combined modeling and analysis further reveal that monolithic tungsten produced via conventional fabrication routes is highly susceptible to grain coarsening at temperatures exceeding 1000 K, largely independent of the magnitude of the applied driving force. Moreover, the accumulation of deuterium near grain boundaries has a pronounced inhibitory effect on grain boundary migration. High-angle grain boundaries ( > 50°) contribute more significantly to the overall grain growth process.

36 MATERIALS SCIENCE↗

Dynamics of Bottlebrush Polymers in Solution by Neutron Spin Echo Spectroscopy

In this work, we present dynamical and morphological studies on poly(dimethylsiloxane) (PDMS)-based bottlebrush polymers in solution. A combination of small-angle neutron scattering (SANS), pulsed field gradient nuclear magnetic resonance (PFG NMR), and neutron spin echo (NSE) spectroscopy was used to identify structural changes inherent in changing the side-chain length while keeping the backbone constant. These morphological changes are mirrored in the diffusion coefficient determined by PFG NMR, resulting in two coefficients for the elongated and one for the more spherical sample. Faster motions are tracked by NSE using the advantage of time- and length-scale resolutions with the diffusion coefficient predetermined by PFG NMR. Hereby, the sample with short side chains relaxes like wormlike micelles considering the longitudinal direction, whereas the dynamics along the radial extension shows a much stronger Q-dependence as known from any theory. The dynamical behavior within the blob region, covered with the more spherical sample, follows the predictions of Zimm as well as of Zilman and Granek (ZG).

36 MATERIALS SCIENCE↗

Dynamic motion trajectory control with nanoradian accuracy for multi-element X-ray optical systems via laser interferometry

The past decades have witnessed the development of new X-ray beam sources with brightness growing at a rate surpassing Moore’s law. Current and upcoming diffraction limited and fully coherent X-ray beam sources, including multi-bend achromat based synchrotron sources and high repetition rate X-ray free electron lasers, puts increasingly stringent requirements on stability and accuracy of X-ray optics systems. Parasitic motion errors at sub-micro radian scale in beam transport and beam conditioning optics can lead to significant loss of coherence and brightness delivered from source to experiment. To address this challenge, we incorporated optical metrology based on interferometric length and angle sensing and real-time correction as part of the X-ray optics motion control system. A prototype X-ray optics system was constructed following the optical layout of a tunable X-ray cavity. On-line interferometric metrology enabled dynamical feedback to a motion control system to track and compensate for motion errors. The system achieved sub-microradian scale performance, as multiple optical elements are synchronously and continuously adjusted. This first proof of principle measurement demonstrated both the potential and necessity of incorporating optical metrology as part of the motion control architecture for large scale X-ray optical systems such as monochromators, delay lines, and in particular, X-ray cavity systems to enable the next generation cavity-based X-ray free electron lasers.

47 OTHER INSTRUMENTATION↗

Imaging a light-induced molecular elimination reaction with an X-ray free-electron laser

Tracking the motion of individual atoms during chemical reactions represents a severe experimental challenge, especially if several competing reaction pathways exist or if the reaction is governed by the correlated motion of more than two molecular constituents. Here we demonstrate how ultrashort X-ray pulses combined with coincident ion imaging can be used to trace molecular iodine elimination from laser-irradiated diiodomethane (CH 2 I 2 ), a reaction channel of fundamental importance but small relative yield that involves the breaking of two molecular bonds and the formation of a new one. We map bending vibrations of the bound molecule, disentangle different dissociation pathways, image the correlated motion of the iodine atoms and the methylene group leading to molecular iodine ejection, and trace the vibrational motion of the formed product. Our results provide a quantitative mechanistic picture behind previously suggested reaction mechanisms and prove that a variety of geometries are involved in the molecular bond formation.

Atomic and molecular interactions with photons↗