Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mix Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Test Results for the SEA Ice Crystal Detector (ICD) under SLD Conditions at the NASA IRT

The Science Engineering Associates hot-wire Ice Crystal Detector was tested under Appendix C and Supercooled Large Drop Conditions at the NASA Icing Research Tunnel, with the purpose of comparing the measurements to the tunnel LWC calibration, and to test the performance of the mixed-phase retrievals of the probe. The liquid water content measured by the total water content sensor of the probe agreed well with the tunnel calibration over a wide range of MVDs, not unexpectedly since the tunnel was calibrated with a similar Multiwire hot-wire probe. A scale factor difference of about 7% was attributed to the lack of an efficiency correction for the Ice Crystal Detector at smaller median volume diameters, and typical sample area uncertainties of liquid water content devices. In addition, the simultaneous equations that are used to retrieve liquid and ice water contents were tested under liquid and glaciated conditions. Using constant ice and water efficiencies for each wire, the equations were found to produce a large and false ice water content retrieval in large median volume diameter liquid cases. By applying a liquid efficiency to the liquid water content sensor that varied with median volume diameter, retrievals were improved such that false ice water content was less than ±10% of the total water content out to the 460 μm median volume diameter limit of the testing. The probe was also tested in glaciated conditions by freezing out a small median volume diameter spray. Using constant ice efficiencies for the two sensors provided from aircraft measurements, the retrieved ice water content was about 40% higher than expected for the case presented, likely due to the ice efficiencies that were used from aircraft measurements of natural clouds being too low for the tunnel’s glaciated sprays. Application of ice efficiencies that vary with particle size and potentially other parameters will be explored for future improvement of retrievals.

Air Craft Icing↗

Test Results for the SEA Ice Crystal Detector (ICD) under SLD Conditions at the NASA IRT

The Science Engineering Associates hot-wire Ice Crystal Detector was tested under Appendix C and Supercooled Large Drop Conditions at the NASA Icing Research Tunnel, with the purpose of comparing the measurements to the tunnel LWC calibration, and to test the performance of the mixed-phase retrievals of the probe. The liquid water content measured by the total water content sensor of the probe agreed well with the tunnel calibration over a wide range of MVDs, not unexpectedly since the tunnel was calibrated with a similar Multiwire hot-wire probe. A scale factor difference of about 7% was attributed to the lack of an efficiency correction for the Ice Crystal Detector at smaller median volume diameters, and typical sample area uncertainties of liquid water content devices. In addition, the simultaneous equations that are used to retrieve liquid and ice water contents were tested under liquid and glaciated conditions. Using constant ice and water efficiencies for each wire, the equations were found to produce a large and false ice water content retrieval in large median volume diameter liquid cases. By applying a liquid efficiency to the liquid water content sensor that varied with median volume diameter, retrievals were improved such that false ice water content was less than ±10% of the total water content out to the 460 μm median volume diameter limit of the testing. The probe was also tested in glaciated conditions by freezing out a small median volume diameter spray. Using constant ice efficiencies for the two sensors provided from aircraft measurements, the retrieved ice water content was about 40% higher than expected for the case presented, likely due to the ice efficiencies that were used from aircraft measurements of natural clouds being too low for the tunnel’s glaciated sprays. Application of ice efficiencies that vary with particle size and potentially other parameters will be explored for future improvement of retrievals.

o Aircraft Icing↗

Testing a dynamical model for mid-latitude sea surface temperature anomalies

The present investigation is concerned with the development and testing of a dynamical model for sea surface temperature (SST) anomalies in the midlatitudes. The model is an extension of the stochastic forcing model, suggested by Frankignoul and Hasselmann (1977), in which SST anomalies arise naturally as a response of the slowly varying upper ocean to the rapidly varying air-sea fluxes. The conducted analysis confirms strongly the validity of this model. The results suggest that advection by mean ocean currents plays an important role in some regions. Attention is given to the governing equations, a statistical model, SST anomaly advection, heat flux anomalies, wind-driven mass transport in the mixed layer, mixed-layer depth, aspects of model testing, and the atmospheric forcing.

Frankignoul, C.↗

Plug20 Test Report: Particle Image Velocimetry (PIV) Measurements

This report provides turbulent flow statistics made using particle image velocimetry (PIV) for several internally mixed exhaust systems with external plugs (Plug20 designs). The tests were conducted at the NASA Glenn Research Center’s Aero-Acoustic Propulsion Laboratory (AAPL) in May and June 2022. The corresponding acoustic data for the configurations and flows presented in this report can be found in an earlier Technical Memorandum, NASA/TM-20210010291, “Plug20 Test Report.” The Plug20 nozzle family was designed to represent commercial supersonic vehicles in the 2025 to 2035 timeframe with a bypass ratio around 4, having an internal mixer, with and without an external plug to improve nacelle boattail drag and shock. The flow conditions measured represent engine cycles for commercial supersonic aircraft at takeoff, having pressure ratios of 2.0 and heated fan and core streams, measured both with and without a flight stream surrounding the plume. A few unheated flow conditions were also tested to tie results to other baseline test results. The PIV measurements in both streamwise and cross-stream planes are described, along with brief analysis to visually catalog the contents and confirm their validity. In this analysis, the streamwise PIV is found to match benchmark datasets within its experimental error. However, the cross-stream turbulent quantities measured by two systems do not match each other or the streamwise measurements in amplitude—caution is required when using the cross-stream data. Data acquired and included in this report are (1) velocity statistics of the plumes in both a streamwise and several cross-stream planes, and (2) the hot nozzle geometry. Tabular forms of the data and computer-aided design (CAD) files of the hot geometry are presented as supplemental files described in Appendix A (TM-20230006779SUPPL1.zip) and Appendix B (TM-20230006779SUPPL2.zip).

Turbulence↗

Reliability of Upright and Supine Power Measurements Using an Inertial Load Cycle Ergometer

Practical, reliable, and time efficient methods of measuring muscular power are desirable for both research and applied testing situations. The inertial-load cycling method (ILC; Power/Cycle, Austin, TX) requires subjects to pedal as fast as possible against the inertial load of a flywheel for only 3-5 seconds, which could help reduce the time and effort required for maximal power testing. PURPOSE: 1) To test the intramachine reliability of ILC over 3 separate sessions, 2) to compare postural stance (upright vs. supine) during testing, and 3) to compare the maximal power (Pmax) output measured using ILC to that obtained from traditional isokinetic and leg press testing. METHODS: Subjects (n = 12) were tested on 4 non-consecutive days. The following tests were done on the first day of testing: isometric knee extension, isokinetic knee extension at several speeds, isokinetic power/endurance at 180/sec (Biodex System 4), leg press maximal isometric force, and leg press power/endurance. The other 3 days consisted exclusively of ILC testing. Subjects performed 6 ILC tests in an upright position and 6 ILC tests in a supine position on each day. The starting position was counterbalanced. Mixed-effects linear modeling was used to determine if any differences existed between testing days and between upright and supine for Pmax and revolutions per minute at Pmax (RPMpk). Mixed-modeling was also used to calculate intraclass correlation coefficients (ICC) to determine the reliability of the ILC on each testing day for Pmax and RPMpk (ICCs were calculated separately for upright and supine). gKendall fs Tau a h was used to determine the association between ILC Pmax and isokinetic and leg press data. RESULTS: For Pmax, significant differences were found between days 1 and 2 (upright: p = 0.018; supine: p = 0.014) and between days 1 and 3 (upright: p = 0.001; supine: p = 0.002), but not between days 2 and 3 (upright: p = 0.422; supine: p = 0.501). Pmax ICC values were greater than or equal to 0.97 for all days in both positions. Also, no significant differences between upright and supine postures were found for Pmax. No significant differences between days were found for RPMpk; however, there was a significant posture effect (upright greater than supine). Moderate correlations were observed between ILC Pmax and isokinetic and leg press tests (upright: 0.64-0.79, supine: 0.52-0.82). CONCLUSIONS: Overall, ILC is a very reliable test. Since a significant difference was found between day 1 and the other ILC testing days, it is suggested that day 1 of ILC testing should be used as a familiarization session to allow for subject learning. No significant difference in Pmax was seen from test 3 to test 6. However, an increase of 1.3% was observed from test 4 to test 6. Therefore, although 4 tests may be sufficient for most subjects to produce Pmax, in some cases 6 tests may be required. PRACTICAL APPLICATIONS: No differences were seen in Pmax between upright and supine positions despite differing RPMpk. This suggests that ILC testing can be used to provide reliable testing both in an upright position (appropriate for athletes) and in research (e.g., bed rest) or rehabilitation settings where supine testing is necessary. Future research should evaluate whether peak power measurements obtained with the ILC are sensitive to changes such as that observed with training and de-training.

Wickwire, P. J.↗

NESC Review of the 8-Foot High Temperature Tunnel (HTT) Oxygen Storage Pressure Vessel Inspection Requirements

The 8-Foot HTT (refer to Figure 4.0-1) is used to conduct tests of air-breathing hypersonic propulsion systems at Mach numbers 4, 5, and 7. Methane, Air, and LOX are mixed and burned in a combustor to produce test gas stream containing 21 percent by volume oxygen. The NESC was requested by the NASA LaRC Executive Safety Council to review the rationale for a proposed change to the recertification requirements, specifically the internal inspection requirements, of the 8-Foot HTT LOX Run Tank and LOX Storage Tank. The Run Tank is an 8,000 gallon cryogenic tank used to provide LOX to the tunnel during operations, and is pressured during the tunnel run to 2,250 pounds per square inch gage (psig). The Storage Tank is a 25,000 gallon cryogenic tank used to store LOX at slightly above atmospheric pressure as a external shell, with space between the shells maintained under vacuum conditions.

Gilbert, Michael↗

Influences of Introduced Yttrium Oxide Particles on Superalloy 718

Additive manufacturing has proven useful for introducing oxide particles into superalloys, to provide oxide dispersion strengthening (ODS) at high temperatures. This study screened how such an approach can influence microstructure and failure modes for superalloy 718. The objective of this study was to compare tensile and creep failure modes for additively manufactured superalloy 718 having introduced oxide particles. Fine yttrium-oxide (yttria) particles were introduced into 718 powder using two different powder mixing methods. Additive manufacturing by laser powder bed fusion was then used to prepare specimen blanks for each case, oriented parallel and transverse to the building direction. These were subsequently given consistent stress relief, hot isostatic pressurization, and final heat treatments, then subjected to tensile and creep tests at varied temperatures. Additively manufactured 718 without ODS (“no-ODS”) had nearly equiaxed grains at 50 μm in width. Roll-mixed ODS material had a bimodal grain size distribution, with fine grains at 9 μm and coarse grains at 66 μm in average width. The fine grains were elongated about 5x in the building direction. Acoustic-mixed ODS materials had grains at 10 μm in width that were elongated about 10x in the build direction. Compared to no-ODS, roll-mixed and acoustic mixed ODS materials did not show improved tensile strengths at room temperature, 760 °C, and 1093 °C. The tensile failure strains parallel to the building direction of roll-mixed ODS material were lowest in these tests. Flattened clumps of yttria had formed transverse to the building direction in roll-mixed material, which were easily cracked. Creep rupture response at 760 °C in the building direction was highest for acoustic-mixed material test. Creep tests at 1093 °C showed varied results, with low rupture lives associated with enhanced cavitation at grain boundaries and surface oxidation. Transverse to the building direction, all three materials had low failure strains in tests at 760 °C. The elongated grain boundaries failed readily in all transverse specimens tested at 760 °C and 1093 °C.

oxide dispersion strengthening↗

Status Report on the Penn State RBCC Test Program

The status of the RBCC ejector mode research program at Penn State is reviewed. Recent hardware modifications and measurement system improvements are discussed, including the motivation for these changes. Results from a series of tests with a single thruster configuration at a chamber pressure of 200 psia and with an area ratio 3.3 nozzle are presented. These results indicate that the primary (rocket exhaust) and secondary (entrained air) flow streams mix much more rapidly than a previous test series with an area ratio of 6.0 nozzle. Finally, the plans for a test series with a twin thruster configuration are discussed.

Cramer, J.↗

Enhanced Mixing in a Rectangular Duct

An experimental investigation of the mixing of non-reacting opposed rows of jets injected normal to a confined rectangular crossflow has been conducted. Planar Mie-scattering was used to measure the time-average concentration distribution of the jet fluid in planes perpendicular to the duct axis. Particular emphasis was placed on the study of closely spaced orifice configurations applicable to the mixing zone of an RQL combustor. Baseline studies were performed of mixing under "ideal" conditions, i.e., plenum fed jets injecting into a crossflow uniform in velocity and turbulence intensity. In addition, more practical ("non-ideal") issues encountered during hardware design were also studied. As in other studies, mixing effectiveness, determined using a spatial unmixedness parameter based on the variance of mean jet concentration distributions, was found to be optimum when the spacing-to-duct-height ratio was inversely proportional to the square root of the jet-to-mainstream momentum-flux ratio. This relationship is suitable for design under ideal flow conditions. Inlet flow boundary conditions of the jet and approach flow (mainstream) were found to strongly influence mixing performance, but no attempt was made to determine optimum performance under non-ideal conditions. The tests performed do offer some guidance as to expected mixing behavior for several common variables likely to be imposed by hardware constraints. Additionally, in this study it was found that for rows of orifices with opposite centerlines inline, mixing was similar for blockages up to 89 percent (previous crossflow mixing studies concerned with dilution zone configurations, blockages were typically less than 50 percent). Lower levels of unmixedness were obtained as a function of downstream location when axial injection length was minimized. Mixing may be enhanced if orifice centerlines of opposed rows are staggered, but blockage must be =50 percent in this configuration. Round hole and "square" orifice shapes had similar performance. Other variations in orifice shape did not substantially augment overall mixing performance. Furthermore an isothermal mixing data set was generated and used by CFDRC as input to a NO(x) inference code.

Liscinsky, D. S.↗

Evaluation of Electrochemically Generated Potable Water Disinfectants for Use on the International Space Station

Microbial contamination and subsequent growth in spacecraft water systems are constant concerns for missions involving human crews. The current potable water disinfectant for the International Space Station (ISS) is iodine; however, with the end of the Space Shuttle program, there is a need to develop redundant biocide systems that do not require regular up ]mass dependencies. Throughout the course of a year, four different electrochemical systems were investigated as a possible biocide for potable water on the ISS. Research has indicated that there is a wide variability with regards to efficacy in both concentration and exposure time of these disinfectants, therefore baseline efficacy values were established. This paper describes a series of tests performed in order to establish optimal concentrations and exposure times for four disinfectants against single and mixed species planktonic and biofilm bacteria. Results of the testing determined whether these electrochemical disinfection systems are able to produce a sufficient amount of chemical in both concentration and volume to act as a biocide for potable water on ISS.

Rodriquez, Branelle↗

Material Testing in Support of the ISS Electrochemical Disinfection Feasibility Study

Microbial contamination and subsequent growth in spacecraft water systems are constant concerns for missions involving human crews. The current potable water disinfectant for the International Space Station (ISS) is iodine; however, with the end of the Space Shuttle program, there is a need to develop redundant biocide systems that do not require regular up ]mass dependencies. Throughout the course of a year, four different electrochemical systems were investigated as a possible biocide for potable water on the ISS. Research has indicated that there is a wide variability with regards to efficacy in both concentration and exposure time of these disinfectants, therefore baseline efficacy values were established. This paper describes a series of tests performed in order to establish optimal concentrations and exposure times for four disinfectants against single and mixed species planktonic and biofilm bacteria. Results of the testing determined whether these electrochemical disinfection systems are able to produce a sufficient amount of chemical in both concentration and volume to act as a biocide for potable water on ISS.

Rodriquez, Branelle↗

The effect of mixed mode precracking on the mode 1 fracture toughness of composite laminates

We subjected double cantilever beam specimens from four different composite materials to mixed-mode precracking. Three different precracking mode 1 to mode 2 ratios were used--1 to 4, 1 to 1, and 4 to 1. Following precracking the specimens were tested for mode I fracture toughness. The mixed-mode precracking often influenced the mode 1 toughness and its influence persisted for as much as 60 mm of mode 1 crack growth. We tested composites with untoughened matrices, composites with rubber-toughened matrices, and composites with interlayer toughening. Depending on material type and precracking mode ratio, the precracking could cause either a significant increase or a significant decrease in the mode 1 fracture toughness.

Shankar, Prashanth↗

Rime-, mixed- and glaze-ice evaluations of three scaling laws

This report presents the results of tests at NASA Lewis to evaluate three icing scaling relationships or 'laws' for an unheated model. The laws were LWC x time = constant, one proposed by a Swedish-Russian group and one used at ONERA in France. Icing tests were performed in the NASA Lewis Icing Research Tunnel (IRT) with cylinders ranging from 2.5- to 15.2-cm diameter. Reference conditions were chosen to provide rime, mixed and glaze ice. Scaled conditions were tested for several scenarios of size and velocity scaling, and the resulting ice shapes compared. For rime-ice conditions, all three of the scaling laws provided scaled ice shapes which closely matched reference ice shapes. For mixed ice and for glaze ice none of the scaling laws produced consistently good simulation of the reference ice shapes. Explanations for the observed results are proposed, and scaling issues requiring further study are identified.

Anderson, David N.↗

Modeling of three-dimensional mixing and reacting ducted flows

A computer code based on a finite-element solution algorithm is developed to perform an analytical investigation on the turbulent mixing and reaction of hydrogen jets injected from multiple orifices transverse and parallel to a supersonic airstream. A laser optical cavity flow field was also analyzed to demonstrate the generality of the proposed model. Computational results provide a three-dimensional description of velocity, temperature, and species-concentration fields downstream of injection. Major conclusions are that the analysis has immediate utility in evaluating the mixing effectiveness of transverse H2 injection data since it has been tested in its ability to model this type of data and that turbulent mixing length theory, constant effective Prandtl number, and a Lewis number of unity provide reasonable agreement with transverse H2 injection data downstream of the near-injection region. Efforts are presently being directed toward using the code in modeling laser and scramjet data for a wide range of flow conditions.

Zelazny, S. W.↗

A mixed formulation finite element for linear thin shell analysis

An eight node curved thin shell slement was tested. The element is based on the degenerate solid concept and the mixed formulation with the independent inplane and transverse shear strains. The number of unknown parameters in the assumed strains is chosen to alleviate the spurious constaining or locking effect. It is indicated that for a pinched cylindrical shell with diaphragmed ends and fixed ends the present element shows good performance.

Lee, S. W.↗

Executive summary, aerothermal modeling program, phase 1

Submodels used in the combustor analytical models that were successfully used in designing advanced technology combustors were assessed. Specific recommendations for further improvement of model accuracy for combustor design purposes were made. Based upon an exhaustive literature survey, a number of test cases were selected to assess accuracy of submodels of turbulence, turbulence/chemistry interaction, spray combustion, and dilution jet mixing processes within a confined cross-stream. These test cases included simple flows and complex flows with and without swirl. Nonrecirculating and recirculating, and nonreactive and reactive flows were investigated. It was concluded that the current models give qualitative trends for the recirculating secondary flows (as encountered in a gas turbine combustor primary zone), but the predictions are good for the dilution zone.

Srinivasan, R.↗

Short efficient ejector systems

A research program was conducted to improve the performance of low pressure ratio ejector systems. The results show that short, efficient ejectors operating at nearly ideal performance are possible through the use of forced mixer lobes. Forced mixer lobes generate large scale axial vorticity which results in rapid mixing and improved diffuser performance. Ejector testing was conducted using both an ejector wind tunnel. Numerous mixer lobe variations were tested to develop lobe design guidelines. The improved performance of mixer-ejectors is presented over a range of operating conditions. Results of mixer lobe angle, penetration, and alignment are presented. Lobe angles of up to 25 deg, coupled with diffuser wall angles over 20 deg, operate without separation, allowing efficient, short ejector systems. Both warm and cold flow test results are presented. Temperature similarity expressions previously developed are further formulated and verified.

Presz, Walter M., Jr.↗