Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Studies on magnetic properties of chemically synthesized crystalline calcium ferrite nanoparticles

Spinel-type ferrites have taken a very important role for modern electronic industry. Most of these ferrites exhibit low-loss dielectric properties, high resistivity, low eddy current and also high temperature ferromagnetism. Calcium ferrite is one such important metal oxide which is environmentally safe, chemically stable, low cost and greatly abundant. This outstanding material of calcium ferrite is synthesized by a simple chemical precipitation method using NaOH as the precipitating agent. Ferric chloride anhydrous (FeCl{sub 3}) and Calcium chloride dihydrate (CaCl{sub 2}.2H{sub 2}O) were used as iron and calcium sources respectively. The samples were heated at 200°C for 8h to obtain homogeneous powder of Calcium ferrite. The powders were characterized by using X-ray diffraction (XRD), field emission scanning electron microscope (FESEM), Transmission electrical microscopy (TEM), and Fourier transform infrared spectroscopic (FTIR) measurements. The polycrystalline nature of the sample was confirmed by X-ray diffraction study. The magnetic properties of the sample were investigated by vibrating sample magnetometer (VSM) measurements. Magnetization curve of the prepared sample depicts that as synthesized calcium ferrite nanoparticles have saturation magnetic moment of 1.74 emu/g and the coercivity of 35.08 Oe with superparamagnetic behavior. The synthesized calcium ferrite nanoparticles with such magnetic properties will be a candidate material for different applications in electronics and exploring its functionality in the field of recently developing semiconductor device physics and spintronics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-Precision Mapping of Diamond Crystal Strain Using Quantum Interferometry

Crystal-strain variation imposes significant limitations on many quantum sensing and information applications for solid-state defect qubits in diamond. Thus, the precision measurement and control of diamond crystal strain is a key challenge. Here, we report diamond strain measurements with a unique set of capabilities, including micron-scale spatial resolution, a millimeter-scale field of view, and a 2-order-of-magnitude improvement in volume-normalized sensitivity over previous work, reaching 5(2)×10 -8 /√Hzμm -3 (with spin-strain coupling coefficients representing the dominant systematic uncertainty). We use strain-sensitive spin-state interferometry on ensembles of nitrogen-vacancy (N-V) color centers in single-crystal bulk diamond with low strain gradients. This quantum interferometry technique provides insensitivity to magnetic-field inhomogeneity from the electronic and nuclear spin bath, thereby enabling long N-V–ensemble electronic spin dephasing times and enhanced strain sensitivity, as well as broadening the potential applications of the technique beyond isotopically enriched or high-purity diamond. We demonstrate the strain-sensitive measurement protocol first on a confocal scanning laser microscope, providing quantitative measurement of sensitivity as well as three-dimensional strain mapping; and second on a wide-field-imaging quantum diamond microscope. Our strain-microscopy technique enables fast, sensitive characterization for diamond material engineering and nanofabrication; as well as diamond-based sensing of strains applied externally, as in diamond anvil cells or embedded diamond stress sensors, or internally, as by crystal damage due to particle-induced nuclear recoils.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ferroelectricity in a semiconducting all-inorganic halide perovskite

Ferroelectric semiconductors are rare materials with both spontaneous polarizations and visible light absorptions that are promising for designing functional photoferroelectrics, such as optical switches and ferroelectric photovoltaics. The emerging halide perovskites with remarkable semiconducting properties also have the potential of being ferroelectric, yet the evidence of robust ferroelectricity in the typical three-dimensional hybrid halide perovskites has been elusive. Here, we report on the investigation of ferroelectricity in all-inorganic halide perovskites, CsGeX 3 , with bandgaps of 1.6 to 3.3 eV. Their ferroelectricity originates from the lone pair stereochemical activity in Ge (II) that promotes the ion displacement. This gives rise to their spontaneous polarizations of ~10 to 20 μC/cm 2 , evidenced by both ab initio calculations and key experiments including atomic-level ionic displacement vector mapping and ferroelectric hysteresis loop measurement. Furthermore, characteristic ferroelectric domain patterns on the well-defined CsGeBr 3 nanoplates are imaged with both piezo-response force microscopy and nonlinear optical microscopic method.

36 MATERIALS SCIENCE↗

Particle image identification and correlation analysis in microscopic holographic particle image velocimetry

This paper discusses the different analysis methods used in holographic particle image velocimetry to measure particle displacement and compares their relative performance. A digital holographic microscope is described and is used to record the light scattered by particles deposited on cover slides that are displaced between exposures. In this way, particle position and displacement are controlled and a numerical data set is generated. Data extraction using nearest neighbor analysis and correlation of either the reconstructed complex amplitude or intensity fields is then investigated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Femtosecond laser damage threshold and nonlinear characterization in bulk transparent SiC materials

Semi-insulating and conducting SiC crystalline transparent substrates were studied after being processed by femtosecond (fs) laser radiation (780 nm at 160 fs). Z-scan and damage threshold experiments were performed on both SiC bulk materials to determine each sample's nonlinear and threshold parameters. 'Damage' in this text refers to an index of refraction modification as observed visually under an optical microscope. In addition, a study was performed to understand the damage threshold as a function of numerical aperture. Presented here for the first time, to the best of our knowledge, are the damage threshold, nonlinear index of refraction, and nonlinear absorption measured values.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deposition, Diagenesis, and Sequence Stratigraphy of the Pennsylvanian Morrowan and Atokan Intervals at Farnsworth Unit

Farnsworth Field Unit (FWU), a mature oilfield currently undergoing CO2-enhanced oil recovery (EOR) in the northeastern Texas panhandle, is the study area for an extensive project undertaken by the Southwest Regional Partnership on Carbon Sequestration (SWP). SWP is characterizing the field and monitoring and modeling injection and fluid flow processes with the intent of verifying storage of CO2 in a timeframe of 100–1000 years. Collection of a large set of data including logs, core, and 3D geophysical data has allowed us to build a detailed reservoir model that is well-grounded in observations from the field. This paper presents a geological description of the rocks comprising the reservoir that is a target for both oil production and CO2 storage, as well as the overlying units that make up the primary and secondary seals. Core descriptions and petrographic analyses were used to determine depositional setting, general lithofacies, and a diagenetic sequence for reservoir and caprock at FWU. The reservoir is in the Pennsylvanian-aged Morrow B sandstone, an incised valley fluvial deposit that is encased within marine shales. The Morrow B exhibits several lithofacies with distinct appearance as well as petrophysical characteristics. The lithofacies are typical of incised valley fluvial sequences and vary from a relatively coarse conglomerate base to an upper fine sandstone that grades into the overlying marine-dominated shales and mudstone/limestone cyclical sequences of the Thirteen Finger limestone. Observations ranging from field scale (seismic surveys, well logs) to microscopic (mercury porosimetry, petrographic microscopy, microprobe and isotope data) provide a rich set of data on which we have built our geological and reservoir models.

04 OIL SHALES AND TAR SANDS↗

Meteorites, Microfossils and Exobiology

The discovery of evidence for biogenic activity and possible microfossils in a Martian meteorite may have initiated a paradigm shift regarding the existence of extraterrestrial microbial life. Terrestrial extremophiles that live in deep granite and hydrothermal vents and nanofossils in volcanic tuffs have altered the premise that microbial life and microfossils are inconsistent with volcanic activity and igneous rocks. Evidence for biogenic activity and microfossils in meteorites can no longer be dismissed solely because the meteoritic rock matrix is not sedimentary. Meteorite impact-ejection and comets provide mechanisms for planetary cross-contamination of biogenic chemicals, microfossils, and living microorganisms. Hence, previously dismissed evidence for complex indigenous biochemicals and possible microfossils in carbonaceous chondrites must be re-examined. Many similar, unidentifiable, biological-like microstructures have been found in different carbonaceous chondrites and the prevailing terrestrial contaminant model is considered suspect. This paper reports the discovery of microfossils indigenous to the Murchison meteorite. These forms were found in-situ in freshly broken, interior surfaces of the meteorite. Environmental Scanning Electron Microscope (ESEM) and optical microscopy images indicate that a population of different biological-like forms are represented. Energy Dispersive Spectroscopy reveals these forms have high carbon content overlaying an elemental distribution similar to the matrix. Efforts at identification with terrestrial microfossils and microorganisms were negative. Some forms strongly resemble bodies previously isolated in the Orgueil meteorite and considered microfossils by prior researchers. The Murchison forms are interpreted to represent an indigenous population of the preserved and altered carbonized remains (microfossils) of microorganisms that lived in the parent body of this meteorite at diverse times during the past 4.5 billion years (Gy).

Hoover, Richard B.↗

Gas delivery system for environmental transmission electron microscope

A portable, compact gas delivery system can support an environmental transmission electron microscope. Environment transmission electron microscopy provides researchers a unique capability of assessing a material's surface conditions at atomic resolution in a variety of reactive and oxidizing environments. The ability to precisely control the analysis chamber's environmental conditions over time is key to the success of a typical surface analysis. The gas delivery system provides the correct balance or pressure delivery precision, contamination control, and gas isolation.

Nogan, John Joseph↗

Chloride-Induced Stress Corrosion Cracking Characteristics of the Used Nuclear Fuel Canister Material

The used nuclear fuel (UNF) dry storage systems are located in the coastal and lake/river-side regions, the service time of which is 60 years and more. One type of dry storage systems is composite of a thin-walled austenitic stainless steel (SS) welded canister and a concrete overpack. The air flows through the canister surface and brings away the decay heat. Meanwhile, the air brings the salt species into the canister and make them deposit on the surface. The salt deposit will be deliquescent when absorbing the moisture air, being corrosive to the surface. NRC and other programs claimed that chloride induced stress corrosion cracking (CISCC) would lead to the canister failure, being one of the major technical gaps for extended dry storage systems. CISCC is induced by the combined influence of the aggressive environment (chloride ions in our case) and tensile stresses (residual stresses in our case) on the susceptible materials (the austenitic SS in our case). Chrome (Cr), as one of the chemical compositions of SSs, plays an important role in the corrosion resistance. It can form a chrome-rich inner barrier oxide layer to prevent the SS from corrosion. However, chloride ions can easily break down the barrier and accelerate dissolution of the underlying metal, the phenomena of which is pitting corrosion. Pitting is the precursor to CISCC as which provides the combination of a local aggressive solution chemistry and a stress concentrating feature. Accordingly, CISCC invariably originates from the pits, and cracks that have nucleated on pit walls can grow around the pit and coalesce to form a complete through-crack. Significant tensile residual stresses, caused by the welding process, exist throughout the thickness of the canister wall. Enos and Bryan found that large residual stresses were in the full-scale mockup container simulating a canister, which supports the SCC propagation. It is therefore interesting to achieve a good knowledge about the effect of welding on the durability of SSs, especially in the corrosive environment. In order to understand the fundamental of the cracking behaviors, it's vital to elucidate the microstructure and microchemistry of cracking. This study focused on observing the CISCC characteristics of the UNF canister material exposed to the humid environment with salt deposit. Extensive micro-characteristics have been achieved by the techniques include focused ion beam/ scanning electron microscope (FIB/SEM), transmission electron microscopy (TEM), energy dispersive spectroscopy (EDS), and optical profiler. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A CCD Camera with Electron Decelerator for Intermediate Voltage Electron Microscopy

Electron microscopists are increasingly turning to Intermediate Voltage Electron Microscopes (IVEMs) operating at 300 - 400 kV for a wide range of studies. They are also increasingly taking advantage of slow-scan charge coupled device (CCD) cameras, which have become widely used on electron microscopes. Under some conditions CCDs provide an improvement in data quality over photographic film, as well as the many advantages of direct digital readout. However, CCD performance is seriously degraded on IVEMs compared to the more conventional 100 kV microscopes. In order to increase the efficiency and quality of data recording on IVEMs, we have developed a CCD camera system in which the electrons are decelerated to below 100 kV before impacting the camera, resulting in greatly improved performance in both signal quality and resolution compared to other CCDs used in electron microscopy. These improvements will allow high-quality image and diffraction data to be collected directly with the CCD, enabling improvements in data collection for applications including high-resolution electron crystallography, single-particle reconstruction of protein structures, tomographic studies of cell ultrastructure and remote microscope operation. This approach will enable us to use even larger format CCD chips that are being developed with smaller pixels.

47 OTHER INSTRUMENTATION↗

A study of the process of decomposition of supersaturated GaAs:Fe solid solution by scanning probe microscopy

Using an atomic-force microscope, the decomposition of the supersaturated solid solution of iron-doped GaAs (GaAs:Fe) is studied. GaAs:Fe samples were obtained in the course of high-temperature diffusion of Fe into GaAs and subsequent annealing at a temperature by 200 deg. C below the doping temperature. The measurements are performed for transverse cleavages along the cleavage planes of the GaAs:Fe wafers. It is shown that, during annealing of the GaAs:Fe samples, the supersaturated alloy decomposes with the formation of particles of the second phase from {approx}50 nm to {approx}1 {mu}m in size. The particles of the second phase possess ferromagnetic properties at room temperature.

36 MATERIALS SCIENCE↗

Characterizing the Two and Three DimensionalResolution of an Improved Aberration-corrected STEM

The successful development of third-order aberration correctors in transmission electron microscopy has seen aberration-corrected electron microscopes evolve from a specialist project, custom built at a small number of sites to a common instrument in many modern laboratories. Here we describe some initial results illustrating the two- and three- dimensional performance of an aberration corrected STEM with a prototype improved aberration corrector designed to also minimize fifth-order aberrations and a new, higher brightness gun. We demonstrate a resolution of 0.63 and detection of single dopant atoms with three-dimensional sensitivity.

47 OTHER INSTRUMENTATION↗

Towards Autonomous Experiments by Connecting High Performance Microscopy with High Performance Computing

The digitization of controls, data, and analysis in microscopy is bringing the idea of autonomous microscopes closer to reality than ever before. Automated transmission electron microscopy (TEM) is already fairly routine for some experiments the only require simple repetitive tasks such as imaging biological macromolecules for single particle cryoEM [1], tilt series for electron tomography [2], and movies for crystallography [3]. The vast majority of TEM experiments are conducted completely by human operators who choose the regions of interest, optimize experimental parameters, and make decisions about data quality visually during an experiment. The field is still a long way from having completely autonomous TEMs that can adapt to sample difficulties and tune experimental parameters based on data quality and desired experimental outcomes. Part of the issue is the lack of capability for feeding information learned from on-line, live data analysis back into the on-going experiment [4]. Furthermore, this presentation will discuss current capabilities for large scale data reduction and analysis using high performance computing (i.e. supercomputing) and progress towards developing a true feed-back loop that places data analysis and theory in the experimental loop.

97 MATHEMATICS AND COMPUTING↗

Hard-X-Ray Phase-Difference Microscopy Using a Fresnel Zone Plate and a Transmission Grating

Novel hard x-ray phase imaging microscopy that simply uses an objective and a transmission grating is described. The microscope generated an image that exhibited twin features of a sample with an opposite phase contrast having a separation of a specific distance. Furthermore, the twin features were processed to generate an image mapping the x-ray phase shift through a simple algorithm. The presence of the grating did not degrade the spatial resolution of the microscope. The sensitivity of our microscope to light elements was about 2 orders of magnitude higher than that of the absorption contrast microscope that was attained by simply removing the grating. Our method is attractive for easily appending a quantitative phase-sensitive mode to normal x-ray microscopies, and it has potentially broad applications in biology and material sciences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of single atoms and buried defects in three dimensions by aberration-corrected electron microscope with 0.5-A information limit.

The ability of electron microscopes to analyze all the atoms in individual nanostructures is limited by lens aberrations. However, recent advances in aberration-correcting electron optics have led to greatly enhanced instrument performance and new techniques of electron microscopy. The development of an ultrastable electron microscope with aberration-correcting optics and a monochromated high-brightness source has significantly improved instrument resolution and contrast. In the present work, we report information transfer beyond 50 pm and show images of single gold atoms with a signal-to-noise ratio as large as 10. The instrument's new capabilities were exploited to detect a buried {Sigma}3 {l_brace}112{r_brace} grain boundary and observe the dynamic arrangements of single atoms and atom pairs with sub-angstrom resolution. These results mark an important step toward meeting the challenge of determining the three-dimensional atomic-scale structure of nanomaterials.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Stroboscopic ultrafast imaging using RF strip-lines in a commercial transmission electron microscope

The development of ultrafast electron microscopy (UEM), specifically stroboscopic imaging, has brought the study of structural dynamics to a new level by overcoming the spatial limitations of ultrafast spectroscopy and the temporal restrictions of traditional TEM simultaneously. Combining the concepts governing both techniques has enabled direct visualization of dynamics with spatiotemporal resolutions in the picosecond-nanometer regime. Here, in this study, we push the limits of imaging using a pulsed electron beam via RF induced transverse deflection based on the newly developed 200 keV frequency-tunable strip-line pulser. We demonstrate 0.2 nm spatial resolution at high magnifications and elucidation of Lorentz imaging using the phase-microscopy method. We also present beam coherence measurements and expand our study using the breathing modes of a silicon interdigitated comb under RF excitation which achieves improved temporal synchronization between the electron pulse-train and electric field. A new RF holder has also been developed with impedance matching to the RF signal to minimize transmission power loss to samples and its performance is compared with a conventional sample holder.

47 OTHER INSTRUMENTATION↗

Novel Applications of Scanning Ultrafast Electron Microscopy (SUEM)

The Scanning Ultrafast Electron Microscope (SUEM) was used to image a wide array samples using a variety of standard and non-standard operating conditions on a custom system built in Org. 8942. The ability of this technique to produce high-quality images was assessed during this one year LDRD. To obtain details about the devices imaged, as well as the experimental details, please refer to the classified report from the project manager, Rich Dondero, or the NSP IA lead, Kristina Czuchlewski.

47 OTHER INSTRUMENTATION↗

An ultrahigh vacuum multipurpose specimen chamber with sample introduction system for in situ transmission electron microscopy investigations

A commercial transmission electron microscope (TEM), with flat-plate upper pole piece configuration of the objective lens, and top-entry specimen introduction was modified by introducing an ultrahigh vacuum (UHV) specimen chamber for in situ TEM experimentation. The pumping and design principles and special features of this UHV chamber, which makes it possible to obtain 5 x 10 to the -10th mbar pressure at the site of the specimen, while maintaining the airlock system that allows operation in the 10 to the -10th mbar range within 15 min after specimen change, are described. Design operating pressures and image quality (resolution of metal particles smaller than 1 nm in size) were achieved. Schematic drawings and design dimensions are included.

Heinemann, K.↗