Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microgrid Controller”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Performance Evaluation of Peer-to-Peer Distributed Microgrids Coordination for Voltage Regulation

This paper presents the performance evaluation of a peer-to-peer microgrids coordination algorithm for sub-transmission systems. As distributed energy resources (DERs) in distribution system start to show negative impact to the bulk power system, a paradigm shift is needed for transmission planning and operation. Because distribution substations are located far from the sub-transmission system, and it is hard to use traditional centralized control for real-time control and coordination. Thus, distributed control is a natural choice because it requires less communication and central computation. In this paper, each distribution substation is treated as a microgrid, and the peer-to-peer distributed microgrids control is formulated as a real-time optimal power flow problem to reduce the negative impact in sub-transmission systems. A distributed primal-dual optimization algorithm is adopted to solve the problem. Validation of the peer-to-peer algorithm is performed through the simulation of a real-world sub-transmission system composing of many distribution systems with high renewable penetration. Simulation results show that the peer-to-peer algorithm can achieve satisfactory performance (e.g., voltage regulation) in sub-transmission system by coordinating and controlling DERs in distribution systems.

distributed control↗

Performance Evaluation of Peer-to-Peer Distributed Microgrids Coordination for Voltage Regulation: Preprint

This paper presents the performance evaluation of a peer-to-peer microgrids coordination algorithm for sub-transmission systems. As distributed energy resources (DERs) in distribution system start to show negative impact to the bulk power system, a paradigm shift is needed for transmission planning and operation. Because distribution substations are located far from the sub-transmission system, and it is hard to use traditional centralized control for real-time control and coordination. Thus, distributed control is a natural choice because it requires less communication and central computation. In this paper, each distribution substation is treated as a microgrid, and the peer-to-peer distributed microgrids control is formulated as a real-time optimal power flow problem to reduce the negative impact in sub-transmission systems. A distributed primal-dual optimization algorithm is adopted to solve the problem. Validation of the peer-to-peer algorithm is performed through the simulation of a real-world sub-transmission system composing of many distribution systems with high renewable penetration. Simulation results show that the peer-to-peer algorithm can achieve satisfactory performance (e.g., voltage regulation) in sub-transmission system by coordinating and controlling DERs in distribution systems.

distributed control↗

A Game Changer: Electrifying Remote Communities by Using Isolated Microgrids

Microgrids, as self-contained entities, are of increasing interest in modern electric grids. Microgrids provide a sustainable solution to aggregate distributed energy resources (DERs) [e.g., photovoltaics (PVs), wind turbines], energy storage, and loads in a localized manner, especially in distribution systems. As a controllable unit, a microgrid can manage and balance the source and load power inside it to ensure stable and reliable operation. Moreover, through coordination with upper-level control systems, it can be dispatched and respond to the control commands issued by the central controller in the distribution system-in other words, a system that is effectively a distribution management system (DMS).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Grid-Forming Control Using TAPAS Software Defined Inverters

Here, this paper discusses the design and hardware implementation aspects of state-feedback primary control for grid forming inverters. The primary control consists of two tracking control laws: voltage tracking and frequency/angle tracking. The voltage tracking control requires voltage and current at the inverter's switch terminal (i.e. before the filter). The fundamental component of switch terminal voltage is estimated using the inverter's average model while the switch terminal current is estimated using an observer, thus obviating the need for sensors at the switch terminals. The measurements of frequency and angle(s) needed for frequency/angle tracking are noisy due to measurement noises and inherent delays in the phase locked loop (PLL). Conditioning of these feedback signals is discussed in detail, and the corresponding changes in the control design are provided to better attenuate the impact of noises. Effectiveness of the proposed design and implementation is demonstrated by the implementation results from TAPAS software defined inverter (SDI).

24 POWER TRANSMISSION AND DISTRIBUTION↗

MiGRIDS

MiGRIDS is a software that models islanded microgrid power systems with different controls and components. For example, using load and resource data from a microgrid, you could model it with additional wind turbines, battery etc. You could also try out different dispatch schemes to see which one worked best. MiGRIDS is designed to help optimize the size and dispatch of grid components in a microgrid. While a grid connect feature is expected to be added in the future, islanded operation is the focus. Note that this is a basic implementation and more features and functionality (such as a GUI) are coming! MiGRIDS runs time-step energy balance simulations for different grid components and controls. In smaller microgrid environments, dispatch decisions are being made on the order of seconds. In order to fully capture their effect, this tool lets you run simulations on the order of seconds. The end result is a more realistic representation of what can be achieved by integrating different components and control strategies in a grid.

Morgan, Tawna↗

An Innovative Energy Management System for Microgrids with Multiple Grid-Forming Inverters: Preprint

As more and more grid-forming (GFM) inverter-based resources replace traditional fossil-fueled synchronous generators as the GFM sources in microgrids, the existing microgrid energy management systems (EMSs) need to be updated to control and coordinate multiple GFM inverters that consider system control objectives under different microgrid connection states. For each state, we formulate an optimization problem and apply a real-time feedback-based control algorithm; all together, the control algorithms seamlessly connect the states into a generic EMS. We showcase the EMS on a real-world simulation of a microgrid under the different states to demonstrate its operational effectiveness.

energy management system↗

Introduction to ALERT: A User-Interface Tool for Resilient Optimization

As the cyber-physical systems grow in complexity, there is a need for proactive resilience strategies that involve online, adaptive control actions to best prepare for any impending adversarial events. In this technical effort, supported by RD2C LDRD initiative, the project team designed and demonstrated online strategies – referred to as ALERT controls – for proactive and adaptive tuning of existing optimal controls in a microgrid, with quantifiably assured margins of resilience to various cyber-physical adversarial events. This ALERT functionality is made available to the end-users, e.g., the system operators, via an interactive user-interface. The end-users will not only be able to use the interface to visualize the system’s operation under various cyber-physical adversarial scenarios, but also evaluate the amount of tolerance the system has against selected adversarial perturbations of interest (e.g., malfunctioning sensors, suspected attacked measurements) via the adversarial plots. In this technical report, we briefly outline the algorithmic modules of the developed ALERT control technology, and introduce the user-interface tool that allows end-users (e.g., microgrid operators) to enter their system description, specify various operational and resilience requirements, and evaluate the impact of the control decisions via illustrative plots.

97 MATHEMATICS AND COMPUTING↗

Safety-assured, real-time neural active fault management for resilient microgrids integration

Federated-learning-based active fault management (AFM) is devised to achieve real-time safety assurance for microgrids and the main grid during faults. AFM was originally formulated as a distributed optimization problem. Here, federated learning is used to train each microgrid's network with training data achieved from distributed optimization. The main contribution of this work is to replace the optimization-based AFM control algorithm with a learning-based AFM control algorithm. The replacement transfers computation from online to offline. With this replacement, the control algorithm can meet real-time requirements for a system with dozens of microgrids. By contrast, distributed-optimization-based fault management can output reference values fast enough for a system with several microgrids. More microgrids, however, lead to more computation time with optimization-based method. Distributed-optimization-based fault management would fail real-time requirements for a system with dozens of microgrids. Controller hardware-in-the-loop real-time simulations demonstrate that learning-based AFM can output reference values within 10 ms irrespective of the number of microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Mixed Integer Linear Programming-basedDistributed Energy Management for Three-phaseUnbalanced Active Distribution Network

A mixed integer linear programming (MILP)–baseddistributed energy management for three-phase unbalancedactive distribution network is proposed. Modern distributionnetworks have becoming more and more active with increasingdeployment of microgrids, distributed energy resources (DERs)as well as controllable loads. Considering various ownership andcontrol models of microgrids, DERs and controllable loads, adistributed energy management was formulated using the alternatingdirection method of multipliers (ADMM) algorithm. ByADMM, the distribution management system (DMS) and theseactive components are coordinated through price signals, whichare adjusted according to the generation-load mismatch per nodeper phase. To enable resolution of the ADMM-based distributedoptimization using more accessible and popular MILP solver,different linearization techniques were proposed to linearize theaugmented Lagrangian terms and other nonlinear terms. Resultsof case studies on a three-phase active distribution network withthree microgrids and several DERs and controllable loads validatedthe effectiveness of proposed MILP-based distributed energymanagement. In addition, the capability of proposed method inmitigating phase power unbalance has been demonstrated.

Liu, Guodong↗

Modular Control Architecture for Scalable, Resilient, and Cybersecure Microgrids Test Results [Mojave firmware 1.09 FW valuation]

This quick note outlines what we found after our conversion with you and your team. As suggested, we loaded 1547-2003 source requirements document (SRD) and then went back and loaded 1547-2018 SRD. This did result in implementing the new 1547-2018 settings. This short report focuses on the frequency-watt function and shows a couple of screen shots of the parameter settings via the Mojave HMI interface and plots of the results of the inverter with FW function enabled in both default and most aggressive settings response to frequency events. The first screen shot shows the 1547-2018 selected after selecting 1547-2003.

42 ENGINEERING↗

Microgrid Black Start Challenges: The Role of Grid-Forming Inverters

Grid-forming (GFM) inverters are becoming increasingly important for future power systems, particularly in establishing and restarting microgrids after blackouts. The use of GFM inverters enables microgrids to operate independently of utility power and provide key advantages over synchronous generators in black start scenarios, including rapid startup and stable voltage and frequency support for critical loads. However, inverter-driven black start introduces unique challenges and operational considerations. This article examines key challenges and solutions, emphasizing inverter design, control strategies, and microgrid system requirements. Drawing on analysis, simulation, and experimental results, this article highlights the central role of GFM inverters in ensuring reliable and resilient microgrid operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microgrid to Microgrid Synchronization with Grid-Forming Inverters: Challenges and Solution

Research on network microgrids has primarily focused on control and optimization. However, application aspects such as microgrid-to-microgrid synchronization have not been fully addressed in existing literature. This paper first addresses the challenges of networking microgrids with grid-forming inverter in droop control. Then, it proposes a pre-synchronization algorithm to improves the synchronization speed and transient stability. To improve the speed, the phase difference between adjacent microgrids is minimized. Transients such as inrush current and oscillations are effectively mitigated by increasing the virtual impedance during interconnection. The proposed strategy allows smooth transitions when reconfiguration of the microgrids is needed. The applicability of this strategy to today’s microgrid systems is demonstrated through a validation in a 480V three-phase network microgrid testbed with commercial-grade inverters, protective devices, and switchgear.

Ferrari Maglia, Max↗

Smart technologies enable homes to be efficient and interactive with the grid

Oak Ridge National Laboratory researchers compare two different approaches to test how advanced, energy-efficient building technologies such as smart thermostats, heat pump water heaters, and advanced heat pump HVAC (heating, ventilation and air conditioning) can be optimized within a home and connected at a neighborhood-scale load to a community microgrid in the Alabama Power Smart Neighborhood located in Hoover. Working with Southern Company and Alabama Power, ORNL researchers are pioneering that future where smart homes and smart neighborhoods can benefit both homeowners and utilities, by reducing energy consumption by 44% and peak demand by 34%.This project is one of two neighborhoods in the U.S Department of Energy’s (DOE’s) Connected Neighborhood project, supported by Building Technologies Office , where ORNL researchers leverages DOE investment in micro-grids and responsive, flexible building loads research to improve grid reliability – a goal of DOE’s Grid-interactive Efficient Buildings (GEB) Initiative. Researchers control the neighborhood and microgrid to enable utilities achieve their desired load and cost profiles while ensuring the comfort of homeowners in the Smart Neighborhood. This transactive control approach maximizes the utilization of technical resources of the microgrid and controllable loads, while reducing costs for both the homeowners and Alabama Power. These tests partially seek to determine a more precise range of tolerance with respect to occupant comfort as researchers work to facilitate customer acceptance and perception of new building technologies that enable energy savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Application and Controls Development for Medium-Voltage SiC-Based Grid Interconnects

This paper studies, the grid-interconnection requirements of directly connected medium-voltage (MV) Silicon Carbide-based (SiC-based) converters and details the necessary control implementations. These power electronic converters follow the interconnection standard IEEE 1547-2018, but can also have additional controls supported by the microgrid standards in IEEE 2030.7, which is demonstrated in this work. Additionally, this paper defines the grid applications realized by these directly connected medium-voltage power electronic converters at the distribution scale and demonstrates results. The controls for the studied grid applications are then developed and implemented on the controller. The paper also includes details of the control algorithm development and validations of the control algorithm through hardware-in-the-loop results.

28 EE - Advanced Manufacturing Office (EE-5A)↗

Hydrogen Energy Storage System at Borrego Springs Towards an H2 Enabled 100 Renewable Microgrid

San Diego Gas & Electric's Borrego Springs Microgrid is one of the largest microgrids in the USA, serving 2500 residential customers, 300 commercial and industrial customers, and has a peak demand of approximately 14 MW. This microgrid is located at the end of a long transmission line, and is subjected to extreme weather events like storms, wildfires, and flooding, which frequently cause grid outages. The microgrid currently relies on 3.65 MW of diesel-powered generators to provide grid-forming services during these outages, which results in greenhouse gas and criteria pollutant emissions. However, the microgrid has access to approximately 37 MW of installed solar generation and struggles with overgeneration and curtailment. 1.5 MW/4.5 MWh of grid-scale batteries have been installed to capture some the overgeneration and provide resiliency, but a longer-duration low-greenhouse gas emission energy storage solution is needed. In our project, the team will evaluate in the lab and demonstrate in the field a grid-forming fuel cell inverter that can provide grid-forming services while utilizing hydrogen's energy storage scalability. We will first utilize NREL's Renewable Energy Integration and Optimization (REopt) platform to perform analyses on future microgrid scenarios that use hydrogen assets to reduce or eliminate the need for diesel backup generators. We will then evaluate the grid-forming inverter through power hardware-in-the-loop and controller hardware-in-the-loop experiments at ARIES, and de-risk the field deployment and operation of hydrogen assets in the microgrid setting. Finally, this project will demonstrate the operation of the fuel cell inverter and updated microgrid controller by operating in grid-forming mode in the Borrego Springs microgrid.

Borrego Springs↗

PV Generation and Load Forecasting for Adjuntas PR Community Microgrids

Existing frameworks to forecast time-series photovoltaic (PV) output power and consumer load for microgrid operations and controls assume a near-continuous availability of real-time input features from the field assets such as PV inverters, energy meters, and weather station. These incoming data points are used to periodically retrain models and update forecast snapshots over a moving horizon window, be it one hour-ahead, one-day ahead, or one-week ahead. However, such frameworks are not resilient to disruptions in data availability caused by losses in communications between the field sensors and data loggers. Hence, there is a need for programs that assume no availability of real-time microgrid asset data and still make reliable forecasts that can be used for decision-making. Such programs would be apt to function in extreme weather events such as hurricanes and would use lightweight recursive time-series models to independently forecast solar irradiance and ambient temperature, then compute PV power from those forecasts, as well as independently forecast consumer load. The codebase performs forecasting for the scenario of when the microgrid does not have a reliable access to forecasts or real-time observations of solar irradiance (I) and ambient temperature (AT) and load (Load) to be able to adequately forecast, in real-time, the PV power production or a business' load. In this case, using historical values of PV power and load, a univariate forecasting of generation and consumption are respectively made. The use-case in particular has two sub-scenarios: one, a normal 7-day ahead forecast where the unavailability of real-time data is assumed due to infrastructure issues such as loss of communication or sensor maintenance or service downtimes. Whereas a hurricane-caused unavailability of real-time data requires a second model trained specifically on historical hurricane days to be able to capture the extreme day behavior of generation in particular, and load if applicable. A gradient boosted regression tree comprises an ensemble of additive models that map between the input of historical values (be it irradiance, temperature, or load) and their corresponding output forecasts of a given horizon such that the individual learner predictions are summed up over the total number of such learners in the ensemble to produce an aggregate forecast. A weighting mechanism is applied to the training data in each iteration, where actual and forecast values are compared to penalize incorrect forecasts by increasing the weight and reducing it to reward correct forecasts. The code's benefits are that it: (a) accounts for a contingency where communication loss renders newly measured real-time data unavailable for model tuning and snapshot updates; (b) presents blind forecasting that recursively determines the next time-step value in a horizon using the forecast of the same attribute from a prior step; and (c) employs lightweight models that, once trained, can reliably generalize for different horizons, which make them suitable for enhancing the resilience of field microgrids prone to extreme events that encounter disruptions to data availability.

Sundararajan, Aditya [Oak Ridge National Laborator↗

Comparison of Virtual Oscillator and Droop Control: Preprint

Virtual oscillator control and droop control are two techniques that can be used to ensure synchronization and power sharing of parallel inverters in islanded operation. VOC relies on the implementation of non-linear Van der Pol oscillator equations in the control system of the inverter, acting upon the time-domain instantaneous inverter current and terminal voltage. On the other hand, DC explicitly computes active and reactive power produced by the inverter and relies on limited bandwidth low-pass filters. Even though both methods can be engineered to produce the same steady-state characteristics, their dynamic performances are significantly different. This paper presents analytical and experimental results that aim to compare both methods. It is shown that VOC is inherently faster and enables minimizing the circulating currents. The results are verified using three 120V, 1kW inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using simulators to assess knowledge and behavior of “novice” operators of critical infrastructure under cyberattack events

—The transition from the traditional power grid to the smart grid improves reliability, performance, and management, while simultaneously increasing its susceptibility to cyberattacks. One of the biggest weaknesses in grid security is the human agent responsible for its maintenance and operations. As such, it is crucial to embed hands-on understanding of grid operations and security, especially for students in the Electrical and Computer Engineering (ECE) fields. This paper presents a case study where ECE students from Temple University used an interactive microgrid simulator, "Grid Game", a program developed by Idaho National Laboratory. This case study offers insights into the ECE students’ understanding of key engineering principles (microgrid stability, generation control system, generator inertia, energy storage, and grid security) gained by using the simulator program. Furthermore, the human behavior (strategies to prepare for and respond to cyberattacks, and cooperation and conflict in decision-making) of defenders/ECE students as they experience cyberattacks are also discussed. The paper then offers some limitations and possible suggestions for future research.

24 POWER TRANSMISSION AND DISTRIBUTION↗