Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microfluidics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

In situ molecular imaging of adsorbed protein films in water indicating hydrophobicity and hydrophilicity

Abstract In situ molecular imaging of protein films adsorbed on a solid surface in water was realized by using a vacuum compatible microfluidic interface and time-of-flight secondary ion mass spectrometry (ToF-SIMS). Amino acid fragments from such hydrated protein films are observed and identified in the positive ion mode and the results are in agreement with reported works on dry protein films. Moreover, water clusters from the hydrated protein films have been observed and identified in both the positive and negative ion mode for a series protein films. Thus, the detailed composition of amino acids and water molecules in the hydrated protein films can be characterized, and the protein water microstructures can be revealed by the distinct three-dimensional spatial distribution reconstructed from in situ liquid ToF-SIMS molecular imaging. Furthermore, spectral principal component analysis of amino acid fragment peaks and water cluster peaks provides unique insights into the water cluster distribution, hydrophilicity, and hydrophobicity of hydrated adsorbed protein films in water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-time observation of dynamic structure of liquid-vapor interface at nanometer resolution in electron irradiated sodium chloride crystals

The dynamics and structure of the liquid and vapor interface has remained elusive for decades due to the lack of an effective tool for directly visualization beyond micrometer resolution. Here, we designed a simple liquid-cell for encapsulating the liquid state of sodium for transmission electron microscopic (TEM) observation. The real-time dynamic structure of the liquid-vapor interface was imaged and videoed by TEM on the sample of electron irradiated sodium chloride (NaCl) crystals, a well-studied sample with low melting temperature and quantum super-shells of clusters. The nanometer resolution images exhibit the fine structures of the capillary waves, composed of first-time observed three zones of structures and features, i.e. flexible nanoscale fibers, nanoparticles/clusters, and a low-pressure area that sucks the nanoparticles from the liquid to the interface. Although the phenomenons were observed based on irradiated NaCl crystals, the similarities of the phenomenons to predictions suggest our real-time ovserved dynamic structure might be useful in validating long-debated theoretical models of the liquid-vapor interface, and enhancing our knowledge in understanding the non-equilibrium thermodynamics of the liquid-vapor interface to benefit future engineering designs in microfluidics.

36 MATERIALS SCIENCE↗

Liquid crystal torons in Poiseuille-like flows

Three-dimensional (3D) simulations of the structure of liquid crystal (LC) torons, topologically protected distortions of the LC director field, under material flows are rare but essential in microfluidic applications. Here, we show that torons adopt a steady-state configuration at low flow velocity before disintegrating at higher velocities, in line with experimental results. Furthermore, we show that under partial slip conditions at the boundaries, the flow induces a reversible elongation of the torons, also consistent with the experimental observations. These results are in contrast with previous simulation results for 2D skyrmions under similar flow conditions, highlighting the need for a 3D description of this LC soliton in relation to its coupling to the material flow. These findings pave the way for future studies of other topological solitons, like hopfions and heliknotons, in flowing soft matter systems.

Science & Technology - Other Topics↗

Scalable fabrication of an array-type fixed-target device for automated room temperature X-ray protein crystallography

X-ray crystallography is one of the leading tools to analyze the 3-D structure, and therefore, function of proteins and other biological macromolecules. Traditional methods of mounting individual crystals for X-ray diffraction analysis can be tedious and result in damage to fragile protein crystals. Furthermore, the advent of multi-crystal and serial crystallography methods explicitly require the mounting of larger numbers of crystals. To address this need, we have developed a device that facilitates the straightforward mounting of protein crystals for diffraction analysis, and that can be easily manufactured at scale. Inspired by grid-style devices that have been reported in the literature, we have developed an X-ray compatible microfluidic device that can be used to trap protein crystals in an array configuration, while also providing excellent optical transparency, a low X-ray background, and compatibility with the robotic sample handling and environmental controls used at synchrotron macromolecular crystallography beamlines. At the Stanford Synchrotron Radiation Lightsource (SSRL), these capabilities allow for fully remote-access data collection at controlled humidity conditions. Furthermore, we have demonstrated continuous manufacturing of these devices via roll-to-roll fabrication to enable cost-effective and efficient large-scale production.

chemical engineering↗

Electrodermal activity as a proxy for sweat rate monitoring during physical and mental activities

Electrodermal activity has long been used for mental activity monitoring by measuring skin conductance at specific locations, such as fingertips, with high sweat gland density. However, electrodermal activity has not been considered useful for physical activity monitoring, where large sweat volumes are generated, resulting in the accumulation of sweat at the skin–electrode interface and, thus, preventing further dynamic response to sweating events. Here we show that electrodermal activity can be used as a proxy for sweat loss measurement under both low and high physical activity levels. We use wearable sweat sensors that consist of water-permeable electrodes and microfluidic-based sweat analysers, and show that skin conductance is proportional to the instantaneous sweat loss. We demonstrate that sweat loss during exercise can be estimated by integrating skin conductance over time, which can be applied to assess the body hydration status of exercisers. From multisite measurements of skin conductance, we show that the wrist, forearm and upper arm are reflective of physical activity levels, whereas the finger is indicative of mental activity. Simultaneous measurement of two different sites selectively decouples mental and physical activities.

Biomedical engineering↗

Plant single-cell solutions for energy and the environment

Progress in sequencing, microfluidics, and analysis strategies has revolutionized the granularity at which multicellular organisms can be studied. In particular, single-cell transcriptomics has led to fundamental new insights into animal biology, such as the discovery of new cell types and cell type-specific disease processes. However, the application of single-cell approaches to plants, fungi, algae, or bacteria (environmental organisms) has been far more limited, largely due to the challenges posed by polysaccharide walls surrounding these species’ cells. In this perspective, we discuss opportunities afforded by single-cell technologies for energy and environmental science and grand challenges that must be tackled to apply these approaches to plants, fungi and algae. We highlight the need to develop better and more comprehensive single-cell technologies, analysis and visualization tools, and tissue preparation methods. We advocate for the creation of a centralized, open-access database to house plant single-cell data. Finally, we consider how such efforts should balance the need for deep characterization of select model species while still capturing the diversity in the plant kingdom. Investments into the development of methods, their application to relevant species, and the creation of resources to support data dissemination will enable groundbreaking insights to propel energy and environmental science forward.

59 BASIC BIOLOGICAL SCIENCES↗

Density fluctuations, homeostasis, and reproduction effects in bacteria

Abstract Single-cells grow by increasing their biomass and size. Here, we report that while mass and size accumulation rates of single Escherichia coli cells are exponential, their density and, thus, the levels of macromolecular crowding fluctuate during growth. As such, the average rates of mass and size accumulation of a single cell are generally not the same, but rather cells differentiate into increasing one rate with respect to the other. This differentiation yields a density homeostasis mechanism that we support mathematically. Further, we observe that density fluctuations can affect the reproduction rates of single cells, suggesting a link between the levels of macromolecular crowding with metabolism and overall population fitness. We detail our experimental approach and the “invisible” microfluidic arrays that enabled increased precision and throughput. Infections and natural communities start from a few cells, thus, emphasizing the significance of density-fluctuations when taking non-genetic variability into consideration.

59 BASIC BIOLOGICAL SCIENCES↗

A mathematical framework for thermodynamic computing with applications to chemical reaction networks

The widespread adoption of energy-intensive computing applications has led to a growing need for energy-efficient computing approaches. Thermodynamic computing offers a promising approach for low-energy computation by leveraging the intrinsic computational capabilities of physical, chemical, or biological systems. However, the mathematical foundations of thermodynamic computing require further development to fully realize the potential energy efficiencies, as well as to assess factors like noise and operational speed. In this paper, we establish a mathematical framework for utilizing thermodynamic processes to perform fundamental operations, including addition, subtraction, multiplication, and division. We highlight the use of chemical reactions as potential computational units and explore synthetic chemical and biochemical systems as practical implementations. Additionally, we demonstrate how these principles can be applied to solving complex mathematical problems, such as ordinary differential equations (ODEs) and suggest the necessary components to implement the thermodynamic computing framework using chemical reactions based in a microfluidic device. This work enhances our understanding of thermodynamic processes for natural computing as a basis for scalable, energy-efficient computation in paradigm disruptive next-generation systems.

Cannon, William R. [Pacific Northwest National Lab↗

Hybrid nanocapsules for in situ TEM imaging of gas evolution reactions in confined liquids

Liquid cell transmission electron microscopy (TEM) enables the direct observation of dynamic physical and chemical processes in liquids at the nanoscale. Quantitative investigations into reactions with fast kinetics and/or multiple reagents will benefit from further advances in liquid cell design that facilitate rapid in situ mixing and precise control over reagent volumes and concentrations. This work reports the development of inorganic–organic nanocapsules for high-resolution TEM imaging of nanoscale reactions in liquids with well-defined zeptoliter volumes. These hybrid nanocapsules, with 48 nm average diameter, consist of a thin layer of gold coating a lipid vesicle. As a model reaction, the nucleation, growth, and diffusion of nanobubbles generated by the radiolysis of water is investigated inside the nanocapsules. When the nanobubbles are sufficiently small (10–25 nm diameter), they are mobile in the nanocapsules, but their movement deviates from Brownian motion, which may result from geometric confinement by the nanocapsules. Gases and fluids can be transported between two nanocapsules when they fuse, demonstrating in situ mixing without using complex microfluidic schemes. The ability to synthesize nanocapsules with controlled sizes and to monitor dynamics simultaneously inside multiple nanocapsules provides opportunities to investigate nanoscale processes such as single nanoparticle synthesis in confined volumes and biological processes such as biomineralization and membrane dynamics.

36 MATERIALS SCIENCE↗

Hanging drop sample preparation improves sensitivity of spatial proteomics

Spatial proteomics holds great promise for revealing tissue heterogeneity in both physiological and pathological conditions. However, one significant limitation of most spatial proteomics workflows is the requirement of large sample amounts that blurs cell-type-specific or microstructure-specific information. In this study, we developed an improved sample preparation approach for spatial proteomics and integrated it with our previously-established laser capture microdissection (LCM) and microfluidics sample processing platform. Specifically, we developed a hanging drop (HD) method to improve the sample recovery by positioning a nanowell chip upside-down during protein extraction and tryptic digestion steps. Compared with the commonly-used sitting-drop method, the HD method keeps the tissue pixel away from the container surface, and thus improves the accessibility of the extraction/digestion buffer to the tissue sample. The HD method can increase the MS signal by 7 fold, leading to a 66% increase in the number of identified proteins. An average of 721, 1489, and 2521 proteins can be quantitatively profiled from laser-dissected 10 μm-thick mouse liver tissue pixels with areas of 0.0025, 0.01, and 0.04 mm 2 , respectively. The improved system was further validated in the study of cell-type-specific proteomes of mouse uterine tissues.

47 OTHER INSTRUMENTATION↗

Hydrodynamics of a multicomponent vesicle under strong confinement

Herein we numerically investigate the hydrodynamics and membrane dynamics of a multicomponent vesicle in two strongly confined geometries. This serves as a simplified model for red blood cells undergoing large deformations while traversing narrow constrictions. We propose a new parameterization for the bending modulus that remains positive for all lipid phase parameter values. For a multicomponent vesicle passing through a stenosis, we establish connections between various properties: lipid phase coarsening, size and flow profile of the lubrication layers, excess pressure, and the tank-treading velocity of the membrane. For a multicomponent vesicle passing through a contracting channel, we find that the lipid always phase separates so that the vesicle is stiffer in the front as it passes through the constriction. For both cases of confinement we find that lipid coarsening is arrested under strong confinement, and resumes at a high rate upon relief from extreme confinement. The results may be useful for efficient sorting lipid domains using microfluidic flows by controlled release of vesicles passing through strong confinement.

97 MATHEMATICS AND COMPUTING↗

Quantitative local state of charge mapping by operando electrochemical fluorescence microscopy in porous electrodes

We introduce operando quantitative electrochemical fluorescence state of charge mapping (QEFSM), a non-invasive technique to study operating electrochemical systems along with a new design of optically transparent microfluidic redox flow cells compatible with the most demanding optical requirements. QEFSM allows quantitative mappings of the concentration of a particular oxidation state of a redox-active species within a porous electrode during its operation. In this study, we used confocal microscopy to map the fluorescence signal of the reduced form of 2,7-anthraquinone disulfonate (AQDS) in a set of multistep-chronoamperometry experiments. Calibrating these images and incorporating an analytical model of quinhydrone heterodimer formation with no free parameters, and accounting for the emission of each species involved, we determined the local molecular concentration and the state of charge (SOC) fields within a commercial porous electrode during operation. With this method, electrochemical conversion and species advection, reaction and diffusion can be monitored at heretofore unprecedented transverse and axial resolution (1 μm and 25 μm, respectively) at frame rates of 0.5 Hz, opening new routes to understanding local electrochemical processes in porous electrodes. Here, we observed pore-scale SOC inhomogeneities appearing when the fraction of electroactive species converted in a single pass through the electrode becomes large.

42 ENGINEERING↗

Enhanced reactivity at the oil–water interface accelerates the synthesis of zymonic acid in microemulsions

Chemical reactions in microscale compartments, such as aerosols and emulsions, can exhibit significantly faster reaction rates relative to macroscale containers. This enhancement in chemistry is often due to the elevated importance of surfaces as reaction vessels are reduced to picoliter volumes. While most studies have focused on the air-water interface of droplets, there are comparably fewer studies of reactions in micron-scale aqueous solutions encapsulated by oil. Here we investigate the condensation reaction of pyruvic acid (PA) to form zymonic acid (ZA) and water. Using microfluidics and optical trapping, chemical kinetics are measured in monodisperse micron-sized emulsion droplets in situ via Raman spectroscopy. Relative to a macroscopic bulk solution, which exhibits little to no reaction over many days, we find efficient production of ZA over the same time period. A kinetic model is developed to elucidate the role of the interface in accelerating the microdroplet reaction kinetics. After quantifying the surface partitioning of PA from interfacial tension measurements, the rate coefficient for the condensation reaction at the oil-water interface is determined to be 1.8 × 10-2 M-1 s-1. This rate coefficient is estimated to be 105 larger than the reaction rate in bulk aqueous solutions. Compared to previous studies of accelerated ZA formation at the air-water interface on nanodroplets, we find that the reaction at the oil-water interface is 20 times more efficient. Despite this difference, the overall ZA formation rate in emulsions is significantly slower than in the same-sized aerosols, which arises from the weaker partitioning of PA to the oil-aqueous relative to air-water interface. These results highlight the interplay between interfacial partitioning and reactivity in accelerating chemistry in microcompartments and provides new insights into how interfacial composition influences condensation reactions.

Wallace, Brandon J↗

Multi-layering of SU-8 exhibits distinct geometrical transitions from circular to planarized profiles

The negative tone photoresist SU-8 permits the creation of micrometer-scale structures by optical lithography. It is also the most used photoresist in soft lithography for the fast-prototyping of microfluidic devices. Despite its importance, the effect of capillary forces on SU-8 multi-layering onto topographical features has not been thoroughly studied. In particular, the profile of the added layer has not been examined in detail. The overlaying process exhibits a set of distinct behaviors, or regimes, depending on the relative thickness of the overlay and the underlying rectangular pattern. We demonstrate how capillary effects control the profile of multi-layer microchannels in a predictable manner. We derive a simple static model to describe the evolution of the overlay as a function of dimensionless geometric parameters. Our study provides a critical understanding of the parameters that govern multi-layer spin coating.

Sauzade, Martin↗

Ultrafast dynamics of CN radical reactions with chloroform solvent under vibrational strong coupling

Polariton chemistry may provide a new means to control molecular reactivity, permitting remote, reversible modification of reaction energetics, kinetics, and product yields. A considerable body of experimental and theoretical work has already demonstrated that strong coupling between a molecular vibrational mode and the confined electromagnetic field of an optical cavity can alter chemical reactivity without external illumination. However, the mechanisms underlying cavity-altered chemistry remain unclear in large part because the experimental systems examined previously are too complex for detailed analysis of their reaction dynamics. Here, we experimentally investigate photolysis-induced reactions of cyanide radicals with strongly-coupled chloroform (CHCl 3 ) solvent molecules and examine the intracavity rates of photofragment recombination, solvent complexation, and hydrogen abstraction. Here we use a microfluidic optical cavity fitted with dichroic mirrors to facilitate vibrational strong coupling (VSC) of the C–H stretching mode of CHCl 3 while simultaneously permitting optical access at visible wavelengths. Ultrafast transient absorption experiments performed with cavities tuned on- and off-resonance reveal that VSC of the CHCl 3 C–H stretching transition does not significantly modify any measured rate constants, including those associated with the hydrogen abstraction reaction. This work represents, to the best of our knowledge, the first experimental study of an elementary bimolecular reaction under VSC. We discuss how the conspicuous absence of cavity-altered effects in this system may provide insights into the mechanisms of modified ground state reactivity under VSC and help bridge the divide between experimental results and theoretical predictions in vibrational polariton chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dean vortex-enhanced blood plasma separation in self-driven spiral microchannel flow with cross-flow microfilters

Point-of-care (POC) diagnostic devices have been developing rapidly in recent years, but they are mainly using saliva instead of blood as a test sample. A highly efficient self-separation during the self-driven flow without power systems is desired for expanding the point-of-care diagnostic devices. Microfiltration stands out as a promising technique for blood plasma separation but faces limitations due to blood cell clogging, resulting in reduced separation speed and efficiency. These limitations are mainly caused by the high viscosity and hematocrit in the blood flow. A small increment in the hematocrit of the blood significantly increases the pressure needed for the blood plasma separation in the micro-filters and decreases the separation speed and efficiency. Addressing this challenge, this study explores the feasibility of diluting whole blood within a microfluidic device without external power systems. This study implemented a spiral microchannel utilizing the inertial focusing and Dean vortex effects to focus the red blood cells and extract the blood with lower hematocrit. The inertial migration of the particles during the capillary flow was first investigated experimentally; a maximum of 88% of the particles migrated to the bottom and top equilibrium positions in the optimized 350 × 60 μm (cross-sectional area, 5.8 aspect ratio) microchannel. With the optimized dimension of the microchannel, the whole blood samples within the physiological hematocrit range were tested in the experiments, and more than 10% of the hematocrit reduction was compared between the outer branch outlet and inner branch outlet in the 350 × 60 μm microchannel.

Biochemistry & Molecular Biology↗

Transferrin receptor targeting by de novo sheet extension

The de novo design of polar protein–protein interactions is challenging because of the thermodynamic cost of stripping water away from the polar groups. Here, we describe a general approach for designing proteins which complement exposed polar backbone groups at the edge of beta sheets with geometrically matched beta strands. We used this approach to computationally design small proteins that bind to an exposed beta sheet on the human transferrin receptor (hTfR), which shuttles interacting proteins across the blood–brain barrier (BBB), opening up avenues for drug delivery into the brain. We describe a design which binds hTfR with a 20 nM K d , is hyperstable, and crosses an in vitro microfluidic organ-on-a-chip model of the human BBB. Our design approach provides a general strategy for creating binders to protein targets with exposed surface beta edge strands.

59 BASIC BIOLOGICAL SCIENCES↗