Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microfluidics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Module-Fluidics: Building Blocks for Spatio-Temporal Microenvironment Control

Generating the desired solute concentration signal in micro-environments is vital to many applications ranging from micromixing to analyzing cellular response to a dynamic microenvironment. We propose a new modular design to generate targeted temporally varying concentration signals in microfluidic systems while minimizing perturbations to the flow field. The modularized design, here referred to as module-fluidics, similar in principle to interlocking toy bricks, is constructed from a combination of two building blocks and allows one to achieve versatility and flexibility in dynamically controlling input concentration. The building blocks are an oscillator and an integrator, and their combination enables the creation of controlled and complex concentration signals, with different user-defined time-scales. We show two basic connection patterns, in-series and in-parallel, to test the generation, integration, sampling and superposition of temporally-varying signals. All such signals can be fully characterized by analytic functions, in analogy with electric circuits, and allow one to perform design and optimization before fabrication. Such modularization offers a versatile and promising platform that allows one to create highly customizable time-dependent concentration inputs which can be targeted to the specific application of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated Label‐Free Assay for Viral Detection and Inhibitor Screening via Biomembrane‐Functionalized Microelectrode Arrays

Most virus infection assays have indirect readout such as virus number following entry (e.g., PCR, cell lysis). While effective, these technologies are labor‐intensive, require specialized environments (e.g., sterile or RNA‐free), and detect later‐stage viral events like lysis or cell death, lacking sensitivity to early fusion events. To address these limitations, we present biologically relevant 2D membrane materials, host‐cell‐derived supported lipid bilayers (hcd‐SLBs), integrated with organic microelectrode arrays (OMEAs) for detection of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) fusion. By overexpressing angiotensin‐converting enzyme 2 (ACE2) receptors on the native membranes, the platform functions as a viral sensor capable of detecting virus pseudo particles (VPPs) through the late pathway. Additionally, hcd‐SLBs extracted from human lung epithelium expressing native ACE2 detect fusion events through the early pathway. The platform's utility as a drug‐screening tool is demonstrated by testing antibodies targeting either the ACE2 on the host membrane or the viral spike (S) proteins. To enhance the throughput, microfluidics are integrated for automation and OMEAs are incorporated within each channel, miniaturizing the testing units. This system supports high‐throughput data generation, automation, and scalability, providing an efficient platform for viral fusion detection that advances the study of pathogen‐host interactions and accelerates antiviral drug discovery.

Biology↗

Current–Induced Ion Concentration Polarization at a Perfect Ion–Exchange Patch in an Infinite Insulating Wall

This research examines theoretically the ion concentration polarization, ion fluxes, and electrostatic fields near an ion exchange patch in the wall of an electrified fluidic channel. These phenomena are important in related microfluidic ion-preconcentration systems. Under an electric field, counterions enter the ion-exchange patch at one side and leave at the other, with salt depletion occurring near the entrance and accumulation near the exit. Furthermore, the high patch conductivity and the concentration profiles lead to local electric field perturbations that may facilitate preconcentration. This study includes analytical expressions of ion concentrations and electrochemical potentials at small to moderate electric fields, as well as numerical simulations. Additionally, a simple matrix of polynomial coefficients (obtained via fitting of numerical data) enables analytical calculation of the 2-dimensional concentration profiles at all electric fields within the range investigated in the numerical simulations. This is possible because a single dimensionless parameter controls this problem.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cation-Specific Electrokinetic Separations Using Prussian Blue Intercalation Reactions

In this work, we report a new approach for forming ion depletion zones (IDZs) using intercalation reactions at an electrochemically controlled Prussian blue (PB) film. The experiments described here were performed using a microfluidic device, wherein a charged fluorophore in solution was used as a proxy to monitor IDZ formation. In the presence of K + , intercalation reactions proceed readily to form an IDZ, and thus enrich the fluorophore up to 37-fold. In the presence of the larger hydrated Li + or tetrabutylammonium (TBA + ) ions, however, ion intercalation proceeded less quickly than with K + . Slower ion intercalation resulted in a weaker IDZ and correspondingly lower enrichment factors of eight- and six-fold, respectively. These results are significant because they show that PB intercalation reactions selectively form an IDZ. Accordingly, we anticipate that these findings will lead to a better understanding and further interesting applications of intercalation materials like PB for efficient and selective enrichment and separations.

99 GENERAL AND MISCELLANEOUS↗

Enriching Cations Using Electric Field Gradients Generated by Bipolar Electrodes in the Absence of Buffer

We discuss that ionic current gradients and corresponding electric field gradients formed at bipolar electrodes are useful for enriching cations up to ~350-fold at specific locations in microfluidic devices. The enrichment mechanism is determined by collecting current data, measuring solution conductivity, and by performing pH indicator experiments. These data reveal the dynamic nature of the enrichment mechanism. Specifically, they show the complex relationship between the ionic current gradients formed at the bipolar electrode and the extent of cation enrichment. Finally, we demonstrate cation enrichment is possible in buffer-free solutions containing up to 50.0 mM KCl. This finding is significant because it broadens the range of solutions in which membrane-free, electrochemical separations using bipolar electrodes can be performed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating inkjet dispenser/liquid vortex capture-mass spectrometry for single-cell metabolomics in Hep G2 steatosis caused by tamoxifen

Single-cell mass spectrometry (MS) is advancing our understanding of metabolic pathways in heterogeneous cell populations; however, many techniques are slow or require disruptive sample preparations. This study evaluated coupling a modified HP D100 single-cell inkjet dispenser with liquid vortex capture-mass spectrometry (D100/LVC-MS). The D100 is a single-cell inkjet dispenser capable of titrating solutions and isolating single cells via disposable cassettes equipped with microfluidic channels and an impedance sensor. The LVC-MS enables high-throughput capture, lysis, and ionization of analytes for mass spectrometric analysis. The D100/LVC-MS system was characterized through titration and single-cell experiments. Propranolol titration demonstrated linearity across a broad concentration range using the D100/LVC-MS system. Additionally, Hep G2 hepatocarcinoma cells and Chlamydomonas reinhardtii algae were used to showcase the D100’s high-throughput or low-buffer-volume single-cell dispensing strategies. The D100/LVC-MS system’s performance was validated by evaluating tamoxifen-induced steatosis in Hep G2 cells. Tamoxifen, associated with nonalcoholic fatty liver disease in breast cancer patients following long-term use, was tested in Hep G2 cells at 20 µM for 72 h against DMSO-treated controls. High-throughput analysis of 500 cells per condition, completed in 25 min per run, demonstrated the system’s efficiency. The D100/LVC-MS system simultaneously quantified tamoxifen and measured triglycerides and phosphatidylcholines. Triglycerides were upregulated in the tamoxifen-treated cells and the results indicated two distinct cell populations, differing in tamoxifen and phosphatidylcholines levels, suggesting heterogeneity within the treated population. In conclusion, these findings highlight the D100/LVC-MS system as a cost-effective, high-throughput platform for single-cell metabolomics and lipidomics, with significant potential for evaluating metabolic alterations.

Chromatography↗

On the competition between mixing rate and uniformity in a coaxial hydrodynamic focusing mixer

Fast microfluidic mixers for use with line-of-sight integrating detection schemes pose unique challenges. Such detectors typically cannot discriminate signal from slow moving (e.g. near internal walls) and fast-moving portions of the fluid stream. This convolves reaction rate dynamics with fluid flow residence time dynamics. Further, the small cross sections of typical three-dimensional hydrodynamic focusing devices lead to lower detection signals. The current study focuses on achieving both small time scales of mixing and homogenous residence times. This is achieved by injecting sample through a center capillary and hydrodynamically focusing using a sheath flow within a tapered second capillary. The current design also features a third, larger coaxial capillary. The mixed stream flows into the large cross-section of this third capillary to decelerate and expand the stream by up to 14-fold to improve line-of-sight signal strength of reaction products. Hydrodynamic focusing, mixing, and expansion are studied using analytical and numerical models and also studied experimentally using a fluorescein-iodide quenching reaction. The experimentally validated models are used to explore trade-offs between mixing rate and uniformity. For the first time, this work presents detailed analysis of the Lagrangian time history of species transport during mixing inside coaxial capillaries to measure mixing nonuniformity. The mixing region enables order 100 μs mixing times and residence time widths of the same order (140 μs).

42 ENGINEERING↗

Coupling between DNA replication, segregation, and the onset of constriction in Escherichia coli

Escherichia coli cell cycle features two critical cell-cycle checkpoints: initiation of replication and the onset of constriction. While the initiation of DNA replication has been extensively studied, it is less clear what triggers the onset of constriction and when exactly it occurs during the cell cycle. Here, using high-throughput fluorescence microscopy in microfluidic devices, we determine the timing for the onset of constriction relative to the replication cycle in different growth rates. Our single-cell data and modeling indicate that the initiation of constriction is coupled to replication-related processes in slow growth conditions. Furthermore, our data suggest that this coupling involves the mid-cell chromosome blocking the onset of constriction via some form of nucleoid occlusion occurring independently of SlmA and the Ter linkage proteins. This work highlights the coupling between replication and division cycles and brings up a new nucleoid mediated control mechanism in E. coli.

59 BASIC BIOLOGICAL SCIENCES↗

Insight into industrial hemp ( Cannabis sativa L.) root exudation composition in a simulated soil environment: a rhizosphere-on-a-chip study

Microfluidic technologies provide a reduced complexity and soil-free environment to study plant-soil interactions at the microscale. Traditionally used for model plants such as Arabidopsis thaliana, this study represents the first application of a rhizosphere-on-a-chip (RhizoChip) to investigate root exudation in industrial hemp (Cannabis sativa L.), an agronomic crop with growing economic importance. By incorporating soil-like minerals (kaolinite, potassium feldspar, and biotite), the RhizoChip addresses limitations of previous research. Hemp seedlings grown in mineral-containing chips exhibited significant root growth, emphasizing the critical role of minerals in root development. Using untargeted metabolomics, 170 compounds were identified, including organic acids, amino acids, and secondary metabolites, with distinct profiles across conditions. Metabolic pathway analysis revealed activity in amino acid metabolism, the citric acid cycle, and secondary metabolite biosynthesis. In conclusion, this study highlights the RhizoChip's potential for long-term studies of root exudates in non-model crops and offers insights into rhizosphere processes with implications for sustainable agriculture.

59 BASIC BIOLOGICAL SCIENCES↗

Acoustic focusing of microplastics in microfabricated and steel tube devices: An experimental study on the effects from particle size and medium density

The contamination of aquatic systems with microplastics is becoming a severe threat to living organisms. Microplastics found in the environment consist of a wide range of particle sizes thus give rise to several challenges to current purification methods. Acoustic focusing has been utilized as a particle concentrating method in biological and non-biological applications. In this study, we investigate the feasibility of using acoustic focusing technology to isolate microplastics in aqueous samples and find that a two-stage mechanism is essential to concentrate microplastics of wide size ranges of the same material. We demonstrate for the first time experimentally that when the particle size is comparable to the resonance wavelength, they deviate from typical pressure nodal focusing and show pressure antinodal focusing. Further, we have expanded microplastics isolation beyond microfluidic systems and demonstrate their extraction capabilities relatively at higher flow rates using microplastics of polystyrene, polyethylene, and polymethyl methacrylate ranging from 6 µm to 300 µm diameter and in devices fabricated with cylindrical steel tubes. We could extract 70% of microplastics smaller than 180 µm and 82% of microplastics greater than 180 µm in diameter from an aqueous sample at a flow rate of 12 mL/min. In conclusion, we demonstrate that small microplastics focus on acoustic pressure nodes regardless of the medium density. However, focusing of large microplastics of the same material depends on the medium density.

42 ENGINEERING↗

Brain-implantable multifunctional probe for simultaneous detection of glutamate and GABA neurotransmitters

We report Glutamate (GLU) and gamma-aminobutyric acid (GABA) are neurotransmitters (NTs) with an essential role in signal transmission in the brain. Brain disorders, such as epilepsy, Alzheimer's and Parkinson's diseases, and traumatic brain injury can be linked to imbalances in the GLU-GABA homeostasis that occurs in sub-second to seconds time frames. Current measurement techniques can detect these two NT concentrations simultaneously only in vitro. The present work reports on the fabrication of a silicon multifunctional biosensor microarray probe for sub-second simultaneous GLU-GABA detection in real-time, with excellent analyte sensitivity and selectivity and in vivo capabilities. The novel Si probes feature four surface-functionalized platinum ultramicroelectrodes (UMEs) for simultaneous amperometric detection of GLU and GABA with a sentinel, and a built-in microfluidic channel for the introduction of neurochemicals in the proximity of the UMEs. The microchannel also allows functioning of an On-Demand In-situ Calibrator that runs in-situ biosensor calibration. The probe exhibited excellent robustness at insertion in agarose-gel brain-tissue-mimicking test, and remarkably high hydrogen peroxide sensitivity (a by-product of GLU-GABA enzyme biosensor) with values on the order of 5000 nA μM -1 cm -2 and maximum sensitivities of 204 ± 15 nA μM -1 cm -2 and 37 ± 7 nA μM -1 cm -2 for GLU and GABA, respectively. Furthermore, the limit of detection of the biosensors reached as low as 7 nM, 165 nM and 750 nM for H 2 O 2 , GLU and GABA, respectively and a temporal resolution of hundreds of milliseconds during in vivo studies using freely moving rats.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dissolution of a cylindrical disk in Hele-Shaw flow: a conformal-mapping approach

Here we apply conformal mapping to find the evolving shapes of a dissolving cylinder in a potential flow. Similar equations can be used to describe melting in a flowing liquid phase. Results are compared with microfluidic experiments and numerical simulations. Shapes predicted by conformal mapping agree almost perfectly with experimental observations, after a modest (20 %) rescaling of the time. Finite-volume simulations show that the differences with experiment are connected to the underlying assumptions of the analytical model: potential flow and diffusion-limited dissolution. Approximate solutions of the equations describing the evolution of the shape of the undissolved solid can be derived from a Laurent expansion of the mapping function from the unit circle. Asymptotic expressions for the evolution of the area of the disk and the shift in its centre of mass have been derived at low and high Péclet number. Analytic approximations to the leading-order Laurent coefficients provide additional insight into the mechanisms underlying pore-scale dissolution.

58 GEOSCIENCES↗

In Situ Detection of Amino Acids from Bacterial Biofilms and Plant Root Exudates by Liquid Microjunction Surface-Sampling Probe Mass Spectrometry

The plant rhizosphere is a complex and dynamic chemical environment where the exchange of molecular signals between plants, microbes, and fungi drives the development of the entire biological system. Exogenous compounds in the rhizosphere are known to affect plant-microbe organization, interactions between organisms, and ultimately, growth and survivability. The function of exogenous compounds in the rhizosphere is still under much investigation, specifically with respect to their roles in plant growth and development, the assembly of the associated microbial community, and the spatiotemporal distribution of molecular components. A major challenge for spatiotemporal measurements is developing a nondisruptive and nondestructive technique capable of analyzing the exogenous compounds contained within the environment. A methodology using liquid microjunction-surface sampling probe-mass spectrometry (LMJ-SSP-MS) and microfluidic devices with attached microporous membranes was developed for in situ, spatiotemporal measurement of amino acids (AAs) from bacterial biofilms and plant roots. Exuded arginine was measured from a living Pantoea YR 343 biofilm, which resulted in a chemical image indicative of biofilm growth within the device. Spot sampling along the roots of Populus trichocarpa with the LMJ-SSP-MS resulted in the detection of 15 AAs. Of note, variation in AA concentrations across the root system was observed, indicating that exudation is not homogeneous and may be linked to local rhizosphere architecture and different biological processes along the root.

59 BASIC BIOLOGICAL SCIENCES↗

Low cost and massively parallel force spectroscopy with fluid loading on a chip

Current approaches for single molecule force spectroscopy are typically constrained by low throughput and high instrumentation cost. Herein, a low-cost, high throughput technique is demonstrated using microfluidics for multiplexed mechanical manipulation of up to ~4000 individual molecules via molecular fluid loading on-a-chip (FLO-Chip). The FLO-Chip consists of serially connected microchannels with varying width, allowing for simultaneous testing at multiple loading rates. Molecular force measurements are demonstrated by dissociating Biotin-Streptavidin and Digoxigenin-AntiDigoxigenin interactions along with unzipping of double stranded DNA of varying sequence under different dynamic loading rates and solution conditions. Rupture force results under varying loading rates and solution conditions are in good agreement with prior studies, verifying a versatile approach for single molecule biophysics and molecular mechanobiology. FLO-Chip enables straightforward, rapid, low-cost, and portable mechanical testing of single molecules that can be implemented on a wide range of microscopes to broaden access and may enable new applications of molecular force spectroscopy.

42 ENGINEERING↗

Continuous flow photochemical synthesis of metal–ceramic composite microparticles

We developed a UV-assisted microfluidic system to synthesize FeCrAl–Al 2 O 3 composite microparticles for additive manufacturing. Here, the system ensures precise particle size, morphology, and elemental distribution control. Increasing the dispensing pressure while keeping the oil flow rate constant resulted in larger microparticles. Laser fusing revealed FeCrAl and Al 2 O 3 phases, showing their potential as feedstocks for 3D printed heterogeneous materials such as FeCrAl/Al 2 O 3 bi-phase materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational study of inertial migration of prolate particles in a straight rectangular channel

Inertial migration of spherical particles has been investigated extensively using experiments, theory, and computational modeling. Yet, a systematic investigation of the effect of particle shape on inertial migration is still lacking. Herein, we numerically mapped the migration dynamics of a prolate particle in a straight rectangular microchannel using smoothed particle hydrodynamics at moderate Reynolds number flows. After validation, we applied our model to 2:1 and 3:1 shape aspect ratio particles at multiple confinement ratios. Their effects on the final focusing position, rotational behavior, and transitional dynamics were studied. In addition to the commonly reported tumbling motion, for the first time, we identified a new logrolling behavior of a prolate ellipsoidal particle in the confined channel. This new behavior occurs when the confinement ratio is above an approximate threshold value of K = 0.72. Our microfluidic experiments using cell aggregates with similar shape aspect ratio and confinement ratio confirmed this new predicted logrolling motion. In this study, we also found that the same particle can undergo different rotational modes, including kayaking behavior, depending on its initial cross-sectional position and orientation. Furthermore, we examined the migration speed, angular velocity, and rotation period as well as their dependence on both particle shape aspect ratio and confinement ratio. Our findings are especially relevant to the applications where particle shape and alignment are used for sorting and analysis, such as the use of barcoded particles for biochemical assays through optical reading, or the shape-based enrichment of microalgae, bacteria, and chromosomes.

42 ENGINEERING↗

Replenishing liquid sheet targets to enable high-intensity high-repetition-rate laser–plasma interactions for ion-beam technology

We report on the development of a robust microfluidic nozzle capable of generating replenishing liquid sheet targets with sub-micron thickness at up to kHz repetition rates, a λ/20 surface flatness over areas of at least 100 μm 2 , and in-vacuum dimensions of 6 × 1.5 mm 2 . The platform was evaluated for stability under hundreds of 4.3 J laser shots at 0.5 Hz and 6 × 10 20 W/cm 2 peak intensity, delivered in burst mode, totaling 2.9 kJ on the target. The key metrics of the platform, including sheet characteristics, nozzle aperture morphology, and proton spectra, showed no measurable degradation in the performance of the liquid sheet platform following this experiment. Beyond its application to ion beam technology, we outline a pathway to further develop the capabilities of the platform into a high-repetition-rate plasma mirror.

depth profiling techniques↗

Scale-dependent tipping points of bacterial colonization resistance

The commonly observed stability of natural microbiomes is important for their function, yet the ubiquity of microbiome stability remains enigmatic. The strongest form of stability, colonization resistance, protects residents against invaders and is often associated with specific porous structures, such as skin follicles or intestinal crypts. By systematically probing the colonization of fly gut–derived bacteria in microfluidic pores of varying sizes, we revealed that colonization patterns and invasion rates strongly depend on the pore size. Mathematical modeling shows that bacteria spontaneously tend to organize into a dense colonization-resistant state in pores exceeding a critical size. The scale dependence of stability and resilience could bias ecological filtering in microbiomes and should be considered in the design of microbial ecology experiments.

59 BASIC BIOLOGICAL SCIENCES↗