The Surveyor television camera as a scientific instrument
Surveyor TV camera conversion from qualitative viewing device into quantitative measuring instrument by calibration coupled with data processing program
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Surveyor TV camera conversion from qualitative viewing device into quantitative measuring instrument by calibration coupled with data processing program
Two tape products from the Total Ozone Mapping Spectrometer (TOMS) aboard the Nimbus-7 have been archived at the National Space Science Data Center. The instrument measures backscattered Earth radiance and incoming solar irradiance; their ratio -- the albedo -- is used in ozone retrievals. In-flight measurements are used to monitor changes in the instrument sensitivity. The algorithm to retrieve total column ozone compares the observed ratios of albedos at pairs of wavelengths with pair ratios calculated for different ozone values, solar zenith angles, and optical paths. The initial error in the absolute scale for TOMS total ozone is 3 percent, the one standard-deviation random error is 2 percent, and the drift is +/- 1.5 percent over 14.5 years. The High Density TOMS (HDTOMS) tape contains the measured albedos, the derived total ozone amount, reflectivity, and cloud-height information for each scan position. It also contains an index of SO2 contamination for each position. The Gridded TOMS (GRIDTOMS) tape contains daily total ozone and reflectivity in roughly equal area grids (110 km in latitude by about 100-150 km in longitude). Detailed descriptions of the tape structure and record formats are provided.
The measurements of the solar ultraviolet spectral irradiance by the two Upper Atmosphere Research Satellite (UARS) solar instruments are validated to agree within their 2-Sigma calibration uncertainties of about 7 percent, as well as with measurements from the two solar instruments on the Shuttle Atmospheric Laboratory for Applications and Science (ATLAS) missions. Additionally, the precision of the two UARS data sets is better than the original 2 percent goal, especially at wavelengths greater than 160 nm. This excellent agreement can be credited to accurate pre-flight calibrations, comprehensive in-flight calibrations to track instrument degradation, and a coordinated validation program among the UARS and ATLAS solar instrument teams. The solar irradiance results presented here include those derived from UARS SUSIM, UARS SOLSTICE, ATLAS SUSIM and ATLAS SSBUV measurements on 29 March 1992 during the ATLAS-1 mission and on 15 April 1993 during the ATLAS-2 mission. Two ultraviolet spectra from 119 to 410 nm are derived as the weighted average of the UARS SOLSTICE and SUSIM measurements and are recommended as representative solar spectra for the period of the ATLAS-1 and ATLAS-2 missions. The ATLAS-1 mission occurred during the initial phase of the solar cycle 22 decline when solar activity was moderately high. The ATLAS-2 mission occurred later during the declining phase of the solar cycle 22 when solar activity was more moderate.
Stratospheric ozone occurs naturally in the upper atmosphere, forming a protective layer that shields us from the sun's harmful ultraviolet rays. Tropospheric ozone is not emitted directly into the air but is created by chemical reactions between nitrogen oxides (NOx) and volatile organic compounds (VOC). This reaction happens when pollutants emitted by cars, power plants, industrial boilers, refineries, chemical plants, and other sources chemically react in sunlight [1]. Therefore, increased levels of tropospheric ozone indicate the presence of pollutants in the air. While daily anthropogenic activity causes an increase of ground-level ozone, variation of stratospheric ozone changes happens much slower, so that variation of the total ozone column reflects the variation of the tropospheric column due to natural, e.g., wildfires and anthropogenic air pollution. Both total and tropospheric ozone column products are used in this study. The reflectance spectra measured by the Earth Polychromatic Imaging Camera (EPIC) instrument aboard the Deep Space Climate Observatory (DSCOVR) spacecraft are compared with a set of radiative transfer-derived lookup tables for the EPIC filter transmission functions and a wide range of ozone values to retrieve ozone with a maximum resolution of 18 km at the sub-satellite point [2]. EPIC provides total column ozone in level 2 and level 4 products and tropospheric column ozone in level 4 products. Both EPIC Ozone products [2] are available at the Atmospheric Science Data Center (ASDC) at NASA Langley Research Center [3, 4]. Pandora spectrometer instrument measures columnar amounts of trace gases in the atmosphere. These gases (O3, NO2, CH2O) absorb light from the sun at specific wavelengths in the ultraviolet-visible spectrum [5]. Using the theoretical solar spectrum as a reference, Pandora determines trace gas amounts using differential optical absorption spectroscopy (DOAS). Pandora ozone retrievals are available from the Pandonia Global Network [6]. Pandora data from North American major metropolitan areas, New York, NY, Washington DC, Los Angeles, CA, and Mexico City. Tropospheric Ozone Lidar Network (TOLNet) was established in 2012 to provide high spatiotemporal observations of tropospheric ozone to (1) better understand physical processes driving the ozone budget in various meteorological and environmental conditions and (2) validate the tropospheric ozone measurements of space-borne missions [7]. TOLNet data are available at ASDC [8]. While EPIC provides global coverage of ozone retrievals several times daily, temporal resolution may miss some features in daily ozone variations. Ground-based sensors such as Pandora spectrometers and TOLNet lidars provide better temporal resolution while missing continuous spatial coverage. The forthcoming ozone retrieval from the TEMPO mission [9] will provide better spatial and temporal coverage of air quality (including ozone) over North America. This study investigates whether EPIC ozone products can detect diurnal air quality variations and compare ozone temporal development with retrieval by ground-based instruments.
Emerging photovoltaic (PV) technologies (e.g., organic, perovskite, and solution processed quantum dot) have attracted remarkable attention with the rapid growth of their efficiencies, and their transition toward commercialization. Accurate and reliable efficiency measurements of these PV technologies are crucial, yet much more complicated than for conventional PV technologies due to the former's pronounced dynamic responses to changes in measurement conditions (e.g., current–voltage (I–V) scan rate and preconditioning) and their susceptibility to degradation. Adjustments to the measurement procedures are therefore necessary so that a reproducible “steady state” is reached during measurement. Furthermore, given the small size of many emerging cells, inappropriate device area definition and solar simulator setup can lead to measurement errors. Here, comprehensive efficiency calibration guidance is offered for emerging solar cells, including area measurement; spectral irradiance translation to standard test conditions; and steady-state electrical performance. The necessity of reporting steady-state efficiency is justified with a statistical performance comparison between conventional and steady-state I–V scans over hundreds of cells the group has received globally for efficiency certifications. The procedures described here do not require specialized measurement instrumentation; what matters most are changes to the measurement protocols. These described changes aim to enable better comparisons between reported efficiencies.
This dataset includes guest instrument measurements and other PI products for aerosol microphysics and chemical measurements collected at Mt. Soledad and Scripps Pier during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) from February 2023 to February 2024. The measurements include the following instruments at Mt. Soledad: High-Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS, Aerodyne), Scanning Electrical Mobility Spectrometer (SEMS, Brechtel Manufacturing Inc.), Aerodynamic Particle Sizer (APS, Droplet Measurements Technologies), Single Particle Soot Photometer (SP2, Drople Measurements Technologies), Meteorological Station (WXT520, Vaisala), Ozone (Teco), and trace gas proxies (Teledyne). In addition, the analyses of particle filters collected at Mt. Soledad for three dry-diameter size cuts (<1 micron, <0.5 micron, <0.18 micron) and at Scripps Pier for one dry-diameter size cut (<1 micron) by Fourier Transform Infrared (FTIR) and X-ray Fluorescence (XRF) are reported. A differential mobility analyzer operated as a scanning mobility particle sizer (SMPS, TSI Inc.), a printed particle optical spectrometer (POPS, Grimm), and a continuous flow diffusion cloud condensation nuclei (CCN, DMT) counter provide the mobility aerosol size distribution (30-360 nm), optical size distribution (150 - 6000 nm), size-resolved CCN distribution (30-360 nm) at 0.2, 0.4, 0.6, 0.8, and 1.0% supersaturation. Measurements are reported for both sampling from an isokinetic aerosol inlet and from a Counterflow Virtual Impactor (CVI, Brechtel Manufacturing Inc.). The data are available at the following link: https://library.ucsd.edu/dc/collection/bb0898306q
Combustion deposits reduce transfer of heat. Instrument measures fouling like that on gas side of heat exchanger in direct-fired boiler or heat-recovery system. Heat-flux probe includes tube with embedded meter in outer shell. Combustion gases flow over probe, and fouling accumulates on it, just as fouling would on heat exchanger. Embedded heat-flow meter is sandwich structure in which thin Chromel layers and middle alloy form thermopile. Users determine when fouling approaches unacceptable levels so they schedule cleaning and avoid decreased transfer of heat and increased drop in pressure fouling causes. Avoids cost of premature, unnecessary maintenance.
An improved instrument for optical absorption spectroscopy utilizes off-axis paths in an optical cavity in order to increase detection sensitivity while suppressing resonance effects. The instrument is well suited for use in either cavity ring-down spectroscopy (CRDS) [in which one pulses an incident light beam and measures the rate of decay of light in the cavity] or integrated cavity output spectroscopy (ICOS) [in which one uses a continuous-wave incident light beam and measures the power of light in the cavity as a function of wavelength]. Typically, in optical absorption spectroscopy, one seeks to measure absorption of a beam of light in a substance (usually a gas or liquid) in a sample cell. In CRDS or ICOS, the sample cell is placed in (or consists of) an optical cavity, so that one can utilize multiple reflections of the beam to increase the effective optical path length through the absorbing substance and thereby increase the sensitivity for measuring absorption. If an absorbing substance is not present in the optical cavity, one can utilize the multiple passes of the light beam to increase the sensitivity for measuring absorption and scattering by components of the optical cavity itself. It is desirable to suppress the effects of resonances in the cavity in order to make the spectral response of the cavity itself as nearly constant as possible over the entire wavelength range of interest. In the present instrument, the desired flattening of the spectral response is accomplished by utilizing an off-axis beam geometry to effectively decrease the frequency interval between longitudinal electromagnetic modes of the cavity, such that the resulting transmission spectrum of the cavity is nearly continuous: in other words, the cavity becomes a broad-band optical device.
Electrostatic analyzing instrument for measurement of charged particles in aurora
Abstract. The third phase of the Fifth International Ice Nucleation Workshop (FIN-03) was conducted at the Storm Peak Laboratory in Steamboat Springs, Colorado, in September 2015 to facilitate the intercomparison of instruments measuring ice-nucleating particles (INPs) in the field. Instruments included two online and four offline measurement systems for INPs, which are a subset of those utilized in the laboratory study that comprised the second phase of FIN (FIN-02). The composition of the total aerosols was characterized using the Particle Analysis by Laser Mass Spectrometry (PALMS) and Wideband Integrated Bioaerosol Sensor (WIBS) instruments, and aerosol size distributions were measured by a laser aerosol spectrometer (LAS). The dominant total particle compositions present during FIN-03 were composed of sulfates, organic compounds, and nitrates, as well as particles derived from biomass burning. Mineral-dust-containing particles were ubiquitous throughout and represented 67 % of supermicron particles. Total WIBS fluorescing particle concentrations for particles with diameters of > 0.5 µm were 0.04 ± 0.02 cm−3 (0.1 cm−3 highest; 0.02 cm−3 lowest), typical of the warm season in this region and representing ≈ 9 % of all particles in this size range as a campaign average. The primary focus of FIN-03 was the measurement of INP concentrations via immersion freezing at temperatures > −33 °C. Additionally, some measurements were made in the deposition nucleation regime at these same temperatures, representing one of the first efforts to include both mechanisms within a field campaign. INP concentrations via immersion freezing agreed within factors ranging from nearly 1 to 5 times on average between matched (time and temperature) measurements, and disagreements only rarely exceeded 1 order of magnitude for sampling times coordinated to within 3 h. Comparisons were restricted to temperatures lower than −15 °C due to the limits of detection related to sample volumes and very low INP concentrations. Outliers of up to 2 orders of magnitude occurred between −25 and −18 °C; a better agreement was seen at higher and lower temperatures. Although the 5–10 factor agreement of INP measurements found in FIN-03 aligned with the results of the FIN-02 laboratory comparison phase, giving confidence in progress of this measurement field, this level of agreement still equates to temperature uncertainties of 3.5 to 5 °C that may not be sufficient for numerical cloud modeling applications that utilize INP information. INP activity in the immersion-freezing mode was generally found to be an order of magnitude or more, making it more efficient than in the deposition regime at 95 %–99 % water relative humidity, although this limited data set should be augmented in future efforts. To contextualize the study results, an assessment was made of the composition of INPs during the late-summer to early-fall period of this study inferred through comparison to existing ice nucleation parameterizations and through measurement of the influence of thermal and organic carbon digestion treatments on immersion-freezing ice nucleation activity. Consistent with other studies in continental regions, biological INPs dominated at temperatures of > −20 °C and sometimes colder, while arable dust-like or other organic-influenced INPs were inferred to dominate below −20 °C.
Electrically actuated shutter designed to operate many thousands of time at cryogenic temperatures. Open shutter allows light at wavelenghts between 1 and 300 micrometers to enter instrument measures background cosmic radiation. Closed shutter blocks outside radiation from instrument and positions mirror to reflect light from internal source to instrument calibrated. Designed, if power failure occurs, shutter remains in or assumes open position so measurements continue without calibration.
The ROCOZ-A radiometer measures ozone by long pathlength photometry in the stratosphere and lower mesosphere. After a rocket launch to an apogee of 70 km, the instrument measures the solar ultraviolet irradiance over its four filter wavelengths as it descends on a parachute. The fundamental values from ROCOZ-A are ozone overburdens versus radar altitude from 53 to 20 km. The slope of these values gives ozone number density. At one standard deviation the repeatability of the ozone overburden measurements averages 2.4 percent. For ozone number density the repeatability averages 3.2 percent with a significant increase at altitudes below the ozone number density maximum. The accuracy limits for overburden and number density are estimated at 5-7 percent. With auxiliary measurements of pressure and temperature, ozone results are also produced in terms of ozone mixing ratio, albeit with a slight broadening of the estimated accuracy limits. The vertical response of ROCOZ-A ozone measurements (full width at half maximum) is 4 km. The assembly of ROCOZ-A profiles can be used to compare with measurements from each of the current NASA and NOAA satellite ozone instruments. In addition, the repeatability of ROCOZ-A allows the use of this instrument as a transfer standard between satellite instruments with different fundamental ozone measurements.
The OMPS Limb Profiling (LP) instrument was launched on NOAA's Suomi NPP (SNPP) weather satellite in October 2011. The instrument measures limb-scattered radiation in the ultraviolet, visible and NIR wavelengths with high vertical resolution (~2 km) and relatively dense spatial and temporal sampling (several thousand measurements/day covering the entire sunlit globe). These measurements have very high sensitivity to stratospheric aerosols due to long path of the incoming solar photons through the aerosol layer. However, unlike the recently launched ISS/SAGE III that directly measures extinction of solar/lunar radiation by gases and particles along the line of sight (LOS) of the instrument, information content of OMPS LP measurements is complex. It consists of solar radiation singly scattered and attenuated by aerosols, air, and trace gases along the LOS of the instrument, as well as diffuse upwelling radiation from the lower atmosphere that also gets scattered and attenuated into the LOS. To unscramble this complex signal one needs to have good knowledge of aerosol size distribution (ASD) and their complex refractive index. We will describe our recent efforts in constraining the ASD parameters by analyzing in-situ balloon data from Laramie, Wyoming; aerosol microphysical model data from CARMA; and spectral information provided by OMPS LP. We will also discuss our proposed methodology to reï¬ne this information by adjusting the microphysical properties of the aerosols to make data from various occultation and scattering instruments internally consistent. This is a generalized version of the technique employed by AERONET in which solar extinction data are combined with scattered radiation measured by the almucantar technique to determine aerosol particle shape, complex refractive index and size distribution. We suggest that such closure studies are essential to develop confidence in space-based data to validate aerosol microphysical models, such as CARMA, and aerosol chemistry- transport models, such as GOCART, and for estimating radiative forcing due to stratospheric aerosols in both volcanic and quiescent time periods.
A new velocity measurement instrument for luminous flows was developed by Science Research Laboratory for NASA. The SIEVE (Segmented Image Emission VElocimeter) instrument uses broadband light emitted by the flow for the velocity measurement. This differs from other velocimetry techniques in that it does not depend on laser illumination and/or light scattering from particles in the flow. The SIEVE is a passive, non-intrusive diagnostic. By moving and adjusting the imaging optics, the SIEVE can provide three-dimensional mapping of a flow field and determine turbulence scale size. A SIEVE instrument was demonstrated on an illuminated rotating disk to evaluate instrument response and noise and on an oxy-acetylene torch to measure flame velocities. The luminous flow in rocket combustors and plumes is an ideal subject for the SIEVE velocity measurement technique.
Experimental characterization of the antenna for the Wideband Instrument for Snow Measurements (WISM) under development for the NASA Earth Science Technology Office (ESTO) Instrument Incubator Program (IIP), is discussed. A current sheet antenna, consisting of a small, 6x6 element, dual-linear polarized array with integrated beamformer, feeds an offset parabolic reflector, enabling WISM operation over an 8 to 40 GHz frequency band. An overview of the test program implemented for both the feed and the reflector antenna is given along with select results for specific frequencies utilized by the radar and radiometric sensors of the WISM.
Doppler-radar instrument measures small deflections or vibrations of reflecting surface. Acting as interferometric micrometer, instrument includes combination of analog and digital circuits measuring change in phase of radar return due to movement of reflecting surface along signal-propagation path. Includes homodyne Doppler-radar transceiver and digital signal-processing circuitry to measure change in phase shift as target deflects.
Bolts instrumented with strain gauges used to measure shear forces. Bolts installed in multiple-bolt lap joints to obtain data on distribution of stresses and deformations in and around joints. Strain gauges indicate share of applied load borne by each individual bolt. In original application, bolted panels made of advanced refractory composite materials designed to withstand use at temperatures up to 4,000 degrees F. Also applicable to other joint materials and measurement of shear loads in other connections such as, shear loads on shafts in pulleys or gears.
Mars Pathfinder's Accelerometer instrument measured an unexpected and large temperature inversion between 10 and 20 kilometer altitude. Other instruments have failed to detect similar temperature inversions. I test whether this inversion is real or not by examining what changes have to be made to the assumptions in the accelerometer data processing to obtain a more "expected" temperature profile. Changes in derived temperature of up to 30K, or 15%, are necessary, which correspond to changes in derived density of up to 25% and changes in derived pressure of up to 10%. If the drag coefficient is changed to satisfy this, then instead of decreasing from 1.6 to 1.4 from 20 kilometers to 10 kilometers, the drag coefficient must increase from 1.6 to 1.8 instead. If winds are invoked, then speeds of 60 meters per second are necessary, four times greater than those predicted. Refinements to the equation of hydrostatic equilibrium modify the temperature profile by an order of magnitude less than the desired amount. Unrealistically large instrument drifts of 0.5-1.0 meters per square second are needed to adjust the temperature profile as desired. However, rotational contributions to the accelerations may have the necessary magnitude and direction to make this correction. Determining whether this hypothesis is true will require further study of the rigid body equations of motion, with detailed knowledge of the positions of all six accelerometers. The paradox concerning this inversion is not yet resolved. It is important to resolve it because the paradox has some startling implications. At one extreme, are temperature profiles derived from accelerometers inherently inaccurate by 20K or more? At the other extreme, are RS temperature profiles inaccurate by this same amount?