Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement_method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Nonlinear processes upon two-photon interband picosecond excitation of PbWO{sub 4} crystal

A new experimental method is proposed to study the dynamics of nonlinear processes occurring upon two-photon interband picosecond excitation of a lead tungstate crystal and upon its excitation by cw probe radiation in a temporal range from several nanoseconds to several seconds. The method is applied to the case of crystal excitation by a sequence of 25 high-power picosecond pulses with a wavelength of 523.5 nm and 633-nm cw probe radiation. Measuring the probe beam transmittance during crystal excitation, one can investigate the influence of two-photon interband absorption and the thermal nonlinearity of the refractive index on the dynamics of nonlinear processes in a wide range of times (from several nanoseconds to several seconds). The time resolution of the measuring system makes it possible to distinguish fast and slow nonlinear processes of electronic or thermal nature, including the generation of a thermal lens and thermal diffusion. An alternative method is proposed to study the dynamics of induced absorption transformation and, therefore, the dynamics of the development of nonlinear rocesses upon degenerate two-photon excitation of the crystal in the absence of external probe radiation. (nonlinear-optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method of measuring blood oxygenation based on spectroscopy of diffusely scattered light

A new approach to the measurement of blood oxygenation is developed and implemented, based on an original two-step algorithm reconstructing the relative concentration of biological chromophores (haemoglobin, water, lipids) from the measured spectra of diffusely scattered light at different distances from the radiation source. The numerical experiments and approbation of the proposed approach using a biological phantom have shown the high accuracy of the reconstruction of optical properties of the object in question, as well as the possibility of correct calculation of the haemoglobin oxygenation in the presence of additive noises without calibration of the measuring device. The results of the experimental studies in animals agree with the previously published results obtained by other research groups and demonstrate the possibility of applying the developed method to the monitoring of blood oxygenation in tumour tissues. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of an image jitter of an extended incoherent radiation source

A scheme of an image jitter measuring device, which uses an extended incoherent source as a radiation source, is presented. The efficiency of the measuring device is analysed analytically and numerically in order to justify the operation of the adaptive optical system that does not require special creation or formation of a reference source. The features of the formed image of incoherent radiation are considered, in particular from the point of view of its possible application for measuring the phase fluctuations of optical waves propagating in a turbulent atmosphere (the adaptive system monitors the image of a self-luminous object illuminated by extraneous sources). The possibility of utilising a Shack – Hartmann wavefront sensor in adaptive systems using the image of an arbitrary object (or its fragment) as a reference source is shown. (optical images)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A simple method of measuring the effective SRS coefficient in single-mode optical fibres and its applicability limits

This paper describes techniques for measuring the SRS coefficient in a wide spectral range, including the region of small Stokes shifts. A simple, approximate method is proposed for evaluating the SRS coefficient near a gain peak. Spectral dependences of the SRS coefficient are presented for various telecom fibres. (nonlinear optical phenomena)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon echo of an ultranarrow optical transition of {sup 167}Er{sup 3+} in {sup 7}LiYF{sub 4} crystals

The longitudinal and transverse relaxation times for a transition between hyperfine sublevels of the lower electronic states of the {sup 4}I{sub 15/2} and {sup 4}I{sub 9/2} multiplets of {sup 167}Er{sup 3+} ions in {sup 7}LiYF{sub 4} crystals have been determined for the first time using two-pulse and stimulated photon echo measurements in zero magnetic field at a temperature of 4 K. The decay of the photon echo signal has been shown to be modulated, which is tentatively attributed to the superhyperfine interaction of the {sup 167}Er{sup 3+} ions with their {sup 19}F{sup −} nearest neighbours. The contributions of various types of interaction to the ultranarrow linewidth (∼24 MHz) of the transition in question are discussed. Our results demonstrate that this optical transition of the {sup 167}Er{sup 3+} ion in {sup 7}LiYF{sub 4} crystals is potentially attractive for use in Raman quantum memory schemes. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An improved method for quantitatively measuring antifouling coating performance using a mussel single thread tensile adhesion test

Surface biofouling reduces the efficiency and lifespan of equipment across many industries. The development of high-performance antifouling surfaces, such as foul release coatings, benefits from test methods that can quickly identify superior antifouling surfaces in the laboratory during material development. Existing test methods poorly discriminate between different foul release coatings. Here is presented a method to assess the ability of surfaces to resist mussel adhesion using a quantitative, controlled single thread adhesion test (STAT) method, allowing for meaningful comparisons between low adhesion foul release surfaces. This method provides greater accuracy and finer resolution than push-based mussel shear adhesion methods without the difficulties associated with mussel size, thread attachment angle, or harming the mussels. The single thread tensile method is demonstrated on a variety of standard and high-performance coatings, and it is shown that the method detects differentiation between commercial foul release coatings that could not be resolved using other methods.

42 ENGINEERING↗

On the determination of the electromagnetic field upon scattering by a small inhomogeneous spherical object

An efficient and fairly simple method of solving the problem of the incidence of a plane electromagnetic wave on an inhomogeneous object with specified spherically symmetric distributions of its electric permittivity and magnetic permeability is presented. The fields inside the object and the integrated scattering and absorption cross sections are found by assuming the object to be small compared to the vacuum wavelength. Since no constraints are imposed on the scales of the fields inside the object, the method is suitable for investigating complex cases, including those associated with the local amplification and absorption of the electromagnetic field in inhomogeneous resonant media.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method for registration of solar cosmic rays by detecting neutrons

We consider a method of detecting the ionizing component of solar cosmic rays (SCRs) with energy from tens of MeV to tens of GeV by measuring the energy loss of SCR protons and light nuclei in scintillators and the multiplicity of the local neutron generation in a converter. Scintillation detectors based on stilbene, lithium glass, and solid-state photomultiplier tubes are capable of detecting fast neutrons with a temporal resolution of 10 ns and rejecting the gamma-ray background in the measuring system. The method will allow investigating the nucleon components of primary SCRs in circumterrestrial space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Latest results from Double Chooz

Double Chooz is a short-baseline neutrino disappearance experiment. It detects ν̄{sub e }produced in the power plant of Chooz, France, where is located. The main goal of the experiment is the measurement of θ{sub 13} mixing angle and in 2011 for the first time the experiment observed an indication for a non zero value of such an oscillation parameter. The mixing angle was successively measured using only the far detector finding the best fit value of sin{sup 2}(2θ{sub 13}) = 0.090{sup +0.032}{sub −0.029} . The near detector is under construction and will start data taking by the middle of 2014 allowing the reduction of the systematic errors. In this paper I make a review of the Double Chooz experiment, focusing in particular on the latest results of the measurement of the mixing angle θ{sub 13} relying on the neutron absorption on Gadolinium. I also present results proving the capability of Double Chooz to identify the ortho-positronium. This has been done in an event-by-event basis for the first time in a large liquid scintillator experiments, and can be an additional handle for the electron/positron discrimination in future detectors based on such technology.

42 ENGINEERING↗

Spin Injection and Accumulation in the Planar NiFe–InSb–NiFe and NiFe–Cu–NiFe Spin Valves

Spin injection and accumulation have been studied for NiFe–InSb–NiFe and NiFe–Cu–NiFe planar spin valves with direct injection current I in nonlocal (NLSV) and local (LSV) measurement configurations at temperature 8–300 K. The value of the generated voltage U and the character of the dependence U(I) drastically changed for currents I greater some critical value I{sub c} due to thermoelectric effects. For NLSV configuration and currents I<I{sub c} the value of U is of 2–3 order of magnitude higher for NiFe–InSb–NiFe (U ≈ 1–3 mV at 300 K) structures in comparison with NiFe–Cu–NiFe (U ≈ 4–20 µV at 8 K). For LSV geometry electrical detection of spin current was observed only for NiFe–Cu–NiFe structure, where for I<I{sub c} the magnetoresistance (MR) effect of the order 0.5% was detected. For currents I of 1.5–2% higher than I{sub c} the MR of the order of 10–30% was observed for both NLSV and LSV configurations for studied structures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental Setup for Neutron Lifetime Measurements with a Large Gravitational Trap at Low Temperatures

Currently the most accurate measurements of neutron lifetime are being performed at the Petersburg Nuclear Physics Institute with ultracold neutrons (UCNs) stored in a gravitational trap. A modified setup with a large gravitational trap and cooling to 10–15 K is presented. The results of measurements of temperature dependence of UCN losses in collisions with walls, which were coated with a perfluorinated grease (Fomblin UT 18), at 300–77 K, are detailed. The probable heat inflow to the trap is estimated, and the feasibility of cooling to indicated temperatures in experiments with the modified setup is demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of Direct Optical Heterodyning for Measuring Hardness by the Leeb Method

In this paper, we describe a portable system for measuring the indenter velocity in hardness meters implemented according to the Leeb method. The developed system is a fiber interferometer, in which a radiation source is a semiconductor laser with a wavelength of 1550 nm. The presented experimental results confirm the ability of the system to measure indenter velocities with an uncertainty of 0.001 m/s, which satisfies the requirements of the standards for this method of measuring hardness.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ESS-DIVE Reporting Format for Location Metadata

The ESS-DIVE location metadata reporting format provides instructions and templates for reporting a minimum set of metadata for discrete point locations in geographic space represented by x, y, and z coordinates. This format was created based on a need for earth and environmental science researchers to more consistently provide metadata about locations where they conduct studies. To create the format, we incorporated elements from ESS-DIVE’s community reporting formats as well as 12 additional data standards or other data resources (e.g., databases, data systems, or repositories). In the template, we ask researchers to indicate unique locations using Location IDs and indicate hierarchies of locations through parent location IDs. We also provide additional optional fields for researchers to indicate how they measured the point location and the date and time that the location was first used as a research siteThis dataset contains support documentation for the reporting format (README.md and instructions.md), a terminology guide (guide.md), a crosswalk indicating how this reporting format relates to existing standards and data resources (Location_metadata_crosswalk.csv), a data dictionary (dd.csv), file-level metadata (flmd.csv), and the location metadata templates in both CSV (Location_metadata_template.csv) and Excel formats (Location_metadata_template.xlsx).

54 ENVIRONMENTAL SCIENCES↗

Capturing the Future: Direct and Indirect Probes of Neutron Capture

This report documents aspects of direct and indirect neutron capture. The importance of neutron capture rates and methods to determine them are presented. The following conclusions are drawn: direct neutron capture measurements remain a backbone of experimental study; work is being done to take increased advantage of indirect methods for neutron capture; both instrumentation and facilities are making new measurements possible; more work is needed on the nuclear theory side to understand what is needed furthest from stability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

AGS vertical beta function measurements for Run 15

One key parameter for running the AGS efficiently is by maintaining a low emittance. To measure emittance, one needs to measure the beta function throughout the cycle. This can be done by measuring the beta function at the ionization profile monitors (IPM) in the AGS. This tech note delves into the motivation, the measurement, and some strides that were made throughout Run15.

43 PARTICLE ACCELERATORS↗

Surrogate Measurements of Actinide (n,2n) Cross Sections with NeutronSTARS

Directly measuring (n,2n) cross sections on short-lived actinides presents a number of experimental challenges. The surrogate reaction technique is an experimental method for measuring cross sections on short-­lived isotopes, and it provides a unique solution for measuring (n,2n) cross sections. This technique involves measuring a charged-­particle reaction cross section, where the reaction populates the same compound nucleus as the reaction of interest. To perform these surrogate (n,2n) cross section measurements, a silicon telescope array has been placed along a beam line at the Texas A&M University Cyclotron Institute, which is surrounded by a large tank of gadolinium-doped liquid scintillator, which acts as a neutron detector. The combination of the charge-particle and neutron-detector arrays is referred to as NeutronSTARS. In the analysis procedure for calculating the (n,2n) cross section, the neutron detection efficiency and time structure plays an important role. Due to the lack of availability of isotropic, mono-energetic neutron sources, modeling is an important component in establishing this efficiency and time structure. This report describes the NeutronSTARS array, which was designed and commissioned during this project. It also describes the surrogate reaction technique, specifically referencing a 235 U(n,2n) commissioning measurement that was fielded during the past year. Advanced multiplicity analysis techniques have been developed for this work, which should allow for efficient analysis of 241 Pu(n,2n) and 239 Pu(n,2n) cross section measurements

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗