Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement uncertainty”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Determination of jet calibration and energy resolution in proton–proton collisions at $\sqrt{s} = 8~\hbox {TeV}$ using the ATLAS detector

The jet energy scale, jet energy resolution, and their systematic uncertainties are measured for jets reconstructed with the ATLAS detector in 2012 using proton–proton data produced at a centre-of-mass energy of 8 TeV with an integrated luminosity of 20fb -1 . Jets are reconstructed from clusters of energy depositions in the ATLAS calorimeters using the anti-k t algorithm. A jet calibration scheme is applied in multiple steps, each addressing specific effects including mitigation of contributions from additional proton–proton collisions, loss of energy in dead material, calorimeter non-compensation, angular biases and other global jet effects. The final calibration step uses several in situ techniques and corrects for residual effects not captured by the initial calibration. Furthermore, these analyses measure both the jet energy scale and resolution by exploiting the transverse momentum balance in γ + jet, Z + jet, dijet, and multijet events. A statistical combination of these measurements is performed. In the central detector region, the derived calibration has a precision better than 1% for jets with transverse momentum 150 GeV < p T < 1500 GeV, and the relative energy resolution is (8.4 ± 0.6)% for p T =100 GeV and (23 ± 2)% for p T =20 GeV. The calibration scheme for jets with radius parameter R = 1.0, for which jets receive a dedicated calibration of the jet mass, is also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of non-prompt ${{\textrm{D}}^{0}}$-meson elliptic flow in Pb–Pb collisions at $\sqrt{s_{\textrm{NN}}} = 5.02$ TeV

The elliptic flow (v 2 ) of D 0 mesons from beauty-hadron decays (non-prompt D 0 was measured in midcentral (30–50%) Pb–Pb collisions at a centre-of-mass energy per nucleon pair $\sqrt{s_{\textrm{NN}}} = 5.02$ TeV with the ALICE detector at the LHC. The D 0 mesons were reconstructed at midrapidity $(|y|<0.8)$ from their hadronic decay D 0 →$K^-\pi^+$, in the transverse momentum interval $2< p_{\textrm{T}} < 12$ GeV/c. The result indicates a positive v 2 for non-prompt D 0 mesons with a significance of 2.7σ. The non-prompt D 0 -meson v 2 is lower than that of prompt non-strange D mesons with 3.2σ significance in $2< p_\textrm{T} < 8~\textrm{GeV}/c$, and compatible with the v 2 of beauty-decay electrons. Theoretical calculations of beauty-quark transport in a hydrodynamically expanding medium describe the measurement within uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Manufacturability-based optical design optimization for advanced Kirkpatrick–Baez X-ray focusing mirrors

The advanced Kirkpatrick–Baez (AKB) mirror setup is an effective and compelling solution to provide stable X-ray nano-focusing for synchrotron radiation or free-electron laser beamlines. We propose an AKB mirror design optimization approach to mitigate the difficulties associated with mirror fabrication by minimizing the total slope ranges of the four curved mirrors while achieving the expected focusing performance. In the optimization, we have considered geometry constraints to ensure the beam acceptance with the required clear aperture, the diffraction-limited focal size with the adequate numerical aperture, and the desired mirror gaps for adjustment and the necessary working distance for the sample stage. Additionally, practical constraints linked to mirror metrology and fabrication, such as mirror length limits and curvature uncertainty in measurement, are taken into account. Furthermore, progressive objective optimization eliminates the need for any initial guess, fully automating the AKB optimization process. This approach facilitates the development of an elegant Wolter-I or Wolter-III type AKB design solution that satisfies these multiple constraints. In cases where constraints cannot be simultaneously satisfied, the optimization results provide valuable insights into areas where trade-offs need to be considered. Simulations with ray tracing and wavefront propagation validate the optimized AKB design showing high tolerance to the beam incident angle.

36 MATERIALS SCIENCE↗

Stability and Convergence of Solutions to Stochastic Inverse Problems Using Approximate Probability Densities

Data-consistent inversion is designed to solve a class of stochastic inverse problems where the solution is a pullback of a probability measure specified on the outputs of a quantities of interest (QoI) map. Here, this work presents stability and convergence results for the case where finite QoI data result in an approximation of the solution as a density. Given their popularity in the literature, separate results are proven for three different approaches to measuring discrepancies between probability measures: f-divergences, integral probability metrics, and L p metrics. In the context of integral probability metrics, we also introduce a pullback probability metric that is well-suited for data-consistent inversion. This fills a theoretical gap in the convergence and stability results for data-consistent inversion that have mostly focused on convergence of solutions associated with approximate maps. Numerical results are included to illustrate key theoretical results with intuitive and reproducible test problems that include a demonstration of convergence in the measure-theoretic "almost" sense.

97 MATHEMATICS AND COMPUTING↗

Geometric Scale-up Experiments on Fluidization of Geldart B Glass Beads

The objective of this work is to provide a valuable database from controlled experiments for validating computational models. Recently, coarse-grained techniques such as particle-in-cell (PIC) or coarse-grained discrete element modeling (DEM) have gained popularity due to their computational efficiency while modeling large-scale systems; however, the influence of model parameters and their sensitivities at different geometric scales and flow conditions remain to be analyzed. These datasets are critical for the multiphase flow research community to assess predictive capability of modeling techniques as well as elucidate the hydrodynamic behavior in these systems. This study performed fluidization experiments using three different test sections with internal diameters of 2.5, 4, and 6 in. The operating conditions, bed material, and range of flow velocities at the inlet were constant in all the units, which were not hydrodynamically scaled. Glass beads having a Sauter Mean Diameter of 332 μm were used. Superficial velocity was varied from 2.97 to 5.35 times the minimum fluidization velocity and the initial static bed height was 0.1524 m. The order in which the experiments were performed was randomized and replicates were included to provide uncertainty in measurements. Statistics of differential pressure and bed height from these tests were reported. Future plans include validating PIC methodology in the open-source software, MFiX (Multiphase Flow with Interphase Exchanges) using results from this study. This could further be extended to determine optimal model parameters using inverse techniques such as deterministic calibration or Bayesian inference.

20 FOSSIL-FUELED POWER PLANTS↗

Geometric Scale-up Experiments on Fluidization of Geldart B Glass Beads

The objective of this work is to provide a valuable database from controlled experiments for validating computational models. Recently, coarse-grained techniques such as particle-in-cell (PIC) or coarse-grained discrete element modeling (DEM) have gained popularity due to their computational efficiency while modeling large-scale systems; however, the influence of model parameters and their sensitivities at different geometric scales and flow conditions remain to be analyzed. These datasets are critical for the multiphase flow research community to assess predictive capability of modeling techniques as well as elucidate the hydrodynamic behavior in these systems. This study performed fluidization experiments using three different test sections with internal diameters of 2.5, 4, and 6 in. The operating conditions, bed material, and range of flow velocities at the inlet were constant in all the units, which were not hydrodynamically scaled. Glass beads having a Sauter Mean Diameter of 332 μm were used. Superficial velocity was varied from 2.97 to 5.35 times the minimum fluidization velocity and the initial static bed height was 0.1524 m. The order in which the experiments were performed was randomized and replicates were included to provide uncertainty in measurements. Statistics of differential pressure and bed height from these tests were reported. Future plans include validating PIC methodology in the open-source software, MFiX (Multiphase Flow with Interphase Exchanges) using results from this study. This could further be extended to determine optimal model parameters using inverse techniques such as deterministic calibration or Bayesian inference.

42 ENGINEERING↗

Three Delayed Critical 15-Inch-Diameter Interacting Enriched (93.14) Uranium Metal Cylinders Without Moderator and Reflector

This report documents very accurately the configuration and the materials for experiments with three unmoderated, unreflected, interacting, coaxial, highly enriched, 15-in.-diameter, uranium metal cylinders performed at the Oak Ridge Critical Experiments Facility (ORCEF) in August and September 1963 and described in logbook E 20 associated with experiments in the East cell of ORCEF. The information is sufficiently accurate that it can be used as the basis for preparation of benchmarks for International Criticality Safety Benchmark Program (ICSBEP) at Idaho National laboratory. The thickness of the cylinders was varied and the spacing between them was adjusted to achieve a delayed critical configuration. The average enrichment of the uranium metal was 94.14 wt. % 235U. The heights of the 15-in.-diameter, equal-height cylinders varied from 1-1/8to 2.00 inches. All interacting cylinders were assembled coaxially with their flat faces parallel and their combined masses varied between 182 and 325 kilograms of HEU metal. The data from these six experiments described are judged to be acceptable for use as criticality safety benchmark experiments for the ICSBEP and EURATOM’s Nuclear Energy Agency nuclear criticality safety benchmark program, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, it is expected that the uncertainties in measured keff could be as low as ± 0.0002.

36 MATERIALS SCIENCE↗

Time-of-Flight Estimation for Nondestructive Evaluation

Ultrasonic testing (UT) for nondestructive evaluation (NDE) is a critical entity necessary to resolve both the quality and precision questions of complex parts evolving from the classical approaches to the innovative additive manufacturing (AM) process. This modality provides the essential quantitative information for acceptance and potential flaw detectionof apart under investigation. A primary ingredient in UT besides the required precision robotic hardware for theacquisition of high-qualitymeasurement data is the underlying signal processing. It is here that much of the system performance capability resides. In this report,we discuss the basic steps in UT signal processing along with current capabilities that must be achieved in order to satisfy the criticaldemands of the various LLNL programs.In itsbasic foundations, signal processing is essentially the “extraction of critical information (signals) from noisy, uncertain data.” Clearly, in a perfect world the best signal processing is none---just make a reliable, noise-free, uncertainty-free, measurement. Unfortunately, even the best of systems is still straddled within the confines and limitations of physical instrumentation. With this in mind, we discuss the development of signal processing techniques toextract the desired UT information from noisy measurement data. We start with a discussion of a simple homogeneous representation of a “part” under investigation and its insonification by an ultrasonicexcitation from a physics-based perspective. Once developed, we briefly discussthe various choices of excitation signals and their tradeoffs.Next,we discuss a simulation approach employing simple models from the signal processing perspective and then move on to the development of the basic signal processing approach to ultrasonic signal processing all based on estimating the pulse arrival estimation. Starting with simple peak detection techniques, progressing to the processing workhorse so-called “matched-filter” and finally to the more sophisticated “model-based matched filter.”The underlying pre-and post-processing of noisy measurement data along with the application of these techniques are subsequently demonstrated on experimental ultrasonic data.Finally, we present some results for processing “weld” data when the ultrasonic excitation signal is not directly available.

42 ENGINEERING↗

Validation of the EDGES Low-band Antenna Beam Model

The response of the antenna is a source of uncertainty in measurements with the Experiment to Detect the Global Epoch of Reionization Signature (EDGES). We aim to validate the electromagnetic beam model of the low-band (50–100 MHz) dipole antenna with comparisons between models and against data. We find that simulations of a simplified model of the antenna over an infinite perfectly conducting ground plane are, with one exception, robust to changes in the numerical electromagnetic solver code or algorithm. For simulations of the antenna with the actual finite ground plane and realistic soil properties, we find that two out of three numerical solvers agree well. Applying our analysis pipeline to a simulated drift-scan observation from an early EDGES low-band instrument that had a 10 m × 10 m ground plane, we find residual levels after fitting and removing a five-term foreground model from the simulated data binned in local sidereal time (LST) average about 250 mK with ±40 mK variation between numerical solvers. A similar analysis of the primary 30 m × 30 m sawtooth ground plane reduced the LST-averaged residuals to about 90 mK with ±10 mK between the two viable solvers. More broadly we show that larger ground planes generally perform better than smaller ground planes. Simulated data have a power that is within 4% of real observations, a limitation of net accuracy of the sky and beam models. We observe that residual spectral structures after foreground model fits match qualitatively between simulated data and observations, suggesting that the frequency dependence of the beam is reasonably represented by the models. We find that a soil conductivity of 0.02 S m{sup -1} and relative permittivity of 3.5 yield good agreement between simulated spectra and observations. This is consistent with the soil properties reported by Sutinjo et al. for the Murchison Radio-astronomy Observatory, where EDGES is located.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Orbital-Radar v1.0.0: a tool to transform suborbital radar observations to synthetic EarthCARE cloud radar data

The Earth Cloud, Aerosol and Radiation Explorer (EarthCARE) satellite developed by the European Space Agency (ESA) and the Japan Aerospace Exploration Agency (JAXA) launched in May 2024 carries a novel 94 GHz cloud profiling radar (CPR) with Doppler capability. This work describes the open-source instrument simulator Orbital-Radar, which transforms high-resolution radar data from field observations or forward simulations of numerical models to CPR primary measurements and uncertainties. The transformation accounts for sampling geometry and surface effects. We demonstrate Orbital-Radar's ability to provide realistic CPR views of typical cloud and precipitation scenes. The presented case studies show small-scale convection, marine stratus clouds, and Arctic mixed-phase cloud cases. These results provide valuable insights into the capabilities and challenges of the EarthCARE CPR mission and its advantages over the CloudSat CPR. Finally, Orbital-Radar allows for evaluating kilometre-scale numerical weather prediction models with EarthCARE CPR observations. So, Orbital-Radar can generate calibration and validation (Cal/Val) data sets already pre-launch. Nevertheless, an evaluation of synthetic CPR output data to accurate EarthCARE CPR data is missing.

54 ENVIRONMENTAL SCIENCES↗

Quantifying replication through repeated analysis of UVM-A, a liquid reference material for cosmogenic 10 Be and 26 Al studies

In this study, in-situ produced cosmogenic nuclide sample preparation and analysis is a complicated, multi-step process with numerous possible sources of error, many of which have not been robustly quantified. Here, we use a liquid reference material (UVM-A) to test whether the analytic precision associated with individual isotopic ratios (n = 96) measured at two Accelerator Mass Spectrometry facilities (Lawrence Livermore National Laboratory and Purdue Rare Isotope Measurement Laboratory) accurately represents the range of values determined for aliquots prepared in a single laboratory over a period of five years. We find that 10 Be/ 9 Be ratios measured at the different accelerator facilities (n = 26 and n = 70) have statistically indistinguishable central tendencies, matching to within 0.1 %. Based on this large dataset, we suggest preliminary consensus values for UVM-A of 1.45 ± 0.06 x 10 -13 for 10 Be/ 9 Be (mean, one standard deviation, n = 96) and 4.47 ± 0.22 x 10 -13 for 26 Al/ 27 Al (mean, one standard deviation, n = 27). For both 10 Be/ 9 Be and 26 Al/ 27 Al, the relative standard deviations of the measured ratios are similar to the reported analytic uncertainties of sample measurement, suggesting that sample preparation introduced little if any additional scatter beyond the uncertainty of isotopic analysis. This dataset demonstrates that robust sample preparation and measurement can generate isotope ratio data reproducible at the level of counting statistics.

58 GEOSCIENCES↗

A non-intrusive optical (NIO) approach to characterize heliostats in utility-scale power tower plants: Sensitivity study

Power towers, a type of concentrating power tower technology, use a large number of heliostats to concentrate sunlight and produce renewable energy. Optical errors of heliostats can cause drastic losses in the efficiency of power-tower plants. Accurately measuring optical errors is crucial to assessing and improving plant performance. This analysis discusses an innovate non-intrusive optical (NIO) approach to measure slope, canting, and tracking errors by detecting distortions in the reflected tower structure in heliostat images. Further in this work a sensitivity study is carefully conducted to determine the uncertainty requirements to allow the method to calculate slope errors with an accuracy of 0.25 mrad. Measurement uncertainty sources include camera resolution and position uncertainty, tower position uncertainty, and number of collected images. Each uncertainty source is investigated to determine its impact on the accuracy of the slope-error calculation. A combination of theoretical results and experimental results obtained from data collected on a heliostat at Sandia National Laboratories is used to determine and validate uncertainty requirements. The analysis shows that a measurement uncertainty of 0.25 mrad can be realized by realistically controlling uncertainty sources when implementing the NIO method. It demonstrates the superior performance of NIO in performing in-situ optical characterization.

14 SOLAR ENERGY↗

Pressure-Driven Fiber-Optic Sensor for Online Corrosion Monitoring

For many industrial applications, corrosion is a life-limiting phenomenon and therefore requires careful consideration and rigorous experimental testing before structural materials can be reliably deployed, particularly in harsh chemical environments. The traditional approach to measuring corrosion requires exposing many samples to the intended environment and then extracting them individually at discrete intervals for postexposure characterization. This approach does not provide a high degree of temporal resolution, nor does it provide any real-time information regarding dynamic changes in corrosion rates. Additionally, developing an online corrosion monitor capable of surviving harsh chemical environments could provide valuable information regarding the structural health of components and changing process conditions that could accelerate corrosion. To this end, a corrosion sensor was developed based on a pressure-driven Fabry-Pérot cavity (FPC). This sensor uses a pressure control system to internally pressurize the FPC formed between the sensor’s housing and a metal-embedded singlemode optical fiber. Simultaneous measurement of the change in FPC length using low-coherence interferometry and the applied pressure enables the calculation of the relative changes in the sensor’s diaphragm thickness due to corrosion on its outer surface. Measurements were made in situ while actively corroding the sensor and were validated against surveillance specimens that were corroded simultaneously. The uncertainties in the measured corrosion were analyzed using error propagation of the uncertainties in the measured pressures and displacements and were found to be <1% of the initial diaphragm thickness.

42 ENGINEERING↗

Heat capacity of microgram oxide samples by fast scanning calorimetry

Quantitative scanning calorimetry on microgram-sized samples opens a broad, new range of opportunities for studying the thermodynamic properties of quantity-limited materials, including those produced under extreme conditions or found as rare accessory minerals in nature. We calibrated the Mettler Toledo Flash DSC 2+ calorimeter to obtain quantitative heat capacities in the range 200–350 °C, using samples weighing between 2 and 11.5 μg. Our technique is applied to a new set of oxide materials to which it has never been used before, without the need for melting, glass transitions, or phase transformations. Heat capacity data were obtained for silica in the high pressure stishovite (rutile) structure, dense post-stishovite glass, standard fused quartz, and for TiO2 rutile. These heat capacities agree within 5%–15% with the literature values reported for rutile, stishovite, and fused SiO2 glass. The heat capacity of post-stishovite glass, made by heating stishovite to 1000 °C, is a newly reported value. After accurate calibrations, measured heat capacities were then used to calculate masses for samples in the microgram range, a substantial improvement over measurement in conventional microbalances, which have uncertainties approaching 50%–100% for such small samples. Since the typical uncertainty of heat capacities measured on 10–100 mg samples in conventional differential scanning calorimetry is typically 7% (1%–5% with careful work), flash differential scanning calorimetry, using samples a factor of 1000 smaller, increases the uncertainty of heat capacity measurements by a factor of <3, opening the door for meaningful measurements on ultra-small, high-pressure samples and other quantity-limited materials.

Instruments & Instrumentation↗

Stastically determined experimental uncertainties in photon Doppler velocimetry (PDV) measurements

Shock-ramp experiments place high demands on the precision, accuracy, and temporal resolution of transformed velocimetry signals. To minimize uncertainty after total propagation of a shockramp experiment, ideally multiple PDV traces are used. However, each trace has some uncertainty that is a function of the PDV system and analysis of the velocimetry data. In order to determine a reasonable experimental estimate of minimum uncertainty, we calculate observed uncertainties in as-fielded PDV systems using multiple channels to sample the velocity on each shot. We also calculate the uncertainty’s sensitivity to choice of analysis methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of Interaction Uncertainties on Neutrino-Nucleus Cross Section Measurements

Accelerator-based neutrino facilities represent forefront scientific endeavors, employing state-of-the-art techniques to investigate the properties of neutrinos and unveil signals of physics beyond the standard model. Neutrino-nucleus interactions constitute one of the biggest systematics in these experiments. As neutrino-nucleus cross section measurement statistics have started to surge in recent years, it's becoming vital to control systematics in these measurements. This presentation explores the pivotal role of neutrino interaction uncertainties, including nuclear effects and modeling approximations, in achieving precise neutrino cross-section measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High precision 5 MeV Mott polarimeter

We report on the design and performance of a Mott polarimeter optimized for a nominal 5-MeV electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF) injector. The rf time structure of this beam allows the use of time of flight in the scattered electron detection, making it possible to cleanly isolate those detected electrons that originate from the scattering foil, and resulting in measured scattering asymmetries which are exceptionally stable over a broad range of beam conditions, beam currents, and foil thicknesses. In two separate series of measurements from two different photocathode electron sources, we have measured the Mott scattering asymmetries produced by an approximately 86% transversely polarized electron beam incident on ten gold foils with nominal thicknesses between 50 and 1000 nm. The statistical uncertainty of the measured asymmetry from each foil is below 0.25%. Within this statistical precision, the measured asymmetry was unaffected by ±1-mm shifts in the beam position on the target foil, and by beam current changes and dead-time effects over a wide range of beam currents. The overall uncertainty of our beam polarization measurement, arising from the uncertainty in the value of the scattering asymmetry at zero foil thickness as determined from our fits to the measured asymmetries versus scattering foil thicknesses, the estimated systematic effects, and the (dominant) uncertainty from the calculation of the theoretical Sherman function, is 0.61%. A simulation of the polarimeter using geant4 has confirmed that double scattering in the target foil is the sole source of the dependence of the measured asymmetry on foil thickness, and gives a result for the asymmetry versus foil thickness in good agreement with both our measurements and a simple calculation. Future measurements at different beam energies and with target foils of different atomic numbers will seek to bound uncertainties from small effects such as radiative corrections to the calculation of the polarimeter analyzing power. A simultaneous high-precision measurement of the beam polarization with a different polarimeter, AESOP (Accurate Electron Spin Optical Polarimeter), under development at the University of Nebraska, clearly possible at the CEBAF accelerator, will allow a high-precision comparison of our measured asymmetries with theoretical calculations of the Mott analyzing power. Finally, the improved precision of the current Mott polarimeter along with similar improvements to other Jefferson Lab polarimeters warrants another precision comparison of all of these polarimeters when measuring a beam of the same polarization.

Grames, J. M. (ORCID:0000000193908752)↗