Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MULTIPLEXER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Dependence of the bit error rate on the signal power and length of a single-channel coherent single-span communication line (100 Gbit s{sup -1}) with polarisation division multiplexing

We have studied experimentally and using numerical simulations and a phenomenological analytical model the dependences of the bit error rate (BER) on the signal power and length of a coherent single-span communication line with transponders employing polarisation division multiplexing and four-level phase modulation (100 Gbit s{sup -1} DP-QPSK format). In comparing the data of the experiment, numerical simulations and theoretical analysis, we have found two optimal powers: the power at which the BER is minimal and the power at which the fade margin in the line is maximal. We have derived and analysed the dependences of the BER on the optical signal power at the fibre line input and the dependence of the admissible input signal power range for implementation of the communication lines with a length from 30 – 50 km up to a maximum length of 250 km. (optical transmission of information)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Projection multiplex recording of computer-synthesised one-dimensional Fourier holograms for holographic memory systems: mathematical and experimental modelling

A multiplex method of recording computer-synthesised one-dimensional Fourier holograms intended for holographic memory devices is proposed. The method potentially allows increasing the recording density in the previously proposed holographic memory system based on the computer synthesis and projection recording of data page holograms. (holographic memory)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Compensation for nonlinear effects in an optical orthogonal frequency-division multiplexed signal using adaptive modulation

We study the influence of nonlinear effects on symbol error statistics when a 16-QAM orthogonal frequency-division multiplexed signal is transmitted in a 1000 km length of fibre. A technique of adaptive modulation is proposed for generating signals that are resistant to nonlinear distortions. A considerable improvement of the transmission quality is shown to take effect in using an adaptive modulation scheme. (paper)

42 ENGINEERING↗

Coherent elastographic tomography via speckle time multiplexing

A method is suggested for separating photons coming from different depths of tissue while externally stimulating tissue via infra-sonic vibration. The process of tomographic information extraction using the speckle time multiplexing approach is presented. Use is also made of a modulated laser combining a speckle-pattern tracking method for sensing surface tilting changes with an interferometer for sensing surface z-axis changes at the same scan time. (paper)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advancing the High Throughput Identification of Liver Fibrosis Protein Signatures Using Multiplexed Ion Mobility Spectrometry

Rapid diagnosis of disease states using less invasive, safer, and more clinically acceptable approaches than presently employed is an imperative goal for the field of medicine. While mass spectrometry (MS)-based proteomics approaches have attempted to meet these objectives, challenges such as the enormous dynamic range of protein concentrations in clinically relevant biofluid samples coupled with the need to address human biodiversity have slowed their employment. Herein, we report on the use of a new platform that addresses these challenges by coupling technical advances in rapid gas phase multiplexed ion mobility spectrometry (IMS) separations [1, 2] with liquid chromatography (LC) and MS to dramatically increase measurement sensitivity and throughput, further enabling future MS-based clinical applications. An initial application of the LC-IMS-MS platform for the analysis of blood serum samples from stratified post-liver transplant patients with recurrent fibrosis progression illustrates its potential utility for disease characterization and use in personalized medicine [3, 4].

Environmental Molecular Sciences Laboratory↗

First results from a multiplexed and massive instrument with sub-electron noise Skipper-CCDs

Here, we present a new instrument composed of a large number of sub-electron noise Skipper-CCDs operated with a two stage analog multiplexed readout scheme suitable for scaling to thousands of channels. New, thick, 1.35 Mpix sensors, from a new foundry, are glued into a Multi-Chip Module (MCM) printed circuit board on a ceramic substrate which has 16 sensors each. The instrument, that can hold up-to 16 MCMs, a total of 256 Skipper-CCD sensors (called a Super-Module with ≈ 130 grams of active mass and 346 Mpix), is part of the R&D effort of the OSCURA experiment which will have ≈ 94 super-modules. Experimental results with 10 MCMs and 160 Skipper-CCDs sensors are presented in this paper. This is already the largest ever built instrument with single electron sensitivity CCDs using nondestructive readout, both, in terms of active mass and number of channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RWRtoolkit: multi-omic network analysis using random walks on multiplex networks in any species

Abstract We introduce RWRtoolkit, a multiplex generation, exploration, and statistical package built for R and command-line users. RWRtoolkit enables the efficient exploration of large and highly complex biological networks generated from custom experimental data and/or from publicly available datasets, and is species agnostic. A range of functions can be used to find topological distances between biological entities, determine relationships within sets of interest, search for topological context around sets of interest, and statistically evaluate the strength of relationships within and between sets. The command-line interface is designed for parallelization on high-performance cluster systems, which enables high-throughput analysis such as permutation testing. Several tools in the package have also been made available for use in reproducible workflows via the KBase web application.

Kainer, David (ORCID:0000000172714676)↗

Molecular underpinnings of ssDNA specificity by Rep HUH-endonucleases and implications for HUH-tag multiplexing and engineering

Abstract Replication initiator proteins (Reps) from the HUH-endonuclease superfamily process specific single-stranded DNA (ssDNA) sequences to initiate rolling circle/hairpin replication in viruses, such as crop ravaging geminiviruses and human disease causing parvoviruses. In biotechnology contexts, Reps are the basis for HUH-tag bioconjugation and a critical adeno-associated virus genome integration tool. We solved the first co-crystal structures of Reps complexed to ssDNA, revealing a key motif for conferring sequence specificity and for anchoring a bent DNA architecture. In combination, we developed a deep sequencing cleavage assay, termed HUH-seq, to interrogate subtleties in Rep specificity and demonstrate how differences can be exploited for multiplexed HUH-tagging. Together, our insights allowed engineering of only four amino acids in a Rep chimera to predictably alter sequence specificity. These results have important implications for modulating viral infections, developing Rep-based genomic integration tools, and enabling massively parallel HUH-tag barcoding and bioconjugation applications.

59 BASIC BIOLOGICAL SCIENCES↗

Mode Multiplexing for Scalable Cavity-Enhanced Operations in Neutral-Atom Arrays

Neutral-atom arrays provide a versatile platform for quantum information processing. However, in large-scale arrays, efficient photon collection remains a bottleneck for key tasks such as fast, nondestructive qubit readout and remote entanglement distribution. We propose a cavity-based approach that enables fast, parallel operations over many atoms using multiple modes of a single optical cavity. By selectively shifting the relevant atomic transitions, each atom can be coupled to a distinct cavity mode, allowing independent simultaneous processing. We present practical system designs that support cavity-mode multiplexing with up to 50 modes, enabling rapid mid-circuit syndrome extraction and significantly enhancing entanglement distribution rates between remote atom arrays. This approach offers a scalable solution to core challenges in neutral-atom arrays, advancing the development of practical quantum technologies.

Aqua, Ziv [Massachusetts Institute of Technology (↗

Diamond channel-cut crystals for high-heat-load beam-multiplexing narrow-band X-ray monochromators

Next-generation high-brilliance X-ray photon sources call for new X-ray optics. Here we demonstrate the possibility of using monolithic diamond channel-cut crystals as high-heat-load beam-multiplexing narrow-band mechanically stable X-ray monochromators with high-power X-ray beams at cutting-edge high-repetition-rate X-ray free-electron laser (XFEL) facilities. The diamond channel-cut crystals fabricated and characterized in these studies are designed as two-bounce Bragg reflection monochromators directing 14.4 or 12.4 keV X-rays within a 15 meV bandwidth to 57 Fe or 45 Sc nuclear resonant scattering experiments, respectively. The crystal design allows out-of-band X-rays transmitted with minimal losses to alternative simultaneous experiments. Only ≲2% of the incident ∼100 W X-ray beam is absorbed in the 50 µm-thick first diamond crystal reflector, ensuring that the monochromator crystal is highly stable. Other X-ray optics applications of diamond channel-cut crystals are anticipated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization and optimization of an eight-channel time-multiplexed pulse-shaping system

High-performance optical pulse shaping is paramount to photonics and lasers applications for which high-resolution optical waveforms must be generated. We investigate the design and performance of a time-multiplexed pulse shaping (TMPS) system in which optical waveforms from a single pulse-shaping unit are demultiplexed and retimed before being sent to different optical systems. This architecture has the advantages of low cost and low relative jitter between optical waveforms because a single pulse-shaping system, e.g., a high-performance arbitrary waveform generator driving a Mach-Zehnder modulator, generates all the waveforms. We demonstrate an eight-channel TMPS system based on a 1 × 8 LiNbO 3 demultiplexer composed of four stages of 1 × 2 Δβ phase-reversal switches that allow for demultiplexing and extinction enhancement via application of a control voltage modifying the propagation constant difference between adjacent waveguides. It is shown that optimal demultiplexing, i.e. low insertion loss and high extinction ratio between channels, requires optimization in dynamic operation because of the slow component of the switches’ response. Lastly, we demonstrate losses lower than 5 dB, extinction ratios of the order of 70 dB for a four-channel system and 50 dB for an eight-channel system, and jitter added by the demultiplexer smaller than 0.1 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Safety Design for Smart Electric Vehicle Charging with Current and Multiplexing Control

As Electric Vehicles (EVs) increase, charging infrastructure becomes more important. When during the day there is a power shortage, the charging infrastructure should have the options to either shut off the power to the charging stations or to lower the power to the EVs in order to satisfy the needs of the grid. This paper proposes a design for a smart charging infrastructure capable of providing power to several EVs from one circuit by multiplexing power and providing charge control and safety systems to prevent electric shock. The safety design is implemented in different levels that include both the server and the smart charging stations. With this smart charging infrastructure, the shortage of energy in a local grid could be solved by our EV charging management system.

Chung, Ching-Yen↗

Target allocation yields for massively multiplexed spectroscopic surveys with fibers

We present Simulated Annealing fiber-to-target allocation simulations for the proposed DESI and 4MOST massively multiplexed spectroscopic surveys, and for both Poisson and realistically clustered mock target samples. We simulate both Echidna and theta-phi actuator designs, including the restrictions caused by the physical actuator characteristics during repositioning. For DESI, with theta-phi actuators, used in 5 passes over the sky for a mock ELG/LRG/QSO sample, with matched fiber and target densities, a total target allocation yield of 89.3% was achieved, but only 83.7% for the high-priority Ly-alpha QSOs. If Echidna actuators are used with the same pitch and number of passes, the yield increases by 5.7% and 16% respectively. Echidna also allows a factor-of-two increase in the number of close Ly-alpha QSO pairs that can be observed. Echidna spine tilt causes a variable loss of throughput, with average loss being the same as the loss at the rms tilt. With a natural tilt minimization scheme, we find an rms tilt always close to 0.58 x maximum. There is an additional but much smaller defocus loss, equivalent to an average defocus of 30microns. These tilt losses offset the gains in yield for Echidna, but because the survey strategy is driven by the higher priority targets, a clear survey speed advantage remains. For 4MOST, high and low latitude sample mock catalogs were supplied by the 4MOST team, and allocations were carried out with the proposed Echidna-based positioner geometry. At high latitudes, the resulting target completeness was 85.3% for LR targets and 78.9% for HR targets. At low latitude, the target completeness was 93.9% for LR targets and 71.2% for HR targets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Room temperature multiplexed gas sensing using chemical-sensitive 3.5-nm-thin silicon transistors

There is great interest in developing a low-power gas sensing technology that can sensitively and selectively quantify the chemical composition of a target atmosphere. Nanomaterials have emerged as extremely promising candidates for this technology due to their inherent low-dimensional nature and high surface-to-volume ratio. Among these, nanoscale silicon is of great interest because pristine silicon is largely inert on its own in the context of gas sensing, unless functionalized with an appropriate gas-sensitive material. We report a chemical-sensitive field-effect transistor (CS-FET) platform based on 3.5-nm-thin silicon channel transistors. Using industry-compatible processing techniques, the conventional electrically active gate stack is replaced by an ultrathin chemical-sensitive layer that is electrically nonconducting and coupled to the 3.5-nm-thin silicon channel. We demonstrate a low-power, sensitive, and selective multiplexed gas sensing technology using this platform by detecting H 2 S, H 2 , and NO 2 at room temperature for environment, health, and safety in the oil and gas industry, offering significant advantages over existing technology. Moreover, the system described here can be readily integrated with mobile electronics for distributed sensor networks in environmental pollution mapping and personal air-quality monitors.

36 MATERIALS SCIENCE↗

Multiplexed CRISPR-Cas9 mutagenesis of rice PSBS1 noncoding sequences for transgene-free overexpression

Understanding CRISPR-Cas9’s capacity to produce native overexpression (OX) alleles would accelerate agronomic gains achievable by gene editing. To generate OX alleles with increased RNA and protein abundance, we leveraged multiplexed CRISPR-Cas9 mutagenesis of noncoding sequences upstream of the rice PSBS1 gene. We isolated 120 gene-edited alleles with varying non-photochemical quenching (NPQ) capacity in vivo—from knockout to overexpression—using a high-throughput screening pipeline. Overexpression increased OsPsbS1 protein abundance two- to threefold, matching fold changes obtained by transgenesis. Increased PsbS protein abundance enhanced NPQ capacity and water-use efficiency. Across our resolved genetic variation, we identify the role of 5'UTR indels and inversions in driving knockout/knockdown and overexpression phenotypes, respectively. Complex structural variants, such as the 252-kb duplication/inversion generated here, evidence the potential of CRISPR-Cas9 to facilitate significant genomic changes with negligible off-target transcriptomic perturbations. Our results may inform future gene-editing strategies for hypermorphic alleles and have advanced the pursuit of gene-edited, non-transgenic rice plants with accelerated relaxation of photoprotection.

60 APPLIED LIFE SCIENCES↗

Scalable multiplexed machine learning gas sensor chips for food classification

Multiplexed gas sensor arrays combined with machine learning have unlocked previously inaccessible applications for scent-based sensing. Current platforms are limited by overlapping sensing materials with similar compositions, leading to highly correlated responses, or multistep deposition processes that hinder scalability. In this work, we developed a 16-element monolithic chip with fully distinct sensing layers, enabling a truly heterogeneous array. The system consists of highly sensitive carbon nanotube field effect transistors that are functionalized through a single-step microdispensing method compatible with automated pipetting systems. The resulting chip produces characteristic signal patterns in response to object-specific scent profiles and, when combined with machine learning algorithms, can perform automated object identification. We demonstrate the classification of 16 different objects, including food spoilage and nut allergens, with a 92.6% overall prediction accuracy.

Bassil, Carla [University of California, Berkeley,↗

Improvement of the optical image reconstruction based on multiplexed quantum ghost images

Ghost imaging allows one to obtain information on an object from the spatial correlation function between photons propagating through or reflected from the object and photons of the reference arm. In this case, detection in the object arm is performed over the entire aperture of the beam and, therefore, it does not give information on the object. The reference beam does not interact with the object, but is recorded with a scanning point detector or a CCD array permitting the measurement of the spatial correlation function of photons in two arms. The use of multimode entangled quantum light beams by illuminating the object by one beam and orienting other beams to reference arms makes it possible to obtain simultaneously several ghost images (GIs). Cross correlations of multiplexed GIs (MGIs) are determined by eighth-order field correlation functions. A special algorithm is developed for calculating higher-order correlations of Bose operators. The presence of GI cross correlations is used for improving the quality of the reconstructed object’s image by their processing using the measurement reduction method. An example of the computer simulation of the image reconstruction by MGIs formed in the field of four-frequency entangled quantum states is considered. It is found that in this case the reduced GI has a signal-to-noise ratio several times higher than that of GIs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗