Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MPC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A Statistical Standard Siren Measurement of the Hubble Constant from the LIGO/Virgo Gravitational Wave Compact Object Merger GW190814 and Dark Energy Survey Galaxies

We present a measurement of the Hubble constant H 0 using the gravitational wave (GW) event GW190814, which resulted from the coalescence of a 23 M ⊙ black hole with a 2.6 M ⊙ compact object, as a standard siren. No compelling electromagnetic counterpart has been identified for this event; thus our analysis accounts for thousands of potential host galaxies within a statistical framework. The redshift information is obtained from the photometric redshift (photo- z ) catalog from the Dark Energy Survey. The luminosity distance is provided by the LIGO/Virgo gravitational wave sky map. Since this GW event has the second-smallest localization volume after GW170817, GW190814 is likely to provide the best constraint on cosmology from a single standard siren without identifying an electromagnetic counterpart. Furthermore, our analysis uses photo- z probability distribution functions and corrects for photo- z biases. We also reanalyze the binary black hole GW170814 within this updated framework. We explore how our findings impact the H 0 constraints from GW170817, the only GW merger associated with a unique host galaxy. From a combination of GW190814, GW170814, and GW170817, our analysis yields H 0 =72.0$_{+12}^{–8.2}$ km s -1 Mpc -1 (68% highest-density interval, HDI) for a prior in H 0 uniform between [20 and 140] km s -1 Mpc -1 . The addition of GW190814 and GW170814 to GW170817 improves the 68% HDI from GW170817 alone by ~18%, showing how well-localized mergers without counterparts can provide a significant contribution to standard siren measurements, provided that a complete galaxy catalog is available at the location of the event.

79 ASTRONOMY AND ASTROPHYSICS↗

The Most Distant H i Galaxies Discovered by the 500 m Dish FAST

Abstract Neutral hydrogen (Hi) is the primary component of the cool interstellar medium (ISM) and is the reservoir of fuel for star formation. Owing to the sensitivity of existing radio telescopes, our understanding of the evolution of the ISM in galaxies remains limited, as it is based on only a few hundred galaxies detected in Hibeyond the local Universe. With the high sensitivity of the Five-hundred-meter Aperture Spherical radio Telescope (FAST), we carried out a blind Hisearch, the FAST Ultra-Deep Survey, which extends to redshifts up to 0.42 and a sensitivity of 50μJy beam −1 . Here, we report the first discovery of six galaxies in Hi atz> 0.38. For these galaxies, the FAST angular resolution of ∼4′ corresponds to a mean linear size of ∼ 1.3 h 70 − 1 Mpc. These galaxies are among the most distant Hiemission detections known, with one having the most massive Hicontent ( 10 10.93 ± 0.04 h 70 − 2 M ⊙ ). Using recent data from the DESI survey and new observations with the Hale, Big Telescope Alt-azimuth, and Keck telescopes, optical counterparts are detected for all galaxies within the 3σpositional uncertainty ( 0.5 h 70 − 1 Mpc) and 200 km s −1 in recession velocity. Assuming that the dominant source of Hiis the identified optical counterpart, we find evidence of evolution in the Hicontent of galaxies over the last 4.2 Gyr. Our new high-redshift Higalaxy sample provides the opportunity to better investigate the evolution of cool gas in galaxies. A larger sample size in the future will allow us to refine our knowledge of the formation and evolution of galaxies.

Astronomy & Astrophysics↗

A Dark Siren Measurement of the Hubble Constant with the LIGO/Virgo Gravitational Wave Event GW190412 and DESI Galaxies

Abstract We present a measurement of the Hubble Constant H 0 using the gravitational wave event GW190412, an asymmetric binary black hole merger detected by LIGO/Virgo, as a dark standard siren. This event does not have an electromagnetic counterpart, so we use the statistical standard siren method and marginalize over potential host galaxies from the Dark Energy Spectroscopic Instrument (DESI) survey. GW190412 is well-localized to 12 deg 2 (90% credible interval), so it is promising for a dark siren analysis. The dark siren value for H 0 = 85.4 − 33.9 + 29.1 km s −1 Mpc −1 , with a posterior shape that is consistent with redshift overdensities. When combined with the bright standard siren measurement from GW170817 we recover H 0 = 77.96 − 5.03 + 23.0 km s −1 Mpc −1 , consistent with both early and late-time Universe measurements of H 0 . This work represents the first standard siren analysis performed with DESI data, and includes the most complete spectroscopic sample used in a dark siren analysis to date.

Ballard, W.↗

Investigating lab-scaled offshore wind aerodynamic testing failure and developing solutions for early anomaly detections

As offshore wind systems become more complex, the risk of human error or equipment malfunction increases during experimental testing. This study investigates a lab-scale incident involving a 1 : 50 scale 5 MW wind turbine, where a generator failure led to rotor overspeed and a blade–tower strike. To improve early fault detection, we propose a data-driven method based on multivariate long short-term memory (LSTM) models. High-frequency measurements are projected onto principal components, and anomalies are identified using reconstruction error and its time derivative. Two models are trained on different healthy datasets and tested using single- and multi-principal component (1PC and MPC) variations. Results show that combining both error and error derivative improves detection accuracy. The 1PC model detects faults faster, has a higher recall rate, and achieves a 43 % improvement in anomaly detection accuracy, while the MPC model yields higher precision. This approach provides a simple and effective tool for early anomaly detection in lab-scale experiments, helping to reduce the risk of future failures during the testing of new technologies.

17 WIND ENERGY↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Navy Ratchets Up Resilience Through Agency/Utility Collaboration

Fact sheet describes how the Naval Construction Battalion Center (NCBC) in Gulfport, Mississippi, and Mississippi Power Company (MPC) have integrated a 15-acre solar photovoltaic (PV) array, battery storage, and backup generation with an innovative microgrid to ensure mission readiness at NCBC while increasing renewable energy generation on the grid in MPC's service area. The NCBC/MPC resilience effort will allow the base to more effectively deploy disaster recovery activities in the event of a grid outage.

battery storage↗

DECENTRALIZED APPROACH TO MULTI-ZONE GREY-BOX MODELING FOR MODEL-BASED PREDICTIVE CONTROL

This study aims to improve the easiness of utilizing the grey-box model (i.e., Resistance-Capacitance circuit) for Model-based Predictive Control (MPC). The primary barrier of implementing the MPC is estimating the control-oriented building model that needs to be computationally inexpensive and quick but reasonably precise in predicting building load and indoor conditions. The estimating of the model parameters becomes more complicated when the building scale is larger; e.g., multi-zone building. In this study, a decentralized approach is introduced; each zone is split and individually estimated with measured boundary temperature from adjacent zones integrated into one single system model. The proposed decentralized method is demonstrated with experimental data from a full-scale multi-zone test cell compared with the centralized reference case.

Joe, Jaewan↗

Restoring Distribution System Under Renewable Uncertainty Using Reinforcement Learning: Preprint

Distributed energy resources (DER) in distribution systems, including renewable generation, micro-turbine, and energy storage, can be used to restore critical loads following extreme events to increase grid resiliency. However, properly coordinating multiple DERs in the system for multi-step restoration process under renewable uncertainty and fuel availability is a complicated sequential optimal control problem. Due to its capability to handle system non-linearity and uncertainty, reinforcement learning (RL) stands out as a potentially powerful candidate in solving complex sequential control problems. Moreover, the offline training of RL provides excellent action readiness during online operation, making it suitable to problems such as load restoration, where in-time, correct and coordinated actions are needed. In this study, a distribution system prioritized load restoration based on a simplified single-bus system is studied: with imperfect renewable generation forecast, the performance of an RL controller is compared with that of a deterministic model predictive control (MPC). Our experiment results show that the RL controller is able to learn from experience, adapt to the imperfect forecast information and provide a more reliable restoration process when compared with the baseline MPC controller.

61 RADIATION PROTECTION AND DOSIMETRY↗

Restoring Distribution System Under Renewable Uncertainty Using Reinforcement Learning

Distributed energy resources (DER) in distribution systems, including renewable generation, micro-turbine, and energy storage, can be used to restore critical loads following extreme events to increase grid resiliency. However, properly coordinating multiple DERs in the system for multi-step restoration process under renewable uncertainty and fuel availability is a complicated sequential optimal control problem. Due to its capability to handle system non-linearity and uncertainty, reinforcement learning (RL) stands out as a potentially powerful candidate in solving complex sequential control problems. Moreover, the offline training of RL provides excellent action readiness during online operation, making it suitable to problems such as load restoration, where in-time, correct and coordinated actions are needed. In this study, a distribution system prioritized load restoration based on a simplified single-bus system is studied: with imperfect renewable generation forecast, the performance of an RL controller is compared with that of a deterministic model predictive control (MPC). Our experiment results show that the RL controller is able to learn from experience, adapt to the imperfect forecast information and provide a more reliable restoration process when compared with the baseline MPC controller.

61 RADIATION PROTECTION AND DOSIMETRY↗

Model Predictive Control of Dual-Mode Energy-Stored Quasi-Z-Source Photovoltaic System

The energy-stored quasi-Z-source inverter (ES-qZSI) has attracted much attention for photovoltaic (PV) power generations, due to its capability to stabilize the PV power fluctuations and other advantages of Z-source inverter. Traditional ES-qZSI suffers from poor operation at night or cloudy days when PV power is extremely low. In order to overcome that, this paper proposes a model predictive control (MPC) strategy for an improved dual-mode ES-qZSI, which is designed to support all-weather operation of PV power generation system. The system predictive models in both day and night operating modes are derived. And the control strategy based on MPC is disclosed to ensure the high-performance operation of the system. Simulation is carried out on PV power fluctuation in daytime and switching between the two modes, to verify the effectiveness of proposed control strategy.

Xue, Yaosuo↗

Model predictive control for matrix converter operating in current control mode with load current estimation

A matrix converter system operating in current control mode is provided. The matrix converter includes a switching matrix coupled between a low voltage side and a high voltage side, wherein the matrix converter is coupled at its low voltage side to a generator for receiving an input power including an input current and transforming the input power into an output power at its high voltage side, wherein a load is coupled to the high voltage side. The control system includes a load observer and a model predictive controller (MPC). The load observer is configured to estimate a load current that flows to the load from the high voltage side of the matrix converter as a function of a switching state of the switching matrix, an output voltage output at the high voltage side of the matrix converter, and the input current. The MPC is configured to select the switching state of the switching matrix to meet one or more control objectives defined by minimization of a multi-objective function that tracks the output voltage and the input current using the estimated load current.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transient Efficiency, Flexibility, and Reliability Optimization of Coal-Fired Power Plants - Final Program Review

This program developed an advanced model-based monitoring and model-predictive control algorithms for a coal fired power plant (CFPP), and deployed these algorithms in a real-time platform to demonstrate performance benefits for transient flexibility and plant operation efficiency. More specifically, the objectives were successfully achieved through a combination of (i) developing a high-fidelity transient plant model in Apros, which was used as a high-fidelity plant simulation between $100-50\% TMCR$ where TMCR denotes the turbine maximum continuous rating, i.e., baseload, (ii) developing a very fast physics-based reduced-order model (ROM) of the plant, which ran more than $100\times$ faster than real-time, enabling its use as real-time embedded model for model-based estimation (MBE) and model predictive control (MPC) (iii) implementing a real-time MBE based on ROM using a robust unscented Kalman filter (UKF) to continuously tune the ROM to match the measurements from high-fidelity Apros plant model despite significant plant-model mismatch, and thus, obtain a Digital Twin of the plant (iv) designing and implementing a real-time MPC with dual objectives of transient plant load tracking with high ramp rates and minimizing coal consumption, i.e., improving plant efficiency in the baseload-partload operation range of $100-50\% TMCR$. Each key element above was developed and tested individually, and has been reported in corresponding Topical Reports. Finally, all the individual elements were integrated in an overall closed-loop system, that was successfully tested in desktop Simulink test harness simulations with ROM or high-fidelity model as the plant. Thereafter, the Simulink implementation was used to auto-generate C-code and deploy as real-time Docker microservice containers in Linux, and validate that they can run in real-time in the hardware-in-the loop (HIL) setup and produce the same results as in Simulink. The results of the integrated simulation tests in Simulink as well as the real-time HIL deployment are documented in this final report, showing good load tracking for load ramps at $3-4\%/min$ ramp rates, and achieving up to $5.5\%$ reduction in coal relative to baseline operation at $50\% TMCR$ load. The desktop and HIL simulations show successful performance of the overall model based estimation and control solution and achieve the key objectives of the program for flexible, efficient and reliable operation of sub-critical coal fired power plants.

20 FOSSIL-FUELED POWER PLANTS↗

Multi-Fidelity Modeling and Control for Building Temperature Control

The ability to control energy loads such as a building's heating, ventilation, and air conditioning (HVAC) system can help facilitate increased penetration of variable renewable energy sources into the electric grid. To be able to control these HVAC systems more effectively, detailed simulations of the corresponding building physics is becoming increasingly important. These detailed simulations can be complex, nonlinear, and can require immense computational power when used in an advanced control method such as model predictive control (MPC), prompting the need to explore less computationally intensive strategies. In this work, a multi-fidelity approach is proposed to combine samples from a complex, high-fidelity model with a simple, low-fidelity model within the MPC control loop. More specifically, the parameters of a reduced-order, linear building model are periodically updated with knowledge from its high-fidelity counterpart - an EnergyPlus model - in an online fashion using a Gaussian Process surrogate model. Hence, highly accurate predictions of current and future conditions in a building are maintained with a substantially reduced computational burden compared to using the high-fidelity models alone. In other words, this linear parameter varying model preserves the low computational requirements of a low-order linear model while accurately modeling a building's dynamics. This allows a building controller to take highly informed actions without requiring a large computational budget.

building modeling↗

Reinforcement Learning to Enhance Optimal Operation of Resilient Community Energy Systems

This paper presents a novel model-free multi-agent Reinforcement Learning (RL) control method to enhance the resilience of community energy systems in island mode, which coordinates multiple objectives without the necessity of identifying system models that require expert knowledge. Specifically, a community-level coordinator agent is designed to allocate renewable energy resources among different buildings, and multiple building-level agents are developed to optimize load schedules based on limited energy resources and requirements of building loads and occupants’ comfort. In a two-day evaluation, our RL approach demonstrated a similar performance against MPC without requiring system models and formulation of optimization problems as required in MPC.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

FLAW STABILITY ANALYSIS OF SURFACE CRACKS IN DOE STANDARD CANISTERS UNDER OPERATION LOADS AND WELDING RESIDUAL STRESSES

There are over 3000 commercial spent nuclear fuel (SNF) storage canisters that are made of stainless steel and planned for multi-purpose functions of SNF handling: interim storage, transportation, and ultimate disposal at a future SNF disposition location. To date, many multi-purpose canisters (MPC) are located in coastal regions for long-term storage. The canisters are fabricated by welding, and post-welding heat treatment is not required for relieving welding residual stresses (WRS). As a result, these canisters may be susceptible to chloride induced stress corrosion cracking (CISCC) due to the chloride-bearing marine salts. The flaw stability analysis of MPC canisters was performed at SRNL (i.e., PVP2016-4935 and PVP2016-63887) for through-wall flaws and for surface flaws respectively, where WRS was considered, and the failure assessment diagram (FAD)-based fracture mechanics method codified by API 579-1/ASME FFS-1-2007 Edition was adopted.

DOE standard canister↗

DESI DR1 Ly$α$ forest: 3D full-shape analysis and cosmological constraints

We perform an analysis of the full shapes of Lyman-$α$ (Ly$α$) forest correlation functions measured from the first data release (DR1) of the Dark Energy Spectroscopic Instrument (DESI). Our analysis focuses on measuring the Alcock-Paczynski (AP) effect and the cosmic growth rate times the amplitude of matter fluctuations in spheres of $8$$h^{-1}\text{Mpc}$, $fσ_8$. We validate our measurements using two different sets of mocks, a series of data splits, and a large set of analysis variations, which were first performed blinded. Our analysis constrains the ratio $D_M/D_H(z_\mathrm{eff})=4.525\pm0.071$, where $D_H=c/H(z)$ is the Hubble distance, $D_M$ is the transverse comoving distance, and the effective redshift is $z_\mathrm{eff}=2.33$. This is a factor of $2.4$ tighter than the Baryon Acoustic Oscillation (BAO) constraint from the same data. When combining with Ly$α$ BAO constraints from DESI DR2, we obtain the ratios $D_H(z_\mathrm{eff})/r_d=8.646\pm0.077$ and $D_M(z_\mathrm{eff})/r_d=38.90\pm0.38$, where $r_d$ is the sound horizon at the drag epoch. We also measure $fσ_8(z_\mathrm{eff}) = 0.37\; ^{+0.055}_{-0.065} \,(\mathrm{stat})\, \pm 0.033 \,(\mathrm{sys})$, but we do not use it for cosmological inference due to difficulties in its validation with mocks. In $Λ$CDM, our measurements are consistent with both cosmic microwave background (CMB) and galaxy clustering constraints. Using a nucleosynthesis prior but no CMB anisotropy information, we measure the Hubble constant to be $H_0 = 68.3\pm 1.6\;\,{\rm km\,s^{-1}\,Mpc^{-1}}$ within $Λ$CDM. Finally, we show that Ly$α$ forest AP measurements can help improve constraints on the dark energy equation of state, and are expected to play an important role in upcoming DESI analyses.

Cuceu, Andrei [LBL, Berkeley; Chicago U., KICP] (O↗

Cosmological Constraints from Full-Scale Clustering and Galaxy-Galaxy Lensing with DESI DR1

We present constraints on cosmic structure growth from the analysis of galaxy clustering and galaxy-galaxy lensing with galaxies from the Dark Energy Spectroscopic Instrument (DESI) Data Release 1. We analyze four samples drawn from the Bright Galaxy Survey (BGS) and the Luminous Red Galaxy (LRG) target classes. Projected galaxy clustering measurements from DESI are supplemented with lensing measurements from the Dark Energy Survey (DES), the Kilo-Degree Survey (KiDS), and the Hyper Suprime-Cam (HSC) survey around the same targets. Our method relies on a simulation-based modeling framework using the AbacusSummit simulations and a complex halo occupation distribution model that incorporates assembly bias. We analyze scales down to $0.4 \, h^{-1} \, \mathrm{Mpc}$ for clustering and $2.5 \, h^{-1} \, \mathrm{Mpc}$ for lensing, leading to stringent constraints on $S_8 = σ_8 \sqrt{Ω_\mathrm{m} / 0.3}$ and $Ω_\mathrm{m}$ when fixing other cosmological parameters to those preferred by the CMB. We find $S_8 = 0.794 \pm 0.023$ and $Ω_\mathrm{m} = 0.295 \pm 0.012$ when using lensing measurements from DES and KiDS. Similarly, for HSC, we find $S_8 = 0.793 \pm 0.017$ and $Ω_\mathrm{m} = 0.303 \pm 0.010$ when assuming the best-fit photometric redshift offset suggested by the HSC collaboration. Overall, our results are in good agreement with other results in the literature while continuing to highlight the constraining power of non-linear scales.

Lange, Johannes U. [American U.] (ORCID:0000000224↗

Dark Energy Survey Year 6 Results: Galaxy-galaxy lensing

We present galaxy--galaxy lensing (GGL) measurements from the full six years of data from the Dark Energy Survey (DES Y6), covering $4031\,\mathrm{deg}^2$ and used in the DES Y6 $3\times2$pt cosmological analysis. We use the MagLim++ lens sample, containing $\sim 9$ million galaxies divided into six redshift bins, and the Metadetection source catalog, including $\sim 140$ million galaxies divided into four redshift bins. The mean tangential shear signal achieves a total signal-to-noise ratio (S/N) of $173$, corresponding to a $17\%$ improvement over DES Y3. After applying the scale cuts used in the cosmological analysis, with $R_{\min}=6\,\mathrm{Mpc}/h$ ($4\,\mathrm{Mpc}/h$) for the linear (nonlinear) galaxy-bias model, the S/N is reduced to $75$ (90). A comprehensive suite of validation tests demonstrates that the measurement is robust against observational and astrophysical systematics at the statistical precision required for the DES Y6 analysis. Although not used in the main cosmological analysis, we extract high--signal-to-noise geometric shear-ratio measurements from the galaxy--galaxy lensing signal on small angular scales. These measurements provide an internal consistency check on the photometric redshift distributions and shear calibration used in the $3\times2$pt analysis.

Giannini, G. [Barcelona, IEEC; Chicago U., KICP; B↗