At least 325 records · Page 18

Seeded quantum FEL at 478 keV

We present for the first time the concept of a seeded {gamma} quantum Free-Electron-Laser (QFEL) at 478 keV, which has very different properties compared to a classical. The basic concept is to produce a highly brilliant {gamma} beam via SASE. To produce highly intense and coherent {gamma} beam, we intend to use a seeded FEL scheme. Important for the production of such a {gamma} beam are novel refractive {gamma}-lenses for focusing and an efficient monochromator, allowing to generate a very intense and coherent seed beam. The energy of the {gamma} beam is 478 keV, corresponding to a wavelength in the sub-Angstrom regime (1/38 A). To realize a coherent {gamma} beam at 478 keV, it is necessary to use a quantum FEL design. At such high radiation energies a classical description of the {gamma}-FEL becomes wrong.

43 PARTICLE ACCELERATORS↗

A beam intensity monitor for the evaluation beamline for soft x-ray optical elements

Evaluation Beamline for Soft X-Ray Optical Elements (BL-11) at the SR Center of Ritsumeikan University has been operated to measure the wavelength and angular characteristics of soft x-ray optical components in a wavelength range of 0.65-25 nm using a reflecto-diffractometer (RD). The beam intensity monitor that has been equipped in BL-11 has observed the signal of the zero-th order light. For the purpose of more accurate evaluation of the performance of optical components, a new beam intensity monitor to measure the intensity of the first order light from the monochromator in BL-11 has been developed and installed in just front of RD. The strong positive correlation between the signal of the beam monitor and a detector equipped in the RD is shown. It is successful that the beam intensity of the first order light can be monitored in real time.

43 PARTICLE ACCELERATORS↗

A new double imaging velocity focusing coincidence experiment: i{sup 2}PEPICO

The vacuum ultraviolet (VUV) beamline of the Swiss Light Source has been upgraded after two years of operation. A new, turntable-type monochromator was constructed at the Paul Scherrer Institut, which allows for fast yaw-alignment as well as quick grating change and exchange. In addition to the original imaging photoelectron photoion coincidence endstation (iPEPICO), a second, complementary double imaging setup (i{sup 2}PEPICO) has been built. Volatile samples can be introduced at room temperature or in a molecular beam, a pyrolysis source allows for radical production, and non-volatile solids can be evaporated in a heated cell. Monochromatic VUV radiation ionizes the sample and both photoelectrons and photoions are velocity map imaged onto two fast position sensitive detectors and detected in delayed coincidence. High intensity synchrotron radiation leads to ionization rates above 10{sup 5} s{sup -1}. New data acquisition and processing approaches are discussed for recording coincidence processes at high rates. The setup is capable of resolving pulsed molecular beam profiles and the synchrotron time structure temporally. The latter is shown by photoelectron autocorrelation, which displays both the 1.04 MHz ring clock frequency as well as resolving the micro-pulses with a separation of 2 ns. Kinetic energy release analysis on the dissociative photoionization of CF{sub 4} indicates a dissociation mechanism change in the Franck-Condon allowed energy range of the first ion state.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active diffraction gratings: Development and tests

We present the realization and characterization of an active spherical diffraction grating with variable radius of curvature to be used in grazing-incidence monochromators. The device consists of a bimorph deformable mirror on the top of which a diffraction grating with laminar profile is realized by UV lithography. The experimental results show that the active grating can optimize the beam focalization of visible wavelengths through its rotation and focus accommodation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of soft x-ray/VUV transmission characteristics of Si and Al filters

Ultrathin filters of Al (1500A) and Si (1200A) should exhibit more than 65% transmission above their Labsorption edges in the soft x-ray/vacuum ultra violet region(Si L-edge: 124 A and Al L-edge: 170 A). However, the measured transmission characteristics of these filters showed {approx}40% transmission. The transmission measurements of these filters were carried at the reflectivity beamline of Indus-1 synchrotron source out over a large wavelength range of 120-360A. In order to understand the measured transmission performance a detailed model fitting is performed using the Paratt formalism. It is found that the oxidation of the surface region of the filters is responsible for the reduced transmission performance. Effects of higher harmonics of the toroidal grating monochromator are also considered in the data analysis.

36 MATERIALS SCIENCE↗

A seven-crystal Johann-type hard x-ray spectrometer at the Stanford Synchrotron Radiation Lightsource

We present a multicrystal Johann-type hard x-ray spectrometer ({approx}5-18 keV) recently developed, installed, and operated at the Stanford Synchrotron Radiation Lightsource. The instrument is set at the wiggler beamline 6-2 equipped with two liquid nitrogen cooled monochromators - Si(111) and Si(311) - as well as collimating and focusing optics. The spectrometer consists of seven spherically bent crystal analyzers placed on intersecting vertical Rowland circles of 1 m of diameter. The spectrometer is scanned vertically capturing an extended backscattering Bragg angular range (88 Degree-Sign -74 Degree-Sign ) while maintaining all crystals on the Rowland circle trace. The instrument operates in atmospheric pressure by means of a helium bag and when all the seven crystals are used (100 mm of projected diameter each), has a solid angle of about 0.45% of 4{pi} sr. The typical resolving power is in the order of (E/{Delta}E){approx}10 000. The spectrometer's high detection efficiency combined with the beamline 6-2 characteristics permits routine studies of x-ray emission, high energy resolution fluorescence detected x-ray absorption and resonant inelastic x-ray scattering of very diluted samples as well as implementation of demanding in situ environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high-order harmonic generation apparatus for time- and angle-resolved photoelectron spectroscopy

We present a table top setup for time- and angle-resolved photoelectron spectroscopy to investigate band structure dynamics of correlated materials driven far from equilibrium by femtosecond laser pulse excitation. With the electron-phonon equilibration time being in the order of 1–2 ps it is necessary to achieve sub-picosecond time resolution. Few techniques provide both the necessary time and energy resolution to map non-equilibrium states of the band structure. Laser-driven high-order harmonic generation is such a technique. In our experiment, a grating monochromator delivers tunable photon energies up to 40 eV. A photon energy bandwidth of 150 meV and a pulse duration of 100 fs FWHM allow us to cover the k-space necessary to map valence bands at different k{sub z} and detect outer core states.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A monolithic polarization-independent frequency-filter system for filtering of photon pairs

We set up a long-term stable filtering system that consists of cascaded monolithic Fabry-Pérot filters to enhance the suppression and free spectral range. An effective free spectral range of hundreds of GHz allows the system to be used as a high resolution monochromator, with a linewidth of 192 MHz. As an important application a single mode is filtered from photon pairs generated by a parametric down-conversion source, and their indistinguishability is proven by measuring the Hong-Ou-Mandel effect with a visibility of 96%. We report that undesired birefringence, which is often encountered with monolithic cavities, can be avoided by stress-free mounting.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Commissioning and first results of scanning type EXAFS beamline (BL-09) at INDUS-2 synchrotron source

An Energy Scanning X-ray Absorption Fine Structure spectroscopy beamline has recently been installed and commissioned at BL-09 bending magnet port of INDUS-2 synchrotron source, Indore. The beamline uses an UHV compatible fixed exit double crystal monochromator (DCM) with two Si (111) crystals. Two grazing incidence cylindrical mirrors are also used in this beamline; the pre-mirror is used as a collimating mirror while the post mirror is used for vertical focusing and higher harmonic rejection. In this beamline it is possible to carry out EXAFS measurements both in transmission and fluorescence mode on various types of samples, using Ionization chamber detectors and solid state drift detector respectively. In this paper, results from first experiments of the Energy Scanning EXAFS beamline are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of soft X-ray polarized light beamline on Indus-2 synchrotron radiation source

This article describes the development of a soft x-ray beamline on a bending magnet source of Indus-2 storage ring (2.5 GeV) and some preliminary results of x-ray absorption spectroscopy (XAS) measurements using the same. The beamline layout is based on a spherical grating monochromator. The beamline is able to accept synchrotron radiation from the bending magnet port BL-1 of the Indus-2 ring with a wide solid angle. The large horizontal and vertical angular acceptance contributes to high photon flux and selective polarization respectively. The complete beamline is tested for ultrahigh vacuum (UHV) ∼ 10{sup −10} mbar. First absorption spectrum was obtained on HOPG graphite foil. Our performance test indicates that modest resolving power has been achieved with adequate photon flux to carry out various absorption experiments.

43 PARTICLE ACCELERATORS↗

Study on higher harmonic suppression using edge filter and polished Si wafer

Higher harmonics contamination is a severe problem in synchrotron beamlines where grating monochromators are used. In these beamlines, absorption edge filters and critical angle mirrors are used to suppress the harmonic contaminations. In the present study, carried out using Indus-1 reflectivity beamline, a harmonic suppression characteristic of Al edge filter and polished silicon wafer are determined. It is found that the Al filter suppresses higher harmonics in 2–7% range whereas the polished silicon wafer can suppress the higher harmonics below 1%. The results of comparative study are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spectrometer for shot-to-shot photon energy characterization in the multi-bunch mode of the free electron laser at Hamburg

The setup and first results from commissioning of a fast online photon energy spectrometer for the vacuum ultraviolet free electron laser at Hamburg (FLASH) at DESY are presented. With the use of the latest advances in detector development, the presented spectrometer reaches readout frequencies up to 1 MHz. In this paper, we demonstrate the ability to record online photon energy spectra on a shot-to-shot base in the multi-bunch mode of FLASH. Clearly resolved shifts in the mean wavelength over the pulse train as well as shot-to-shot wavelength fluctuations arising from the statistical nature of the photon generating self-amplified spontaneous emission process have been observed. In addition to an online tool for beam calibration and photon diagnostics, the spectrometer enables the determination and selection of spectral data taken with a transparent experiment up front over the photon energy of every shot. This leads to higher spectral resolutions without the loss of efficiency or photon flux by using single-bunch mode or monochromators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nano-metrology: The art of measuring X-ray mirrors with slope errors <100 nrad

We present a comprehensive investigation of the systematic and random errors of the nano-metrology instruments used to characterize synchrotron X-ray optics at Diamond Light Source. With experimental skill and careful analysis, we show that these instruments used in combination are capable of measuring state-of-the-art X-ray mirrors. Examples are provided of how Diamond metrology data have helped to achieve slope errors of <100 nrad for optical systems installed on synchrotron beamlines, including: iterative correction of substrates using ion beam figuring and optimal clamping of monochromator grating blanks in their holders. Simulations demonstrate how random noise from the Diamond-NOM’s autocollimator adds into the overall measured value of the mirror’s slope error, and thus predict how many averaged scans are required to accurately characterize different grades of mirror.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a spectroscopic Mueller matrix imaging ellipsometer for nanostructure metrology

In this paper, we describe the development of a spectroscopic Mueller matrix imaging ellipsometer (MMIE), which combines the great power of Mueller matrix ellipsometry with the high spatial resolution of optical microscopy. A dual rotating-compensator configuration is adopted to collect the full 4 × 4 imaging Mueller matrix in a single measurement. The light wavelengths are scanned in the range of 400–700 nm by a monochromator. The instrument has measurement accuracy and precision better than 0.01 for all the Mueller matrix elements in both the whole image and the whole spectral range. The instrument was then applied for the measurement of nanostructures combined with an inverse diffraction problem solving technique. The experiment performed on a photoresist grating sample has demonstrated the great potential of MMIE for accurate grating reconstruction from spectral data collected by a single pixel of the camera and for efficient quantification of geometrical profile of the grating structure over a large area with pixel resolution. It is expected that MMIE will be a powerful tool for nanostructure metrology in future high-volume nanomanufacturing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical design of the ARAMIS-beamlines at SwissFEL

SwissFEL is a free electron laser facility for hard and soft X-rays at the Paul Scherrer Institut in Switzerland. The first hard X-ray FEL named ARAMIS will deliver photons in the wavelength range from 1 Å to 7 Å in up to three beamlines alternatively. The beamlines are equipped with crystal monochromators, cover the full wavelength range and offer a variety of operational modes.

43 PARTICLE ACCELERATORS↗

NSLS-II biomedical beamlines for micro-crystallography, FMX, and for highly automated crystallography, AMX: New opportunities for advanced data collection

We present the final design of the x-ray optics and experimental stations of two macromolecular crystallography (MX) beamlines at the National Synchrotron Light Source-II. The microfocusing FMX beamline will deliver a flux of ∼5×10{sup 12} ph/s at 1 Å into a 1 – 20 µm spot, its flux density surpassing current MX beamlines by up to two orders of magnitude. It covers an energy range from 5 – 30 keV. The highly automated AMX beamline is optimized for high throughput, with beam sizes from 4 – 100 µm, an energy range of 5 – 18 keV and a flux at 1 Å of ∼10{sup 13} ph/s. A focus in designing the beamlines lay on achieving high beam stability, for example by implementing a horizontal bounce double crystal monochromator at FMX. A combination of compound refractive lenses and bimorph mirror optics at FMX supports rapid beam size changes. Central components of the in-house developed experimental stations are horizontal axis goniometers with a target sphere of confusion of 100 nm, piezo-slits for dynamic beam size changes during diffraction experiments, dedicated secondary goniometers for data collection from specimen in crystallization plates, and next generation pixel array detectors. FMX and AMX will support a broad range of biomedical structure determination methods from serial crystallography on micron-sized crystals, to structure determination of complexes in large unit cells, to rapid sample screening and room temperature data collection of crystals in trays.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High resolution, monochromatic x-ray topography capability at CHESS

CHESS has a monochromatic x-ray topography capability serving continually expanding user interest. The setup consists of a beam expanding monochromator, 6-circle diffactometer, and CHESS designed CMOS camera with real time sample-alignment capability. This provides rocking curve mapping with angle resolution as small as 2 µradians, spatial resolution to 3 microns, and field of view up to 7mm. Thus far the capability has been applied for: improving CVD-diamond growth, evaluating perfection of ultra-thin diamond membranes, correlating performance of diamond-based electronics with crystal defect structure, and defect analysis of single crystal silicon carbide. This paper describes our topography system, explains its capabilities, and presents experimental results from several applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Construction and performance of combustion beamline at NSRL

An undulator-based VUV beamline BL03U is constructed at the National Synchrotron Radiation Laboratory. Optical design and performance test results are presented in this paper. The monochromator is a Czerny–Turner configuration with a toroidal collimating mirror, two plane gratings, and a toroidal focusing mirror. Plane gratings with line densities of 200 and 400 l/mm are used to cover the photon energy range of 5–21 eV. A gas absorption spectrum is used to evaluate the beamline performance. The photon energy resolving power (E/ΔE) of the beamline is approximately 3900 at 7.3 eV for the 200 l/mm grating and 4200 at 14.6 eV for the 400 l/mm grating. The photon flux is approximately 5×10{sup 12} photons/s/300 mA at energy of 10 eV.

43 PARTICLE ACCELERATORS↗