Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ML”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Guide for SDEC Set up

The instrument has four collection vials that must be filled with ethylene glycol before operation. Each of the four vials should be labeled 1 through 4 and the empty weights recorded. Fill each vial with 80 mL of ethylene glycol and record the weight again. In order for the instrument to operate properly, the collection vials should always have less than 160 mL of total liquid in them. After completing a sample run, remove the collection vials, use a transfer pipette to remove any liquid that might still be on the air paddler, wipe off any condensation from the exterior of the collection vial and record weight. From the instrument, record the ending volume and the time of operation. The solution mixed in the scintillation vial will be 2 ml of a 95% to 50% ethylene glycol to water mixture. To determine the efficiency of counting at all of these concentrations, a series of vials should be set up that consist of 18 ml of Ultima Gold LLT cocktail mixed with standard, regular deionized water and ethylene glycol. The efficiency curve should be counted in the 'Low Level' count mode with the Luminescence Correction ON and the Color Quench Correction ON. Once the tSIE values are determined, chart the cpm against the tSIE numbers and find the best fit for the data. The resulting equation is to be used to converting tSIE values from the collection vials to efficiency. To determine the background cpm value of the ethylene glycol, count a 2 ml sample of ethylene glycol with 18 ml of Ultima Gold for 100 minutes. To determine the total activity of the sample, take two 2 ml aliquots of sample from the first vial and place in separate scintillation vials. Record the weight of each aliquot. Determine the percentage of total sample each aliquot represents by dividing the aliquot weight by the total solution weight from the vial. Also, determine the percentage of ethylene glycol in the sample by dividing the initial solution weight by the final solution weight and multiplying by 100. Add 18 ml of Ultima Gold to each vial and proceed to count for 100 minutes in a 'Low Level' count mode. Before performing a calculation on the dpm value of each aliquot, a subtraction should be made for the background count rate of the ethylene glycol. Based on the background cpm, multiply the background cpm value by the percentage of ethylene glycol in the collection vial. Once the background value is subtracted, calculate the dpm value of the sample based on the tSIE conversion to efficiency. This will produce a dpm value. To convert this to a total activity of the sample, divide the aliquot dpm value by the decimal percentage of total sample the aliquot represents. This gives the total activity of the sample solution. Take the average of both aliquots as a final result. To convert the total activity from the solution in vial one to activity in air, an empirical formula is used to convert activity/gram from vial one to total activity introduced into the system. After calculation the final result for the vial, divide the total by the mass of the sample in vial one. This gives dpm/g (labeled C{sub m}). To convert this to total dpm measured, C = (128.59 * Cm + 10.837)/V Where: C = Tritium concentration in air (dpm/m{sup 3}) C{sub m} = measured tritium concentration from vial 1 (dpm/g) V = Volume of air sampled through instrument (m{sup 3}). C is the final value of tritium concentration in air.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Cognitive Effects of Machine Learning Aid in Domain-Specific and Domain-General Tasks.

With machine learning (ML) technologies rapidly expanding to new applications and domains, users are collaborating with artificial intelligence-assisted diagnostic tools to a larger and larger extent. But what impact does ML aid have on cognitive performance, especially when the ML output is not always accurate? Here, we examined the cognitive effects of the presence of simulated ML assistance—including both accurate and inaccurate output—on two tasks (a domain-specific nuclear safeguards task and domain-general visual search task). Patterns of performance varied across the two tasks for both the presence of ML aid as well as the category of ML feedback (e.g., false alarm). These results indicate that differences such as domain could influence users’ performance with ML aid, and suggest the need to test the effects of ML output (and associated errors) in the specific context of use, especially when the stimuli of interest are vague or ill-defined

97 MATHEMATICS AND COMPUTING↗

Replicating Machine Learning Experiments in Materials Science

Transparency and reproducibility are important aspects of validation for Machine Learning (ML) models that are not fully understood and applies independently of the application domain.We offer a case study of reproducibility that highlights the challenges encountered when attempting to reproduce analyzes obtained with Machine Learning methods in materials informatics. Our study explores prediction results obtained with ML models and issues in training data serving as input. We discuss challenges related to theory-driven and numerical errors in training data, lack of reproducibility across platforms and versions, and effects of randomness when varying hyperparameters. In addition to model accuracy, a main metric of interest in the ML community, our results show that model sensitivity may be equally important for applying ML in domain applications such a materials science.

97 MATHEMATICS AND COMPUTING↗

A Fortran–Python interface for integrating machine learning parameterization into earth system models

Abstract. Parameterizations in earth system models (ESMs) are subject to biases and uncertainties arising from subjective empirical assumptions and incomplete understanding of the underlying physical processes. Recently, the growing representational capability of machine learning (ML) in solving complex problems has spawned immense interests in climate science applications. Specifically, ML-based parameterizations have been developed to represent convection, radiation, and microphysics processes in ESMs by learning from observations or high-resolution simulations, which have the potential to improve the accuracies and alleviate the uncertainties. Previous works have developed some surrogate models for these processes using ML. These surrogate models need to be coupled with the dynamical core of ESMs to investigate the effectiveness and their performance in a coupled system. In this study, we present a novel Fortran–Python interface designed to seamlessly integrate ML parameterizations into ESMs. This interface showcases high versatility by supporting popular ML frameworks like PyTorch, TensorFlow, and scikit-learn. We demonstrate the interface's modularity and reusability through two cases: an ML trigger function for convection parameterization and an ML wildfire model. We conduct a comprehensive evaluation of memory usage and computational overhead resulting from the integration of Python codes into the Fortran ESMs. By leveraging this flexible interface, ML parameterizations can be effectively developed, tested, and integrated into ESMs.

54 ENVIRONMENTAL SCIENCES↗

A Fortran-Python Interface for Integrating Machine Learning Parameterization into Earth System Models

Parameterizations in Earth System Models (ESMs) are subject to biases and uncertainties arising from subjective empirical assumptions and incomplete understanding of the underlying physical processes. Recently, the growing representational capability of machine learning (ML) in solving complex problems has spawned immense interests in climate science applications. Specifically, ML-based parameterizations have been developed to represent convection, radiation and microphysics processes in ESMs by learning from observations or high-resolution simulations, which have the potential to improve the accuracies and alleviate the uncertainties. Previous works have developed some surrogate models for these processes using ML. These surrogate models need to be coupled with the dynamical core of ESMs to investigate the effectiveness and their performance in a coupled system. In this study, we present a novel Fortran-Python interface designed to seamlessly integrate ML parameterizations into ESMs. This interface showcases high versatility by supporting popular ML frameworks like PyTorch, TensorFlow, and Scikit-learn. We demonstrate the interface's modularity and reusability through two cases: a ML trigger function for convection parameterization and a ML wildfire model. We conduct a comprehensive evaluation of memory usage and computational overhead resulting from the integration of Python codes into the Fortran ESMs. By leveraging this flexible interface, ML parameterizations can be effectively developed, tested, and integrated into ESMs.

54 ENVIRONMENTAL SCIENCES↗

Vasoactive neuroendocrine responses associated with tolerance to lower body negative pressure in humans

The purpose of this investigation was to test the hypothesis that peripheral vasoconstriction and orthostatic tolerance are associated with increased circulating plasma concentrations of noradrenaline, vasopressin and renin-angiotensin. Sixteen men were categorized as having high (HT, n=9) or low (LT, n=7) tolerance to lower body negative pressure (LBNP) based on whether the endpoint of their pre-syncopal-limited LBNP (peak LBNP) exposure exceeded -60 mmHg. The two groups were matched for age, height, weight, leg volume, blood volume and maximal oxygen uptake, as well as baseline blood volume and plasma concentrations of vasoactive hormones. Peak LBNP induced similar reductions in mean arterial pressure in both groups. The reduction in leg arterial pulse volume (measured by impedance rheography), an index of peripheral vascular constriction, from baseline to peak LBNP was greater (P<0.05) in the HT group (-0.041 +/- 0.005 ml 100 ml-1) compared to the reduction in the LT group (-0. 025 +/- 0.003 ml 100 ml-1). Greater peak LBNP in the HT group was associated with higher (P<0.05) average elevations in plasma concentrations of vasopressin (pVP, Delta=+7.2 +/- 2.0 pg ml-1) and plasma renin-angiotensin (PRA, Delta=+2.9 +/- 1.3 ng Ang II ml-1 h-1) compared to average elevations of pVP (+2.2 +/- 1.0 pg ml-1) and PRA (+0.1 +/- 0.1 ng Ang II ml-1 h-1) in the LT group. Plasma noradrenaline concentrations were increased (P<0.05) from baseline to peak LBNP in both HT and LT groups, with no statistically distinguishable difference between groups. These data suggest that the renin-angiotensin and vasopressin systems may contribute to sustaining arterial pressure and orthostatic tolerance by their vasoconstrictive actions.

NASA Discipline Cardiopulmonary↗

Lightning Instrumentation System

A new comprehensive lightning instrumentation system has been designed for the Mobile Launcher 1 (ML-1) at the Kennedy Space Center, Florida. This new instrumentation system includes the synchronized recording of three B-dot, 3-axis measurement stations, one D-dot sensor and eighteen vehicle measurement channels. Each vehicle measurement channel is comprised of two currents and one voltage measurements. The instrumentation system is composed of centralized transient recorders and digitizers, connected to the transient recorders via fiber optic cables. The transient recorders are triggered by the B-dot or D-dot sensors. When the Space Launch System (SLS) vehicle is present at the ML-1, the transient recorders record data on a dual sampling rate mode, continuous slow 5 kilo-samples per second (per channel) and event driven fast 100 mega-samples per second (per channel). Without the presence of the vehicle at the ML-1, the instrumentation system operates only as an event driven fast 100 mega-samples per second (per channel). In the absence of the vehicle, the only measurements recorded are the B-dot and D-dot stations. Additionally, a portable Lightning Monitoring System (LMS) is temporarily installed inside the Orion Crew Capsule module monitoring one portable B-dot, 3-axis measurement station, and 2 Crew Capsule BUS voltages. The portable LMS has a transient recorder independent of the ML-1 transient recorders, that is triggered by the portable B-dot sensor or transients on the vehicle BUS voltages. This portable instrumentation is removed while performing close out operations before the vehicle launch. For the ML-1 lightning instrumentation system, new custom B-dot and D-dot sensors were designed and prototypes were tested at the International Center for Lightning Research and Testing (ICLRT) at Camp Blanding, Florida. The Ground Special Power (GSP) vehicle measurement channels monitoring on the ML-1 is done via 1) Commercial off-the-shelf (COTS) current shunts and 2) custom Voltage Dividers. The new ML-1 lightning instrumentation system was designed, fabricated, deployed, and tested prior to the summer of 2019, in preparation for the first NASA's SLS mission to be launched from the Launch Complex 39B (LC-39B). The ML-1 lightning instrumentation was designed to complement the LC-39B lightning instrumentation system providing electromagnetic measurements closer to the vehicle, at different heights and inside the Crew capsule module.

Angel G Mata↗

A Quantitative Analysis on the Use of Supervised Machine Learning in Earth Science

Recent review papers (Ball et al., 2017; Reichstein et al., 2019) have investigated the opportunities and challenges in applying supervised machine learning (ML) techniques to Earth science problems. A common challenge is the lack of training (or labeled) data. Supervised ML, and especially deep learning (DL), require large training datasets. While there are large, open access Earth science archives, the data typically require preprocessing in preparation for supervised ML, frequently including manual labeling. Our objective is to understand the landscape of supervised ML in the Earth sciences, including which research communities have most rapidly adopted supervised ML, which algorithms are applied, and what data are used to train these algorithms. We conducted a literature survey of Earth science papers published during the last 10 years in journals from the American Geophysical Union (AGU), American Meteorological Society (AMS), the Institute of Electrical and Electronics Engineers(IEEE), and the Society of Photo-Optical Instrumentation Engineers (SPIE). We identified papers containing the terms ML, DL, or the names of individual supervised ML algorithms. "Earth science" is an additional required search term for IEEE and SPIE. We investigate trends in supervised ML usage during the 10-year study period, and manually analyzed AGU papers from 2018-2019 to enable deep-dive statistics.

Katrina S Virts↗

PAVE: An In Situ Framework for Scientific Visualization and Machine Learning Coupling

Machine learning (ML) has emerged as a tool for understanding data at scale. However, this new methodology comes at a cost because ML requires the use of even more HPC resources to generate ML algorithms. In addition to the compute resources required to develop ML algorithms, ML does not sidestep one of the biggest challenges on leading-edge HPC systems: the increasing gap between compute performance and I/O bandwidth. This has led to a strong push towards in situ, processing the data as it is generated, strategies to mitigate the I/O bottleneck. Unfortunately, there are no in situ frameworks dedicated to coupling scientific visualization and ML at scale to develop ML algorithms for scientific visualization. To address the ML and in situ visualization gap, we introduce PAVE. PAVE is an in situ framework which addresses the data management needs between visualisation and machine learning tasks. We demonstrate our framework with a case study that accelerates physically-based light rendering, path-tracing, through the use of a conditional Generative Adversarial neural Network (cGAN). PAVE couples the training over path-traced images resulting in a generative model able to produce scene renderings with accurate light transport and global illumination of a quality comparable to offline approaches in a more efficient manner.

Kim, Mark B.↗

FastML Science Benchmarks: Accelerating Real-Time Scientific Edge Machine Learning

Applications of machine learning (ML) are growing by the day for many unique and challenging scientific applications. However, a crucial challenge facing these applications is their need for ultra low-latency and on-detector ML capabilities. Given the slowdown in Moore's law and Dennard scaling, coupled with the rapid advances in scientific instrumentation that is resulting in growing data rates, there is a need for ultra-fast ML at the extreme edge. Fast ML at the edge is essential for reducing and filtering scientific data in real-time to accelerate science experimentation and enable more profound insights. To accelerate real-time scientific edge ML hardware and software solutions, we need well-constrained benchmark tasks with enough specifications to be generically applicable and accessible. These benchmarks can guide the design of future edge ML hardware for scientific applications capable of meeting the nanosecond and microsecond level latency requirements. To this end, we present an initial set of scientific ML benchmarks, covering a variety of ML and embedded system techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary report on applications of machine learning techniques to the Nevada play fairway analysis

We are applying machine learning (ML) techniques, including training set augmentation and artificial neural networks, to mitigate key challenges in the Nevada play fairway project. The study area includes ~85 active geothermal systems as potential training sites and >12 geologic, geophysical, and geochemical features. The main goal is to develop an algorithmic approach to identify new geothermal systems in the Great Basin region. Major objectives include: 1) integrate ML techniques into the geothermal community; 2) develop open community datasets, whereby all play fairway and ML datasets and algorithms are publicly released and available for modification by various user groups; 3) identify data acquisition targets with high value for future work; 4) identify new signatures to detect blind geothermal systems; and 5) foster new capabilities for characterizing subsurface temperature and permeability. Initially, ML techniques are being applied to the same play fairway datasets and workflow. ML will then be applied to both enhanced and additional datasets, with modification of the PFA workflow to incorporate the new datasets. Finally, ML will be applied to define new workflows using the enhanced and additional datasets. An algorithmic approach that empirically learns to estimate weights of influence for diverse parameters can potentially scale and perform better than the play fairway analysis. Initial work on this project has involved 1) evaluating potential positive and negative training sites, 2) transformation of datasets into formats suitable for ML, and 3) initial development and testing of ML techniques.

58 GEOSCIENCES↗

Explainability and extrapolation of machine learning models for predicting the glass transition temperature of polymers

Abstract Machine learning (ML) offers promising tools to develop surrogate models for polymers' structure–property relations. Surrogate models can be built upon existing polymer data and are useful for rapidly predicting the properties of unknown polymers. The accuracy of such ML models appears to depend on the feature space representation of polymers, the range of training data, and learning algorithms. Here, we establish connections between these factors for predicting the glass transition temperature (T g ) of polymers. Our analysis suggests linear models with fewer fitting parameters are as accurate as nonlinear models with many hidden and unexplainable parameters. Also, the performance of a monomer topology‐based ML model is found to be qualitatively identical to that of a physicochemical descriptor‐based ML model. We find that the ML models's performance in the extrapolative region is enhanced as the property range of the training data increases. Moreover, we establish newT g – polymer chemistry correlations via ML. Our work illustrates how ML can advance the fundamental understanding of polymer structure–property correlations and its efficacy for extrapolation problems.

Polymer Science↗

Screening green solvents for multilayer plastic film recycling processes

Multilayer (ML) plastic films are essential packaging materials that help protect products from diverse external factors; however, only 5% of all ML films are recycled in the United States. Solvent-based technologies are a promising alternative for recycling ML films because they enable recovery of constituent polymer resins. For example, the Solvent Targeted Recovery and Precipitation (STRAPTM) process sequentially dissolves and separates polymer components using a series of targeted solvent washes. A crucial design aspect of this process is the impact of selected solvents on human health and on the environment. Here, this work introduces a computational framework that integrates molecular modeling, process modeling, techno-economic analysis (TEA), and life-cycle analysis (LCA) to quickly screen green solvents for solvent-based ML recycling processes. Initial screening for solvents based on selectivity is performed by estimating temperature-dependent solubilities using molecular-scale models. Subsequent screening uses basic estimates of energy use and octanol-water partition coefficients (logP) as key measures of health, safety, and environmental hazards. Detailed process modeling, TEA, and LCA are used on a reduced set of promising solvents identified in early screening steps to more accurately determine how solvent selection and associated operating conditions impact overall economics and environmental impacts. The framework is used for the identification of green solvents (from a database of 1,000 solvents) that separate an industrial ML film composed of polyethylene (PE), ethylene vinyl alcohol (EVOH), and polyethylene terephthalate (PET). Our analysis shows the effectiveness of the framework and reveals fundamental trade-offs between solvent greenness, solubility, and economics. Our work emphasizes the importance of taking a holistic systems view during solvent design and aims to inform the development of new processes for ML film recycling and the identification of new ML films that are easier to recycle.

economics↗

Field-based AFDD for refrigerant undercharge in residential HVAC systems: enhancing reliability through false alarm mitigation

This study evaluated rule-based and machine learning (ML) based automated fault detection and diagnostics (AFDD) algorithms for detecting refrigerant undercharge faults in residential heating, ventilation, and air conditioning (HVAC) systems, using actual building data and a minimal set of features. The ML-based algorithms included Decision Tree (DT) and K-Nearest Neighbors (KNN). Both the rule-based and ML-based algorithms demonstrated the capability to detect refrigerant undercharge faults of -30% or more. Both types of algorithms exhibited false alarms before the implementation of a false alarm mitigation algorithm, which motivated the development of such a mitigation strategy. After applying the mitigation, false alarms were substantially reduced, with the rule-based algorithm decreasing to 0.6% and the ML-based algorithms reaching 0%, while maintaining strong detection performance. Although the rule-based algorithm initially showed lower performance compared to the ML-based algorithms, its detection accuracy improved after mitigation to a level comparable to the ML-based algorithms. These results confirm that combining false alarm mitigation with both rule-based and ML-based AFDD algorithms significantly enhances practical reliability while preserving robust fault detection capabilities. Furthermore, the findings demonstrate the potential for field deployment of these algorithms in residential HVAC systems and highlight the importance of minimizing false alarms.

False Alarm↗

Environmental exposure to industrial air pollution is associated with decreased male fertility

Objective: To understand how chronic exposure to industrial air pollution is associated with male fertility through semen parameters. Design: Retrospective cohort study. Subjects: Men in the Subfertility, Health and Assisted Reproduction cohort who underwent a semen analysis 2005-2017 with ≥1 measured semen parameter (N=21,563). Intervention(s): Residential histories for each man were constructed using locations from administrative records linked through the Utah Population Database. Industrial facilities with air emissions of nine endocrine disrupting compound chemical classes were identified from the Environmental Protection Agency Risk-Screening Environmental Indicators microdata. Chemical levels were linked with residential histories for the 5 years prior to each semen analysis. Main Outcome Measures: Semen analyses were classified as azoospermic or oligozoospermic (< 15 M/mL) using World Health Organization cutoffs for concentration. Bulk semen parameters such as concentration, total count, ejaculate volume, total motility, total motile count, and total progressive motile count were also measured. Multivariable regression models with robust standard errors were used to associate exposure quartiles for each of the nine chemical classes with each semen parameter, adjusting for age, race, and ethnicity, as well as neighborhood socioeconomic disadvantage. Results: After adjustment for demographic covariates, several chemical classes were associated with azoospermia and decreased total motility and volume. For exposure in the 4th relative to 1st quartile, significant associations were observed for acrylonitrile (β total motility = -0.87 pp), aromatic hydrocarbons (odds ratio [OR]azoospermia = 1.53; β volume = -0.14 mL), dioxins (OR azoospermia = 1.31; β volume = -0.09 mL; β total motility = -2.65 pp), heavy metals (β total motility = -2.78pp), organic solvents (OR azoospermia = 1.75; β volume = -0.10 mL), organochlorines (OR azoospermia = 2.09; β volume = -0.12 mL), phthalates (OR azoospermia = 1.44; β volume = -0.09 mL; β total motility = -1.21 pp), and silver particles (OR azoospermia = 1.64; β volume = -0.11 mL). All semen parameters significantly decreased with increasing socioeconomic disadvantage. Men who lived in the most disadvantaged areas had concentration, volume, and total motility of 6.70 M/mL, 0.13 mL, and 1.79 pp lower, respectively. Count, motile count, and total progressive motile count all decreased by 30–34 M.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

An investigation of a multi-layered oscillating heat pipe additively manufactured from Ti-6Al-4V powder

Here, a laser powder bed fusion (L-PBF) additive manufacturing (AM) method was employed for fabricating a multi-layered, Ti-6Al-4V oscillating heat pipe (ML-OHP). The 50.8 × 38.1 × 15.75 mm 3 ML-OHP consisted of four inter-connected layers of circular mini-channels, as well an integrated, hermetic-grade fill port. A series of experiments were conducted to characterize the ML-OHP thermal performance by varying power input (up to 50 W), working fluid (water, acetone, Novec™ 7200, and n-pentane), and operating orientation (vertical bottom-heating, horizontal, and vertical top-heating). The ML-OHP was found to operate effectively for all working fluids and orientations investigated, demonstrating that the OHP can function in a multi-layered form, and further indicating that one can ‘stack’ multiple, interconnected OHPs within flat media for increased thermal management. The ML-OHP evaporator size was found to depend on the layer-wise heat penetration which subsequently depends on power input and the ML-OHP design and material selection. Using neutron radiography, electron scanning microscopy and surface metrology, the ML-OHP channel structure was characterized and found to possess sintered Ti-6Al-4V powder along its periphery. The sintered channel surface, although a byproduct of the L-PBF manufacturing process, was found to behave as a secondary wicking structure for enhanced capillary pumping and wall/fluid heat transfer within the OHP. With the newfound capabilities of AM, many high heat flux thermal management devices, specifically those that employ mini- or micro-channels, can be ‘re-invented’ to possess embedded channels with atypical geometries, arrangements and surface conditions.

42 ENGINEERING↗

Dose Constraint for Minimizing Grade 2 Rectal Bleeding Following Brachytherapy Combined With External Beam Radiotherapy for Localized Prostate Cancer: Rectal Dose-Volume Histogram Analysis of 457 Patients

Purpose: To determine the rectal tolerance to Grade 2 rectal bleeding after I-125 seed brachytherapy combined with external beam radiotherapy (EBRT), based on the rectal dose-volume histogram. Methods and Materials: A total of 458 consecutive patients with stages T1 to T3 prostate cancer received combined modality treatment consisting of I-125 seed implantation followed by EBRT to the prostate and seminal vesicles. The prescribed doses of brachytherapy and EBRT were 100 Gy and 45 Gy in 25 fractions, respectively. The rectal dosimetric factors were analyzed for rectal volumes receiving >100 Gy and >150 Gy (R100 and R150) during brachytherapy and for rectal volumes receiving >30 Gy to 40 Gy (V30-V40) during EBRT therapy in 373 patients for whom datasets were available. The patients were followed from 21 to 72 months (median, 45 months) after the I-125 seed implantation. Results: Forty-four patients (9.7%) developed Grade 2 rectal bleeding. On multivariate analysis, age (p = 0.014), R100 (p = 0.002), and V30 (p = 0.001) were identified as risk factors for Grade 2 rectal bleeding. The rectal bleeding rate increased as the R100 increased: 5.0% (2/40 patients) for 0 ml; 7.5% (20/267 patients) for >0 to 0.5 ml; 11.0% (11/100 patients) for >0.5 to 1 ml; 17.9% (5/28 patients) for >1 to 1.5 ml; and 27.3% (6/22 patients) for >1.5 ml (p = 0.014). Grade 2 rectal bleeding developed in 6.4% (12/188) of patients with a V30 {<=}35% and in 14.1% (26/185) of patients with a V30 >35% (p = 0.02). When these dose-volume parameters were considered in combination, the Grade 2 rectal bleeding rate was 4.2% (5/120 patients) for a R100 {<=}0.5 ml and a V30 {<=}35%, whereas it was 22.4% (13/58 patients) for R100 of >0.5 ml and V30 of >35%. Conclusion: The risk of rectal bleeding was found to be significantly volume-dependent in patients with prostate cancer who received combined modality treatment. Rectal dose-volume analysis is a practical method for predicting the risk of development of Grade 2 rectal bleeding.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Normal Tissue Complication Probability Analysis of Acute Gastrointestinal Toxicity in Cervical Cancer Patients Undergoing Intensity Modulated Radiation Therapy and Concurrent Cisplatin

Purpose: To test the hypothesis that increased bowel radiation dose is associated with acute gastrointestinal (GI) toxicity in cervical cancer patients undergoing concurrent chemotherapy and intensity-modulated radiation therapy (IMRT), using a previously derived normal tissue complication probability (NTCP) model. Methods: Fifty patients with Stage I-III cervical cancer undergoing IMRT and concurrent weekly cisplatin were analyzed. Acute GI toxicity was graded using the Radiation Therapy Oncology Group scale, excluding upper GI events. A logistic model was used to test correlations between acute GI toxicity and bowel dosimetric parameters. The primary objective was to test the association between Grade {>=}2 GI toxicity and the volume of bowel receiving {>=}45 Gy (V{sub 45}) using the logistic model. Results: Twenty-three patients (46%) had Grade {>=}2 GI toxicity. The mean (SD) V{sub 45} was 143 mL (99). The mean V{sub 45} values for patients with and without Grade {>=}2 GI toxicity were 176 vs. 115 mL, respectively. Twenty patients (40%) had V{sub 45} >150 mL. The proportion of patients with Grade {>=}2 GI toxicity with and without V{sub 45} >150 mL was 65% vs. 33% (p = 0.03). Logistic model parameter estimates V50 and {gamma} were 161 mL (95% confidence interval [CI] 60-399) and 0.31 (95% CI 0.04-0.63), respectively. On multivariable logistic regression, increased V{sub 45} was associated with an increased odds of Grade {>=}2 GI toxicity (odds ratio 2.19 per 100 mL, 95% CI 1.04-4.63, p = 0.04). Conclusions: Our results support the hypothesis that increasing bowel V{sub 45} is correlated with increased GI toxicity in cervical cancer patients undergoing IMRT and concurrent cisplatin. Reducing bowel V{sub 45} could reduce the risk of Grade {>=}2 GI toxicity by approximately 50% per 100 mL of bowel spared.

62 RADIOLOGY AND NUCLEAR MEDICINE↗