Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MCNP6”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Methodology for Sensitivity and Uncertainty-Based Criticality Safety Validation

Monte Carlo radiation transport software is used extensively for determining the effective multiplication factor k of fissionable systems towards assessing the criticality safety of operations. Understanding the predictive capability of the Monte Carlo software and nuclear data libraries for calculations of specific applications is vital towards making these assessments. Recently, sensitivity and uncertainty (S/U) methods have been developed for this purpose. A computational tool has been developed that uses the S/U methods with MCNP6 to select critical experiment benchmarks that have similar sources of computational bias, and extreme value theory is then used to determine suitable and conservative calculational margins. The S/U techniques are then used to perform nuclear data adjustments, which are then used to determine a suitable margin of subcriticality from cross section uncertainties. This document gives an overview of the theory of S/U methods used for criticality safety validation. First an overview is given for using the sensitivity coefficients and nuclear co variance data towards determining neutronic similarity factors is then discussed. Next, the extreme value theory (EVT) to determine a calculational margin is given along with how the similarity factors are used in the analysis. Then, the Generalized Linear Least Squares (GLLS) method for performing data adjustment and how that method is used to reject benchmarks and compute adjusted nuclear data uncertainties in k are discussed. Last, a discussion of the margin of subcriticality is given along with how to apply of the GLLS data adjustment methods to quantify the effect of nuclear data variability on k.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Predicted Radiation Output from Several Kilograms of Plutonium Oxide

Neutron and gamma signatures from 3.44 kg of plutonium oxide were predicted with MCNP6 in anticipation of a passive diagnostic measurement campaign. Calculated radiation fields are visualized through use of “FMESH” type tallies. This work is effectively an extension of previous efforts and application of MISC for the photon source term is the main advancement. Large sources of modeling uncertainty include physical can dimensions and thus internal volume and density estimates. Material age is unknown and will also affect the passive gamma signature. The measurement campaign will provide information for model refinement and subsequent simulations. The authors have requested passive data collection on the pair of cans with the largest and smallest mass and such data will be valuable for benchmarking purposes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fast Neutron Spectrum Potassium Worth for Space Power Reactor Design Validation

A variety of critical experiments were constructed of enriched uranium metal (oralloy ) during the 1960s and 1970s at the Oak Ridge Critical Experiments Facility (ORCEF) in support of criticality safety operations at the Y-12 Plant. The purposes of these experiments included the evaluation of storage, casting, and handling limits for the Y-12 Plant and providing data for verification of calculation methods and cross-sections for nuclear criticality safety applications. These included solid cylinders of various diameters, annuli of various inner and outer diameters, two and three interacting cylinders of various diameters, and graphite and polyethylene reflected cylinders and annuli. Of the hundreds of delayed critical experiments, one was performed that consisted of uranium metal annuli surrounding a potassium-filled, stainless steel can. The outer diameter of the annuli was approximately 13 inches (33.02 cm) with an inner diameter of 7 inches (17.78 cm). The diameter of the stainless steel can was 7 inches (17.78 cm). The critical height of the configurations was approximately 5.6 inches (14.224 cm). The uranium annulus consisted of multiple stacked rings, each with radial thicknesses of 1 inch (2.54 cm) and varying heights. A companion measurement was performed using empty stainless steel cans; the primary purpose of these experiments was to test the fast neutron cross sections of potassium as it was a candidate for coolant in some early space power reactor designs.The experimental measurements were performed on July 11, 1963, by J. T. Mihalczo and M. S. Wyatt with additional information in its corresponding logbook. Unreflected and unmoderated experiments with the same set of highly enriched uranium metal parts were performed at the Oak Ridge Critical Experiments Facility in the 1960s and are evaluated in the International Handbook for Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook) with the identifier HEU MET FAST 051. Thin graphite reflected (2 inches or less) experiments also using the same set of highly enriched uranium metal parts are evaluated in HEU MET FAST 071. Polyethylene-reflected configurations are evaluated in HEU-MET-FAST-076. A stack of highly enriched metal discs with a thick beryllium top reflector is evaluated in HEU-MET-FAST-069, and two additional highly enriched uranium annuli with beryllium cores are evaluated in HEU-MET-FAST-059. Both detailed and simplified model specifications are provided in this evaluation. Both of these fast neutron spectra assemblies were determined to be acceptable benchmark experiments. The calculated eigenvalues for both the detailed and the simple benchmark models are within ~0.26 % of the benchmark values for Configuration 1 (calculations performed using MCNP6 with ENDF/B-VII.1 neutron cross section data), but under-calculate the benchmark values by ~7s because the uncertainty in the benchmark is very small: ~0.0004 (1s); for Configuration 2, the under-calculation is ~0.31 % and ~8s. Comparison of detailed and simple model calculations for the potassium worth measurement and potassium mass coefficient yield results approximately 70 – 80 % lower (~6s to 10s) than the benchmark values for the various nuclear data libraries utilized. Both the potassium worth and mass coefficient are also deemed to be acceptable benchmark experiment measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

GENXS Expansion to Include Fragment Spectra of Heavy Ions

The GENXS Card allows for various cross sections to be tallied in MCNP6 (see LA-UR-11-02146 by Richard Prael). Previously, double differential cross sections (cross section per emitted fragment energy and angle) were only available for fragments up to 4 He. This upgrade includes the ability to tally and output double differential cross sections for any heavy ion (with valid ZAID). It also includes the ability to tally and output angle-integrated cross sections per emitted fragment energy for any ZAID.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Reference Benchmark Field Specifications: ACRR Polyethylene-Lead-Graphite (PLG) Bucket Environment (ACRR-PLG-CC-32-CL)

This report was put together to support the International Atomic Energy Agency (IAEA) REAL- 2016 activity to validate the dosimetry community’s ability to use a consistent set of activation data and to derive consistent spectral characterizations. The report captures details of integral measurements taken in the Annular Core Research Reactor (ACRR) central cavity with the Polyethylene-Lead-Graphite (PLG) bucket, reference neutron benchmark field. The field is described and an “a priori” calculated neutron spectrum is reported, based on MCNP6 calculations, and a subject matter expert (SME) based covariance matrix is given for this “a priori” spectrum. The results of 37 integral dosimetry measurements in the neutron field are reported.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Neutron Reference Benchmark Field Specification: ACRR 44 Inch Lead-Boron (LB44) Bucket Environment (ACRR-LB44-CC-32-CL)

This report was put together to support the International Atomic Energy Agency (IAEA) REAL- 2016 activity to validate the dosimetry community’s ability to use a consistent set of activation data and to derive consistent spectral characterizations. The report captures details of integral measurements taken in the Annular Core Research Reactor (ACRR) central cavity with the 44 inch Lead-Boron (LB44) bucket, reference neutron benchmark field. The field is described and an “a priori” calculated neutron spectrum is reported, based on MCNP6 calculations, and a subject matter expert (SME) based covariance matrix is given for this “a priori” spectrum. The results of 31 integral dosimetry measurements in the neutron field are reported.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Neutron Reference Benchmark Field Specification: ACRR Free-Field Environment (ACRR-FF-CC-32-CL)

This report was put together to support the International Atomic Energy Agency (IAEA) REAL- 2016 activity to validate the dosimetry community’s ability to use a consistent set of activation data and to derive consistent spectral characterizations. The report captures details of integral measurements taken in the Annular Core Research Reactor (ACRR) central cavity free-field reference neutron benchmark field. The field is described and an “a priori” calculated neutron spectrum is reported, based on MCNP6 calculations, and a subject matter expert (SME) based covariance matrix is given for this “a priori” spectrum. The results of 31 integral dosimetry measurements in the neutron field are reported.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Model development and data uncertainty integration

The effect of data uncertainties is discussed, with the epithermal neutron multiplicity counter as an illustrative example. Simulation using MCNP6, cross section perturbations and correlations are addressed, along with the effect of the 240 Pu spontaneous fission neutron spectrum, the effect of P(ν) for 240 Pu spontaneous fission, and the effect of spontaneous fission and (α,n) intensity. The effect of nuclear data is the product of the initial uncertainty and the sensitivity -- both need to be estimated. In conclusion, a multi-parameter variation method has been demonstrated, the most significant parameters are the basic emission rates of spontaneous fission and (α,n) processes, and uncertainties and important data depend on the analysis technique chosen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel Deployment of Elpasolites as a Dual Neutron/Gamma-Ray Directional Detector

At a time when upholding national security has never been more important, there exists a need for the advancement of radiation detection technologies. Neutron and photon detectors are essential to fulfilling mission areas including detection and localization of missing, stolen or smuggled radiological or nuclear materials, quantification of the effects of a radiological or nuclear event, and supporting nonproliferation efforts. The aim of this study was to evaluate a new radiation detector based on the scintillation elpasolite compound Cs 2 LiYCl 6 :Ce (CLYC) for simultaneous measurements of neutron and photon flux and the localization of radiation sources. Previous studies performed on the CLYC scintillator indicate its potential for thermal neutron and gamma-ray measurements. This study is dedicated to the novel application of the CLYC as a dual neutron / photon detector and as part of a directional detection system. Both computational modeling and an experimental study were carried out within this research project. As part of the computational study, the response of a CLYC scintillator detector to gamma rays induced by thermal neutron interaction with Cl and 7 Li nuclei was investigated using the MCNP6 code. In addition, arrays of three and four CLYC detectors were modeled in order to evaluate the directional detection of both a thermal neutron source and a gamma-ray source. It was shown that little or no quality of source direction determination would be lost when three detectors were used in the array compared to four detectors. In the experimental study, the photon spectroscopy capabilities of the CLYC detectors were evaluated. A gamma-ray energy resolution of 4.9% was measured for the 662-keV peak of 137 Cs and 3.6% for the 1.33-MeV peak of 60 Co. Using a thermal neutron source, the pulse shape discrimination analysis was successfully performed for the CLYC detector signal waveforms. Thermal neutrons and gamma rays were separated with an exceptional figure of merit (FOM) of 2.3. An array of three CLYC detectors was assembled for the purpose of directional neutron / gamma-ray detection. The intrinsic peak efficiency of CLYC detectors was evaluated. The three-CLYC detector array was deployed for directional measurements with a single gamma-ray 137 Cs source, two gamma-ray sources of 137 Cs and 60 Co isotopes and a thermal neutron source designed using a 239PuBe neutron source supplied with a polyethylene moderator. Measurements were carried out using sources located in the longitude and latitude planes over the angles from 0° to 360°. The measured data were processed through a maximum likelihood estimation algorithm providing a possible direction for which the radioactive source in each case was positioned. The estimated directions were close if not exact matches for the actual directions to the radioactive source. The largest discrepancy in direction produced by the algorithm was approximately 11%. However, it was hypothesized that this percent error can be decreased by homogenizing the directional detection system to consist of scintillators of the same size and quality, identical photomultiplier tubes and identical aluminum housings. The feasibility of this hypothesis to decrease the percent error was confirmed by the zero percent error achieved in the directional measurements produced in the computational study utilizing a homogenous directional detection system. The results of computational and experimental studies completed within this research project provide means to propose the array of three CLYC scintillators as an efficient dual neutron / gamma-ray directional detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analytic computation of average energy of neutrons inducing fission

The objective of this report is to describe how I analytically computed the average energy of neutrons that induce fission in the bare BeRP ball. The motivation of this report is to resolve a discrepancy between the average energy computed via the FMULT and F4/FM cards in MCNP6 by comparison to the analytic results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Covariance Data File Formats for Whisper-1.0 & Whisper-1.1

Whisper is a statistical analysis package developed in 2014 to support nuclear criticality safety (NCS) validation. It uses the sensitivity profile data for an application as computed by MCNP6 along with covariance files for the nuclear data to determine a baseline upper-subcritical-limit (USL) for the application. Whisper version 1.0 was first developed and used at LANL in 2014. During 2015-2016, Whisper was updated to version 1.1 and is to be included with the upcoming release of MCNP6.2. This report describes the file formats used for the covariance data in both Whisper-1.0 and Whisper-1.1.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

User Manual for Whisper-1.1

Whisper is a statistical analysis package developed in 2014 to support nuclear criticality safety (NCS) validation [1-3]. It uses the sensitivity profile data for an application as computed by MCNP6 [4-6] along with covariance files [7,8] for the nuclear data to determine a baseline upper-subcritical-limit (USL) for the application. Whisper version 1.0 was first developed and used at LANL in 2014 [3]. During 2015- 2016, Whisper was updated to version 1.1 and is to be included with the upcoming release of MCNP6.2. This document describes the user input and options for running whisper-1.1, including 2 perl utility scripts that simplify ordinary NCS work, whisper_mcnp.pl and whisper_usl.pl. For many detailed references on the theory, applications, nuclear data & covariances, SQA, verification-validation, adjointbased methods for sensitivity-uncertainty analysis, and more – see the Whisper – NCS Validation section of the MCNP Reference Collection at mcnp.lanl.gov. There are currently over 50 Whisper reference documents available.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Listing of Available ACE Data Tables

This document is divided into multiple sections. Section 2 lists some of the more frequently used ENDF/B reaction types that can be used with the FM input card. The remaining sections (described below) contain tables showing the available ACE data tables for various types of data. These ACE data libraries are distributed by the Radiation Safety Information Computational Center (RSICC) with MCNP6.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Release Notes for Whisper-1.1

Whisper is a statistical analysis package developed in 2014 to support nuclear criticality safety (NCS) validation [1-3]. It uses the sensitivity profile data for an application as computed by MCNP6 [4-6] along with covariance files [7,8] for the nuclear data to determine a baseline upper-subcritical-limit (USL) for the application. Whisper version 1.0 was first developed and used at LANL in 2014 [3]. During 2015-2016, Whisper was updated to version 1.1 [9] and is to be included with the upcoming release of MCNP6.2. This document describes the Whisper-1.1 package that will be included with the MCNP6.2 release during 2017. Specific details are provided on the computer systems supported, the software quality assurance (SQA) procedures, installation, and testing. This document does not address other important topics, such as the importance of sensitivity-uncertainty (SU) methods to NCS validation, the theory underlying SU methodology, tutorials on the usage of MCNP-Whisper, practical approaches to using SU methodology to support and extend traditional validation, etc. There are over 50 documents included with Whisper-1.1 and available in the MCNP Reference Collection on the MCNP website (mcnp.lanl.gov) that address all of those topics and more. In this document, however, a complete bibliography of relevant MCNP-Whisper references is provided.

97 MATHEMATICS AND COMPUTING↗

Duplicating MC-15 Output with Python and MCNP

Two Python scripts have been written that process the output files of MCNP6 into a format that mimics the list-mode output of Los Alamos National Laboratory’s MC-15 and NPOD neutron detection systems. This report details the methods implemented in these scripts and instructions on their use.

97 MATHEMATICS AND COMPUTING↗

How to Build MCNP 6.2

This presentation describes how to build MCNP 6.2. MCNP®* 6.2 can be compiled on Macs, PCs, and most Linux systems. It can also be built for parallel execution using both OpenMP and Messing Passing Interface (MPI) methods. MCNP6 requires Fortran, C, and C++ compilers to build the code.

97 MATHEMATICS AND COMPUTING↗

Calculational Model of the Radiation Calibration Lab (RCL) and the Neutron Measurements performed at the Facility, with a 252 Cf Source

Calibration of detectors measuring gamma, neutron, alpha and beta radiation, and of personal dosimeters used at Lawrence Livermore National Laboratory (LLNL), is performed at the Radiation Calibration Lab (RCL). The calibrations done with a standard calibrated 252 Cf source are a function of the energy spectra, fluence and dose of the source. A detailed calculational model of the RCL has been carried out with the MCNP6 code. The calculations have also reproduced quite well the measurements of the fluence and dose rates for the bare and moderated 252 Cf source carried out by R. Radev using the Rospec Spectrometer and by Clark and Wilson using a Passive Neutron Spectrometer. The importance of having the calculational model of the RCL facility is to calculate the dose rates expected for a given planned measurement, optimizing the choice of detectors, design and shielding materials before the actual measurement are carried out, resulting in a more efficient and time saving measurement. Furthermore, an accurate model of the facility allows to detect possible problems with the measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗