Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Hybrid Glacier Inventory, Gravimetry and Altimetry (HIGA) Mass Balance Product for Greenland and the Canadian Arctic

We present a novel inversion algorithm that generates a mass balance field that is simultaneously consistent with independent observations of glacier inventory derived from optical imagery, cryosphere-attributed mass trends derived from satellite gravimetry, and ice surface elevation trends derived from airborne and satellite altimetry. We use this algorithm to assess mass balance across Greenland and the Canadian Arctic over the Sep-2003 to Oct- 2009 period at 26 kilometers resolution. We evaluate local algorithm-inferred mass balance against forty in situ point observations. This evaluation yields a root mean squared error (RMSE) of 0.15 mWE/a ( 0.15 meters (water equivalent) per annum), and highlights a paucity of in situ observations from regions of high dynamic mass loss and peripheral glaciers. We assess mass losses of 212 plus or minus 67 Gigatons per annum to the Greenland ice sheet proper, 38 Gigatons per annum to peripheral glaciers in Greenland, and 42 Gigatons per annum to glaciers in the Canadian Arctic. These magnitudes of mass loss are dependent on the gravimetry-derived spherical harmonic mass trend we invert. We spatially partition the transient glacier continuity equation by differencing algorithm inferred mass balance from modeled surface mass balance, in order to solve the horizontal divergence of ice flux as a residual. This residual ice dynamic field infers flux divergence (or submergent flow) in the ice sheet accumulation area and at tidewater margins, and flux convergence (or emergent flow) in land-terminating ablation areas, which is consistent with continuum mechanics theory.

Altimetry↗

A computer controlled mass spectrometer system for investigating the decomposition of non-metallic materials under atmospheric conditions

A PDP 11/23 quadrupole mass spectrometer system was coupled to a nondiscriminating gas inlet system permitting gases at atmospheric pressure to be admitted into a high vacuum chamber containing the ion source of the mass spectrometer without separation of the gaseous components. The resolution of related software problems has resulted in a convenient computer-mass spectrometer system capable of generating masses, relative intensities and related data on the gaseous products resulting from the atmospheric thermal decomposition of nonmetallic materials.

Thompson, J. M.↗

Lunar mass spectrometer test program

The procedures are described along with results obtained in a test program conducted to demonstrate the performance of a candidate lunar mass spectrometer. The instrument was designed to sample and measure gases believed to exist in the lunar atmosphere at the surface. The subject instrument consists of a cold cathode ion source, a small quadrupole mass analyzer and an off axis electron multiplier ion counting detector. The major program emphasis was placed on demonstrating instrument resolution, sensitivity and S/N ratio over the mass range 0-150 amu and over a partial pressure range from 10 to the minus 9th power to 10 to the minus 13th power torr. Ultrahigh vacuum tests were conducted and the minimum detectable partial pressure for neon, argon, krypton and xenon was successfully determined for the spectrometer using isotopes of these gases. With the exception of neon, the minimum detectable partial pressure is approximately 4 x 10 to the minus 14th power torr for the above gases.

Torney, F. L.↗

Pioneer Venus large probe neutral mass spectrometer

The Pioneer Venus large probe neutral mass spectrometer (LNMS) uses a single focusing magnetic sector field mass analyzer with mass range of 1-208 amu, resolution sufficient to separate the mercury isotopes, and sensitivity sufficient to detect minor constituents in the 1 ppm range relative to the CO2 in the Venus atmosphere. A combination of ion and chemical pumping is used to maintain a vacuum in the mass analyzer and to remove the atmosphere gases which enter the ion source chamber through a special leak. A microprocessor controls the operation of the instrument through a highly efficient peak stepping and data compression program, permitting acquisition of a complete mass spectrum roughly once each minute.

Hoffman, J. H.↗

A survey of mass-loss effects in early-type stars

Intermediate-resolution data obtained with the Copernicus satellite are surveyed in order to define the region in the H-R diagram where mass loss occurs. The survey includes 40 stars, providing good coverage of supergiants from O4 to A2 and main-sequence stars from O4 to B7 as well as spotty coverage of late O giants and intermediate to late B stars. The spectral transitions examined are primarily resonance lines of ions of abundant elements plus some lines arising from excited states (e.g., C III at 1175.7 A and Si IV at 1122.5 A). Observed P Cygni profiles are discussed along with interesting features of some individual profiles. The data are shown to indicate that mass-loss effects occur over a wide portion of the H-R diagram, that mass ejection generally occurs when the holometric magnitude is greater than -6.0, and that the mass-ejection rate is usually high enough to produce P Cygni profile whenever the N V feature at 1240 A is present in a spectrum.

Snow, T. P., Jr.↗

Lunar observer laser altimeter

Understanding the global topography of the Moon is especially important for answering questions concerning lunar origin and evolution. Many outstanding problems in lunar science can be addressed with high resolution topographic data. The severe power, mass, size, and data-rate limitations imposed by the Lunar Geoscience Observer (LGO) and other Observer-class missions are major challenges for all instruments capable of measuring topography. A radar altimeter that meets these strict requirements could obtain a global prespective of lunar topography with a few kilometers spatial resolution and 10 m vertical resolution from a lunar orbit of 100 km. A prototype model is being constructed of the Lunar Observer Laser Altimeter (LOLA) capable of continuously measuring the range to the lunar surface with sub-meter vertical resolution within a 30 to 300 m diameter surface footprint. This same instrument is also designed to provide a direct measure of the surface height distribution in the footprint by waveform analysis of the backscattered laser pulse. Both these measurements are to be made in a continuous, nadir profile across the lunar surface from a 100 km orbit. The wavelength of the altimeter is 1064 nm. A short-pulse (2 nsec), diode-pumped Nd:YAG laser combined with a 25 cm diameter telescope, silicon avalanche photodiode detector, ranging electronics, and instrument computer was designed to make these measurements and meet all the requirements of the LGO mission.

Bufton, J. L.↗

Next Generation X-Ray Optics: High-Resolution, Light-Weight, and Low-Cost

X-ray telescopes are essential to the future of x-ray astronomy. This paper describes a comprehensive program to advance the technology for x-ray telescopes well beyond the state of the art represented by the three currently operating missions: Chandra, XMM-Newton , and Suzaku . This program will address the three key issues in making an x-ray telescope: (I) angular resolution, (2) effective area per unit mass, and (3) cost per unit effective area. The objectives of this technology program are (1) in the near term, to enable Explorer-class x-ray missions and an IXO type mission, and (2) in the long term, to enable a flagship x-ray mission with sub-arcsecond angular resolution and multi-square-meter effective area, at an affordable cost. We pursue two approaches concurrently, emphasizing the first approach in the near term (2-5 years) and the second in the long term (4-10 years). The first approach is precision slumping of borosilicate glass sheets. By design and choice at the outset, this technique makes lightweight and low-cost mirrors. The development program will continue to improve angular resolution, to enable the production of 5-arcsecond x-ray telescopes, to support Explorer-class missions and one or more missions to supersede the original IXO mission. The second approach is precision polishing and light-weighting of single-crystal silicon mirrors. This approach benefits from two recent commercial developments: (1) the inexpensive and abundant availability of large blocks of mono crystalline silicon, and (2) revolutionary advances in deterministic, precision polishing of mirrors. By design and choice at the outset, this technique is capable of producing lightweight mirrors with sub-arcsecond angular resolution. The development program will increase the efficiency and reduce the cost of the polishing and the lightweighting processes, to enable the production of lightweight sub-arcsecond x-ray telescopes. Concurrent with the fabrication of lightweight mirror segments is the continued development and perfection of alignment and integration techniques, for incorporating individual mirror segments into a precision mirror assembly. Recently, we have been developing a technique called edge-bonding, which has achieved an accuracy to enable 10- arcsecond x-ray telescopes. Currently, we are investigating and improving the long-term alignment stability of so-bonded mirrors. Next, we shall refine this process to enable 5-arsecond x-ray telescopes. This technology development program includes all elements to demonstrate progress toward TRL-6: metrology; x-ray performance tests; coupled structural, thermal, and optical performance analysis, and environmental testing.

Zhang, William W.↗

Next Generation X-Ray Optics: High-Resolution, Light-Weight, and Low-Cost

X-ray telescopes are essential to the future of x-ray astronomy. In this talk I will describe a comprehensive program to advance the technology for x-ray telescopes well beyond the state of the art represented by the three currently operating missions: Chandra, XMM-Newton, and Suzaku. This program will address the three key issues in making an x-ray telescope: (1) angular resolution, (2) effective area per unit mass, and (3) cost per unit effective area. The objectives of this technology program are (1) in the near term, to enable Explorer-class x-ray missions and an IXO-type mission, and (2) in the long term, to enable a flagship x-ray mission with sub-arcsecond angular resolution and multi-square-meter effective area, at an affordable cost. We pursue two approaches concurrently, emphasizing the first approach in the near term (2-5 years) and the second in the long term (4-10 years). The first approach is precision slumping of borosilicate glass sheets. By design and choice at the outset, this technique makes lightweight and low-cost mirrors. The development program will continue to improve angular resolution, to enable the production of 5-arcsecond x-ray telescopes, to support Explorer-class missions and one or more missions to supersede the original IXO mission. The second approach is precision polishing and light-weighting of single-crystal silicon mirrors. This approach benefits from two recent commercial developments: (1) the inexpensive and abundant availability of large blocks of monocrystalline silicon, and (2) revolutionary advances in deterministic, precision polishing of mirrors. By design and choice at the outset, this technique is capable of producing lightweight mirrors with sub-arcsecond angular resolution. The development program will increase the efficiency and reduce the cost of the polishing and the light-weighting processes, to enable the production of lightweight sub-arcsecond x-ray telescopes. Concurrent with the fabrication of lightweight mirror segments is the continued development and perfection of alignment and integration techniques, for incorporating individual mirror segments into a precision mirror assembly. Recently, we have been developing a technique called edge-bonding, which has achieved an accuracy to enable 10-arcsecond x-ray telescopes. Currently, we are investigating and improving the long-term alignment stability of so-bonded mirrors. Next, we shall refine this process to enable 5-arsecond x-ray telescopes. This technology development program includes all elements to demonstrate progress toward TRL-6: metrology; x-ray performance tests; coupled structural, thermal, and optical performance analysis, and environmental testing.

Zhang, William W.↗

Mass density and pressure changes across the dayside magnetopause

Plasma composition measurements at about 2-min time resolution from 27 magnetopause crossings are used to determine if mass density rho, modified by the anisotropic pressure term (1-alpha), is constant across the magnetopause. Pressure and mass density in the magnetosheath and low-latitude boundary layer were found to be dominated by H(+) except on one occasion when O(+) was the dominant contributor to the total mass density in the low-latitude boundary layer. Using these measurements, it is found that rho(1-alpha) is not constant for almost all magnetopause crossings even when there is independent evidence for magnetic reconnection and an open magnetopause. These results indicate that the reason why rho(1-alpha) is not constant across the magnetopause is that the H(+) density decrease from the magnetosheath to the low-latitude boundary layer is not compensated for by either a change in the pressure anisotropy or a change in the total mass density and suggest that the magnetopause can never be described as a time-stationary 1D rotational discontinuity.

Fuselier, S. A.↗

Mass loss in M67 giants - Evidence from isochrone fitting

A comparison between the color-magnitude diagram of M67 and a new set of theoretical evolutionary models which include all phases from the unevolved main-sequence through core-helium burning and onto the AGB is presented. The present 5-Gyr solar abundance isochrone is found to yield an excellent fit to the whole of the M67 color-magnitude diagram. A differential technique that compares the gap in color between clump giants and normal red giants, on one hand, with the temperature gap between core He-burning tracks and first-ascent RGB tracks, on the other, strongly indicates that the clump giants in M67 have masses of 0.70 solar mass or less. The extremely large amount of mass loss that is deduced is well in excess of that found for globular cluster stars. Possible resolutions of this problem are that degree of mass loss increases with total stellar mass, or with metallicity.

Tripicco, Michael J.↗

Quantitative comparison of combined gas chromatographic/mass spectrometric profiles of complex mixtures

The paper describes a method called HISLIB for automatic quantitative comparison of gas chromatographic/mass spectrometric (GC/MS) results obtained on complex mixtures of organic compounds. The method is based on comparing new mixtures to 'historical' libraries of previous results. Co-occurrence of components is determined by matching relative retention indices (RRIs) and mass spectra after background removal and resolution of overlapping GC components. Internal standards are used to quantify the relative concentrations of components. Applications of HISLIB include validation of analytical procedures to isolate complex mixtures; development of historical libraries which might include complete summaries of all past observations, compilations of controls, or any other selected subset of results; improvement of the quality of existing libraries of mass spectral data; and detection of differences in kind and/or amounts of individual components. Limitations of the method are mentioned along with causes of their occurrence.

Smith, D. H.↗

Lunar mass spectrometer test program

The procedures used and the results are described, which were obtained in a test program to demonstrate the performance of a candidate lunar mass spectrometer. The instrument was designed to sample and measure gases believed to exist in the lunar atmosphere at the surface. The instrument consists of a cold cathode ion source, a small quadrupole mass analyzer, and an off-axis electron multiplier ion-counting detector. Instrument resolution, sensitivity, and S/N ratio were demonstrated over the mass range 0-150 amu and over a partial pressure range from ntorr to ptorr. The subject analyzer was also prepared for extended testing, in conjunction with two other candidate instruments, in a large molecular beam vacuum facility.

Torney, F. L.↗

High resolution measurements of nightside ion troughs at Venus - Evidence of electrodynamic perturbations

The Bennett rf ion mass spectrometer of the Pioneer Venus Orbiter was expressly designed to provide variable temporal resolution for measurements of thermal ion composition and density. The Explore-Adapt mode is used to obtain priority for measuring the most prominent ion species; in the 2/16 configuration, the two dominant ions within the available range of 16 species are selectively sampled at the highest rate of 0.2 sec/sample. The high-resolution measurements are combined with independent observations from the magnetic field, neutral mass spectrometer, and electron temperature experiments in investigating sharply structured troughs in the low-altitude nightside ion concentrations. The results suggest a close correlation between the structure in the ion distributions and the structured configuration of the magnetic field that is draped about the planet. In the regions of the ion depletions, sharp fluctuations in electron temperature and anomalous increases in the density of neutral gases suggest that the ion depletion may be associated with dynamic perturbation in the ion and neutral flows and/or local joule heating.

Taylor, H. A., Jr.↗

MOS Circuitry Would Detect Low-Energy Charged Particles

Metal oxide semiconductor (MOS) circuits for measuring spatially varying intensities of beams of low-energy charged particles have been developed. These circuits are intended especially for use in measuring fluxes of ions with spatial resolution along the focal planes of mass spectrometers. Unlike prior mass spectrometer focal-plane detectors, these MOS circuits would not be based on ion-induced generation of electrons, and photons; instead, they would be based on direct detection of the electric charges of the ions. Hence, there would be no need for microchannel plates (for ion-to-electron conversion), phosphors (for electron-to-photon conversion), and photodetectors (for final detection) -- components that degrade spatial resolution and contribute to complexity and size. The developmental circuits are based on linear arrays of charge-coupled devices (CCDs) with associated readout circuitry (see figure). They resemble linear CCD photodetector arrays, except that instead of a photodetector, each pixel contains a capacitive charge sensor. The capacitor in each sensor comprises two electrodes (typically made of aluminum) separated by a layer of insulating material. The exposed electrode captures ions and accumulates their electric charges during signal-integration periods.

Sinha, Mahadeva↗

A Sensitive Quantitative Analysis of Abiotically Synthesized Short Homopeptides using Ultraperformance Liquid Chromatography and Time-of-Flight Mass Spectrometry

In the origins of life field understanding the abiotic polymerization of simple organic monomers (e.g., amino acids) into larger biomolecules (e.g., oligopeptides), remains a seminal challenge. Recently, preliminary observations showed a limited set of peptides formed in the presence of the plausible prebiotic phosphorylating agent, diamidophosphate (DAP), highlighting the need for an analytical tool to critically evaluate the ability of DAP to induce oligomerization of simple organics under aqueous conditions. However, performing accurate and precise, targeted analyses of short oligopeptides remains a distinct challenge in the analytical chemistry field. Here, we developed a new technique to detect and quantitate amino acids and their homopeptides in a single run using ultraperformance liquid chromatography-fluorescence detection/time of flight mass spectrometry. Over an 8-minute retention time window, 18 target analytes were identified and quantitated, 16 of which were chromatographically separated at, or near baseline resolution. Compound identity was confirmed by accurate mass analysis using a 10 ppm mass tolerance window. This method featured limits of detection < 5 nM (< 1 fmol on column) and limits of quantitation (LOQs) <15 nM (< 3 fmol on column). The LODs and LOQs were upwards of ∼28x and ∼788x lower, respectively, than previous methods for the same analytes, highlighting the quantifiable advantages of this new method. Both detectors provided good quantitative linearity (R(exp 2) > 0.985) for all analytes spanning concentration ranges ∼3 - 4 orders of magnitude. We performed a series of laboratory experiments to investigate DAP-mediated oligomerization of amino acids and peptides and analyzed experimental products with the new method. DAP readily polymerized amino acids and peptides under a range of simulated environmental conditions. This research underscores the potential of DAP to have generated oligopeptides on the primordial Earth, enhancing prebiotic chemical diversity and complexity at or near the origin of life.

Prebiotic Chemistry and Analytical Chemistry↗

A miniature high-resolution accelerometer utilizing electron tunneling

New methods have been developed to implement high-resolution position sensors based on electron tunneling. These methods allow miniaturization while utilizing the position sensitivity of electron tunneling to give high resolution. A single-element tunneling accelerometer giving a displacement resolution of 0.002 A/sq rt Hz at 10 Hz, corresponding to an acceleration resolution of 5 x 10 exp -8 g/sq rt Hz, is described. A new dual-element tunneling structure which overcomes the narrow bandwidth limitations of a single-element structure is described. A sensor with an operating range of 5 Hz to 10 kHz, which can have applications as an acoustic sensor, is discussed. Noise is analyzed for fundamental thermal vibration of the suspended masses and is compared to electronic noise. It is shown that miniature tunnel accelerometers can achieve resolution such that thermal noise in the suspended masses is the dominant cause of the resolution limit. With a proof mass of order 100 mg, noise analysis predicts limiting resolutions approaching 10 exp -9 g/sq rt Hz in a 300 Hz band and 10 exp -8 g/sq rt Hz at 1 kHz.

Rockstad, Howard K.↗

MISTiC Winds, a Micro-Satellite Constellation Approach to High Resolution Observations of the Atmosphere Using Infrared Sounding and 3D Winds Measurements

MISTiC(TM) Winds is an approach to improve short-term weather forecasting based on a miniature high resolution, wide field, thermal emission spectrometry instrument that will provide global tropospheric vertical profiles of atmospheric temperature and humidity at high (3-4 km) horizontal and vertical ( 1 km) spatial resolution. MISTiCs extraordinarily small size, payload mass of less than 15 kg, and minimal cooling requirements can be accommodated aboard a 27U-class CubeSat or an ESPA-Class micro-satellite. Low fabrication and launch costs enable a LEO sunsynchronous sounding constellation that would collectively provide frequent IR vertical profiles and vertically resolved atmospheric motion vector wind observations in the troposphere. These observations are highly complementary to present and emerging environmental observing systems, and would provide a combination of high vertical and horizontal resolution not provided by any other environmental observing system currently in operation. The spectral measurements that would be provided by MISTiC Winds are similar to those of NASA's AIRS that was built by BAE Systems and operates aboard the AQUA satellite. These new observations, when assimilated into high resolution numerical weather models, would revolutionize short-term and severe weather forecasting, save lives, and support key economic decisions in the energy, air transport, and agriculture arenasat much lower cost than providing these observations from geostationary orbit. In addition, this observation capability would be a critical tool for the study of transport processes for water vapor, clouds, pollution, and aerosols. Key remaining technical risks are being reduced through laboratory and airborne testing under NASA's Instrument Incubator Program.

Maschhoff, K. R.↗

Time-Varying Ice Sheet Mask: Implications on Ice-Sheet Mass Balance and Crustal Uplift

Mass-balance estimates of the polar ice sheets presently rely on static ice masks to identify the area under investigation. However, the vintage of available ice masks can differ by more than a decade and the resolution of the imagery used to delineate ice extent can differ by an order of magnitude, despite evidence of ongoing ice-sheet retreat. We show that using a fine resolution, time-varying ice mask significantly improves mass-balance estimates of the northwestern sector of the Greenland Ice Sheet and affects interpretation of local crustal uplift. Accounting for ice margin retreat using a time-varying ice mask between 2003–2015 results in 1.0–6.8% less ice-sheet mass loss relative to assuming one of several existing static ice masks. This indicates that mass-balance estimates that use a static ice mask will progressively overestimate mass loss where the ice sheet is predominantly retreating, meaning a negative bias on mass-balance. This trend is anticipated to be amplified in a future warming scenario unless updated ice masks are incorporated. For altimetry-derived mass-balance estimates, this ice-mask induced bias approaches the magnitude of the ice-sheet-wide uncertainty presently associated with spatiotemporal variability in modeled firn compaction. Further, at five GNET stations, the ice-mask-induced bias is equivalent to 5–15% of the modeled uplift due to elastic deformation. Given present and projected negative trends in Greenland Ice Sheet mass-balance and areal extent, we conclude that studies of its mass-balance should begin incorporating dynamic, periodically updated, fine-resolution ice masks. This methodological refinement will reduce bias in estimates of both ice-sheet mass-balance and crustal uplift.

Kristian K. Kjeldsen↗