Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC MIRRORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

First experiments with gasdynamic ion source in CW mode

A new type of ECR ion source—a gasdynamic ECR ion source—has been recently developed at the Institute of Applied Physics. The main advantages of such device are extremely high ion beam current with a current density up to 600–700 emA/cm{sup 2} in combination with low emittance, i.e., normalized RMS emittance below 0.1 π mm mrad. Previous investigations were carried out in pulsed operation with 37.5 or 75 GHz gyrotron radiation with power up to 100 kW at SMIS 37 experimental facility. The present work demonstrates the first experience of operating the gasdynamic ECR ion source in CW mode. A test bench of SMIS 24 facility has been developed at IAP RAS. 24 GHz radiation of CW gyrotron was used for plasma heating in a magnetic trap with simple mirror configuration. Initial studies of plasma parameters were performed. Ion beams with pulsed and CW high voltage were successfully extracted from the CW discharge. Obtained experimental results demonstrate that all advantages of the gasdynamic source can be realized also in CW operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PREFERENTIAL ACCELERATION AND PERPENDICULAR HEATING OF MINOR IONS IN A COLLISIONLESS CORONAL HOLE

We incorporate the cyclotron-resonant Fermi heating mechanism of Isenberg and Vasquez into an inhomogeneous, collisionless coronal hole model to investigate this kinetic process in the presence of the other known forces on the coronal hole minor ions. The model includes the effects of gravity, charge-separation electric field, and mirroring in the decreasing magnetic field of a super-radially expanding flux tube. The Fermi process, due to the existence of multiple cyclotron resonances for minor ions, acts preferentially since it is not available to thermal protons in the low-beta coronal hole. The minor ions are treated as test particles, and we consider the specific case of O{sup 5+}, which is the principal minor ion observed by the UVCS/Solar and Heliospheric Observatory instrument. We estimate an upper limit to the nonlinearly generated resonant wave power by extrapolating from the observed low-frequency fluctuations, and find that only a small fraction of this power is required to provide the observed minor ion energization. The perpendicular heating provided by this Fermi mechanism accelerates the entire minor ion distribution to high speed with respect to the bulk protons, consistent with the differentially streaming minor ion core distributions which are a distinctive property of the in situ fast solar wind. We conclude that this cyclotron-resonant Fermi process is easily capable of providing the observed preferential acceleration and heating of minor ions in the fast solar wind.

99 GENERAL AND MISCELLANEOUS↗

Nuclear structure of proton-rich unstable nucleus 28 P studied by g -factor measurement

Nuclear structure of proton-rich unstable nucleus 28 P has been studied by measuring its g-factor for the first time. The g-factor of 28 P (I π = 3 + , T 1/2 = 270.3 ms) was measured by means of β-NMR technique combined with the new polarization technique for charge exchange reaction product in the intermediate energy heavy ion collisions. The obtained g-factor of g = 0.1028(27) is very much quenched from the Schmidt value, but is well reproduced by the shell model (+0.102). Lastly, in connection with the magnetic moment of the mirror partner and the β-ray transition probability, the orbital angular momenta and intrinsic spins of protons and neutrons have been determined as $\langle{l_p}$$\rangle$ = 0.43(29), $\langle{l_n}$$\rangle$ = 1.85(29), $\langle{S_p}$) = 0.28(4), and $\langle{S_n}$$\rangle$ = 0.44(4).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

BXS Re-calibration

Early in the commissioning it was noticed by Cecile Limborg that the calibration of the BXS spectrometer magnet seemed to be different from the strength of the BX01/BX02 magnets. First the BX01/BX02 currents were adjusted to 135 MeV and the beam energy was adjusted to make the horizontal orbit flat. Then BX01/BX02 magnets were switched off and BXS was adjusted to make the horizontal orbit in the spectrometer line flat, without changing the energy of the beam. The result was that about 140-141 MeV were required on the BXS magnet. This measurement was repeated several times by others with the same results. It was not clear what was causing the error: magnet strength or layout. A position error of about 19 mm of the BXS magnet could explain the difference. Because there was a significant misalignment of the vacuum chamber in the BXS line, the alignment of the whole spectrometer line was checked. The vacuum chamber was corrected, but the magnets were found to be in the proper alignment. So we were left with one (or conceivably two) magnet calibration errors. Because BXS is a wedged shaped magnet, the bend angle depends on the horizontal position of the incoming beam. As mentioned, an offset of the beam position of 19 mm would increase or decrease the bend angle roughly by the ratio of 135/141. The figure of 19 mm is special and caused a considerable confusion during the design and measurement of the BXS magnet. This is best illustrated in Figure 1 which was taken out of the BXS Traveler document. The distance between the horizontal midplanes of the poles and the apex of the beam path was chosen to be 19 mm so the beam is close to the good field region throughout its entire path. Thus it seemed possible that there was an error that resulted in the beam not being on this trajectory, or conversely, that the magnetic measurements were done on the wrong trajectory and the magnet was then mis-calibrated. Mechanical measurements of the vacuum chamber made in the tunnel indicated that the vacuum chamber was in fact in the proper position with respect to the magnet - not 19 mm off to one side - so the former possibility was discounted. Review of the Fiducial Report and an interview with Keith Caban convinced me that there was no error in the coordinate system used for magnet measurements. I went and interviewed Andrew Fischer who did the magnetic measurements of BXS. He had extensive records, including photographs of the setups and could quickly answer quite detailed questions about how the measurement was done. Before the interview, I had a suspicion there might have been a sign flip in the x coordinate which because of the wedge would result in the wrong path length and a miscalibration. Andrew was able to pin-point how this could have happened and later confirmed it by looking an measurement data from the BXG magnet done just after BXS and comparing photographs. It turned out that the sign of the horizontal stage travel that drives the measurement wire was opposite that of the x coordinate in the Traveler, and the sign difference wasn't applied to the data. The origin x = 0 was set up correctly, but the wire moved in the opposite direction to what was expected, just as if the arc had been flipped over about the origin. To quantitatively confirm that this was the cause of the observed difference in calibration I used the 'grid data', which was taken with a Hall probe on the BXS magnet originally to measure the FINT (focusing effect) term, and combined it with the Hall probe data taken on the flipped trajectory, and performed the field integral on a path that should give the same result as the design path. This is best illustrated in Figure 2. The integration path is coincident with the desired path from the pivot points (x = 0) outward. Between the pivot points the integration path is a mirror image of the design path, but because the magnet is fairly uniform, for this portion it gives the same result. Most of the calibration error resulted simply from the different path length between the design path and the measured path. The results of the integration on the equivalent path are given in Table 1. The corrected calibration has been used to generate a new polynomial for BXS which was implemented in the control system.

43 PARTICLE ACCELERATORS↗

The effect of spectral anisotropy of fast magnetosonic turbulence on the plasma heating at the proton kinetic scales

The energy transport associated with the fast magnetosonic turbulence in a low-beta plasma is one of the possible driving forces of the solar wind. Two different kinds of the turbulence spectra are discussed in this paper: a unidirectional spectrum of the fluctuations propagating away from the sun and a bidirectional spectrum composed of the sunward and antisunward modes. The evolution of the system is analyzed with the help of hybrid numerical simulations at the proton kinetic scales. It is shown that in the unidirectional case, the heating is always preferentially across the background magnetic field. It is this property that allows the solar wind plasma to be propelled away from the sun by the mirror force of the inhomogeneous magnetic field. Adding the counterpropagating modes reverses the sense of the energy deposition with the parallel heating now dominating the process. However, the parallel heating is produced mostly by fast modes propagating along the magnetic field. If these modes are eliminated, the heating becomes perpendicular again.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and fabrication of a superconducting magnet for an 18 GHz electron cyclotron resonance ion/photon source NFRI-ECRIPS

A superconducting magnet was designed and fabricated for an 18 GHz ECR ion/photon source, which will be installed at National Fusion Research Institute (NFRI) in South Korea. The magnetic system consists of a set of four superconducting coils for axial mirror field and 36 pieces of permanent magnets for hexapolar field. The superconducting coils with a cryocooler (1.5 W - 4.2 K) allow one to reach peak mirror fields of 2.2 T in the injection and those of 1.5 T in the extraction regions on the source axis, and the resultant hexapolar field gives 1.35 T on the plasma chamber wall. The unbalanced magnetic force between the coils and surrounding yoke has been minimized to 16 ton by a coil arrangement and their electrical connection, and then was successfully suspended by 12 strong thermal insulating supports made of large numbers of carbon fibers. In order to block radiative thermal losses, multilayer thermal insulations are covered on the coil windings as well as 40-K aluminum thermal shield. Also new schemes of quench detection and safety system (coil divisions, quench detection coils, and heaters) were employed. For impregnation of the windings a special epoxy has been selected and treated to have a higher breaking strength and a higher thermal conductivity, which enables the superconductors to be uniformly and rapidly cooled down or heated during a quench.

43 PARTICLE ACCELERATORS↗

Machine Protection System for the Stepper Motor Actuated SyLMAND Mirrors

SyLMAND, the Synchrotron Laboratory for Micro and Nano Devices at the Canadian Light Source, consists of a dedicated X-ray lithography beamline on a bend magnet port, and process support laboratories in a clean room environment. The beamline includes a double mirror system with flat, chromium-coated silicon mirrors operated at varying grazing angles of incidence (4 mrad to 45 mrad) for spectral adjustment by high energy cut-off. Each mirror can be independently moved by two stepper motors to precisely control the pitch and vertical position. We present in this paper the machine protection system implemented in the double mirror system to allow for safe operation of the two mirrors and to avoid consequences of potential stepper motor malfunction.

43 PARTICLE ACCELERATORS↗

Applying alpha-channeling to mirror machines

The {alpha}-channeling effect entails the use of radio-frequency waves to expel and cool high-energetic {alpha} particles born in a fusion reactor; the device reactivity can then be increased even further by redirecting the extracted energy to fuel ions. Originally proposed for tokamaks, this technique has also been shown to benefit open-ended fusion devices. Here, the fundamental theory and practical aspects of {alpha} channeling in mirror machines are reviewed, including the influence of magnetic field inhomogeneity and the effect of a finite wave region on the {alpha}-channeling mechanism. For practical implementation of the {alpha}-channeling effect in mirror geometry, suitable contained weakly damped modes are identified. In addition, the parameter space of candidate waves for implementing the {alpha}-channeling effect can be significantly extended through the introduction of a suitable minority ion species that has the catalytic effect of moderating the transfer of power from the {alpha}-channeling wave to the fuel ions.

36 MATERIALS SCIENCE↗

MHD plasma stabilization in a chain of axisymmetric adiabatic open mirror cells

Conditions for convective plasma instability in a chain of axisymmetric adiabatic mirror cells with different signs of magnetic field curvature are analyzed. The boundaries of the region that can be occupied by a stable hollow plasma in a system of two connected cells-a nonparaxial simple mirror cell and a semicusp-are determined, as well as the interval of allowed values of the ratio between the pressures in the cells. Because of the large magnetic field curvature in the component cells, the safety factor that is achieved at both-external and internal-plasma boundaries in accordance with the average min-B principle can be high. It is assumed that the unperturbed pressure in each cell is almost isotropic, in which case the mirror ratio should necessarily be large. A key role in the stability of the plasma is played by its compressibility. A comparison is made between the conditions for complete plasma stabilization against arbitrary perturbations and the conditions for stability of individual cells against the global mode. The stability of the cells against the global mode is sufficient, but not necessary, for stabilizing the chain. The analysis is done by using orthogonal coordinates associated with the unperturbed magnetic field (flux variables). Numerical simulations were carried out for nonparaxial cells from a certain three-parameter family.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma heating and hot ion sustaining in mirror based hybrids

Possibilities of plasma heating and sloshing ion sustaining in mirror based hybrids are briefly reviewed. Sloshing ions, i.e. energetic ions with a velocity distribution concentrated to a certain pitch-angle, play an important role in plasma confinement and generation of fusion neutrons in mirror machines. Neutral beam injection (NBI) is first discussed as a method to generate sloshing ions. Numerical results of NBI modeling for a stellarator-mirror hybrid are analyzed. The sloshing ions could alternatively be sustained by RF heating. Fast wave heating schemes, i.e. magnetic beach, minority and second harmonic heating, are addressed and their similarities and differences are described. Characteristic features of wave propagation in mirror hybrid devices including both fundamental harmonic minority and second harmonic heating are examined. Minority heating is efficient for a wide range of minority concentration and plasma densities; it allows one to place the antenna aside from the hot ion location. A simple-design strap antenna suitable for this has good performance. However, this scenario is appropriate only for light minority ions. The second harmonic heating can be applied for the heavy ion component. Arrangements are similar for minority and second harmonic heating. The efficiency of second harmonic heating is influenced by a weaker wave damping than for minority heating. Numerical calculations show that in a hybrid reactor scaled mirror machine the deuterium sloshing ions could be heated within the minority heating scheme, while the tritium ions could be sustained by second harmonic heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetized ICF implosions: non-axial magnetic field topologies

This paper explores four different magnetic field topologies for application to spherical inertial confinement fusion implosions: axial, mirror, cusp and closed field lines. A mirror field is found to enhance the impact of magnetization over an axial field; this is because the mirror field more closely follows the hot-spot surface. A cusp field, while simple to generate, is not found to have any benefits over the tried-and-tested axial field. Closed field lines are found to be of the greatest benefit to hot-spot performance, with the simulated design undergoing a 2× increase in ion temperature before α-heating is considered. The plasma properties of the simulation with closed field lines are radically different from the unmagnetized counterpart, with electron temperatures in excess of 100 keV, suggesting that a fundamental redesign of the capsule implosion is possible if this method is pursued.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Suppression of magnetism and development of superconductivity within the collapsed tetragonal phase of Ca[subscript 0.67]Sr[subscript 0.33]Fe[subscript 2]As[subscript 2] under pressure

Structural and electronic characterizations of (Ca{sub 0.67}Sr{sub 0.33})Fe{sub 2}As{sub 2} have been performed as a function of pressure up to 12 GPa using conventional and designer diamond anvil cells. The compound (Ca{sub 0.67}Sr{sub 0.33})Fe{sub 2}As{sub 2} behaves intermediately between its end members, displaying a suppression of magnetism and the onset of superconductivity. Like other members of the AFe{sub 2}As{sub 2} family, (Ca{sub 0.67}Sr{sub 0.33})Fe{sub 2}As{sub 2} undergoes a pressure-induced isostructural volume collapse, which we associate with the development of As-As bonding across the mirror plane of the structure. This collapsed tetragonal phase abruptly cuts off the magnetic state and supports superconductivity with a maximum T{sub c} = 22.2 K. The maximum T{sub c} of the superconducting phase is not strongly correlated with any structural parameter, but its proximity to the abrupt suppression of magnetism as well as the volume-collapse transition suggests that magnetic interactions and structural inhomogeneity may play a role in its development.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An experimental study of the existence regions and non-linear interactions of drift wave and Kelvin–Helmholtz instabilities in a linear magnetized plasma

Experimental observations of the intrinsic excitation and non-linear interactions of drift wave (DW) and Kelvin–Helmholtz (KH) instabilities in a linear magnetized plasma column are presented. The experiments are carried out in the inverse mirror plasma experimental device (IMPED)—a cylindrical, magnetized, linear plasma machine designed to study low-frequency waves and instabilities in plasma. A novel feature of IMPED is the ability to control plasma profiles, such as the density n(r)⁠, electron temperature T e (r)⁠, and plasma potential V p (r) by varying the ratio Rm of the magnetic field in the main chamber to that in the source chamber. At high values of Rm, higher-density gradient scale length promotes the drift wave (DW) instability while lower Rm value results in a higher radial electric field, inducing a sheared poloidal flow that enhances the dominance of the Kelvin–Helmholtz (KH) mode. The background and fluctuating plasma parameters are characterized using various configurations of multiple in situ electric probes at different spatial locations to quantify the local gradients that excite the low-frequency primary instabilities. Statistical, spectral, and bispectral analysis of the density and potential signals help identify these modes in terms of wave number, frequency, phase, and amplitude and also delineate the nature of their non-linear interactions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Onset of magnetic reconnection in a collisionless, high-β plasma

In a magnetized, collisionless plasma, the magnetic moment of the constituent particles is an adiabatic invariant. An increase in the magnetic-field strength in such a plasma hence leads to an increase in the thermal pressure perpendicular to the field lines. Above a $\unicode[STIX]{x1D6FD}$ -dependent threshold (where $\unicode[STIX]{x1D6FD}$ is the ratio of thermal to magnetic pressure), this pressure anisotropy drives the mirror instability, producing strong distortions in the field lines on ion-Larmor scales. The effect of this instability on magnetic reconnection is investigated using a simple analytical model for the formation of a current sheet (CS) and the associated production of pressure anisotropy. The difficulty in maintaining an isotropic, Maxwellian particle distribution during the formation and subsequent thinning of a CS in a collisionless plasma, coupled with the low threshold for the mirror instability in a high- $\unicode[STIX]{x1D6FD}$ plasma, imply that the geometry of reconnecting magnetic fields can differ radically from the standard Harris-sheet profile often used in simulations of collisionless reconnection. Because of this, depending on the rate of CS formation and the initial CS thickness, tearing modes whose growth rates and wavenumbers are boosted by this difference may disrupt the mirror-infested CS before standard tearing modes can develop. A quantitative theory is developed to illustrate this process, which may find application in the tearing-mediated disruption of kinetic magnetorotational ‘channel’ modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Variational approach for static mirror structures

Anisotropic static plasma equilibria where the parallel and perpendicular pressures are only functions of the amplitude of the local magnetic field are shown to be amenable to a variational principle with a free energy density given by the parallel tension. This approach is used to demonstrate that two-dimensional small-amplitude static magnetic holes constructed from a Grad-Shafranov type equation slightly below the (subcritical) mirror instability threshold identify with lump solitons of KPII equation, but turn out to be unstable. Differently, large-amplitude magnetic structures, which are stable as they realize a minimum of the free energy, are computed using a gradient method within two-dimensional numerical simulations where the regularizing effect of finite Larmor radius corrections is retained. Interestingly, these structures transform from stripes to bubbles when the angle of the magnetic field with the coordinate plane is increased.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic anisotropy due to the Casimir effect

We consider the Casimir interaction between a ferromagnetic and a nonmagnetic mirror and show how the Casimir effect gives rise to a magnetic anisotropy in the ferromagnetic layer. The anisotropy is out of plane if the nonmagnetic plate is optically isotropic. If the nonmagnetic plate shows a uniaxial optical anisotropy (with optical axis in the plate plane), we find an in-plane magnetic anisotropy. In both cases, the energetically most favorable magnetization orientation is given by the competition between polar, longitudinal, and transverse contributions to the magneto-optical Kerr effect and will therefore depend on the interplate distance. Numerical results will be presented for a magnetic plate made out of Fe and nonmagnetic plates of Au (optically isotropic), quartz, calcite, and barium titanate (all uniaxially birefringent).

36 MATERIALS SCIENCE↗

Magnetic Measurement Results of the LCLS Undulator Quadrupoles

This note details the magnetic measurements and the magnetic center fiducializations that were performed on all of the thirty-six LCLS undulator quadrupoles. Temperature rise, standardization reproducibility, vacuum chamber effects and magnetic center reproducibility measurements are also presented. The Linac Coherent Light Source (LCLS) undulator beam line has 33 girders, each with a LCLS undulator quadrupole which focuses and steers the beam through the beam line. Each quadrupole has main quadrupole coils, as well as separate horizontal and vertical trim coils. Thirty-six quadrupoles, thirty-three installed and three spares were, manufactured for the LCLS undulator system and all were measured to confirm that they met requirement specifications for integrated gradient, harmonics and for magnetic center shifts after current changes. The horizontal and vertical dipole trims of each quadrupole were similarly characterized. Each quadrupole was also fiducialized to its magnetic center. All characterizing measurements on the undulator quads were performed with their mirror plates on and after a standardization of three cycles from -6 to +6 to -6 amps. Since the undulator quadrupoles could be used as a focusing or defocusing magnet depending on their location, all quadrupoles were characterized as focusing and as defocusing quadrupoles. A subset of the undulator quadrupoles were used to verify that the undulator quadrupole design met specifications for temperature rise, standardization reproducibility and magnetic center reproducibility after splitting. The effects of the mirror plates on the undulator quadrupoles were also measured.

43 PARTICLE ACCELERATORS↗