Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC FORMING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Stripe antiferromagnetism and disorder in the Mott insulator NaFe 1₋ x Cu x As ( x ≲0.5)

Neutron scattering measurements have demonstrated that the heavily Cu doped NaFe 1₋ x Cu x As compound behaves like a Mott insulator exhibiting both real-space Fe-Cu stripes and antiferromagnetism below a Néel temperature for x ≲ 0.5. In this work, we have investigated the evolution of structural and magnetic ordering using 23 Na and 75 As NMR for single crystals ( x = 0.39 and 0.48), confirming antiferromagnetism in the form of magnetic stripes. We show that end-chain defects in these stripes are the principal source of magnetic disorder and are responsible for cluster spin-glass transitions in both compounds, in the latter case coexistent with antiferromagnetism. Aided by our numerical simulation of the 75 As spectra, we show that a staggered magnetization at the Fe sites is induced by nonmagnetic Cu dopants.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Additive manufacturing of permanent magnets

Permanent magnets are an essential technology for energy conversion. Motors and generators are used to convert energy between electrical and mechanical forms. Permanent magnets must be pre-charged (magnetized) prior to their use in an application and must maintain this magnetization during operation. In addition, permanent magnets must generate sufficient magnetic flux for a given application. Nevertheless, permanent magnets can be demagnetized by a number of circumstances, including the presence of other magnetic materials in their service, temperature changes (thermal demagnetization), microstructural degradation, and even the magnet’s own internal demagnetizing field. Therefore, the performance of a permanent magnet can be best understood by examining its ability to withstand demagnetization and to supply the magnetic flux required in a given application. Some of these properties are discussed further. Additive manufacturing, followed by exchange spring magnets will be discussed later.

42 ENGINEERING↗

Fabrication method for a component having magnetic and non-magnetic dual phases

Methods for forming a dual-phase magnetic component from an initial component comprising a non-magnetic austenite composition are provided. The method may include: forming a coating on a portion of the surface of the initial component to form a masked area while leaving an unmasked area thereon. Thereafter the initial component may be heated to a treatment temperature such that nitrogen diffuses out of the unmasked area of the initial component to transform the non-magnetic austenite composition to a magnetic phase in the unmasked area. Thereafter, the initial component may be cooled from the treatment temperature to form a dual-phase magnetic component having a magnetic region corresponding to the unmasked area and a non-magnetic region corresponding to the masked area.

Huang, Shenyan↗

Giant electron–phonon coupling of the breathing plane oxygen phonons in the dynamic stripe phase of $\hbox {La}_{1.67}\hbox {Sr}_{0.33}\hbox {NiO}_4$

Doped antiferromagnets host a vast array of physical properties and learning how to control them is one of the biggest challenges of condensed matter physics. La 1.67 Sr 0.33 NiO 4 (LSNO) is a classic example of such a material. At low temperatures holes introduced via substitution of La by Sr segregate into lines to form boundaries between magnetically ordered domains in the form of stripes. The stripes become dynamic at high temperatures, but LSNO remains insulating presumably because an interplay between magnetic correlations and electron–phonon coupling localizes charge carriers. Magnetic degrees of freedom have been extensively investigated in this system, but phonons are almost completely unexplored. We searched for electron–phonon anomalies in LSNO by inelastic neutron scattering. Giant renormalization of plane Ni–O bond-stretching modes that modulate the volume around Ni appears on entering the dynamic charge stripe phase. Other phonons are a lot less sensitive to stripe melting. Dramatic overdamping of the breathing modes indicates that dynamic stripe phase may host small polarons. We argue that this feature sets electron–phonon coupling in nickelates apart from that in cuprates where breathing phonons are not overdamped and point out remarkable similarities with the colossal magnetoresistance manganites.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Strain-induced spontaneous Hall effect in an epitaxial thin film of a Luttinger semimetal

Pyrochlore iridates have offered a plethora of novel phenomena owing to the combination of topology and correlation. Among them, much attention has been paid to P r 2 I r 2 O 7 , as it is known as a Luttinger semimetal characterized by quadratic band touching at the Brillouin zone center, suggesting that the topology of its electronic states can be tuned by a moderate lattice strain and external magnetic field. In this work, we report that our epitaxial P r 2 I r 2 O 7 thin films grown by solid-state epitaxy exhibit a spontaneous Hall effect that persists up to 50 K without having spontaneous magnetization within our experimental accuracy. This indicates that the system breaks the time reversal symmetry at a temperature scale that is too high for the magnetism to be due to Pr 4f moments and must be related to magnetic order of the iridium 5d electrons. Moreover, our analysis finds that the chiral anomaly induces the negative contribution to the magnetoresistance only when a magnetic field and the electric current are parallel to each other. Our findings suggest that the strained part of the thin film forms a magnetic Weyl semimetal state.

36 MATERIALS SCIENCE↗

ON HIGHLY CLUMPED MAGNETIC WIND MODELS FOR COOL EVOLVED STARS

Recently, it has been proposed that the winds of non-pulsating and non-dusty K and M giants and supergiants may be driven by some form of magnetic pressure acting on highly clumped wind material. While many researchers believe that magnetic processes are responsible for cool evolved stellar winds, existing MHD and Alfven wave-driven wind models have magnetic fields that are essentially radial and tied to the photosphere. The clumped magnetic wind scenario is quite different in that the magnetic flux is also being carried away from the star with the wind. We test this clumped wind hypothesis by computing continuum radio fluxes from the {zeta} Aur semiempirical model of Baade et al., which is based on wind-scattered line profiles. The radio continuum opacity is proportional to the electron density squared, while the line scattering opacity is proportional to the gas density. This difference in proportionality provides a test for the presence of large clumping factors. We derive the radial distribution of clump factors (CFs) for {zeta} Aur by comparing the nonthermal pressures required to produce the semiempirical velocity distribution with the expected thermal pressures. The CFs are {approx}5 throughout the sub-sonic inner wind region and then decline outward. These implied clumping factors lead to excess radio emission at 2.0 cm, while at 6.2 cm it improves agreement with the smooth unclumped model. Smaller clumping factors of {approx}2 lead to better overall agreement but also increase the discrepancy at 2 cm. These results do not support the magnetic clumped wind hypothesis and instead suggest that inherent uncertainties in the underlying semiempirical model probably dominate uncertainties in predicted radio fluxes. However, new ultraviolet line and radio continuum observations are needed to test the new generations of inhomogeneous magnetohydrodynamic wind models.

79 ASTRONOMY AND ASTROPHYSICS↗

The first taste of a hot channel in interplanetary space

A hot channel (HC) is a high temperature (∼10 MK) structure in the inner corona first revealed by the Atmospheric Imaging Assembly on board the Solar Dynamics Observatory. Eruptions of HCs are often associated with flares and coronal mass ejections (CMEs). Results of previous studies have suggested that an HC is a good proxy for a magnetic flux rope (MFR) in the inner corona as well as another well known MFR candidate, the prominence-cavity structure, which has a normal coronal temperature (∼1–2 MK). In this paper, we report a high temperature structure (HTS, ∼1.5 MK) contained in an interplanetary CME induced by an HC eruption. According to the observations of bidirectional electrons, high temperature and density, strong magnetic field, and its association with the shock, sheath, and plasma pile-up region, we suggest that the HTS is the interplanetary counterpart of the HC. The scale of the measured HTS is around 14 R {sub ⊙}, and it maintained a much higher temperature than the background solar wind even at 1 AU. It is significantly different from the typical magnetic clouds, which usually have a much lower temperature. Our study suggests that the existence of a corotating interaction region ahead of the HC formed a magnetic container to inhibit expansion of the HC and cool it down to a low temperature.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnet and lattice specifications for the CBETA first girder

The CBETA project recently chose to use Halbach magnets to form the FFAG lattice. A first FFAG arc girder will be constructed on a short time-scale so a suitable lattice using Halbach magnets is required. This document gives the specification of the magnets as well as their placement and the optics of the cell as calculated using the Muon1 code, as these things are strongly coupled.

43 PARTICLE ACCELERATORS↗

Measurement of the Neutron Electromagnetic Form Factors at High Momentum Transfer Using a Polarized 3He Target at Jefferson Lab

Ever since the composite structure of nucleons was uncovered, many experiments have been commissioned with the purpose of extracting parameters that shape our understanding of this structure. Form factors are powerful tools that rest at the forefront of the nucleon structure study. In the non-relativistic limit, they describe the magnetic and charge distributions inside the nucleon. The GEn-II experiment, which ran in Hall A of Jefferson Lab as a part of the SuperBigbite Spectrometer (SBS) program, aimed to extract the ratio of the neutron’s electric to magnetic Sachs form factors (GnE/GnM. This was accomplished using the double polarization technique: scattering polarized electrons with initial energies up to 8.45 GeV off high-density polarized 3He targets. The experiment was a coincidence measurement, with the scattered electrons detected in the BigBite Spectrometer and the recoil nucleons in a hadron calorimeter, a part of the SuperBigbite Spectrometer. The convection-style target cells used in this experiment have a 60cm long target chamber, an increase from the 40 cm cell used in the most recent polarized 3He target experiment. In addition, the cells were optically pumped from two sides of the pumping chamber. These improvements in design and functionality introduced world-record-breaking luminosity. This thesis presents preliminary results of the GEn-II experiment for the following 4-momentum transfer (Q2) values: 2.93, 6.76, and 9.78 GeV2, in addition to target performance and preliminary polarimetry results.

Presley, Hunter [Univ. of Virginia, Charlottesvill↗

Magnetic material including α″-Fe16(NxZ1-x)2 or a mixture of α″-Fe16Z2 and α″-Fe16N2, where Z includes at least one of C, B, or O

A magnetic material may include α″-Fe16(NxZ1-x)2 or a mixture of α″-Fe16N2 and α″-Fe16Z2, where Z includes at least one of C, B, or O, and x is a number greater than zero and less than one. In some examples, the magnetic material including α″-Fe16(NxZ1-x)2 or a mixture of α″-Fe16N2 and α″-Fe16Z2 may include a relatively high magnetic saturation, such as greater than about 219 emu/gram, greater than about 242 emu/gram, or greater than about 250 emu/gram. In addition, in some examples, the magnetic material including α″-Fe16(NxZ1-x)2 or a mixture of α″-Fe16N2 and α″-Fe16Z2 may include a relatively low coercivity. Techniques for forming the magnetic material are also described.

36 MATERIALS SCIENCE↗

Studies of Nucleon Form Factors with 12 GeV CEBAF and SuperBigBite

The elastic electromagnetic form factors are among the most fundamental quantities that describe the ground-state structure of the proton and neutron. Precision data of the form factors over a wide kinematical range provide a powerful test of current theories of hadron structure. A number of experiments aiming to measure the electric and magnetic elastic form factors of the neutron, G{sub E}{sup n} and G{sub M}{sup n}, and proton, G{sub E}{sup p}, at very high momentum transfer, up to the range of Q{sup 2} = 10-14 (GeV/c){sup 2}, are planned to be carried out with the future 11 GeV electron beam of the upgraded CEBAF at Jefferson Lab. These experiments will determine the nucleon form factors with unprecedented precision to Q{sup 2}-values up to three times higher than those of existing data. We review the approved proposals and the conceptual design of a new spectrometer, SuperBigBite, that will be used in these and other future experiments at Jefferson Lab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Meissner-London Susceptibility of Superconducting Right Circular Cylinders in an Axial Magnetic Field

Analysis of magnetic susceptibility of nonellipsoidal samples is a long-standing problem in experimental studies of magnetism and superconductivity. Here the quantitative description of the Meissner-London response (no Abrikosov vortices) of right circular cylinders in an axial magnetic field is given. Three-dimensional adaptive finite-element modeling is used to calculate the total magnetic moment ( m ) in a wide range of London penetration depth ( λ ) to sample size ( a ) ratios, λ /a. Furthermore, by fitting numerical solutions, the closed-form empirical magnetic susceptibility is obtained involving only sample dimensions and λ, thus providing a recipe for determining the London penetration depth from the precision measurements of the magnetic susceptibility. Detailed protocols of the experimental data analysis using the developed approach are given. The results can be readily extended to the most frequently used cuboid-shaped samples.

3-dimensional systems↗

Comparison Of Electromagnetic, Electrostatic And Permanent Magnet Quadrupole Lens Probe-Forming Systems For High Energy Ions

The focusing system is an essential part of any ion microbeam system and focusing of MeV ion beams is generally accomplished using quadrupole lenses. There are two types of quadrupole lenses requiring the application of either voltage or current to provide the excitation, but there is also the possibility of utilizing lenses constructed from permanent magnets. All of these lens types have different advantages and disadvantages. Most microprobes employ electromagnetic quadrupoles for focusing, however electrostatic lenses have several advantages with respect to electromagnetic lenses, including significantly smaller size, no hysteresis effects, no heating, the utilization of highly stable voltage supplies, focusing which is independent of ion mass, and construction from industrial grade materials. The main advantage of the permanent magnetic lens is that it does not require the application of external power which can significantly reduce the overall lifetime cost. In this presentation, the short probe-forming systems comprised from all these types of quadrupole lenses are compared and the smallest beam spot size and appropriate optimal parameters of these probe-forming systems are determined.

43 PARTICLE ACCELERATORS↗

Magnetic and transport properties of RCr{sub 0.3}Ge{sub 2} (R=Tb, Dy, Ho and Er) compounds

The magnetic and transport properties of ternary rare-earth chromium germanides RCr{sub 0.3}Ge{sub 2} (R=Y and Tb-Er) have been determined. X-ray and neutron diffraction studies indicate that these compounds have the CeNiSi{sub 2}-type structure (space group Cmcm) . Magnetic measurements reveal the antiferromagnetic ordering below T{sub N} equal to 18.5 K (R=Tb), 11.8 K (Dy), 5.8 K (Ho) and 3.4 K (Er). From the neutron diffraction data the magnetic structures have been determined. For TbCr{sub 0.3}Ge{sub 2} and DyCr{sub 0.3}Ge{sub 2} at low temperatures the magnetic ordering can be described by two vectors k{sub 1}=(1/2 ,0,0) and k{sub 2}=(1/4 ,0,1/4), and k{sub 1}'=(1/2 ,0,0) and k{sub 2}'=(1/2 ,0,1/2), respectively. In HoCr{sub 0.3}Ge{sub 2} and ErCr{sub 0.3}Ge{sub 2} the ordering can be described by one propagation vector equal to (1/2 ,1/2 ,0) and (0,0,0.4187(2)), respectively. In DyCr{sub 0.3}Ge{sub 2} some change in the magnetic ordering is observed at T{sub t}=5.1 K. In temperature range from T{sub t} to T{sub N} the magnetic ordering is given by one propagation vector k=(1/2 ,0,0). YCr{sub 0.3}Ge{sub 2} is a Pauli paramagnet down to 1.72 K which suggests that in the entire RCr{sub 0.3}Ge{sub 2} series the Cr atoms do not carry magnetic moments. All compounds studied exhibit metallic character of the electrical conductivity. The temperature dependencies of the lattice parameters reveal strong magnetostriction effect at the respective Neel temperatures. -- Graphical abstract: In the neutron diffraction pattern of TbCr{sub 0.3}Ge{sub 2} compound collected at 1.5 K the additional peaks of magnetic origin form two groups. The first one, with strong intensities, can be indexed by the propagation vector k=(1/2 ,0,0) (a), while the second one, with small intensities, can be described by the propagation vector k=(1/4 ,0,1/4) (b). The analysis of the magnetic peak intensities indicates that the Tb magnetic moments located at the positions Tb1 (0,y,1/4), Tb2 (0,-y,3/4), Tb3 (1/2 ,1/2 +y,1/4) and Tb4 (1/2 ,1/2 -y,3/4) form a collinear structure with the (+ + - -) sequence in the crystallographic unit cell for the first component and (- + + -) for the second. Display Omitted

36 MATERIALS SCIENCE↗

Unusual spin gap transition observed in two new molecular magnets based on [Ni(mnt){sub 2}]{sup -} monoanion (mnt{sup 2-}=maleonitriledithiolate)

Two new molecular magnets, [RBzPyN(CH{sub 3}){sub 2}][Ni(mnt){sub 2}] [mnt{sup 2-}=maleonitriledithiolate; [RBzPyN(CH{sub 3}){sub 2}]{sup +}=1-(4'-R-benzyl)-4-dimethylaminopyridinium; R=CN(1), F(2)], with unusual magnetic properties have been prepared and characterized. Both 1 and 2 form a 3D network structure in which the [Ni(mnt){sub 2}]{sup -} anions form a 1D magnetic chain for 1 and a stepwise stack for 2via weak {pi}...{pi} stacking interactions, C...C or C...N short interactions between the neighboring anions. Magnetic susceptibility measurements in the temperature range 1.8-300 K indicated that 1 and 2 show unusual spin gap transition around 30 K and 110 K, respectively. The transition for 1 and 2 is the second-order phase transition as determined by the capacity measurement. - Graphical Abstract: Two new molecular magnets based on [Ni(mnt){sub 2}]{sup -} monoanion form a 1D magnetic chain for 1 and a stepwise stack for 2, and exhibit unusual spin gap transition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A liquid-helium-free superconducting coil system forming a flat minimum-magnetic-field distribution of an electron cyclotron resonance ion source

A flat distribution of the minimum magnetic field (flat-B{sub min}) of an electron cyclotron resonance ion source (ECRIS) is expected to perform better in highly charged ion production than classical B{sub min}. To form a flat-B{sub min} structure with a liquid helium-free superconducting device, a coil system of seven coils with four current leads has been designed. The lead number was reduced by connecting the plural coils in series to maintain the flat-B{sub min} structure even when the coil currents are changed for adjustment. This coil system can be operated with a helium-free cryostat, since the estimation of heat from the leads to the coils is nearly equivalent to the existing superconducting ECRIS of a similar type.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anisotropy of radiation emitted from planar wire arrays

The planar wire array (PWA) is a promising load for new multi-source inertial confinement fusion (ICF) hohlraums [B. Jones et al., Phys. Rev. Lett. 104, 125001 (2010)]. The hohlraum radiation symmetry is an important issue for ICF. It was found that extreme ultraviolet and sub-keV photon emission from PWAs may have considerable anisotropy in the load azimuthal plane. This experimental result is obtained on the UNR 1–1.7 MA Zebra generator. The time-dependent anisotropy effect is detected. This feature is studied in 2D numerical simulations and can be explained by initial anisotropy of implosion of those non-cylindrical loads radiating essentially as surface sources in sub-keV quanta and also by radiation absorption in cold magnetized plasma tails forming in the direction of magnetic compression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a compact ECR ion source for various ion production

There is a desire that a carbon-ion radiotherapy facility will produce various ion species for fundamental research. Although the present Kei2-type ion sources are dedicated for the carbon-ion production, a future ion source is expected that could provide: (1) carbon-ion production for medical use, (2) various ions with a charge-to-mass ratio of 1/3 for the existing Linac injector, and (3) low cost for modification. A prototype compact electron cyclotron resonance (ECR) ion source, named Kei3, based on the Kei series has been developed to correspond to the Kei2 type and to produce these various ions at the National Institute of Radiological Sciences (NIRS). The Kei3 has an outer diameter of 280 mm and a length of 1120 mm. The magnetic field is formed by the same permanent magnet as Kei2. The movable extraction electrode has been installed in order to optimize the beam extraction with various current densities. The gas-injection side of the vacuum chamber has enough space for an oven system. We measured dependence of microwave frequency, extraction voltage, and puller position. Charge state distributions of helium, carbon, nitrogen, oxygen, and neon were also measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗