Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LOOPS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Similarity Metrics for Closed Loop Dynamic Systems

To what extent and in what ways can two closed-loop dynamic systems be said to be "similar?" This question arises in a wide range of dynamic systems modeling and control system design applications. For example, bounds on error models are fundamental to the controller optimization with modern control design methods. Metrics such as the structured singular value are direct measures of the degree to which properties such as stability or performance are maintained in the presence of specified uncertainties or variations in the plant model. Similarly, controls-related areas such as system identification, model reduction, and experimental model validation employ measures of similarity between multiple realizations of a dynamic system. Each area has its tools and approaches, with each tool more or less suited for one application or the other. Similarity in the context of closed-loop model validation via flight test is subtly different from error measures in the typical controls oriented application. Whereas similarity in a robust control context relates to plant variation and the attendant affect on stability and performance, in this context similarity metrics are sought that assess the relevance of a dynamic system test for the purpose of validating the stability and performance of a "similar" dynamic system. Similarity in the context of system identification is much more relevant than are robust control analogies in that errors between one dynamic system (the test article) and another (the nominal "design" model) are sought for the purpose of bounding the validity of a model for control design and analysis. Yet system identification typically involves open-loop plant models which are independent of the control system (with the exception of limited developments in closed-loop system identification which is nonetheless focused on obtaining open-loop plant models from closed-loop data). Moreover the objectives of system identification are not the same as a flight test and hence system identification error metrics are not directly relevant. In applications such as launch vehicles where the open loop plant is unstable it is similarity of the closed-loop system dynamics of a flight test that are relevant.

Whorton, Mark S.↗

Simulated Time Lags of Hinode/XRT and SDO/AIA Lightcurves as an Indication of Loop Heating Scenario

The precise nature of the heating mechanism (location, duration) in coronal loops is still a matter of enormous research. We present results from a 1D hydrodynamic loop simulation of a coronal loop which was run using different parameters such as loops length (50, 200, and 500 Mm), maximum temperature reached (3MK and 10MK), and abundances. For each scenario the model outputs were used to calculate the corresponding lightcurves as seen by XRT/Be-thin and various EUV AIA channels. The lag time between the peak of these lightcurves was computed using cross-correlation and plotted as a function of loop length. Additional results were computed using the 0D EBTEL code in order to test the compatibility of the two codes and to investigate additional loop lengths. Initial results indicate that the long (greater than 5000s) lags observed in the approx. 100Mm loops of active regions can only be reproduced using photospheric abundances and much longer loop lengths.

Alexander, Caroline↗

Introduction to Loop Heat Pipes

This is the presentation file for the short course Introduction to Loop Heat Pipes, to be conducted at the 2015 Thermal Fluids and Analysis Workshop, August 3-7, 2015, Silver Spring, Maryland. This course will discuss operating principles and performance characteristics of a loop heat pipe. Topics include: 1) pressure profiles in the loop; 2) loop operating temperature; 3) operating temperature control; 4) loop startup; 4) loop shutdown; 5) loop transient behaviors; 6) sizing of loop components and determination of fluid inventory; 7) analytical modeling; 8) examples of flight applications; and 9) recent LHP developments.

Heat Pipes↗

Suppression of Heating of Coronal Loops Rooted in Opposite Polarity Sunspot Umbrae

EUV observations of active region (AR) coronae reveal the presence of loops at different temperatures. To understand the mechanisms that result in hotter or cooler loops, we study a typical bipolar AR, near solar disk center, which has moderate overall magnetic twist and at least one fully developed sunspot of each polarity. From AIA 193 and 94 Å images we identify many clearly discernible coronal loops that connect plage or a sunspot of one polarity to an opposite-­polarity plage region. The AIA 94 Å images show dim regions in the umbrae of the spots. To see which coronal loops are rooted in a dim umbral area, we performed a non-linear force‐free field (NLFFF) modeling using photospheric vector magnetic field measurements obtained with the Heliosesmic Magnetic Imager (HMI) onboard SDO. The NLFFF model, validated by comparison of calculated model field lines with observed loops in AIA 193 and 94 Å, specifies the photospheric roots of the model field lines. Some model coronal magnetic field lines arch from the dim umbral area of the positive-polarity sunspot to the dim umbral area of a negative-polarity sunspot. Because these coronal loops are not visible in any of the coronal EUV and X-ray images of the AR, we conclude they are the coolest loops in the AR. This result suggests that the loops connecting opposite polarity umbrae are the least heated because the field in umbrae is so strong that the convective braiding of the field is strongly suppressed.

sunspots↗

Role of Compressive Viscosity and Thermal Conductivity on the Damping of Slow Waves in Coronal Loops with and Without Heating–Cooling Imbalance

In the present article, we derive a new dispersion relation for slow magnetoacoustic waves invoking the effect of thermal conductivity, compressive viscosity, radiation, and an unknown heating term along with the consideration of heating–cooling imbalance from linearized MHD equations. We solve the general dispersion relation to understand the role of compressive viscosity and thermal conductivity in the damping of slow waves in coronal loops with and without heating–cooling imbalance. We have analyzed the wave damping for the range of loop length L=50--500 Mm, temperature T=5--30 MK, and density ρ=10^(−11)--10^(−9) kg/cu.m. It was found that the inclusion of compressive viscosity along with thermal conductivity significantly enhances the damping of the fundamental mode oscillations in shorter (e.g. L=50 Mm) and super-hot (T>10 MK) loops. However, the role of viscosity in the damping is insignificant in longer (e.g. L=500 Mm) and hot loops (T≤10 MK) where, instead, thermal conductivity along with the presence of heating–cooling imbalance plays a dominant role. For shorter loops at a super-hot regime of temperature, the increment in the loop density substantially enhances the damping of the fundamental modes due to thermal conductivity when viscosity is absent, however, when the compressive viscosity is added the increase in density substantially weakens the damping. Thermal conductivity alone is found to play a dominant role in longer loops at lower temperatures (T≤10 MK), while compressive viscosity dominates the damping at super-hot temperatures (T>10 MK) in shorter loops. The predicted scaling law between damping time (τ) and wave period (P) is found to better match the observed SUMER (Solar Ultraviolet Measurements of Emitted Radiation) oscillations when the heating–cooling imbalance is taken into account in addition to thermal conductivity and compressive viscosity for the damping of the fundamental slow mode oscillations.

Abhinav Prasad↗

Iterative structure of finite loop integrals

In this paper we develop further and refine the method of differential equations for computing Feynman integrals. In particular, we show that an additional iterative structure emerges for finite loop integrals. As a concrete non-trivial example we study planar master integrals of light-by-light scattering to three loops, and derive analytic results for all values of the Mandelstam variables s and t and the mass m. We start with a recent proposal for defining a basis of loop integrals having uniform transcendental weight properties and use this approach to compute all planar two-loop master integrals in dimensional regularization. We then show how this approach can be further simplified when computing finite loop integrals. This allows us to discuss precisely the subset of integrals that are relevant to the problem. We find that this leads to a block triangular structure of the differential equations, where the blocks correspond to integrals of different weight. We explain how this block triangular form is found in an algorithmic way. Another advantage of working in four dimensions is that integrals of different loop orders are interconnected and can be seamlessly discussed within the same formalism. We use this method to compute all finite master integrals needed up to three loops. Finally, we remark that all integrals have simple Mandelstam representations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the origin and behavior of irradiation-induced c-component dislocation loops in magnesium

C-component dislocation loops are one of the unique defects in hexagonal close-packed (hcp) crystals that promote the accelerated growth and void formation under irradiation. In this paper, we report in situ observation of c-component dislocation loop formation in Mg under electron irradiation with emphasis on their atomic structures. Aberration-corrected scanning transmission electron microscopy imaging is utilized to reveal four possible types of double-layer loops, which were identified as different types of stacking fault and dislocation core structures. Triple- and quadruple-layer c-component dislocation loops were also observed. The formation mechanisms of the four types of double-layer loops were revealed via molecular dynamics simulations. The experimentally observed formation rate of the single- and double-layer dislocation loops is controlled by their formation energies. Finally, our direct experimental observations in combination with molecular dynamics simulations provide fundamental insight into the mechanisms governing nucleation and growth of the c-component dislocation loops as well as their interactions, which could potentially help with future development of irradiation-resistant materials.

36 MATERIALS SCIENCE↗

Dislocation loop evolution during in-situ ion irradiation of model FeCrAl alloys

Model FeCrAl alloys of Fe-10%Cr-5%Al, Fe-12%Cr-4.5%Al, Fe-15%Cr-4%Al, and Fe-18%Cr-3%Al (in wt %) were irradiated with 1 MeV Kr++ ions in-situ with transmission electron microscopy to a dose of 2.5 displacements per atom (dpa) at 320 °C. In all cases, the microstructural damage consisted of dislocation loops with ½< 111 > and <100 > Burgers vectors. The proportion of ½< 111 > dislocation loops varied from ~50% in the Fe-10%Cr-5%Al model alloy and the Fe-18Cr%-3%Al model alloy to a peak of ~80% in the model Fe-15%Cr-4.5%Al alloy. The dislocation loop volume density increased with dose for all alloys and showed signs of approaching an upper limit. The total loop populations at 2.5 dpa had a slight (and possibly insignificant) decline as the chromium content was increased from 10 to 15 wt %, but the Fe-18%Cr-3%Al alloy had a dislocation loop population ~50% smaller than the other model alloys. As a result, the largest dislocation loops in each alloy had image sizes of close to 20 nm in the micrographs, and the median diameters for all alloys ranged from 6 to 8 nm. Nature analysis by the inside-outside method indicated most dislocation loops were interstitial type.

36 MATERIALS SCIENCE↗

Computer Simulations of Interstitial Loop Growth Kinetics in irradiated bcc Fe

The growth kinetics of (001) [001] interstitial loops in bcc Fe is studied by phase-field modeling. The effect of defect (vacancy/interstitial) concentration, generation, recombination, sink strength, and elastic interaction on the growth kinetics of interstitial loops is systematically simulated. Results show that the elastic interaction between the defects and interstitial loops speeds up the growth kinetics and affects the morphology of the interstitial loops. Linear growth rate, i.e., the loop average radius is linear to time, under both aging and irradiation are predicted, which is in agreement with experimental observation. The results also show that the interstitial loop growth rate, which is directly related to the sink strength of the interstitial loop for interstitials, increases linearly with the initial interstitial concentration during aging while changing logarithmically with the interstitial generation rate under irradiation.

growth kinetics↗

Simulation of the interaction between an edge dislocation and $\langle$111$\rangle$ interstitial dislocation loops in α-iron

The dependence of the interactions of intermediate-size ½<111> self-interstitial atom (SIA) loops with an edge dislocation on strain rate and temperature was discovered by molecular dynamics (MD) simulations for the interatomic potential derived by Ackland et al. (A97). For low temperatures ($T$ =1 K), the mechanisms of the interactions were in agreement with recent literature. It was demonstrated that a second passing of the dislocation through the loop led to a different mechanism than the one that occurred upon first passing. Since these mechanisms are associated with different SIA loop sizes, and since the loop lost a number of SIAs upon first interaction, it was deduced that the dividing threshold between large and small loops (rendering them strong or weak obstacles, respectively) is at the vicinity of the loop size studied (169 SIAs). For higher temperatures ($T$ = 300 K), the strain rate dependence proved strong: for low strain rates, the dislocation absorbed the loop as a double super-jog almost immediately and continued its glide unimpeded. For a high strain rate, the dislocation was initially pinned due to the formation of an almost sessile segment leading to high critical stress.

36 MATERIALS SCIENCE↗

Development of control quality factor for HVAC control loop performance assessment I—Methodology (ASHRAE RP-1587)

This article is the second paper from the ASHRAE research project RP-1587, focusing on the methodology of obtaining a control quality factor (CQF). This article presents a development of two CQFs for assessing the heating, ventilation, and air-conditioning (HVAC) control loop performance. Both CQFs are able to detect whether the control loop is able to maintain the setpoint and identify the loop's ability to handle disturbances. In addition, the reversal behaviors are assessed as well. The first CQF (CQF-Harris) is proposed based on the normalized Harris index using the recursive least squares method. This recursive least squares method is selected because of its computational efficiency compared with the maximum likelihood estimation method. The second CQF (CQF-EWMA) is based on the exponentially weighted moving average of the error ratio. The assessment scale of excellent, good, fair, bad, and failed, which indicates the quality of the HVAC control loops, is established as well. The sensitivity analysis for both CQFs is also conducted, and it provides insights on choosing the appropriate parameters to compute such CQFs. Such parameters include the sampling frequency, the length of the moving window, and the variance of the unmeasured disturbance. The field evaluations and tests of the proposed CQFs for simulated control loops and real control loops can be found in the companion paper with the title 'Development of Control Quality Factor for HVAC Control Loop Performance Assessment - III: Field Testing and Results (ASHRAE RP-1587).'

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of Weak-Beam Dark-Field STEM for Dislocation Loop Analysis

Nanoscale dislocation loops formed by irradiation can significantly contribute to both irradiation hardening and embrittlement of materials when subjected to extreme nuclear reactor environments. Here, this study explores the application of weak-beam dark-field (WBDF) scanning transmission electron microscopy (STEM) methods for quantitative irradiation-induced defect analysis in crystalline materials, with a specific focus on dislocation loop imaging and analysis. A high-purity Fe-5 wt% Cr model alloy was irradiated with 8 MeV Fe 2+ ions at 450°C to a fluence of 8.8 × 10 19 m -2 , inducing dislocation loops for analysis. While transmission electron microscopy (TEM) has traditionally been the primary tool for dislocation imaging, recent advancements in STEM technology have reignited interest in using STEM for defect imaging. This study introduces and compares three WBDF STEM methods, demonstrating their effectiveness in suppressing background contrasts, isolating defect information for dislocation loop type classification, providing finer dislocation line images for small loop analysis, and presenting inside–outside contrast for identifying loop nature. Experimental findings indicate that WBDF STEM methods surpass traditional TEM approaches, yielding clearer and more detailed images of dislocation loops. The study concludes by discussing the potential applications of WBDF STEM techniques in defect analysis, emphasizing their adaptability across various material systems beyond nuclear materials.

36 MATERIALS SCIENCE↗

Improvement of Alstom's Limestone-Based Chemical Looping Combustion Process for Higher Purity Flue Gas Production

Alstom Power Inc., a wholly owned subsidiary of the General Electric Company (GE), is developing Limestone-based Chemical Looping (LCL™) Processes, utilizing limestone derived calcium sulfate as an oxygen carrier to transport oxygen from air to the fuel. The LCL™ process is a breakthrough technology with the potential to capture CO 2 and SO 2 from new and existing coal-fired power plants at reduced costs while maintaining high plant power generation efficiency. Chemical looping is a next generation advancement to oxy-combustion which would not require the significant investment in a cryogenic distillation type oxygen production plant. Instead of the energy-consuming oxygen plant, chemical looping uses a benign material to directly remove oxygen from the air and bring that oxygen into contact with the fuel. This "game changing" technology is the lowest cost-of-electricity technical approach that GE Power has identified to date for coal power with carbon capture. The technology has significantly lower capital costs compared to a conventional steam power plant with first generation carbon capture technologies. This new power plant concept is based on a hybrid combustion-gasification process utilizing high temperature chemical and thermal looping technology. In the air reactor, a solid oxygen carrier picks up oxygen from air through an oxidation reaction and leaves nitrogen behind. The hot oxygen-carrying solid carrier is then transported to a fuel reactor, where it releases oxygen. The released oxygen then converts the coal in the fuel reactor into combustion gases. The solid carrier is recycled back to the air reactor for regeneration completing the “chemical loop.” The regeneration step produces heat from which steam is produced for power generation while the process results in a concentrated carbon dioxide stream in which the carbon is captured for use or sequestration (CCUS). Limestone as a precursor for the oxygen carrier is abundant, benign, low cost, and is used in CFB and PC boilers for sulfur control. Challenges associated with this carrier include a complex reaction mechanism with possible side reactions leading to the release of SO 2 . The present project (DOE/NETL Cooperative Agreement No. DE-FE0025073) report focuses on coal-fired Limestone Chemical Looping Combustion (LCL-C™) processes that can produce a higher purity flue gas stream and achieve an improved overall performance that will meet the stated DOE goal of generating power from coal while achieving greater than 90% CO2 removal at less than 35% increase in the Levelized Cost of Electricity (LCOE). It builds on the concurrent and synergistic limestone-based chemical looping combustion (LCL-C™) and gasification (LCL-G™) projects with the Department of Energy, that were executed in parallel with the present project. In this report, the LCL-C™ experimental testing from the electrically-heated, once-through, 100 kW Pilot-Scale Test Facility (PSTF) is analysed and reviewed. The PSTF Oxidizer is a 50-foot tall, 100-mm diameter transport reactor, while the PSTF Reducer reactor is based upon a bubbling-bed design. The experimental data from designated test periods (denoted “Weeks”) are reviewed and discussed. The application of high sulfur release in the Reducer (with proper sulfur management) exceeded the LCL-CTM performance targets. Furthermore, the ilmenite blend came within 1 percentage point of meeting all of the performance targets.

01 COAL, LIGNITE, AND PEAT↗

High Temperature mechanically pumped fluid loop for space applications - working fluid selection

Mechanically pumped single-phase fluid loops are increasingly being used for heat rejection purposes in space applications. Examples of Earth orbiting missions using this technology include NSTS Shuttles (water and Freon-based loops) and the International Space Station (water and ammonia-based loops). For deep space missions, both the Mars Pathfinder (1996) and Mars Exploration Rover (2003) missions used mechanically pumped Freon-I 1 loops for their primary Heat Rejection Systems (HRS.) Mechanically pumped loops are particularly well suited for rejecting large amounts of waste heat from spacecraft and future missions incorporating components with extremely high thermal energy dissipation (e.g. radar instruments, Radioisotope-based power sources) are ideal candidates for their use. However, previous implementations of mechanically pumped loops were designed for moderate temperatures (below 6OOC) and, thus, would require relatively large radiators to reject high heat loads to space. Loops designed for a higher operating temperature would allow large amounts of heat to be rejected within the constraints of a mass efficient thermal control system.

high temperature↗

Testing of a Neon Loop Heat Pipe for Large Area Cryocooling

Cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks is required for future NASA missions. A cryogenic loop heat pipe (CLHP) can provide a closed-loop cooling system for this purpose and has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A neon CLHP was tested extensively in a thermal vacuum chamber using a cryopump as the heat sink to characterize its transient and steady performance and verify its ability to cool large areas or components. Tests conducted included loop cool-down from the ambient temperature, startup, power cycle, heat removal capability, loop capillary limit and recovery from a dry-out, low power operation, and long duration steady state operation. The neon CLHP demonstrated robust operation. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully by applying power to both the pump and evaporator without any pre-conditioning. It could adapt to changes in the pump power andor evaporator power, and reach a new steady state very quickly. The evaporator could remove heat loads between 0.25W and 4W. When the pump capillary limit was exceeded, the loop could resume its normal function by reducing the pump power. Steady state operations were demonstrated for up to 6 hours. The ability of the neon loop to cool large areas was therefore successfully verified.

Cryogenics↗

Automatic Event Detection in Search for Inter-Moss Loops in IRIS Si IV Slit-Jaw Images

The high-resolution capabilities of the Interface Region Imaging Spectrometer (IRIS) mission have allowed the exploration of the finer details of the solar magnetic structure from the chromosphere to the lower corona that have previously been unresolved. Of particular interest to us are the relatively short-lived, low-lying magnetic loops that have foot points in neighboring moss regions. These inter-moss loops have also appeared in several AIA pass bands, which are generally associated with temperatures that are at least an order of magnitude higher than that of the Si IV emission seen in the 1400 angstrom pass band of IRIS. While the emission lines seen in these pass bands can be associated with a range of temperatures, the simultaneous appearance of these loops in IRIS 1400 and AIA 171, 193, and 211 suggest that they are not in ionization equilibrium. To study these structures in detail, we have developed a series of algorithms to automatically detect signal brightening or events on a pixel-by-pixel basis and group them together as structures for each of the above data sets. These algorithms have successfully picked out all activity fitting certain adjustable criteria. The resulting groups of events are then statistically analyzed to determine which characteristics can be used to distinguish the inter-moss loops from all other structures. While a few characteristic histograms reveal that manually selected inter-moss loops lie outside the norm, a combination of several characteristics will need to be used to determine the statistical likelihood that a group of events be categorized automatically as a loop of interest. The goal of this project is to be able to automatically pick out inter-moss loops from an entire data set and calculate the characteristics that have previously been determined manually, such as length, intensity, and lifetime. We will discuss the algorithms, preliminary results, and current progress of automatic characterization.

loops↗

Automated Scenario Generation for Human-in-the-Loop Simulations

Automated Multi-Aircraft Control System scenario generation for Human-in-the-Loop (HITL) evaluations of air traffic management concepts is described. The objective is to replace the difficult manual process with the automated process for creating an initial (seed) scenario that serves as a starting point for manual adjustments for creating the Human-in-the-Loop scenario. Methods for analyzing and comparing the seed-scenario generated using the automated process and the Human-in-the-Loop-scenario derived from it to meet the experiment objectives are discussed. Results of comparison of input Human-in-the-Loop-scenario with the Multi-Aircraft Control System output are also presented. The main findings are: (1) many of the characteristics of the seed-scenario used for constructing the Human-in-the-Loop-scenario are preserved in the Human-in-the-Loop-scenario, (2) landing rate profile of the traffic generated by the Multi-Aircraft Control System (MACS) using the input scenario compares reasonably well with that intended in the input scenario, and (3) many of the desired characteristics of the Human-in-the-Loop-scenario can be achieved by further automation.

Automated Scenario Generation↗

Thermal and Well Flow Performance of Closed-Loop Geothermal in the Wattenberg Area: Preprint

Closed-loop geothermal systems provide an alternative to resource-constrained hydrothermal systems and stimulation-intensive enhanced geothermal systems. In this work, we apply the slender-body theory (SBT) model, to simulate the well flow and heat transfer performance of U-loop well designs drilled in the Wattenberg area of the Denver-Julesburg Basin. Three U-loop well patterns are investigated including a single, double, and multi-lateral design. The subsurface within area is characterized by deep, hot (> 200degreesC) igneous/metamorphic basement rock underlying multiple sedimentary formations. The lateral section(s) of the U-loop lies within a target depth of 6 km where temperatures are estimated to approach 300degreesC. As a base case, conduction-only heat transfer is investigated through simulations with the SBT model within U-loops with open-hole laterals that exchange heat directly with the hot dry rock using water as a working fluid. The utilization of supercritical CO2 as a heat transfer fluid is also considered. For each scenario, the system performance in terms of annual heat production and temperature profile over a 20-year project lifetime are assessed. Also, the levelized costs of heat and electricity (LCOH and LCOE) are determined using a top-down technoeconomic analysis model. The results show that the performance and cost optimized U-loop design is one having an injection-production well spacing of 1,000 meters with ten 50-meter-spaced laterals that traverse a subsurface system with a temperature gradient of 60degreesC/km. By injecting 20 degreesC-water at a rate of 60 kg/s through this loop, an average heat production of 19 MWth can be achieved, resulting in an LCOE and LCOH of $136/MWh and $1.53/GJ, respectively, over a 20-year project life.

closed-loop geothermal↗