Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LED Lighting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Fully Transparent GaN Homojunction Tunnel Junction-Enabled Cascaded Blue LEDs.

A sidewall activation process was optimized for buried magnesium-doped p-GaN layers yielding a significant reduction in tunnel junction-enabled light emitting diode (LED) forward voltage. This buried activation enabled the realization of cascaded blue LEDs with fully transparent GaN homojunction tunnel junctions. The initial optimization of buried p-GaN activation was performed on PN junctions grown by metal organic chemical vapor deposition (MOCVD) buried under hybrid tunnel junctions grown by MOCVD and molecular beam epitaxy. Next the activation process was implemented in cascaded blue LEDs emitting at 450 nm, which were enabled by fully transparent GaN homojunction tunnel junctions. The tunnel junction-enabled multi-active region blue LEDs were grown monolithically by MOCVD. This work demonstrates a state-of-the-art tunnel junction-enabled cascaded LED utilizing homojunction tunnel junctions which do not contain any heterojunction interface.

42 ENGINEERING↗

Dimming LED circuit augmenting DC/DC controller integrated circuit

Embodiments include systems, methods, and apparatuses for providing a dimming function in a single stage AC input light emitting diode (LED) driver with a controller that contains an on-chip error amplifier and an on-chip fixed reference voltage source coupled to a first input of the error amplifier. The controller controls a duty cycle of a switching transistor to cause a feedback voltage, applied to a first package input terminal, to match the reference voltage. To achieve a dimming function, a voltage across a current sense resistor in series with the LEDs is applied to a first input of a high gain differential amplifier, and a variable dimming control voltage is applied to a second input of the differential amplifier. The output of the differential amplifier is coupled to the first package input terminal. The differential amplifier input signals will be matched at the target LED current level.

Song, Zhengrong↗

Partial discharge transducer

A partial discharge (PD) transducer that includes a PD sensor configured to sense a PD event of an electrical system. At least one light emitting device (LED) is arranged in series with the PD sensor. The LED is configured to receive the electrical sensor signal from the PD sensor and to generate a light signal in response to the electrical sensor signal.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Partial discharge transducer

A partial discharge (PD) transducer that includes a PD sensor configured to sense a PD event of an electrical system. At least one light emitting device (LED) is arranged in series with the PD sensor. The LED is configured to receive the electrical sensor signal from the PD sensor and to generate a light signal in response to the electrical sensor signal.

Karin, Todd↗

Cesium Lead Halide Perovskite Nanocrystals Assembled in Metal–Organic Frameworks for Stable Blue Light Emitting Diodes

All inorganic cesium lead trihalide nanocrystals are promising light emitters for bright light emitting diodes (LEDs). Here we demonstrate CsPb(BrCl) 1.5 nanocrystals in metal-organic frameworks (MOF) thin films to achieve bright and stable blue LEDs. The lead metal nodes in the MOF thin film react with Cs-halide salts, resulting in 10~20 nm nanocrystals. This is revealed by X-ray scattering and transmission electron microscopy. Employing the CsPbX 3 - MOF thin films as emission layers, bright deep blue and sky-blue LEDs are demonstrated that emit at 452 nm and 476 nm respectively. The maximum external quantum efficiencies of these devices are 0.72% for deep blue LEDs and 5.6% for sky blue LEDs. More importantly, the device can maintain 50% of its original electroluminescence (T 50 ) for 2.23 hours when driving at 4.2V. Detailed optical spectroscopy and time-of-flight secondary ion mass spectroscopy suggest that the ion migration can be suppressed that maintains the emission brightness and spectra. Our study provides a new route for fabricating stable blue light emitting diodes with all-inorganic perovskite nanocrystals.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Effects of White Leds on Growth and Phytonutrients of Outredgeous Romaine Lettuce When Supplemented with Various Monochromatic Wavelengths

Growing plants in space will be an essential part of sustaining astronauts during long-range missions. To drive photosynthesis, light-emitting diodes (LEDs) are becoming superior because of their efficiency, longevity, small size, safety, and wavelength versatility. Isolating the effects of certain wavelengths on plant growth when combined with white light is attracting attention. To optimize crop production/quality in space, this study has aimed to configure novel light recipes for the Advanced Plant Habitat currently aboard the International Space Station (ISS). By using white light as a background to maintain normal growth, the addition of monochromatic wavelengths provides a clearer understanding of how each part of the visible spectrum affects plant growth. By growing Outredgeous lettuce under six treatments of White (W) LEDs, W + blue (B), W+ green (G), W + red (R), W + far red (FR), and RGB + FR LEDs with ratios similar to natural sunlight, this investigation has assessed differences in biomass, morphology, chlorophyll, and the synthesis of key phytonutrients. The potential for Outredgeous to produce anthocyanin, lutein, potassium, magnesium, and iron is paramount to maintaining astronaut health. The crop responses to each treatment have been evaluated and the optimal LED combination for both plant yield and nutrient content will be presented.

Food Production↗

Tuning of the magnetotransport properties of a spin-polarized 2D electron system using visible light

We report on the effects of visible light on the low temperature electronic properties of the spin-polarized two dimensional electron system (2DES) formed at the interfaces between LaAlO 3 , EuTiO 3 and (001) SrTiO 3 . A strong, persistent modulation of both longitudinal and transverse conductivity was obtained using light emitting diodes (LEDs) with emissions at different wavelengths in the visible spectrum range. In particular, Hall effect data show that visible light induces a non-volatile electron filling of bands with mainly 3 dxz,yz character, and at the same time an enhancement of the anomalous Hall effect associated to the magnetic properties of the system. Accordingly, a suppression of the weak-anti localization corrections to the magneto-conductance is found, which correlates with an enhancement of the spin-polarization and of the ferromagnetic character of 2DES. The results establish the LED-induced photo-doping as a viable route for the control of the ground state properties of artificial spin-polarized oxide 2DES.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Qualitative evaluation of a conformal velocity vector display for use at high angles-of-attack in fighter aircraft

A piloted simulation study was conducted to evaluate the utility of a display device designed to illustrate graphically and conformally the approximate location of a fighter aircraft's velocity vector. The display device consisted of two vertical rows of light emitting diodes (LED's) located toward the center of the cockpit instrument panel to each side of the control stick. The light strings provided a logical extension of the head up display (HUD) velocity vector symbol at flight path angles which exceeded the HUD field-of-view. Four test subjects flew a modified F/A-18 model with this display in an air-to-air engagement task against an equally capable opponent. Their responses to a questionnaire indicated that the conformal velocity vector information could not be used during the scenarios investigated due to the inability to visually track a target and view the lights simultaneously.

Jones, Denise R.↗

Optoelectronic Instrument Monitors pH in a Culture Medium

An optoelectronic instrument monitors the pH of an aqueous cell-culture medium in a perfused rotating-wall-vessel bioreactor. The instrument is designed to satisfy the following requirements: It should be able to measure the pH of the medium continuously with an accuracy of 0.1 in the range from 6.5 to 7.5. It should be noninvasive. Any material in contact with the culture medium should be sterilizable as well as nontoxic to the cells to be grown in the medium. The biofilm that inevitably grows on any surface in contact with the medium should not affect the accuracy of the pH measurement. It should be possible to obtain accurate measurements after only one calibration performed prior to a bioreactor cell run. The instrument should be small and lightweight. The instrument includes a quartz cuvette through which the culture medium flows as it is circulated through the bioreactor. The cuvette is sandwiched between light source on one side and a photodetector on the other side. The light source comprises a red and a green light-emitting diode (LED) that are repeatedly flashed in alternation with a cycle time of 5 s. The responses of the photodiode to the green and red LEDs are processed electronically to obtain a quantity proportional to the ratio between the amounts of green and red light transmitted through the medium.

Anderson, Melody M.↗

Improved Vertical Carrier Transport for Green III-Nitride LEDs Using ( In , Ga ) N Alloy Quantum Barriers

We report on experimental and simulation-based results using ( In , Ga ) N alloy quantum barriers in c -plane green light-emitting diode (LED) structures as a means to improve vertical carrier transport and reduce forward voltage ( V F ) . Three-dimensional device simulations that include random alloy fluctuations are used to understand carrier behavior in a disordered potential. The simulated current density–voltage ( J - V ) characteristics and modified electron-hole overlap | F mod | 2 indicate that increasing the indium fraction in the ( In , Ga ) N quantum barriers leads to a reduced polarization discontinuity at the interface between the quantum barrier and quantum well, thereby reducing V F and improving | F mod | 2 . Maps of electron and hole current through the device show a relatively homogenous distribution in the X Y plane for structures using Ga N quantum barriers; in contrast, preferential pathways for vertical transport are identified in structures with ( In , Ga ) N barriers as regions of high and low current. A positive correlation between hole (electron) current in the p -side ( n -side) barrier and indium fraction reveals that preferential pathways exist in regions of high indium content. Furthermore, a negative correlation between the strain ε z z and indium fraction shows that high indium content regions have reduced strain-induced piezoelectric polarization in the Z direction due to the mechanical constraint of the surrounding lower indium content regions. Experimentally, multiple quantum well green LEDs with ( In , Ga ) N quantum barriers exhibit lower V F and blue-shifted wavelengths relative to LEDs with Ga N quantum barriers, consistent with simulation data. These results can be used to inform heterostructure design of low V F , long-wavelength LEDs and provide important insight into the nature of carrier transport in III-nitride alloy materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cytometer on a Chip

A cytometer now under development exploits spatial sorting of sampled cells on a microarray chip followed by use of grating-coupled surface-plasmon-resonance imaging (GCSPRI) to detect the sorted cells. This cytometer on a chip is a prototype of contemplated future miniature cytometers that would be suitable for rapidly identifying pathogens and other cells of interest in both field and laboratory applications and that would be attractive as alternatives to conventional flow cytometers. The basic principle of operation of a conventional flow cytometer requires fluorescent labeling of sampled cells, stringent optical alignment of a laser beam with a narrow orifice, and flow of the cells through the orifice, which is subject to clogging. In contrast, the principle of operation of the present cytometer on a chip does not require fluorescent labeling of cells, stringent optical alignment, or flow through a narrow orifice. The basic principle of operation of the cytometer on a chip also reduces the complexity, mass, and power of the associated laser and detection systems, relative to those needed in conventional flow cytometry. Instead of making cells flow in single file through a narrow flow orifice for sequential interrogation as in conventional flow cytometry, a liquid containing suspended sampled cells is made to flow over the front surface of a microarray chip on which there are many capture spots. Each capture spot is coated with a thin (.50-nm) layer of gold that is, in turn, coated with antibodies that bind to cell-surface molecules characteristic of the cell species of interest. The multiplicity of capture spots makes it possible to perform rapid, massively parallel analysis of a large cell population. The binding of cells to each capture spot gives rise to a minute change in the index of refraction at the surface of the chip. This change in the index of refraction is what is sensed in GCSPRI, as described briefly below. The identities of the various species in a sample of cells is spatially encoded in the chip by the pattern of capture spots. The number of cells of a particular species is determined from the magnitude of the GCSPRI signal from that spot. GCSPRI as used here can be summarized as follows: The cytometer chip is fabricated with a diffraction grating on its front surface. The chip is illuminated with a light emitting diode (LED) from the front. By proper choice of grating parameters and of the wavelength and the angle of incidence of a laser beam, laser light can be made to be coupled into an electromagnetic mode that resonates with surface plasmons and thus couples light into surface plasmons. Coupling of light into a surface plasmon at a given location reduces the amount of incident light reflected from that location. A change in the index of refraction at the surface of a capture spot gives rise to a change in the resonance condition. Depending on the specific design, the change in the index of refraction could manifest itself as a brightening or darkening, a change in the wavelength needed to excite the plasmon at a given angle of incidence, or a change in the angle of incidence needed to excite the plasmon at a given wavelength. Whereas a multiwavelength laser system with multichannel detection would be needed to detect multiple species in conventional flow cytometry, it suffices to use an LED and a single detector channel in the GCSPRI approach: this contributes significantly to reductions in cost, complexity, size, mass, and power. GCSPRI cytometer chips could be made of plastic and could be mass-produced cheaply by use of molding and other methods adopted from the manufacture of digital video disks. These methods are amenable to a high degree of miniaturization: such additional features as fluidic channels, reaction chambers, and fluid-coupling ports could readily be incorporated into the chips, without incurring substantial additional costs.

Fernandez, Salvador M.↗

Cytometer on a Chip

A cytometer now under development exploits spatial sorting of sampled cells on a microarray chip followed by use of grating-coupled surface-plasmon-resonance imaging (GCSPRI) to detect the sorted cells. This cytometer on a chip is a prototype of contemplated future miniature cytometers that would be suitable for rapidly identifying pathogens and other cells of interest in both field and laboratory applications and that would be attractive as alternatives to conventional flow cytometers. The basic principle of operation of a conventional flow cytometer requires fluorescent labeling of sampled cells, stringent optical alignment of a laser beam with a narrow orifice, and flow of the cells through the orifice, which is subject to clogging. In contrast, the principle of operation of the present cytometer on a chip does not require fluorescent labeling of cells, stringent optical alignment, or flow through a narrow orifice. The basic principle of operation of the cytometer on a chip also reduces the complexity, mass, and power of the associated laser and detection systems, relative to those needed in conventional flow cytometry. Instead of making cells flow in single file through a narrow flow orifice for sequential interrogation as in conventional flow cytometry, a liquid containing suspended sampled cells is made to flow over the front surface of a microarray chip on which there are many capture spots. Each capture spot is coated with a thin (approximately 50-nm) layer of gold that is, in turn, coated with antibodies that bind to cell-surface molecules characteristic of one the cell species of interest. The multiplicity of capture spots makes it possible to perform rapid, massively parallel analysis of a large cell population. The binding of cells to each capture spot gives rise to a minute change in the index of refraction at the surface of the chip. This change in the index of refraction is what is sensed in GCSPRI, as described briefly below. The identities of the various species in a sample of cells is spatially encoded in the chip by the pattern of capture spots. The number of cells of a particular species is determined from the magnitude of the GCSPRI signal from that spot. GCSPRI as used here can be summarized as follows: The cytometer chip is fabricated with a diffraction grating on its front surface. The chip is illuminated with a light emitting diode (LED) from the front. By proper choice of grating parameters and of the wavelength and the angle of incidence of a laser beam, laser light can be made to be coupled into an electromagnetic mode that resonates with surface plasmons and thus couples light into surface plasmons. Coupling of light into a surface plasmon at a given location reduces the amount of incident light reflected from that location. A change in the index of refraction at the surface of a capture spot gives rise to a change in the resonance condition. Depending on the specific design, the change in the index of refraction could manifest itself as a brightening or darkening, a change in the wavelength needed to excite the plasmon at a given angle of incidence, or a change in the angle of incidence needed to excite the plasmon at a given wavelength. Whereas a multiwavelength laser system with multichannel detection would be needed to detect multiple species in conventional flow cytometry, it suffices to use an LED and a single detector channel in the GCSPRI approach: this contributes significantly to reductions in cost, complexity, size, mass, and power. GCSPRI cytometer chips could be made of plastic and could be mass-produced cheaply by use of molding and other methods adopted from the manufacture of digital video disks. These methods are amenable to a high degree of miniaturization: such additional features as fluidic channels, reaction chambers, and fluid-coupling ports could readily be incorporated into the chips, without incurring substantial additional costs.

Fernandez, Salvador M.↗

Using Light to Treat Mucositis and Help Wounds Heal

A continuing program of research and development is focusing on the use of controlled illumination by light-emitting diodes (LEDs) to treat mucositis and to accelerate healing of wounds. The basic idea is to illuminate the affected area of a patient with light of an intensity, duration, and wavelength (or combination of wavelengths) chosen to produce a therapeutic effect while generating only a minimal amount of heat. This method of treatment was originally intended for treating the mucositis that is a common complication of chemotherapy and radiation therapy for cancer. It is now also under consideration as a means to accelerate the healing of wounds and possibly also to treat exposure to chemical and radioactive warfare agents. Radiation therapy and many chemotherapeutic drugs often damage the mucosal linings of the mouth and gastrointestinal tract, leading to mouth ulcers (oral mucositis), nausea, and diarrhea. Hyperbaric-oxygen therapy is currently the standard of care for ischemic, hypoxic, infected, and otherwise slowlyhealing problem wounds, including those of oral mucositis. Hyperbaric-oxygen therapy increases such cellular activities as collagen production and angiogenesis, leading to an increased rate of healing. Biostimulation by use of laser light has also been found to be effective in treating mucositis. For hyperbaricoxygen treatment, a patient must remain inside a hyperbaric chamber for an extended time. Laser treatment is limited by laser-wavelength capabilities and by narrowness of laser beams, and usually entails the generation of significant amounts of heat.

Ignatius, Robert W.↗

In situ estimation of ice crystal properties at the South Pole using LED calibration data from the IceCube Neutrino Observatory

The IceCube Neutrino Observatory instruments about 1 km 3 of deep, glacial ice at the geographic South Pole. It uses 5160 photomultipliers to detect Cherenkov light emitted by charged relativistic particles. An unexpected light propagation effect observed by the experiment is an anisotropic attenuation, which is aligned with the local flow direction of the ice. We examine birefringent light propagation through the polycrystalline ice microstructure as a possible explanation for this effect. The predictions of a first-principles model developed for this purpose, in particular curved light trajectories resulting from asymmetric diffusion, provide a qualitatively good match to the main features of the data. This in turn allows us to deduce ice crystal properties. Since the wavelength of the detected light is short compared to the crystal size, these crystal properties include not only the crystal orientation fabric, but also the average crystal size and shape, as a function of depth. By adding small empirical corrections to this first-principles model, a quantitatively accurate description of the optical properties of the IceCube glacial ice is obtained. In this paper, we present the experimental signature of ice optical anisotropy observed in IceCube light-emitting diode (LED) calibration data, the theory and parameterization of the birefringence effect, the fitting procedures of these parameterizations to experimental data, and the inferred crystal properties.

54 ENVIRONMENTAL SCIENCES↗

GaN/InGaN Blue Light-Emitting Diodes on Polycrystalline Molybdenum Metal Foils by Ion Beam-Assisted Deposition

Light-emitting diode (LED) arrays fabricated on a polycrystalline metal substrate are demonstrated using a novel technique that enables the growth of epitaxial metal-organic chemical vapor deposition (MOCVD) GaN layers on non-single-crystal substrates. Epitaxial GaN is deposited directly on metal foil using an intermediate ion beam-assisted deposition (IBAD) aligned layer. For a single 170 μm-diameter LED on the metal foil, electroluminescence (EL) spectrum shows a peak wavelength of ≈452 nm and a full width at half maximum (FWHM) of ≈24 nm. The current–voltage (I –V ) characteristics show a turn-on voltage of 3.7 V, a series resistance of 10 Ω. LEDs on metal show a relative external quantum efficiency (EQE) that is roughly 3× lower than that of similar LEDs fabricated on a sapphire substrate. Finally, InGaN LEDs on large-area non-single-crystal substrates such as metal foils enable large-area manufacturing, reducing production cost, and opening the door for new applications in lighting and displays.

36 MATERIALS SCIENCE↗

NASA's Contributions to Vertical Farming

NASA and other space agencies have an interest in using plants for human life support in space. The plants could provide food and O2 for the humans, while removing CO2 and helping purify wastewater. Studies to date have shown that a wide range of crops can be grown in controlled environment conditions envisioned for space. These systems will be volume and power constrained and will require recycling of water and nutrients. Light is a critical factor both for crop productivity and system power costs, and recent improvements in LEDs make them a preferred lighting option for space. NASA funded research helped test LEDs for plant lighting beginning in1990 and their continued development for the next 15 years. The explore volume efficiency, concepts such as vertically stacked hydroponic systems and light banks were tested in NASA’s Biomass Production Chamber at Kennedy Space Center, FL, US from 1988 through 2000. This was perhaps one of the first operational vertical farms. Findings from these and related tests around the world date suggest that with ~30-40 mol m-2 day-1 of photosynthetically active radiation, about 20-25 m2 of crops could supply the O2 for one human, while about 50 m2 would be required for food (dietary calories).

Raymond M Wheeler↗

Reference Interferometer Using a Semiconductor Laser/LED Reference Source in a Cryogenic Fourier-Transform Spectrometer

A combination of a single mode AlGaAs laser diode and broadband LED was used in a Michelson interferometer to provide reference signals in a Fourier transform spectrometer, the Composite Infrared Spectrometer, on the Cassini mission to Saturn. The narrowband light from the laser produced continuous fringes throughout the travel of the interferometer, which were used to control the velocity of the scan mechanism and to trigger data sampling. The broadband light from the LED produced a burst of fringes at zero path difference, which was used as a fixed position reference. The system, including the sources, the interferometer, and the detectors, was designed to work both at room temperature and instrument operating temperature of 170 Kelvin. One major challenge that was overcome was preservation, from room temperature to 170 K, of alignment sufficient for high modulation of fringes from the broadband source. Another was the shift of the source spectra about 30 nm toward shorter wavelengths upon cooldown.

Martino, Anthony J.↗