Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inverter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Empirical Evaluation of GPS Clock Accuracy for Isochronous Droop-Based Inverters: Preprint

Grid-forming inverters rely upon an internal reference to regulate the grid’s voltage and frequency. Without a reliable reference, issues such as loss of synchronism, frequency instability, and unequal power sharing can occur. One proposed internal phase reference for grid-forming inverters is generated by the controller’s clock, but this is affected by nonidealities in the crystal oscillator leading to time drift in the phase reference. To improve the controller’s clock accuracy, the Global Positioning System (GPS) can be used to calibrate the internal clock. Previously, GPS-based clock calibration was explored theoretically and various methods were developed for mitigating frequency/phase drift at the power system level. This paper experimentally validates the direct performance of GPS time-calibration at the controller level and justifies its use in maintaining an accurate phase reference for droop-based grid-forming inverters.

clock drift↗

Inverters: A Pivotal Role in PV Generated Electricity

This presentation discusses the pivotal role inverters play in PV generated electricity. Topics include: the inverter as the center of the system--increasingly becoming the brain, with more features and capabilities (hybrid systems, safety, islanding, monitoring, etc.); increasing inverter-based generated electricity associated with many renewable energy sources; increased dependence for grid support and forming capability; communication within the grid and security increasingly required; increasing complexity leads to more chances to fail; as in most PV segments, there is cost reduction pressure, which makes it more challenging to keep the reliability high.

ENGINEERING,SOLAR ENERGY↗

Real-Time Testbed for Studying Cyberattacks and Defense in DER-integrated Smart Inverter Systems

In this paper, we propose a Hardware-in-the-Loop (HIL) simulation testbed suitable for the implementation and testing of realistic cyberattacks on grid-tied smart inverter systems integrated with Distributed Energy Resources (DER) that use the Distributed Network Protocol-3 (DNP3) protocol for communications between grid components. Specifically, our testbed combines a Real-Time Digital Simulator (RTDS) NovaCor device, outfitted with GNETx2 network interface cards, a gridtied DER topology implemented via the RTDS software package RSCAD, and a custom virtual network that emulates a man in the middle attacker. The Man-in-the-Middle (MITM) attacker captures DNP3 traffic and falsifies telemetry data in DNP3 packets to trigger unwarranted commands from a DNP3 controller that exploit smart inverter grid support functions. We choose DNP3 and implement grid support functions according to the IEEE Std. 1547-2018 mandated for the interconnection and interoperability of DER power systems with associated power components. Furthermore, we develop a protocol payload agnostic attack detection framework that leverages the round-trip time (RTT) anomalies between DNP3 requests and responses and can detect the presence of attacks without having to analyze the payload’s contents, while balancing trade-offs between false alarm counts, missed detections, and time to detection. To facilitate further research, we publicly release benign and attack network traffic exchanged between various sensors, controllers, and actuators in our grid-tied inverter testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber Threat Landscape and Engineering Mitigations for Grid Forming Inverters

This talk will cover the cyber threat landscape and engineering mitigations for grid forming (GFM) inverters. It will discuss the penetration of inverter-based resources (IBRs) in the United States and expected growth. It will then discuss the threat landscape for IBRs based on current and expected penetration. Real-world examples of cyber incidents affecting IBRs will be presented, concluding with an introduction to Cyber-Informed Engineering (CIE) and a guide on applying it to GFM inverters.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Stability Analysis of Power Systems with High Penetration of State-of-the-Art Inverter Technologies

With the increasing level of inverter-based resources (IBRs) in modern power systems, this paper presents a small-signal stability analysis for power systems comprising synchronous generators (SGs) and IBRs. Four types of inverter controls are considered: two grid-following (GFL) controls, with or without grid support functions; droop-based grid-forming (GFM) controls; and virtual oscillator control-based GFM. We also analyze the impact of STATCOM and synchronous condensers on system stability to assess their role in the energy mix transition. With the small-signal dynamic behavior of the major technologies modeled, this paper provides stringent stability assessments using the IEEE 39-bus benchmark system modified to simulate future power systems. The exhaustive test cases allow for (a) assessing the impacts of different types and controls of generation and supplementary grid assets, as well as system inertia and line impedance on grid stability, and (b) elucidating pathways for the stabilization of IBR-dominated power systems. The analysis also indicates that future power systems can be stabilized with only a fraction of the total generation as voltage sources without SGs or significant system inertia if they are well distributed. This study provides insights into future power system operations with a high level of IBRs that can also be used for planning and operation studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Masking of photovoltaic system performance problems by inverter clipping and other design and operational practices

We describe how performance problems can be “masked,” or not readily evident by several causes: by photovoltaic (PV) system configuration (such as the size of the PV array capacity relative to the size of the inverter and the resultant clipped operating mode); by instrumentation design, installation, and maintenance (such as a misaligned or dirty pyranometer); by contract clauses (when operational availability is transformed to contractual availability, which excludes many factors); and by identified management and operational practices (such as reporting on a portfolio of plants rather than individually). A simple method based on a duration curve is introduced to overcome shortcomings of Performance Ratio based on nameplate capacity and Performance Index based on hourly simulation when quantifying masking effects, and inverter clipping and pyranometer soiling are presented as two examples of the new method. With a better understanding of the non-transparency of masking issues, stakeholders can better interpret performance data and deliver improved AC and DC plant conditions through PV system operation and maintenance (O&M) for improved performance, reduced O&M costs, and a more consistently delivered, and reduced, levelized cost of energy (LCOE).

14 SOLAR ENERGY↗

Experimental Setup and Learning-Based AI Model for Developing Accurate PV Inverter Models [Slides]

The integration of power electronics-based interfaces presents challenges due to the absence of detailed models and the high computational complexity. Generic models used in system studies lack accuracy in capturing converter dynamics. This paper proposes a data-driven approach developed from experimental setup data. This approach enhances accuracy in photovoltaic inverter modeling. We used two types of PV inverters in the experiment. The recorded experimental data undergo processing through a machine learning model. Results from the model trained through machine learning is also presented.

14 SOLAR ENERGY↗

Out-of-time-ordered-correlators for the pure inverted quartic oscillator: classical chaos meets quantum stability

Out-of-time-ordered-correlators (OTOCs) have been suggested as a means to diagnose chaotic behavior in quantum mechanical systems. Recently, it was found that OTOCs display exponential growth for the inverted quantum harmonic oscillator, mirroring the fact that this system is classically and quantum mechanically unstable. In this work, I study OTOCs for the inverted anharmonic (pure quartic) oscillator in quantum mechanics, finding only oscillatory behavior despite the classically unstable nature of the system. For higher temperature, OTOCs seem to exhibit saturation consistent with a value of –2< x 2 > T < p 2 > T at late times. I provide analytic evidence from the spectral zeta-function and the WKB method as well as direct numerical solutions of the Schrödinger equation that the inverted quartic oscillator possesses a real and positive energy eigenspectrum, and normalizable wave-functions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Solvent and Temperature Effects on Photoinduced Proton-Coupled Electron Transfer in the Marcus Inverted Region

Concerted proton-coupled electron transfer (PCET) in the Marcus inverted region was recently demonstrated. Understanding the requirements for such reactivity is fundamentally important and holds promise as a design principle for solar energy conversion systems. Herein, we investigate the solvent polarity and temperature dependence of photoinduced proton-coupled charge separation (CS) and charge recombination (CR) in anthracene–phenol–pyridine triads: 1 (10-(4-hydroxy-3-(4-methylpyridin-2-yl)benzyl)anthracene-9-carbonitrile) and 2 (10-(4-hydroxy-3-(4-methoxypyridin-2-yl)benzyl)anthracene-9-carbonitrile). Both the CS and CR rate constants increased with increasing polarity in acetonitrile:n-butyronitrile mixtures. The kinetics were semi-quantitatively analyzed where changes in dielectric and refractive index, and thus consequently changes in driving force (–ΔG°) and reorganization energy (λ), were accounted for. The results were further validated by fitting the temperature dependence, from 180 to 298 K, in n-butyronitrile. The analyses support previous computational work where transitions to proton vibrational excited states dominate the CR reaction with a distinct activation free energy (ΔG* CR ~ 140 meV). However, the solvent continuum model fails to accurately describe the changes in ΔG° and λ with temperature via changes in dielectric constant and refractive index. Satisfactory modeling was obtained using the results of a molecular solvent model, which predicts that λ decreases with temperature, opposite to that of the continuum model. To further assess the solvent polarity control in the inverted region, the reactions were studied in toluene. Nonpolar solvents decrease both ΔG° CR and λ, slowing CR into the nanosecond time regime for 2 in toluene at 298 K. This demonstrates how PCET in the inverted region may be controlled to potentially use proton-coupled CS states for efficient solar fuel production and photoredox catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoscale Amorphization of Poly(Triarylamine) for Efficient and Stable Inverted Perovskite Photovoltaics

Perovskite solar modules require hole-selective layers that combine efficient charge extraction, interfacial uniformity and scalable processing. Poly(triarylamine) (PTAA) is widely used in high-performance inverted perovskite photovoltaics, but its nanoscale crystallization and aggregation on indium tin oxide can disrupt film continuity, increase interfacial recombination and limit module stability. Here we show that 4-fluorobenzylphosphonic acid (4FBPA) modifies the surface of indium tin oxide to induce nanoscale amorphization of PTAA, forming a uniform sub-10-nm hole-selective layer. The molecule binds to indium tin oxide through a dehydration reaction, tunes the work function and surface free energy of the photoanode, and improves energy-level alignment with PTAA. The resulting amorphous PTAA film shows enhanced conductivity and hole extraction, suppresses non-radiative recombination at the buried interface and promotes more uniform perovskite growth. Inverted perovskite solar cells reach a power conversion efficiency of 26.63%, while blade-coated modules achieve a certified quasi-steady-state efficiency of 23.01%. The modules retain 95.9% of their initial efficiency after 2,600 hours of maximum-power-point operation under 1-sun illumination at 65 +- 5 degrees C in nitrogen. These results identify nanoscale amorphization of polymeric hole-selective layers as a route to efficient and stable inverted perovskite photovoltaics.

14 SOLAR ENERGY↗

GaN‐based split phase transformer‐less PV inverter with auxiliary ZVT circuit

This paper explores performance enhancement of the common ground dynamic dc‐link (CGDL) inverter for single phase photovoltaic (PV) applications by a combination of gallium nitride (GaN) devices, split phase topology, coupled inductors, and zero voltage transition (ZVT) scheme. The CGDL inverter has the inherent advantage of minimised dc‐link capacitance and negligible leakage current due to the common ground configuration, but its reported efficiency was usually lower because of the higher dc‐link voltage used for the reduction of decoupling capacitance to a great extent. To solve the efficiency problem, in this study, a soft switching circuit is proposed for the first stage, while a coupled inductor integrated magnetics is incorporated in the second stage to reduce inductor loss, volume, and cost. Both of these topological improvements combined with the use of GaN devices facilitate in achieving high efficiency without compromising converter power density. Extensive experimental results are provided from a GaN based 1 kVA hardware prototype to demonstrate the superior performance of the CGDL inverter attaining a peak efficiency of 98.7% and a California Energy Commission efficiency of 98.5% at 75/50 kHz switching frequency.

Xia, Yinglai↗

Classification of (2 + 1) D invertible fermionic topological phases with symmetry

Here we provide a classification of invertible topological phases of interacting fermions with symmetry in two spatial dimensions for general fermionic symmetry groups G f and general values of the chiral central charge c - . Here G f is a central extension of a bosonic symmetry group G b by fermion parity, (-1) F , specified by a second cohomology class [ω 2 ]∈ $\mathscr{H}^2$(Gb,$\mathbb{Z}_2$). Our approach proceeds by gauging fermion parity and classifying the resulting G b symmetry-enriched topological orders while keeping track of certain additional data and constraints. We perform this analysis through two perspectives, using G-crossed braided tensor categories and Spin(2c - ) 1 Chern-Simons theory coupled to a background G gauge field. These results give a way to characterize and classify invertible fermionic topological phases in terms of a concrete set of data and consistency equations, which is more physically transparent and computationally simpler than the more abstract methods using cobordism theory and spectral sequences. Our results also generalize and provide a different approach to the recent classification of fermionic symmetry-protected topological phases by Wang and Gu, which have chiral central charge c - = 0. We show how the tenfold way classification of topological insulators and superconductors fits into our scheme, along with general nonperturbative constraints due to certain choices of c - and G f . Mathematically, our results also suggest an explicit general parametrization of deformation classes of (2 + 1)D invertible topological quantum field theories with G f symmetry.

36 MATERIALS SCIENCE↗

Comprehensive AI-based System for Control, Sensor Estimation, and Fault Detection of Cascaded Multilevel Inverters

In this paper, an Artificial Intelligence-based (AI) system is proposed for an 11-level cascaded H-bridge multilevel inverter (MLI) with the aims of harmonic suppression and reliability enhancement. The system consists of three seamlessly integrated Neural Networks (NNs). First, a multilayer perceptron is used to generalize the optimal switching angles for selective harmonic elimination under non-equal DC voltages. Next, an autoencoder NN estimates the voltage sensor readings to address potential drifting. Finally, a perceptron NN detects inverter faults based solely on the output voltage of the MLI. Simulation scenarios were evaluated, and the results show that the proposed system provides a comprehensive solution for the robust operation of the MLI. The proposed solution is capable of minimizing the targeted harmonics orders with minimal impact on the fundamental voltage, even when the voltage sensor drifts. Furthermore, the inverter under fault conditions was successfully identified.

Rezende da Costa Reis Kimpara, Renata↗

Energy-Storage Fed Smart Inverters for Mitigation of Voltage Fluctuations in Islanded Microgrids

The continuous integration of intermittent low-carbon energy resources makes islanded microgrids vulnerable to voltage fluctuations. Besides, different dynamic response of synchronous-based and inverter-based distributed generation (DG) units can result in an instantaneous power imbalance between supply and demand during transients. As a result, the ac-bus voltage of microgrid starts oscillating which might have severe consequences such as blackouts. This paper modifies the conventional control scheme of battery energy storage systems (BESSs) to participate in improving the dynamic behavior of islanded microgrids by mitigating the voltage fluctuations. A piecewise linear-elliptic (PLE) droop is proposed and employed in BESS to achieve an enhanced voltage profile by injecting/absorbing reactive power during transients. In this way, the conventional inverter implemented in BESS turns into a smart inverter to cope with fast transients. Using the proposed approach in this paper, any linear droop curve with a specified coefficient can be replaced by a PLE droop curve. Compared with linear droop, an enhanced dynamic response is achieved by utilizing the proposed PLE droop. Case study results are presented using PSCAD/EMTDC to demonstrate the superiority of the proposed approach in improving the dynamic behavior of islanded microgrids.

Pilehvar, Mohsen S.↗

Smart Inverters for Seamless Reconnection of Isolated Residential Microgrids to Utility Grid

This paper proposes an approach to achieve seamless reconnection of isolated residential microgrids to utility grid. Any abnormal condition on the grid side results in isolating the residential microgrid from utility grid, and giving the full responsibility of supplying household loads to local distributed generation (DG) units. However, after resolving the abnormal condition on the grid side, the residential microgrid needs to seamlessly reconnect to the main grid. To this end, a seamless transition algorithm is presented which monitors the system condition in real time, and coordinates the operation of all inverter-based DG units in residential microgrid before reconnection to the main grid. A modified control scheme is proposed for single-phase inverters which turns them into smart inverters enable to interact with seamless transition algorithm. The proposed approach synchronizes each phase voltage with its respective grid-side voltage in order to seamlessly reconnect the residential microgrid to the main grid. Case study results are carried out in PSCAD/EMTDC environment to verify the validity of proposed method.

Pilehvar, Mohsen S.↗

Data-Driven Distribution System Coordinated PV Inverter Control Using Deep Reinforcement Learning

The deployment of distributed solar photovoltaic (PV) systems has increased consistently over the past decades. High penetrations of PVs could cause a series of adverse grid impacts, such as voltage violations. The recent development of smart inverter technologies rises the incentives of developing PV control solutions that regulate the inverter output power and seeking the optimization on system operational objectives. This paper proposes a data-driven control solution based on deep reinforcement learning (DRL) to optimize PV inverters for voltage regulation. The proposed solution can minimize PV real power curtailment while maintaining network voltage at an acceptable range. Comparison results between the proposed DRL control algorithms with deep deterministic policy gradient (DDPG) and volt-var control on a real feeder in west Colorado highlight the advantage of the proposed framework in controlling the system voltage while minimizing the PV real power curtailment.

deep reinforcement learning↗

High-Energy Density Capacitors for Electric Vehicle Traction Inverters

DC bus capacitors take up substantial space in a traction inverter, limiting the traction drive power density. Thus, several commercial capacitor technologies, under consideration for use as DC bus capacitors for electric vehicle traction inverters, were reviewed for their ability to optimize the volume of traction inverters and are evaluated in this paper. Three promising capacitor technologies--film, ceramic, and PLZT have been selected for detailed experimental characterization. Experimental results for equivalent series resistance, equivalent series inductance, and effective capacitance with respect to DC bias voltage for various operating frequencies and temperatures are presented. The results reveal the superiority of the PLZT capacitor in terms of power density, current conduction capability, and redundancy.

Chowdhury, Shajjad↗