Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Injection data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Evaluating the Feasibility of Measuring and Analyzing Strain Caused by Changes in Barometric Pressure in the Vadose Zone

Changes in barometric pressure propagate into the subsurface where they can affect water level measurements in wells and cause vertical strain. Previous strain sensors were developed to measure vertical strain, but they were limited to measurements at a single depth, making it difficult to evaluate strains from a migrating pressure wave. Technology known as Coherence-length-gated Microwave Photonics Interferometry (CMPI) uses optical fiber sensors to measure strain at multiple locations. It has the potential to detect strain caused by variations in barometric pressure at multiple depths in the subsurface. The goal of this study is to evaluate the feasibility of using this technology to record the changes in vertical strain in the vadose zone from small fluctuations in air pressure. Propagation of these air pressure fluctuations is affected by hydrogeological properties such as water content and permeability. A second goal of this study is to evaluate how these properties affect the air pressure distribution, strain, and gas-phase diffusivity with a long-term goal of using strain to monitor the vadose zone. The focus of this study is on a suite of laboratory experiments that used a sand-filled column with an open head space. The CMPI fiber was packaged and embedded along the axis of the column to measure the strain at multiple locations while air pressure transducers were installed through the wall of the column. Small periodic fluctuations in air pressure, similar to barometric pressure fluctuations, were created in the head space of the column using an audio driven speaker driven at 4 Hz using a sinusoidal signal created by a function generator. Then, the fluctuations propagated along the column where they were measured by the transducers and recorded as functions of time. Initial tests were conducted using dry sand, but then additional tests were conducted after injecting water into the column, which changed the hydrologic and mechanical properties. Another experiment was conducted after creating a thin barrier to air flow, which was designed to simulate a thin layer of saturated ground during rainfall. A final experiment was conducted by changing the grain size of the material to create a heterogeneity in the upper half of the column. The suite of six experiments was conducted to highlight effects of variations in water content and heterogeneities on air pressure and vertical strain. Numerical simulations were also created to evaluate the laboratory data and to provide a baseline analysis for the results. The numerical simulations used the governing equations to linear poroelasticity and two-phase flow with boundary conditions representing the experiments. The conceptual model for strain caused by barometric pressure recognizes that a fluctuating barometric pressure causes fluctuations in the air pore pressure that decrease in amplitude and lag in time with increase depth. The pressure distribution results in two different loads that cause strain: 1.) a mechanical load as the barometric pressure acts on the ground surface; and 2.) pressure loading in the pore space. The results show that the total vertical strain is a contribution of both of these loads, and this is the strain that was observed in the laboratory. The lab experiments show that both air pressure and strain vary as sinusoids that propagate with depth. The amplitude of the air pressure and strain decrease as a function of depth in all the conditions that were evaluate. For example, in the dry sand, the amplitude of the air pressure decreases from 25 Pa at the head space to 5 Pa at a depth of 70 cm, whereas the amplitude of the strain decreases from 0.15 to 0.06 µε over the same depth interval. In many cases the amplitudes decrease is approximately negative exponential functions of depth. When water was injected into the sand and the saturation increased, the amplitude of the air pressure increased in the partially saturated sand but decreased sharply to zero where the soil was saturated. The strain decreased with depth, but the transition from partially to fully saturated conditions had little effect on the strain profile, even though it had a major effect on the air pressure. This apparently is because strain is caused by variations in both water and air pressure. The fluctuating air pressure caused the water pressure to fluctuate, which caused strain throughout the column. Phase delay of the air pressure and the strain both increase as linear to bi-linear functions of depth. The phase delays indicate that pressure propagates at a velocity of 7 to 8 m/s in dry or partially saturated sand, but it drops by more than an order of magnitude in the vicinity of the capillary fringe. The phase delays indicate the strain propagates faster than the pressure. The data indicate that the strain propagates from 1.2 to more than 4x faster than the pressure. Switching from sand to silt in the column caused the velocity of the pressure to drop by roughly half for both pressures, but curiously, it had little effect on the velocity of the strain.

54 ENVIRONMENTAL SCIENCES↗

Development of an Integrated Multidiagnostic to Assess the High-Z Impurity Fluxes in the Metallic Environment of WEST Using IMAS

WEST is an actively cooled, long-pulse tokamak with nearly all plasma-facing components (PFC) made of tungsten. One of the aims of WEST is to study plasma operations with tungsten PFCs in preparation for long-pulse operations on high-Z divertor devices, such as ITER. For long-pulse operation, the high-Z impurity content and transport to the core plasma are critical concerns that require further measurement and interpretation to improve plasma performance and PFC durability. This work details the impurity influxes in WEST during a series of discharges in which the lower hybrid (LH) injected power was incrementally increased. An analysis has been performed of measurements collected from an array of edge diagnostics. Visible spectroscopy was utilized to measure the spectral radiances generated by fuel particles (D) and impurities (W, O, and C) at the divertor and at the antennas with a newly developed spectral peak-fitting tool used to analyze the data in WEST. The scrape-off layer (SOL) plasma conditions (n e and T e ) measured at the divertor target with flush Langmuir probes and near the outer mid-plane (OMP) using reciprocating Langmuir probes (RCPs) are used to evaluate the number of ionizations per photons (S/XB) coefficients required to estimate the impurity fluxes obtained with the collisional-radiative model ColRadPy. Here, the array of edge diagnostics discussed in this work, coupled with SOL plasma modeling tools, represents a multidiagnostic interpretative modeling workflow that will continue to be applied to upcoming experimental campaigns on the WEST experiment to assess high-Z impurity transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-Invasive Measurement of Pulsatile Intracranial Pressures Using Ultrasound

Early detection of elevated intracranial pressure (ICP) will aid clinical decision-making for head trauma, brain tumor and other cerebrovascular diseases. Conventional methods, however, require surgical procedures which take time and are accompanied by increased risk of infection. Accordingly we have developed and refined a new ultrasound device to measure skull movements which are known to occur in conjunction with altered ICP. The principle of this device is based upon pulse phase locked loop (PPLL), which enables us to detect changes in distance on the order of microns between an ultrasound transducer on one side of the skull and the opposite inner surface of the cranium. The present study was designed to verify this measurement technique in cadavera. Transcranial distance was increased in steps of 10 mmHg from zero to 50 mmHg by saline infusion into the lateral ventricle of two cadavera. In separate experiments, pulsations of ICP with the amplitudes of zero to 2 mmHg were generated by rhythmic injections of saline using a syringe. When the ICP was stepwise increased from zero to 50 mmHg, transcranial distance increased in proportion with the ICP increase (y=12 x - 76, r=0.938), where y is changes in transcranial distance in microns and x is ICP in mmHg. In the data recorded while ICP pulsations were generated, fast Fourier transform analysis demonstrated that cranial pulsations were clearly associated with ICP pulsations. The results indicate that changes in transcranial distance is linearly correlated with those in ICP, and also that the PPLL device has sufficient sensitivity to detect transcranial pulsations which occur in association with the cardiac cycle. By analyzing the magnitude of cranial pulsations, we may be able to estimate the pressure-volume index in the cranium. As a result, estimates of intracranial compliance may be possible by using the PPLL device. Further studies are necessary in normal subjects and patients.

Ueno, Toshiaki↗

Jet Noise Reduction by Microjets - A Parametric Study

The effect of injecting tiny secondary jets (microjets ) on the radiated noise from a subsonic primary jet is studied experimentally. The microjets are injected on to the primary jet near the nozzle exit with variable port geometry, working fluid and driving pressure. A clear noise reduction is observed that improves with increasing jet pressure. It is found that smaller diameter ports with higher driving pressure, but involving less thrust and mass fraction, can produce better noise reduction. A collection of data from the present as well as past experiments is examined in an attempt to correlate the noise reduction with the operating parameters. The results indicate that turbulent mixing noise reduction, as monitored by OASPL at a shallow angle, correlates with the ratio of jet to primary jet driving pressures normalized by the ratio of corresponding diameters (p d /pjD). With gaseous injection, the spectral amplitudes decrease at lower frequencies while an increase is noted at higher frequencies. It is apparent that this amplitude crossover is at least partly due to shock-associated noise from the underexpanded jets themselves. Such crossover is not seen with water injection since the flow in that case is incompressible and there is no shock-associated noise. Centerline velocity data show that larger noise reduction is accompanied by faster jet decay as well as significant reduction in turbulence intensities. While a physical understanding of the dependence of noise reduction on p d /pjD remains unclear, given this correlation, an analysis explains the observed dependence of the effect on various other parameters.

Zaman, K. B. M. Q.↗

Industry-Average Performance for Components and Initiating Events at U.S. Commercial Nuclear Power Plants: 2020 Update

This report documents the quantitative results of the current industry-average performance for components and initiating events (IEs) at U.S. commercial nuclear power plants (NPPs). It represents the third update of the original analysis in NUREG/CR-6928 with data through 2020. Continuous characterization and updating of current industry-average performance with the latest industry data available are important steps in maintaining up-to-date risk models. Typically, data from 1998–2002 were used in NUREG/CR-6928, data from 1998–2010 in the first update, data from 1998–2015 in the second update, and data from 2006–2020 in this update, although many IEs required longer periods for adequate characterization of frequencies in all these analyses. As with NUREG/CR-6928 and previous updates, four types of events are covered in this report: component unreliability (e.g., a pump that fails to start or fails to run), component or train unavailability resulting from test or maintenance outages, special event probabilities covering operational issues (e.g., pump restarts and injection valve re-openings during unplanned demands), and IE frequencies. Results (in the form of beta distributions for failure probabilities upon demand and gamma distributions for rates) are used as inputs to the U.S. Nuclear Regulatory Commission standardized plant analysis risk models covering U.S. commercial NPPs.

99 GENERAL AND MISCELLANEOUS↗

In‐mold rheology and automated process control for injection molding of recycled polypropylene

Abstract Manufacturing plastic parts with secondary feedstocks has risen to the forefront of importance in recent years. However, the variation in molecular weight and rheology of secondary feedstock can lead to inconsistent part quality. This work evaluates the effectiveness of a novel closed‐loop adaptive process control system that adjusts nozzle pressure in response to in‐mold pressure data. Five different recycled polypropylene blends, with a broad distribution of flow properties, were evaluated to determine the effectiveness of the control system at reducing processing variation. The experimental results show that the process control strategy reduced the variation within the mold, as seen by in‐mold pressure curves and calculated in‐mold viscosity values. Additionally, the parameters that control the automated process adjustments were investigated, showing the importance of optimization. The analysis of the correlation between in‐mold rheology and mechanical properties showed a slight variation in the mechanical properties and parts weight with a coefficient of variation of under 5%. Overall, the results demonstrate the ability of pressure‐controlled molding and automated viscosity adjustment to reduce the variability when molding a secondary feedstock. Highlights Pressure‐controlled injection molding of recycled polypropylene. Automated closed‐loop adaptive process control methodology. Methodology resulted in a reduction in pressure variation during molding. Changes in mechanical properties and in‐mold viscosity were investigated. Results show the potential of pressure‐controlled molding at reducing variation.

Krantz, Joshua↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Parameters Impacting Columnated Granular Soil Pneumatic Seal Performance

The ability of a column of loose granular soil to form a pneumatic seal was investigated by varying the diameter of the soil column, the effective column height, and the level of compaction in the soil. The soil column diameter was tested at three levels using pipes with inner diameters measuring 5.08, 10.16, and 15.24 centimeters (2, 4, and 6 inches). Soil was filled in each pipe to form 15, 30, and 45 centimeter (6, 12, and 18 inch) tall soil columns. Each diameter/height configuration was also tested at three levels of soil compaction, compared by calculating the bulk density of the soil with mass and volume measurements. GRC-1a simulant was used, with approximate low/medium/high bulk densities of 1.6, 1.75, and 1.9 g/cc achieved with a combination of vibration and tamping. The order of tests for a given column diameter was randomized and repeated three times. With the top of the soil open to atmosphere at room temperature, compressed air was injected through a small diffuser at the column base with several small downward-facing holes. The number and size of these holes was scaled such that a constant total inlet orifice area to column cross sectional area ratio was maintained for each column diameter. Inlet air pressure was slowly increased via a precision regulator to preserve quasi-static equilibrium in the soil column to minimize the impact of dynamics. Air pressure was increased all the way through the static and bubbling regimes until slugging or turbulent behavior was observed in the soil to ensure that the entire static regime had been captured during data collection. A three-factor, three-level analysis of variance (ANOVA) statistical analysis was performed on the resulting data to determine the extent to which each physical parameter impacted the soil column seal performance. It was concluded that there is statistically significant evidence that column height, and the interaction between column height and diameter impact soil seal performance. In all other cases there was insufficient data to identify a statistically significant causal relationship. Additionally, plots were generated comparing experimental data to the predictive formula developed by Ogino et al. for fluidized beds in 1993. Because this model was developed for industrial spouted fluidized beds, the accuracy of its output prior to fluidization in the static seal ‘edge case’ is unknown, especially considering in this application the working gas was diffused across the column base rather than being injected through a spout. Further, the fidelity of the model had not yet been tested with lunar soil simulants. Plotting the Ogino et al. model alongside test data allows for a more intuitive sense of the impact of test parameters on soil seal performance, as well as providing a quick means to further tune this predictive model for more accurate use with static seals across granular lunar soil simulants. The model provided by Ogino et al. was further tuned using test data to determine the degree to which a spouted bed model could be applied to a slightly modified set of testing conditions: lunar soil simulants and a more diffuse, homogeneous application of pneumatic pressure. A Matlab script was created to test different values for the leading coefficient and exponents in Ogino’s formula. The script swept preset ranges, then iterated with higher resolutions across narrower ranges to converge on the optimal value for each parameter. The resulting adjusted model was compared to the original, as well as test data with noticeable improvements across the entire test domain.

Jack Stewart↗

Ares I and Ares I-X Stage Separation Aerodynamic Testing

The aerodynamics of the Ares I crew launch vehicle (CLV) and Ares I-X flight test vehicle (FTV) during stage separation was characterized by testing 1%-scale models at the Arnold Engineering Development Center s (AEDC) von Karman Gas Dynamics Facility (VKF) Tunnel A at Mach numbers of 4.5 and 5.5. To fill a large matrix of data points in an efficient manner, an injection system supported the upper stage and a captive trajectory system (CTS) was utilized as a support system for the first stage located downstream of the upper stage. In an overall extremely successful test, this complex experimental setup associated with advanced postprocessing of the wind tunnel data has enabled the construction of a multi-dimensional aerodynamic database for the analysis and simulation of the critical phase of stage separation at high supersonic Mach numbers. Additionally, an extensive set of data from repeated wind tunnel runs was gathered purposefully to ensure that the experimental uncertainty would be accurately quantified in this type of flow where few historical data is available for comparison on this type of vehicle and where Reynolds-averaged Navier-Stokes (RANS) computational simulations remain far from being a reliable source of static aerodynamic data.

Pinier, Jeremy T.↗

Analyses of Injection-Coupled Combustion Instability from J-2X Gas Generator Development

During development of the gas generator for the liquid oxygen/liquid hydrogen propellant J-2X rocket engine, combustion instabilities were observed near the frequency of the first longitudinal acoustic mode of the hot gas combustion chamber duct. These instabilities were similar to intermediate-frequency or buzz-type instabilities as described in historical programs, except for several aspects: 1) the frequencies were low, in the realm of chug; 2) at times the instability oscillation amplitudes were quite large, with peak-to-peak amplitudes exceeding 50% of the mean chamber pressure along with the appearance of harmonics; 3) the chamber excitation was related to but not exactly at the first longitudinal combustion chamber acoustic mode; and 4) the injector provided mass flow rate oscillations induced by capacitance and inertance effects in the injector rather than by organ pipe resonances of the coaxial oxidizer posts. This type of combustion instability is referred to as "injection coupling" because one critical driving source of the instability is mass flow rate oscillations from the injector. However, the type of injection coupling observed here is different than observed in previous instances of buzz instability with coaxial injectors, because of the lower frequencies and lack of influence from the oxidizer post organ pipe resonances. Test data and preliminary analyses of the initial combustion instabilities were presented in several papers at the 5th Liquid Propulsion Subcommittee meeting. Since that time, additional hot-fire tests with several new hardware configurations have been conducted, and additional analyses have been completed. The analytical models described in previous papers have been updated to include the influences of new geometrical configurations, including a different oxidizer injector manifold configuration and a branch pipe in the hot gas duct that supplies gaseous helium during the start transient to pre-spin the turbine. In addition, the analysis methodology has been revisited to evaluate the potential influence of a combustion response as well as an injection response.

Hulka, James R.↗

DECOVALEX-2023: Task D Final Report

Task D of DECOVALEX-2023 is focused on the simulation of the coupled thermal hydraulic-mechanical (THM) behaviour in the full-scale engineered barrier system (EBS). The Horonobe EBS experiment is the demonstration of the full-scale EBS in the underground research laboratory (URL) (performed by JAEA in the Horonobe URL in Japan). Task D consisted of the three steps, a preliminary step (Step 0), simulation of the laboratory tests (Step 1) and simulation of the in-situ full-scale EBS experiment (Step 2). Since the Horonobe EBS experiment demonstrates the vertical emplacement option of the EBS, the experiment gallery is also backfilled with the backfill material. Therefore, interaction between the EBS and the backfill material can also be demonstrated, such as deformation (change of density) of the buffer material. The underground water in the Horonobe URL is saline. This fact adds chemical processes to THM behaviour. For example, mechanical properties (such as swelling pressure of the buffer material and backfill material) and hydraulic properties (such as permeability of the buffer material and backfill material) change depending on the water chemistry. Task D was therefore a challenging Task focused on not only the relatively simple THM behaviour but also complex THM behaviour including chemical processes. Six research teams (BGR, CAS, JAEA, KAERI, SNL and Taipower) participated the Task D. BGR, CAS, JAEA, KAERI and Taipower research teams selected a THM approach, while the SNL research team selected a TH approach. Step 1 involved the simulation of laboratory test results and was important to check the numerical codes developed by the research teams. Step 1 was divided into four sub steps. The simulation results through the Step 1 identified the parameters for simulation of the Step 2. Basic parameters of the materials (buffer material, backfill material, rock mass, concrete, sand) were provided by JAEA. Special parameters which research team needed were identified by back analysis of Step 1. Most notably the mechanical behaviour of swelling and displacement depended on the applied model (elastic model or elastoplastic model). Parameters such as Young’s modulus were found to need smaller values than characterised in the fundamental laboratory test results (Step 1-1, 1-2) for the elastic model. Although laboratory experiments are usually simple, test results contained some error. For example, if the saturation level is 100 % or higher, it should be considered an error. This situation was presented in the Step 1-3. A possible reason is that the buffer material is a mixture of bentonite and silica sand. When a specimen is cut to measure volume or weight, sand grains will affect the measurement data. In Step 2, boundary conditions such as temperature on the surface of the simulated overpack, heater power of the electrical heaters installed in the simulated overpack, injection pressure and inflow rate of the test water, were applied. The outer boundary conditions can be selected using measured data (injection pressure and inflow rate of the test water that is controlled by the injection systems installed in the sand layer around the buffer material and in the boundary between backfill material and concrete support). Since such measured data has some noise, research teams developed their own simplified boundary conditions. Inner boundary conditions can be selected using measured data as heater power and temperature on the surface of the simulated overpack. These data also contain some noise, so research teams developed their own simplified developed boundary conditions. Task D validated various approaches thorough the simulation of the in-situ full scale EBS system including backfill of the gallery: variations in the coupling processes (THM or THC), analysis codes, and boundary conditions. Temperature distribution in the buffer material was simulated well by all research teams. This means thermal behaviour is not sensitive to the simulation approaches. Although the water content distribution on the outside of the buffer material was well simulated by all research teams, the simulation results differ from the measured values inside the buffer material (at the centre and inside, near the simulated overpack). The buffer material is made from tap water, but in the in-situ experiment, saline groundwater infiltrates the buffer material. Therefore, the selection of the hydraulic parameters of the buffer material greatly affects the simulation results of the re saturation behaviour of the buffer material. In the Horonobe EBS experiment, measured values suitable for validating the simulation results were not obtained near the simulated overpack. When simulating the pressure and deformation of the buffer material, the measurement data is easily affected by the installation conditions of the measurement sensors, so verifying the measurement data itself remains an issue. Mechanical simulation results differ depending on whether they are considered as elastic or elastoplastic phenomena. The accuracy of measured in-situ data can be assessed by detailed analysis comparing sampling specimen analysis and measured data. The Horonobe EBS experiment is scheduled to be dismantled in the future (FY2026 and 2027). This detailed dismantling investigation will finally confirm the measured data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Prototype High-Voltage Pulsed Power Supply for Control of the ITER Shattered Pellet Injection System Flyer Plate Valve

A high-voltage pulsed power supply (HVPPS) has been designed, prototyped, and tested for driving an eddy current actuated propellant valve for the International Thermonuclear Experimental Reactor (ITER) disruption mitigation system. The high-voltage (HV) dc supply output voltage is software programmable, and the energy storage capacitor bank can be readily reconfigured as 200, 400, 600, and 800 μ F, enabling testing and optimization of both the valve drive and valve systems. Multiple system parameters are monitored before, during, and after each firing of the valve. The system parameters are both displayed and stored for further analysis. Control of the setup, firing sequence, and data collection is automated using a LabVIEW-based control program. The programmability and reconfigurability of this system collectively provide a flexible and robust platform for system refinement and optimization. In this article, a summary of the system will be provided including operational sequences, HV switching and associated triggering methods and circuits, and results measured while firing a solid frozen pellet. Additionally, planned refinement activities toward meeting all requirements for ITER integration will be discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Utah FORGE: Well 16A(78)-32 Core Analysis Results

This dataset features petrographic, X-Ray Diffraction (XRD), and Scanning Electron Microscopy Analyses of core samples from well 16A(78)-32, which serves as the injection well for the Utah FORGE Enhanced Geothermal System (EGS) project. In addition to an overview of the analysis, the following items have been included here: images of 21 entire thin sections in plane-polarized and cross-polarized light from 16 depths, scanning electron microscope back scatter electron photomosaic maps of 21 thin sections from 16 depths, bulk XRD data from 16 depths, clay-sized XRD patterns from 16 depths, an optical petrography report, and scanning electron microscopy and energy dispersive spectroscopy analyses of eight selected samples.

15 GEOTHERMAL ENERGY↗

Transient Pressure Interference During CO2 Injection in Saline Aquifers

Abstract CO2 injection in subsurface geological formations (e.g. deep saline aquifers) causes pressure perturbations over a large area surrounding the injection well. Observation wells are widely considered in geologic CO2 storage (GCS) projects where the pressure perturbation induced by CO2 injection is measured. In this work, we use analytical and numerical modeling tools along with field data to examine the pressure behavior in GCS projects before and after CO2 arrival at an observation well. Prior to CO2 arrival, a baseline pressure trend is established which corresponds to single-phase brine flow across the observation well (approximated by Theis solution). Therefore, analysis of early-time pressure data is straightforward, provides the single-phase flow characteristics (mobility and storativity), and helps establishing a baseline pressure change that can be extended beyond the single-phase flow period at the observation well. Upon CO2 arrival, a departure from this baseline trend is expected. For the pressure to detect the CO2 arrival at an observation well, the departure from baseline pressure behavior must be significant and well above the background noise levels. We use existing analytical models to determine the strength of the expected pressure departure signal from the baseline trend upon CO2 arrival. The strength of the expected pressure departure is found to be directly proportional to the mobility ratio. Accordingly, we establish a criterion to determine whether the pressure at an observation well can detect the CO2 arrival. We present an analysis approach through application to synthetic and field data and show the characteristic pressure behavior before and after CO2 arrival. We show that while generally the pressure can be either above or below the expected baseline pressure trend, it would be likely above the baseline upon CO2 arrival. This is because the mobility ratio becomes less than unity after CO2 arrival. We show that depending on the reservoir characteristics, changes in the pressure trend may or may not be sufficient to detect the CO2 arrival.

Engineering↗

An Experimental Comparison of Cyclic Variations in Diesel–Natural Gas and POMDME–Natural Gas Dual Fuel Combustion

Abstract Cyclic variations in internal combustion engines are caused by various factors, including combustion mixture stratification, in-cylinder flows, local fluctuations in air-fuel ratio, etc. Cyclic variations have a profound impact on engine performance and emissions. In this study, cyclic variations in dual fuel combustion are analyzed, comparing diesel–natural gas (NG) and polyoxymethylene dimethyl ether (POMDME)-NG dual fuel combustion. Cyclic variability was initially quantified using the coefficient of variation of gross indicated mean effective pressure (IMEPg) computed from experimental cylinder pressure data. The cases analyzed in this study had a coefficient of variation (COV) of IMEPg greater than or around 5%, which was the lower limit of onset of instability for this engine. Experiments were performed at two fixed start of injection (SOI) of high-cetane fuel: 310 CAD and 350 CAD. For all experiments, a constant load of 5 bar IMEPg was maintained, and the intake boost pressure and rail pressure were fixed at 1.5 bar and 500 bar, respectively. For each case, 1000 cycles of cylinder pressure data were recorded, filtered, and processed using an in-house heat release analysis code for each cycle. A comparison between individual cycles and the “ensemble averaged cycle” was made for both diesel–NG and POMDME–NG combustion. For the early SOI of 310 CAD, the peak cylinder pressure fluctuations of individual cycle were found to be ± 15 bar for both fuel combinations, compared to the ensemble averaged cycle, and < 1/10th of the cycles had an IMEPg lower than 0.05 bar of the ensemble averaged cycle. However, the peak pressure fluctuations were found to be lower for POMDME–NG (±3 bar) than diesel–NG dual fuel combustion at 350 CAD SOI, indicating lower cyclic variations. The higher reactivity of POMDME helped reduce fluctuations in combustion phasing at the retarded SOI. The presence of cycles of deterioration and cycles of recovery were also observed with diesel–NG combustion for 310 CAD SOI, and the scatter in the IMEPg return map was similar for both fuel combinations. The IMEPg return map for POMDME–NG combustion was less scattered at the 350 CAD SOI.

Engineering↗

Space tug economic analysis study. Volume 1: Executive summary

An economic analysis of space tug operations is presented. The space tug is defined as any liquid propulsion stage under 100,000 pounds propellant loading that is flown from the space shuttle cargo bay. Two classes of vehicles are the orbit injection stages and reusable space tugs. The vehicle configurations, propellant combinations, and operating modes used for the study are reported. The summary contains data on the study approach, results, conclusions, and recommendations.

Source record↗

Determination of Venus winds by ground-based radio tracking of the VEGA balloons

A global array of 20 radio observatories was used to measure the three-dimensional position and velocity of the two meteorological balloons that were injected into the equatorial region of the Venus atmosphere near Venus midnight by the VEGA spacecraft on 11 and 15 June 1985. Initial analysis of only radial velocities indicates that each balloon was blown westward about 11,500 kilometers (8,000 kilometers on the night side) by zonal winds with a mean speed of about 70 meters per second. Excursions of the data from a model of constant zonal velocity were generally less than 3 meters per second; however, a much larger variation was evident near the end of the flight of the second balloon. Consistent systematic trends in the residuals for both balloons indicate the possibility of a solar-fixed atmospheric feature. Rapid variations in balloon velocity were often detected within a single transmission (330 seconds); however, they may represent not only atmospheric motions but also self-induced aerodynamic motions of the balloon.

R A Preston↗

Analysis of the Injection of a Heated, Turbulent Jet into a Moving Mainstream, with Emphasis on a Thermal Discharge in a Waterway

An experimental and theoretical investigation was undertaken to study the trajectory and growth of thermal effluents having a range of discharge velocities and temperatures. The discharge of a turbulent effluent into a waterway was mathematically modeled as a submerged jet injection process by using an integral method which accounts for natural fluid mechanisms such as turbulence, entrainment, buoyancy, and heat transfer. The analytical results are supported by experimental data and demonstrate the usefulness of the theory for estimating the location and size of the effluent with respect to the discharge point. The capability of predicting jet flow properties, as well as two- and three-dimensional jet paths, was enhanced by obtaining the jet cross-sectional area during the solution of the conservation equations. Realistic estimates of temperature in the effluent were acquired by accounting for heat losses in the jet flow due to forced convection and to entrainment of free-stream fluid into the jet.

Campbell, J. F.↗