Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Importance sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Large-Scale Multiplexed Quantitative Discovery Proteomics Enabled by the Use of an O-18-Labeled “Universal” Reference Sample

Quantitative comparison of protein abundances across a relatively large number of patient samples is an important challenge for clinical proteomic applications. Herein we describe a dual-quantitation strategy that allows the simultaneous integration of complementary label-free and stable isotope labeling based approaches without increasing the number of LC-MS analyses. The approach utilizes a stable isotope 18O-labeled “universal” reference sample as a comprehensive set of internal standards spiked into each individually processed unlabeled patient sample. The quantitative data are based on both the direct 16O-MS intensities for label-free quantitation and the 16O/18O isotopic peptide pair ratios that compare each patient sample to the identical labeled reference. The effectiveness of this dual-quantitation approach for large scale quantitative proteomics is demonstrated by the application to a set of 38 clinical plasma samples from surviving and non-surviving severe burn patients. With the coupling of immunoaffinity depletion, cysteinyl-peptide enrichment based fractionation, high resolution LC-MS measurements, and the dual-quantitation approach, a total of 318 proteins were confidently quantified with at least two peptides and 263 proteins were quantified by both approaches. The strategy also enabled a direct comparison between the two approaches with the labeling approach showing significantly better precision in quantitation while the label-free approach resulted in more protein identifications. The relative abundance differences determined by the two approaches also show strong correlation. Finally, the dual-quantitation strategy allowed us to identify more candidate protein biomarkers, illustrating the complementary nature of the two quantitative methods.

59 BASIC BIOLOGICAL SCIENCES↗

ASX O-ring Life Testing Using a LAW High Bound Melter Feed Simulant (Final Report)

The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is planning to utilize an Isolok sampler to sample the contents of the Low Activity Waste (LAW) and High Level Waste (HLW) Melter Feed Preparation Vessels (MFPV) as well as the contents of the LAW Concentrate Receipt Vessel (CRV). Over the course of testing, it has been recognized that the long term reliability of the o-ring seals in the Isolok sampler are an important component in sampling. The Isolok sampler will be collecting samples of melter feed that contain a high percentage of highly abrasive particles which can impact the life of the o-rings. Although o-ring life in normal service is typically several hundred thousand cycles (such as in the air cylinders and other non-abrasive environments), no data are available for the life of the o-ring seals in this abrasive environment. To address this concern, a Test Exception was issued to perform testing to determine whether the o-rings in an Isolok sampler will continue to function through one year of projected HLW MFPV sampler operation, or approximately 7,000 sampler piston cycles. This final report provides results of the o-ring testing that was performed with the ASX sampler.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Influence of Bulk Chemical Composition on Relative Sensitivity Factors for 55Mn/52Cr by SIMS: Implications for the 53Mn-53Cr Chronometer

The {sup 53}Mn-{sup 53}Cr systematics of meteorite samples provide an important high resolution chronometer for early solar system events. Accurate determination of the initial abundance of {sup 53}Mn ({tau}{sub 1/2} = 3.7 Ma) by secondary ion mass spectrometry (SIMS) is dependent on properly correcting for differing ion yields between Mn and Cr by use of a relative sensitivity factor (RSF). Ideal standards for SIMS analysis should be compositionally and structurally similar to the sample of interest. However, previously published Mn-Cr studies rely on few standards (e.g., San Carlos olivine, NIST 610 glass) despite significant variations in chemical composition. We investigate a potential correlation between RSF and bulk chemical composition by determining RSFs for {sup 55}Mn/{sup 52}Cr in 11 silicate glass and mineral standards (San Carlos olivine, Mainz glasses KL2-G, ML3B-G, StHs6/80-G, GOR128-G, BM90/21-G, and T1-G, NIST 610 glass, and three LLNL pyroxene-composition glasses). All standards were measured on the Cameca ims-3f ion microprobe at LLNL, and a subset were also measured on the Cameca ims-1270 ion microprobe at the Geological Survey of Japan. The standards cover a range of bulk chemical compositions with SiO{sub 2} contents of 40-71 wt.%, FeO contents of 0.05-20 wt.% and Mn/Cr ratios between 0.4 and 58. We obtained RSF values ranging from 0.83 to 1.15. The data obtained on the ims-1270 ion microprobe are within {approx}10% of the RSF values obtained on the ims-3f ion microprobe, and the RSF determined for San Carlos olivine (0.86) is in good agreement with previously published data. The typical approach to calculating an RSF from multiple standard measurements involves making a linear fit to measured {sup 55}Mn/{sup 52}Cr versus true {sup 55}Mn/{sup 52}Cr. This approach may be satisfactory for materials of similar composition, but fails when compositions vary significantly. This is best illustrated by the {approx}30% change in RSF we see between glasses with similar Mn/Cr ratios but variable Fe and Na content. We are developing an approach that uses multivariate analysis to evaluate the importance of different chemical components in controlling the RSF and predict the RSF of unknowns when standards of appropriate composition are not available. Our analysis suggests that Fe, Si, and Na are key compositional factors in these silicate standards. The RSF is positively correlated with Fe and Si and negatively correlated with Na. Work is currently underway to extend this analysis to a wider range of chemical compositions and to evaluate the variability of RSF on measurements obtained by NanoSIMS.

58 GEOSCIENCES↗

THE SMALL ISOLATED GAS-RICH IRREGULAR DWARF (SIGRID) GALAXY SAMPLE: DESCRIPTION AND FIRST RESULTS

Using an optically unbiased selection process based on the HIPASS neutral hydrogen survey, we have selected a sample of 83 spatially isolated, gas-rich dwarf galaxies in the southern hemisphere with cz between 350 and 1650 km s{sup -1}, and with R-band luminosities and H I masses less than that of the Small Magellanic Cloud. The sample is an important population of dwarf galaxies in the local universe, all with ongoing star formation, and most of which have no existing spectroscopic data. We are measuring the chemical abundances of these galaxies, using the integral-field spectrograph on the Australian National University 2.3 m telescope, the Wide-Field Spectrograph. This paper describes our survey criteria and procedures, lists the survey sample, and reports on initial observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Rapid method to determine 226Ra in steel samples

The rapid measurement of 226 Ra in steel samples is very important in the event of a radiological emergency. 226 Ra (T 1/2 = 1600 y) is a natural radionuclide present in the environment and a highly toxic alpha-emitter. Due to its long life and tendency to concentrate in bones, 226 Ra ingestion or inhalation can lead to significant committed dose to individuals. A new method for the determination of 226 Ra in steel samples has been developed at the Savannah River Environmental Laboratory. The new method employs a rugged acid digestion method that includes hydrofluoric acid, followed by a single precipitation step to rapidly preconcentrate the radium and remove most of the dissolved steel sample matrix. Radium is then separated using a combination of cation exchange and extraction chromatography, and 226 Ra is measured by alpha spectrometry. This approach has a sample preparation time of ~ 8 h for steel samples, has a very high tracer yield (> 88%), and removes interferences effectively. A 133 Ba yield tracer is used so that samples can be counted immediately following the separation method, avoiding lengthy ingrowth times that are required in other methods.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

On the development of the quantitative texture analysis and its application in solving problems of the Earth sciences

A history of texture analysis (TA) evolution is shown, beginning from the first experimental and theoretical attempts to find and characterize preferred orientations of crystal lattices of grains in real polycrystalline samples. Stages of formation of TA theoretical apparatus, its basic elements, and also application of its capabilities for quantitatively describing anisotropic properties of textured samples are discussed. Attention is also paid to the limitations and difficulties associated with the analysis. The application of the quantitative TA apparatus is demonstrated by example describing elastic properties of textured materials up to multiphase samples containing pores and cracks. A wide scope of TA includes the analysis based on neutron scattering which has been effectively developed at the Frank Laboratory of Neutron Physics. A practical opportunity to determine the bulk crystallographic textures of single-phase and multiphase materials is offered by the use of modern neutron diffractometers, including the SKAT diffractometer at the IBR-2 pulsed reactor. This is especially important for studying samples of natural rocks. The examples given show how the neutron scattering data for the quantitative TA are used in combination with other physical and petrological methods for solving fundamental problems of geology and geophysics based on the analysis of a structure and properties of the Earth’s lithosphere matter. The review includes a detailed list of references of original works concerning the TA elaboration, overview publications and monographs, and also information on the most popular TA-related software.

36 MATERIALS SCIENCE↗

Determination of an Environmental Background Level of Sr-90 in Urine for the Hanford Bioassay Program Determination of an Environmental Background Level of Sr-90 in Urine for the Hanford Bioassay Program

During the decommissioning and maintenance of some of the facilities at the U.S. Department of Energy Hanford Site in Washington State, workers have potential for a 90Sr intake. However, because of worldwide radioactive fallout, 90Sr is present in our environment, and can be detectable in routine urine bioassay samples. It is important for the Hanford Site bioassay program to discern an occupational intake from a non-occupational environmental one. A detailed study of the background 90Sr in the urine of unexposed Hanford workers was performed. A survey of the Hanford Site bioassay database found 128 Hanford workers who were hired between 1997 and 2002 and who had a very low potential for an occupational exposure prior to the baseline strontium urinalysis. Each urinalysis sample represented excretion during an approximate 24-hr period. The arithmetic mean value for the 128 pre-exposure baselines was 3.6 ± 5.1 mBq d-1. The 90Sr activities in urine varied from -12 to 20 mBq. The 99th percentile result was 16.4 mBqd-1, which was interpreted to mean that 1% of Hanford workers not occupationally exposed to strontium might exceed 16.4 mBq d-1.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reduced Magnetization and Loss in Ag-Mg Sheathed Bi2212 Wires: Systematics With Sample Twist Pitch and Length

Suppression of magnetization and effective filament diameter (d eff ) with twisting was investigated for a series of recent Bi2212 strands manufactured by Oxford Superconducting Technologies. We measured magnetization as a function of field (out to 14 T), at 5.1 K, of twisted and nontwisted 37 × 18 double restack design strands. The samples were helical coils 5-6 mm in height and approximately 5 mm in diameter. The strand diameter was 0.8 mm. The magnetization of samples having twist pitches of 25.4, 12.7, and 6.35 mm were examined and compared to nontwisted samples of the same filament configuration. The critical state model was used to extract the 12-T d eff from magnetization data for comparison. Twisting the samples reduced d eff by a factor of 1.5-3. The d eff was shown to increase both with L and L p . Mathematical expressions, based upon the anisotropic continuum model, were fit to the data, and a parameter γ 2 , which quantifies the electrical connectivity perpendicular to the filament axis, was extracted. The bundle-to-bundle connectivity along the radial axis was found to be approximately 0.2%. The d eff was substantially reduced with L p . In addition, the importance of understanding sample length dependence for quantitative measurements is discussed.

36 MATERIALS SCIENCE↗

147 Nd Quantification Using HSCCC-Purified Samples

Quantifying the fission product 147 Nd in nuclear debris samples is an important component of post-detonation nuclear forensics. The most accurate quantifications are obtained when Nd is purified from all other fission products, actinides, activation products, and environmental matrix contained within the debris. In this study, a recently developed method for Nd purification was tested, purifying 147 Nd from solutions of mixed fission products using high-speed counter-current chromatography (HSCCC). Importantly, the new method allowed for faster elution of Nd from the column as compared with established high performance liquid chromatography (HPLC) methods, and resulted in accurate/precise 147 Nd quantification by gamma-ray spectrometry. While the up-front equipment costs associated with HSCCC may be higher, its operational costs are on par with those of HPLC (solvents, extractants, power). Gas-flow proportional beta decay counting revealed contamination from the nearest neighbor lanthanide 143 Pr (a gamma-silent radioisotope) in the HSCCC-purified samples, but the activity contribution from 147 Nd could still be quantified. Remarkably consistent elution profiles were observed for the HSCCC method, spanning rare earth element (REE) loadings of more than 10 orders of magnitude (tracer to mmol quantities). In conclusion, the reliability and speed of the new method suggest utility for the rapid separation and quantification of 147 Nd in unknown samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design of a compact ultrahigh vacuum-compatible setup for the analysis of chemical vapor deposition processes

Optimizing thin film deposition techniques requires contamination-free transfer from the reactor into an ultrahigh vacuum (UHV) chamber for surface science analysis. A very compact, multifunctional Chemical Vapor Deposition (CVD) reactor for direct attachment to any typical UHV system for thin film analysis was designed and built. Besides compactness, fast, easy, and at the same time ultimately clean sample transfer between reactor and UHV was a major goal. It was achieved by a combination of sample manipulation parts, sample heater, and a shutter mechanism designed to fit all into a NW38 Conflat six-ways cross. The present reactor design is versatile to be employed for all commonly employed variants of CVD, including Atomic Layer Deposition. A demonstration of the functionality of the system is provided. First results of the setup (attached to an Omicron Multiprobe x-ray photoelectron spectroscopy system) on the temperature dependence of Pulsed Spray Evaporation-CVD of Ni films from Ni acetylacetonate as the precursor demonstrate the reactor performance and illustrate the importance of clean sample transfer without breaking vacuum in order to obtain unambiguous results on the quality of CVD-grown thin Ni films. The widely applicable design holds promise for future systematic studies of the fundamental processes during chemical vapor deposition or atomic layer deposition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerated Irradiation and Qualification of Ceramic Nuclear Fuels

Accelerated irradiation efforts are an important topic in accelerated qualification of new nuclear fuel concepts for light water reactor (LWRs), microreactors, and other special purpose reactors. Accelerated fuel qualification combines both experimental and modeling work to expedite the total qualification time from approximately 20-25 years to 5-10 years timeframe. The scope covered under the current work package focuses on the experimental contributions for the neutron irradiations. Accelerated irradiation aims to reduce the total time needed for neutron irradiation to achieve targeted burnup, which is timely using conventional irradiation profiles. The purpose of this report is to detail the samples preparation for such irradiations, which contain standard, medium, and large grain undoped UO 2 , as well as large grain, Cr 2 O 3 -doped UO 2 . The data that will be generated from the irradiation of these samples will yield important information regarding fission gas retention as a function of grain size and the effect that Cr dopants have on diffusivity of fission gases.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Room temperature plasma-etching and surface passivation of far-ultraviolet Al mirrors using electron beam generated plasmas

The development of optical systems operating in the far ultraviolet range (FUV, λ=100-200 nm) is limited by the efficiency of passivated aluminum (Al) mirrors. Although it is presently possible to obtain high-reflectivity FUV mirrors through physical vapor deposition, the process involves deposition with substrates at high temperatures, which is technically challenging for large optical elements. A novel passivation procedure for bare Al mirrors is reported. The treatment consisted of using a low-temperature electron-beam generated plasma produced in a gas mixture of Ar and SF6 to etch away the native oxide layer from the Al film, while simultaneously promoting the generation of a thin aluminum tri-fluoride (AlF3) layer on the Al surface. In the first section we analyze the effect of varying both ion energy and SF6 concentration on the FUV reflectance, thickness, composition, and surface morphology of the resulting AlF3 protective layers. In the second section, the reflectivity of samples is optimized at selected important FUV wavelengths for astronomical observations. Notably, samples attained state-of-the-art reflectances of 75% at 108.5 nm (He Lyman γ), 91% at 121.6 nm (H Lyman α), 90% at 130.4 nm (OI), and of 95% at 155.0 nm (C IV). The stability over time of these passivated mirrors is also investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectromicroscopy of C 60 and azafullerene C 59 N: Identifying surface adsorbed water

C 60 fullerene crystals may serve as important catalysts for interstellar organic chemistry. To explore this possibility, the electronic structures of free-standing powders of C 60 and (C 59 N) 2 azafullerenes are characterized using X-ray microscopy with near-edge X-ray adsorption fine structure (NEXAFS) spectroscopy, closely coupled with density functional theory (DFT) calculations. This is supported with X-ray photoelectron spectroscopy (XPS) measurements and associated core-level shift DFT calculations. We compare the oxygen 1s spectra from oxygen impurities in C 60 and C 59 N, and calculate a range of possible oxidized and hydroxylated structures and associated formation barriers. These results allow us to propose a model for the oxygen present in these samples, notably the importance of water surface adsorption and possible ice formation. Water adsorption on C 60 crystal surfaces may prove important for astrobiological studies of interstellar amino acid formation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Review of African Swine Fever and the Potential for Introduction into the United States and the Possibility of Subsequent Establishment in Feral Swine and Native Ticks

African swine fever (ASF) is caused by African swine fever virus (ASFV), which can cause substantial morbidity and mortality events in swine. The virus can be transmitted via direct and indirect contacts with infected swine, their products, or competent vector species, especially Ornithodoros ticks. Africa and much of Eastern Europe are endemic for ASF; a viral introduction to countries that are currently ASF free could have severe economic consequences due to the loss of production from infected animals and the trade restrictions that would likely be imposed as a result of an outbreak. We identified vulnerabilities that could lead to ASFV introduction or persistence in the United States or other ASF-free regions. Both legal and illegal movements of live animals, as well as the importation of animal products, byproducts, and animal feed, pose a risk of virus introduction. Each route is described, and current regulations designed to prevent ASFV and other pathogens from entering the United States are outlined. Furthermore, existing ASFV research gaps are highlighted. Laboratory experiments to evaluate multiple species of Ornithodoros ticks that have yet to be characterized would be useful to understand vector competence, host preferences, and distribution of competent soft tick vectors in relation to high pig production areas as well as regions with high feral swine (wild boar or similar) densities. Knowledge relative to antigenic viral proteins that contribute to host response and determination of immune mechanisms that lead to protection are foundational in the quest for a vaccine. Finally, sampling of illegally imported and confiscated wild suid products for ASFV could shed light on the types of products being imported and provide a more informed perspective relative to the risk of ASFV importation.

Veterinary Sciences↗

Boron isotopic analysis in bulk silicate materials using the Neoma MS/MS MC-ICP-MS

Boron (B) isotopes are a valuable tracer with applications ranging from geological, environmental, and nuclear studies because B isotopic fractionation is highly sensitive to chemical processes yielding distinct isotopic trends in natural and anthropogenic systems. Despite this wide applicability, there remain relatively few measurements on well-described reference materials and in some cases, poor agreement between various methods. We report a method for boron isotope ratio measurement in solution on the Neoma MS/MS MC-ICP-MS specifically targeting bulk silicates. We evaluate the performance of the method and instrument as it relates to the measurement of the absolute boron isotope ratio ( 10 B/ 11 B). The results indicate that the method produces data in agreement with literature values and that the sample–standard bracketing technique is appropriate for the Neoma MS/MS MC-ICP-MS which has been in use for decades on previous generation instruments. Careful tuning of the MS/MS lenses is required to obtain precision comparable to non MS/MS equipped MC-ICP-MS. With careful tuning, internal and external precisions of ∼0.3‰ were achieved. However, when the MS/MS is not properly tuned external precisions exceed 3‰. Nevertheless, our results for IAEA B-6, BCR-2, BHVO-2 and W-2a reference materials overlap the 1σ range of previously reported 10 B/ 11 B. Data are reported for total boron quantities down to a few tens of nanograms. Our procedure yielded blanks as low as 3 ng but up to 29 ng, making blank corrections important for small samples sizes in the few 10s of nanogram range. We report B isotope ratios for AGV-2G, SL-1G, GSC-2G, GSD-2G, GSE-2G, RLS-132, RLS-140, NKT-1G, and T1-G glass reference materials that have not been previously reported in the literature.

Scott, Sean R. [Pacific Northwest National Laborat↗

PRIMUS: Galaxy clustering as a function of luminosity and color at 0.2 < z < 1

We present measurements of the luminosity and color-dependence of galaxy clustering at 0.2 < z < 1.0 in the Prism Multi-object Survey. We quantify the clustering with the redshift-space and projected two-point correlation functions, ξ(r{sub p} , π) and w{sub p} (r{sub p} ), using volume-limited samples constructed from a parent sample of over ∼130, 000 galaxies with robust redshifts in seven independent fields covering 9 deg{sup 2} of sky. We quantify how the scale-dependent clustering amplitude increases with increasing luminosity and redder color, with relatively small errors over large volumes. We find that red galaxies have stronger small-scale (0.1 Mpc h {sup –1} < r{sub p} < 1 Mpc h {sup –1}) clustering and steeper correlation functions compared to blue galaxies, as well as a strong color dependent clustering within the red sequence alone. We interpret our measured clustering trends in terms of galaxy bias and obtain values of b {sub gal} ≈ 0.9-2.5, quantifying how galaxies are biased tracers of dark matter depending on their luminosity and color. We also interpret the color dependence with mock catalogs, and find that the clustering of blue galaxies is nearly constant with color, while redder galaxies have stronger clustering in the one-halo term due to a higher satellite galaxy fraction. In addition, we measure the evolution of the clustering strength and bias, and we do not detect statistically significant departures from passive evolution. We argue that the luminosity- and color-environment (or halo mass) relations of galaxies have not significantly evolved since z ∼ 1. Finally, using jackknife subsampling methods, we find that sampling fluctuations are important and that the COSMOS field is generally an outlier, due to having more overdense structures than other fields; we find that 'cosmic variance' can be a significant source of uncertainty for high-redshift clustering measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Exploring unsupervised top tagging using Bayesian inference

Recognizing hadronically decaying top-quark jets in a sample of jets, or even its total fraction in the sample, is an important step in many LHC searches for Standard Model and Beyond Standard Model physics as well. Although there exists outstanding top-tagger algorithms, their construction and their expected performance rely on Montecarlo simulations, which may induce potential biases. For these reasons we develop two simple unsupervised top-tagger algorithms based on performing Bayesian inference on a mixture model. In one of them we use as the observed variable a new geometrically-based observable \tilde{A}_{3} A ̃ 3 , and in the other we consider the more traditional \tau_{3}/\tau_{2} τ 3 / τ 2 N N -subjettiness ratio, which yields a better performance. As expected, we find that the unsupervised tagger performance is below existing supervised taggers, reaching expected Area Under Curve AUC \sim 0.80-0.81 ∼ 0.80 − 0.81 and accuracies of about 69% - − 75% in a full range of sample purity. However, these performances are more robust to possible biases in the Montecarlo that their supervised counterparts. Our findings are a step towards exploring and considering simpler and unbiased taggers.

Alvarez, Ezequiel↗

Microfluidic sorting of protein nanocrystals by size for X-ray free-electron laser diffraction

The advent and application of the X-ray free-electron laser (XFEL) has uncovered the structures of proteins that could not previously be solved using traditional crystallography. While this new technology is powerful, optimization of the process is still needed to improve data quality and analysis efficiency. One area is sample heterogeneity, where variations in crystal size (among other factors) lead to the requirement of large data sets (and thus 10–100 mg of protein) for determining accurate structure factors. To decrease sample dispersity, we developed a high-throughput microfluidic sorter operating on the principle of dielectrophoresis, whereby polydisperse particles can be transported into various fluid streams for size fractionation. Using this microsorter, we isolated several milliliters of photosystem I nanocrystal fractions ranging from 200 to 600 nm in size as characterized by dynamic light scattering, nanoparticle tracking, and electron microscopy. Sorted nanocrystals were delivered in a liquid jet via the gas dynamic virtual nozzle into the path of the XFEL at the Linac Coherent Light Source. We obtained diffraction to ∼4 Å resolution, indicating that the small crystals were not damaged by the sorting process. We also observed the shape transforms of photosystem I nanocrystals, demonstrating that our device can optimize data collection for the shape transform-based phasing method. Using simulations, we show that narrow crystal size distributions can significantly improve merged data quality in serial crystallography. From this proof-of-concept work, we expect that the automated size-sorting of protein crystals will become an important step for sample production by reducing the amount of protein needed for a high quality final structure and the development of novel phasing methods that exploit inter-Bragg reflection intensities or use variations in beam intensity for radiation damage-induced phasing. This method will also permit an analysis of the dependence of crystal quality on crystal size.

36 MATERIALS SCIENCE↗