Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IONIZATION CHAMBER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Improving the characterization of fusion in a MuSIC detector by spatial localization

Multi-Sampling Ionization Chambers (MuSIC) provide an efficient means of measuring nuclear reactions with low beam rates (< 10 6 pps). However, in comparison to thin-target measurements, prior measurements using MuSIC detectors all manifest fusion excitation functions with wide error bars in the energy dimension. This uncertainty limits the applicability of these devices in measuring near and sub-barrier fusion cross-sections. Key to overcoming this limitation is spatial localization of the fusion in the detector. By comparing the measured ionization in the MuSIC detector with accurate energy loss calculations the position of the fusion in the detector is determined. The analysis not only provides the desired improvement in energy resolution, but it also allows extraction of the atomic number of the evaporation residues following fusion. Furthermore, the effectiveness of this approach is demonstrated for 18 O+ 12 C measured with MuSIC@Indiana.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of fragment-correlated γ-ray emission from 252 Cf(sf)

This paper presents recent experimental results on the yield of prompt fission γ rays from the spontaneous fission of 252 Cf. We use an ionization chamber to tag fission events and measure the masses and kinetic energies of the fission fragments and trans-stilbene organic scintillators to measure the neutrons and γ rays emitted by the fission fragments. The combination of the ionization chamber and trans-stilbene scintillators allows us to determine the properties of neutrons and γ rays in coincidence with the fragments. The yield of γ rays is known to be influenced by the angular momenta (AM) of the fission fragments. We present experimental evidence indicating that the total γ-ray multiplicity, i.e., the sum of both fragments' emission, saturates at sufficiently high internal fragment excitation energies. We also observe distinct behaviors for the yield of γ rays from the light and heavy fragments, which for certain mass and total kinetic energy (TKE) regions are weakly or anticorrelated, indicating the presence of complex AM generation modes. We also observed a mass- and TKE-dependent anisotropy of the γ rays, which challenges and expands on the conventional notion that the fragments' AM are always aligned perpendicularly to the fission axis. Furthermore, the dependence of the anisotropy on mass and TKE indicates a dependence of these properties on the specific fission channels, thus providing an insight into the deformations and dynamics in fission and their connection with experimentally observable quantities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental determination of cosmic ray charged particle intensity profiles in the atmosphere

Absolute cosmic-ray free air ionization and charged particle fluxes and dose rates throughout the atmosphere were measured on a series of balloon flights that commenced in 1968. Argon-filled ionization chambers equipped with solid-state electrometers, with different gas pressures and steel wall thicknesses, and a pair of aluminum-wall Gm counters have provided the basic data. These data are supplemented by measurements with air-filled and tissue equivalent ionization chambers and a scintillation spectrometer. Laboratory experiments together with analyses of the theoretical aspects of the detector responses to cosmic radiation indicate that these profiles can be determined to an overall accuracy of + or - 5 percent.

Lowder, W. M.↗

Application of radiochromic gel dosimetry to commissioning of a megavoltage research linear accelerator for small–field animal irradiation studies

To develop and implement an efficient and accurate commissioning procedure for small-field static beam animal irradiation studies on an MV research linear accelerator (Linatron-M9) using radiochromic gel dosimetry. The research linear accelerator (Linatron-M9) is a 9 MV linac with a static fixed collimator opening of 5.08 cm diameter. Lead collimators were manually placed to create smaller fields of 2 × 2 cm 2 , 1 × 1 cm 2 , and 0.5 × 0.5 cm 2 . Relative dosimetry measurements were performed, including profiles, percent depth dose (PDD) curves, beam divergence, and relative output factors using various dosimetry tools, including a small volume ionization chamber (A14), GAFCHROMIC™ EBT3 film, and Clearview gel dosimeters. The gel dosimeter was used to provide a 3D volumetric reference of the irradiated fields. The Linatron profiles and relative output factors were extracted at a reference depth of 2 cm with the output factor measured relative to the 2 × 2 cm 2 reference field. Absolute dosimetry was performed using A14 ionization chamber measurements, which were verified using a national standards laboratory remote dosimetry service. Absolute dosimetry measurements were confirmed within 1.4% (k = 2, 95% confidence = 5%). The relative output factor of the small fields measured with films and gels agreed with a maximum relative percent error difference between the two methods of 1.1 % for the 1 × 1 cm 2 field and 4.3 % for the 0.5 × 0.5 cm 2 field. These relative errors were primarily due to the variability in the collimator positioning. The measured beam profiles demonstrated excellent agreement for beam size (measured as FWHM), within approximately 0.8 mm (or less). Film measurements were more accurate in the penumbra region due to the film’s finer resolution compared with the gel dosimeter. Following the van Dyk criteria, the PDD values of the film and gel measurements agree within 11% in the buildup region starting from 0.5 cm depth and within 2.6 % beyond maximum dose and into the fall-off region for depths up to 5 cm. The 2D beam profile isodose lines agree within 0.5 mm in all regions for the 0.5 × 0.5 cm 2 and the 1 × 1 cm 2 fields and within 1 mm for the larger field of 2 × 2 cm 2 . The 2D PDD curves agree within approximately 2% of the maximum in the typical therapy region (1–4 cm) for the 1 × 1 cm 2 and 2 × 2 cm 2 and within 5% for the 0.5 × 0.5 cm 2 field. This work provides a commissioning process to measure the beam characteristics of a fixed beam MV accelerator with detailed dosimetric evaluation for its implementation in megavoltage small animal irradiation studies. Radiochromic gel dosimeters are efficient small-field relative dosimetry tools providing 3D dose measurements allowing for full representation of dose, dosimeter misalignment corrections and high reproducibility with low inter-dosimeter variability. Altogether, radiochromic gels are valuable for fast, full relative dosimetry commissioning in comparison to films for application in high-energy small-field animal irradiation studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Total Kinetic Energy and Fragment Mass Distribution of Neutron-Induced Fission of U-233

Properties of fission in U-233 were studied at the Los Alamos Neutron Science Center (LANSCE) at incident neutron energies from thermal to 40 MeV at both the Lujan Neutron Scattering Center flight path 12 and at WNR flight path 90-Left from Dec 2016 to Jan 2017. Fission fragments are observed in coincidence using a twin ionization chamber with Frisch grids. The average total kinetic energy (TKE) released from fission and fragment mass distributions are calculated from observations of energy deposited in the detector and conservation of mass and momentum. Accurate experimental measurements of these parameters are necessary to better understand the fission process and obtain data necessary for calculating criticality. The average TKE released from fission has been well characterized for several isotopes at thermal neutron energy, however, few measurements have been made at fast neutron energies. This experiment expands on previous successful experiments using an ionization chamber to measure TKE and fragment mass distributions of U-235, U-238, and Pu-239. This experiment requires the full spectrum of neutron energies and can therefore only be performed at a small number of facilities in the world. The required full neutron energy spectrum is obtained by combining measurements from WNR 90L and Lujan FP12 at LANSCE.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TH-AB-201-08: Ion Chamber Dose Measurements - Problems with the Temperature-Pressure Correction Factor

Purpose: To investigate the behavior of ionization chambers over a wide pressure range. Methods: Three cylindrical and two parallel-plate designs of ion chamber were investigated. The ion chambers were placed in vessel where the pressure was varied from atmospheric (101 kPa) down to 5 kPa. Measurements were made using 60Co and high-energy electron beams. The pressure was measured to better than 0.1% and multiple data sets were obtained for each chamber at both polarities to investigate pressure cycling and dependency on the sign of the charge collected. Results: For all types of chamber, the ionization current, corrected using the standard PTP, showed a similar behaviour. Deviations from the standard theory were generally small for Co-60 but very significant for electron beams, up to 20 % below P = 10 kPa. The effect was found to be always larger when collecting negative charge, suggesting a dependence on free-electron collection. The most likely source of such electrons is low-energy electrons emitted from the electrodes. This signal would be independent of air pressure within the chamber cavity. The data was analyzed to extract this signal and it was found to be a non-negligible component of the ionization current at atmospheric pressure. In the case of the parallel plate chambers, the effect was approximately 0.25 %. For the cylindrical chambers the effect was larger - up to 1.2 % - and dependent on the chamber type, which would be consistent with electron emission from different wall materials. For the electron beams, the correction factor was dependent on the electron energy and approximately double that observed in 60Co. Conclusion: Measurements have indicated significant deviations of the standard pressure correction that are consistent with electron emission from chamber electrodes. This has implications for both primary standard and reference ion chamber-based dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative assessment of the accuracy of dose calculation using pencil beam and Monte Carlo algorithms and requirements for clinical quality assurance

To compare the doses calculated using the BrainLAB pencil beam (PB) and Monte Carlo (MC) algorithms for tumors located in various sites including the lung and evaluate quality assurance procedures required for the verification of the accuracy of dose calculation. The dose-calculation accuracy of PB and MC was also assessed quantitatively with measurement using ionization chamber and Gafchromic films placed in solid water and heterogeneous phantoms. The dose was calculated using PB convolution and MC algorithms in the iPlan treatment planning system from BrainLAB. The dose calculation was performed on the patient's computed tomography images with lesions in various treatment sites including 5 lungs, 5 prostates, 4 brains, 2 head and necks, and 2 paraspinal tissues. A combination of conventional, conformal, and intensity-modulated radiation therapy plans was used in dose calculation. The leaf sequence from intensity-modulated radiation therapy plans or beam shapes from conformal plans and monitor units and other planning parameters calculated by the PB were identical for calculating dose with MC. Heterogeneity correction was considered in both PB and MC dose calculations. Dose-volume parameters such as V95 (volume covered by 95% of prescription dose), dose distributions, and gamma analysis were used to evaluate the calculated dose by PB and MC. The measured doses by ionization chamber and EBT GAFCHROMIC film in solid water and heterogeneous phantoms were used to quantitatively asses the accuracy of dose calculated by PB and MC. The dose-volume histograms and dose distributions calculated by PB and MC in the brain, prostate, paraspinal, and head and neck were in good agreement with one another (within 5%) and provided acceptable planning target volume coverage. However, dose distributions of the patients with lung cancer had large discrepancies. For a plan optimized with PB, the dose coverage was shown as clinically acceptable, whereas in reality, the MC showed a systematic lack of dose coverage. The dose calculated by PB for lung tumors was overestimated by up to 40%. An interesting feature that was observed is that despite large discrepancies in dose-volume histogram coverage of the planning target volume between PB and MC, the point doses at the isocenter (center of the lesions) calculated by both algorithms were within 7% even for lung cases. The dose distributions measured with EBT GAFCHROMIC films in heterogeneous phantoms showed large discrepancies of nearly 15% lower than PB at interfaces between heterogeneous media, where these lower doses measured by the film were in agreement with those by MC. The doses (V95) calculated by MC and PB agreed within 5% for treatment sites with small tissue heterogeneities such as the prostate, brain, head and neck, and paraspinal tumors. Considerable discrepancies, up to 40%, were observed in the dose-volume coverage between MC and PB in lung tumors, which may affect clinical outcomes. The discrepancies between MC and PB increased for 15 MV compared with 6 MV indicating the importance of implementation of accurate clinical treatment planning such as MC. The comparison of point doses is not representative of the discrepancies in dose coverage and might be misleading in evaluating the accuracy of dose calculation between PB and MC. Thus, the clinical quality assurance procedures required to verify the accuracy of dose calculation using PB and MC need to consider measurements of 2- and 3-dimensional dose distributions rather than a single point measurement using heterogeneous phantoms instead of homogenous water-equivalent phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

Quality indexes based on water measurements for low and medium energy x-ray beams: A theoretical study with PENELOPE

Purpose : To study the use of quality indexes based on ratios of absorbed doses in water at two different depths to characterize x-ray beams of low and medium energies. Methods : A total of 55 x-ray beam spectra were generated with the codes XCOMP5R and SPEKCALC and used as input of a series of Monte Carlo simulations performed with PENELOPE, in which the percentage depth doses in water and thek{sub Q,Q{sub 0}} factors, defined in the TRS-398 protocol, were determined for each beam. Some of these calculations were performed by simulating the ionization chamber PTW 30010. Results : The authors found that the relation betweenk{sub Q,Q{sub 0}} and the ratios of absorbed doses at two depths is almost linear. A set of ratios statistically compatible with that showing the best fit has been determined. Conclusions : The results of this study point out which of these ratios of absorbed doses in water could be used to better characterize x-ray beams of low and medium energies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of Neutron-Induced Fission Cross Sections of U, Am, and Cm at n{sub T}OF

Neutron induced fission cross sections of several isotopes have been measured at the CERN n{sub T}OF spallation neutron facility. Between them some measurements involve isotopes ({sup 233}U, {sup 241}Am, {sup 243}Am, {sup 245}Cm) relevant for applications to nuclear technologies. The n{sub T}OF facility delivers neutrons with high instantaneous flux and in a wide energy range, from thermal up to 250 MeV. The experimental apparatus consists of an ionization chamber that discriminates fission fragments and {alpha} particles coming from natural radioactivity of the samples. All the measurements were performed referring to the standard cross section of {sup 235}U.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct measurement of electron beam quality conversion factors using water calorimetry

Purpose: In this work, the authors describe an electron sealed water calorimeter (ESWcal) designed to directly measure absorbed dose to water in clinical electron beams and its use to derive electron beam quality conversion factors for two ionization chamber types. Methods: A functioning calorimeter prototype was constructed in-house and used to obtain reproducible measurements in clinical accelerator-based 6, 9, 12, 16, and 20 MeV electron beams. Corrections for the radiation field perturbation due to the presence of the glass calorimeter vessel were calculated using Monte Carlo (MC) simulations. The conductive heat transfer due to dose gradients and nonwater materials was also accounted for using a commercial finite element method software package. Results: The relative combined standard uncertainty on the ESWcal dose was estimated to be 0.50% for the 9–20 MeV beams and 1.00% for the 6 MeV beam, demonstrating that the development of a water calorimeter-based standard for electron beams over such a wide range of clinically relevant energies is feasible. The largest contributor to the uncertainty was the positioning (Type A, 0.10%–0.40%) and its influence on the perturbation correction (Type B, 0.10%–0.60%). As a preliminary validation, measurements performed with the ESWcal in a 6 MV photon beam were directly compared to results derived from the National Research Council of Canada (NRC) photon beam standard water calorimeter. These two independent devices were shown to agree well within the 0.43% combined relative uncertainty of the ESWcal for this beam type and quality. Absorbed dose electron beam quality conversion factors were measured using the ESWcal for the Exradin A12 and PTW Roos ionization chambers. The photon-electron conversion factor, k{sub ecal}, for the A12 was also experimentally determined. Nonstatistically significant differences of up to 0.7% were found when compared to the calculation-based factors listed in the AAPM’s TG-51 protocol. General agreement between the relative electron energy dependence of the PTW Roos data measured in this work and a recent MC-based study are also shown. Conclusions: This is the first time that water calorimetry has been successfully used to measure electron beam quality conversion factors for energies as low as 6 MeV (R{sub 50} = 2.25 cm)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetric Quantities for Computed Tomography Examinations of Paediatric Patients on the Thoracic and Abdominal Regions

Computed Tomography (CT) is a high dose X ray imaging procedure and its use has rapidly increased in the last two decades fueled by the development of helical CT. The aim of this study is to present values of the dosimetric quantities for CT paediatric examinations of thoracic and abdominal regions. The protocols studied were those of chest, lung-mediastine, chest-abdomen, pulmonary high resolution and mediastine-abdomen, which are the more common examinations performed at ''Hospital Infantil de Mexico Federico Gomez'' in the thoracic-abdominal region. The measurements were performed on a Siemens SOMATOM Sensation 16 CT Scanner and the equipment used was a CT pencil ionization chamber, connected to an electrometer. This system was calibrated for RQT9 CT beam quality. A PMMA head phantom with diameter of 16 cm and length of 15 cm was also used. The dosimetric quantities measured were the weighted air kerma index (C{sub w}), the volumetric dose index (C{sub vol}) and the CT air kerma-length product. It was found that the pulmonary high resolution examination presented the highest values for the C{sub w}(31.1 mGy) and C{sub vol}(11.1 mGy). The examination with the lowest values of these two quantities was the chest-abdomen protocol with 10.5 mGy for C{sub w} and 5.5 mGy for C{sub vol}. However, this protocol presented the highest value for P{sub KL,CT}(282.2 mGy cm) when considering the average clinical length of the examinations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tonopah Test Range Air Monitoring: CY2017 Meteorological, Radiological, and Wind Transported Particulate Observations

In 1963, the U.S. Department of Energy (DOE) (formerly the Atomic Energy Commission [AEC]), implemented Operation Roller Coaster on the Tonopah Test Range (TTR) and an adjacent area of the Nevada Test and Training Range (NTTR) (formerly the Nellis Air Force Range). This operation resulted in radionuclide-contaminated soils at the Double Tracks site and Clean Slate I, II, and III sites. This report documents observations made during ongoing monitoring of radiological, meteorological, and dust conditions at stations installed adjacent to the Clean Slate sites and at the TTR Sandia National Laboratories (SNL) Range Operations Center (ROC). The primary objective of the monitoring effort is to support the DOE Environmental Management Nevada Program (EM NV) in the safe cleanup of the environmental legacy of nuclear device development and testing by determining if wind blowing across the Clean Slate sites is transporting particles of radionuclide-contaminated soil beyond the physical and administrative boundaries of the sites. The monitoring program underwent a significant change during 2017 with the decommissioning of one monitoring station and the establishment of three new stations. Station 400, located within TTR Area 3 and near the ROC, monitors conditions near the local workforce center and was in operation the full calendar year. Stations 401 and 403 are located on the northwest and southeast perimeter fence lines, respectively, of the Clean Slate III site. Station 401 operated throughout 2017, whereas Station 403 began operation at the end of April 2017. Stations 404 and 405 are along the northern and eastern boundary fence, respectively, at Clean Slate II and both began data collection at the end of April 2017. Also at the end of April, the Clean Slate I monitoring site, Station 402, was decommissioned. The stations are located to be generally downwind of the contaminated areas during either north-northwesterly or south-southeasterly winds, which are the predominant wind directions. The stations—which are similar in design to the Community Environmental Monitoring Program (CEMP) stations operating at locations surrounding the Nevada National Security Site and TTR—include meteorological instruments and continuous-flow, low-volume air samplers. Three pressurized ionization chambers for measuring gamma energy are in use at Stations 400, 401, and 403 (formerly at 402). Saltation sensors and saltation traps are deployed at the stations adjacent to the Clean Slate sites. Detailed meteorological data are recorded on data loggers, with periodic uploads via a satellite system to the Western Regional Climate Center (WRCC) at Desert Research Institute (DRI), to monitor instrument and site conditions. Air filter samples are collected every two weeks and the deposits in the saltation traps are collected when a sufficient sample mass for analysis has accumulated (generally a six- to eight-month interval). Dust transport by suspension and saltation is strongly dependent on wind speed. Concentrations of PM10 (particulate matter of aerodynamic diameter ≤10 micrometers [μm], a size fraction of small particles that are suspended in the air and can be easily inhaled) remain low until winds exceed approximately 32 km/hr (20 mph). Saltation particle counts also increase above the same general threshold wind speed. Wind speeds in excess of 32 km/hr (20 mph) occur less than three percent of the time. High winds are associated with two predominant directions: north-northwest and south. In 2017, the very highest winds were from the north, but all winds above 40 km/hr (25 mph) were approximately evenly split between south and northwest directions. The low-volume air samplers collect total suspended dust, and saltating particles are captured by the passive saltation traps, both for radiological analysis. Radionuclide monitoring at the ROC in TTR Area 3 (Station 400) found natural background levels of gross alpha and gross beta radiation. Similar background levels were found on filter samples analyzed using gamma and alpha spectroscopy. The gamma exposure rate data from pressurized ionization chambers (PIC) are comparable to those from the regional CEMP stations. Plutonium concentrations above background values were measured during 2017 from soil samples collected in passive saltation traps and on select air filters from the monitoring stations adjacent to the Clean Slate sites. The background for soils in the region is assumed to be 0.014 pCi/g plutonium-239+240 ( 239+240 Pu) as measured by Turner et al. (2003), whereas the background concentration of suspended 239+240Pu is assumed to be 9.5 x 10 -19 μCi/ml, which was determined by continuous air monitoring at the TTR airport in 1996 and 1997 (SNL, 1998). Background concentrations are exceeded by one to four orders of magnitude by the majority of samples from Clean Slate I, II, and III. The gross alpha and gross beta measurements of the air filters are also generally higher than those measured at the regional CEMP stations, although the gamma exposure rates determined by the PICs located at Clean Slate I and III are similar to CEMP measurements. The highest radionuclide concentrations of suspended dust are associated with individual filter samples from Clean Slate II Station 404 and Clean Slate III Station 401. Both of the stations are downwind of their respective sites during southerly winds, but they are also geographically closer to the highly contaminated detonation areas than the other monitoring stations. Considering all the analyzed samples, the 239+240Pu concentrations are generally higher for the Clean Slate II samples compared with those from Clean Slate III. The highest gross alpha and gross beta results are also observed for the Clean Slate II stations. The highest radionuclide concentrations are measured on the smaller (≤63 μm) saltation-sized particles and particulate matter collected downwind of each site. Nonetheless, traps oriented to collect dust moving toward the contamination areas also had plutonium concentrations significantly above background values, which is consistent with observations of low-level contamination dispersed beyond the fenced area. All the observed 239+240 Pu concentrations are below the risk-based action level (25 millirem per year, equivalent to a 239+240 Pu concentration of 4,120 pCi/g for an industrial worker scenario; U.S. DOE, 2014). The meteorological and particulate matter monitoring indicate that conditions for wind-borne contaminant movement exist at the Clean Slate sites, and that transport of radionuclide-contaminated soil by both suspension and saltation is occurring. The Corrective Action Unit (CAU) closure strategy uses a risk-based approach, whereby acceptable contaminant concentrations are determined as a function of anticipated human exposure. This strategy is consistent with the fence lines at the Clean Slate sites encircling areas of higher concentration and the observed presence of lower concentrations of contamination outside the fences.

54 ENVIRONMENTAL SCIENCES↗

Potential High Resolution Dosimeters For MRT

Microbeam Radiation Therapy (MRT) uses highly collimated, quasi-parallel arrays of X-ray microbeams of 50-600 keV, produced by 2nd and 3rd generation synchrotron sources, such as the National Synchrotron Light Source (NSLS) in the U.S., and the European Synchrotron Radiation Facility (ESRF) in France, respectively. High dose rates are necessary to deliver therapeutic doses in microscopic volumes, to avoid spreading of the microbeams by cardiosynchronous movement of the tissues. A small beam divergence and a filtered white beam spectrum in the energy range between 30 and 250 keV results in the advantage of steep dose gradients with a sharper penumbra than that produced in conventional radiotherapy. MRT research over the past 20 years has allowed a vast number of results from preclinical trials on different animal models, including mice, rats, piglets and rabbits. Microbeams in the range between 10 and 100 micron width show an unprecedented sparing of normal radiosensitive tissues as well as preferential damage to malignant tumor tissues. Typically, MRT uses arrays of narrow ({approx}25-100 micron-wide) microplanar beams separated by wider (100-400 microns centre-to-centre, c-t-c) microplanar spaces. We note that thicker microbeams of 0.1-0.68 mm used by investigators at the NSLS are still called microbeams, although some invesigators in the community prefer to call them minibeams. This report, however, limits it discussion to 25-100 {mu}m microbeams. Peak entrance doses of several hundreds of Gy are surprisingly well tolerated by normal tissues. High resolution dosimetry has been developed over the last two decades, but typical dose ranges are adapted to dose delivery in conventional Radiation Therapy (RT). Spatial resolution in the sub-millimetric range has been achieved, which is currently required for quality assurance measurements in Gamma-knife RT. Most typical commercially available detectors are not suitable for MRT applications at a dose rate of 16000 Gy/s, micron resolution and a dose range over several orders of magnitude. This paper will give an overview of all dosimeters tested in the past at the ESRF with their advantages and drawbacks. These detectors comprise: Ionization chambers, Alanine Dosimeters, MOSFET detectors, Gafchromic registered films, Radiochromic polymers, TLDs, Polymer gels, Fluorescent Nuclear Track Detectors (Al{sub 2}O{sub 3}:C, Mg single crystal detectors), OSL detectors and Floating Gate-based dosimetry system. The aim of such a comparison shall help with a decision on which of these approaches is most suitable for high resolution dose measurements in MRT. The principle of these detectors will be presented including a comparison for some dosimeters exposed with the same irradiation geometry, namely a 1x1 cm{sup 5} field size with microbeam exposures at the surface, 0.1 cm and 1 cm in depth of a PMMA phantom. For these test exposures, the most relevant irradiation parameters for future clinical trials have been chosen: 50 micron FWHM and 400 micron c-t-c distance. The experimental data are compared with Monte Carlo calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diamond Photodetectors for X-Ray Absorption Spectroscopy Applications

Synchrotron radiation (SR) is a fundamental tool for X-ray research. In particular, X-ray absorption spectroscopy (XAS) accesses information as electronic properties, local structure or chemical-physical state in condensed-matter studies. Ionization chambers (ICs) are the most widely used XAS detectors for transmission measurements because of their reliability, high linearity and good stability. Recently, solid-state detectors have been considered and Si p-i-n has been applied to high fluxes (10{sup 11} ph/s), where the linearity of ICs is no longer guaranteed. Silicon photodiodes exhibit an extremely linear response in at least 5 decades but show diffraction peaks. Diamond is an ideal substrate to produce radiation-hard, low dark current (<1 pA/cm{sup 2}), visible-blind and fast-response X-ray detectors with a high S/N ratio. Diamond detectors were tested as SR monitor capable to withstand the high photon flux density of the 3{sup rd} generation SR sources. Being the lowest X-ray-absorbing solid-state dielectric material, diamond maximizes the flux through thin self-standing devices with minimal spectral effect down to the soft x-ray range. We will present results of X-ray tests of photoconductors based on different diamond substrates. The results will be compared to standard ICs for XAS applications in terms of spectral quality, noise and linearity in the 4-13 keV energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modernizing the Fission Basis (Experimental Progress Report)

In 2010 a proposal (Modernizing the Fission Basis) was prepared to 'resolve long standing differences between LANL and LLNL associated with the correct fission basis for analysis of nuclear test data'. Collaboration between LANL/LLNL/TUNL has been formed to implement this program by performing high precision measurements of neutron induced fission product yields as a function of incident neutron energy. This new program benefits from successful previous efforts utilizing mono-energetic neutrons undertaken by this collaboration. The first preliminary experiment in this new program was performed between July 24-31, 2011 at TUNL and had 2 main objectives: (1) demonstrating the capability to measure characteristic {gamma}-rays from specific fission products; (2) studying background effects from room scattered neutrons. In addition, a new dual fission ionization chamber has been designed and manufactured. The production design of the chamber is shown in the picture below. The first feasibility experiment to test this chamber is scheduled at the TUNL Tandem Laboratory from September 19-25, 2011. The dual fission chamber design will allow simultaneous exposure of absolute fission fragment emission rate detectors and the thick fission activation foils, positioned between the two chambers. This document formalizes the earlier experimental report demonstrating the experimental capability to make accurate (< 2 %) precision gamma-ray spectroscopic measurements of the excitation function of high fission product yields of the 239 Pu(n,f) reaction (induced by quasimonoenergetic neutrons). A second experiment (9/2011) introduced an compact double-sided fission chamber into the experimental arrangement, and so the relative number of incident neutrons striking the sample foil at each bombarding energy is limited only by statistics. (The number of incident neutrons often limits the experimental accuracy.) Fission chamber operation was so exceptional that 2 more chambers have been fabricated; thus fission foils of different isotopes may be left in place with sample changes. The scope of the measurements is both greatly expanded and the results become vetted. Experiment 2 is not reported here. A continuing experiment has been proposed for February 2012.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron-Induced Fission Cross Section Measurements for Uranium Isotopes and Other Actinides at LANSCE

A well established program of neutron-induced fission cross section measurement at Los Alamos Neutron Science Center (LANSCE) is supporting the Fuel Cycle Research program (FC R&D). The incident neutron energy range spans from sub-thermal up to 200 MeV by combining two LANSCE facilities, the Lujan Center and the Weapons Neutron Research center (WNR). The time-of-flight method is implemented to measure the incident neutron energy. A parallel-plate fission ionization chamber was used as a fission fragment detector. The event rate ratio between the investigated foil and a standard {sup 235}U foil is translated into a fission cross section ratio. Thin actinide targets with deposits of <200 {micro}g/cm{sup 2} on stainless steel backing were loaded into a fission chamber. In addition to previously measured data for {sup 237}Np, {sup 239-242}Pu, {sup 243}Am, new measurements include the recently completed {sup 233,238}U isotopes, {sup 236}U data which is being analyzed, and {sup 234}U data acquired in the 2011-2012 LANSCE run cycle. The new data complete the full suite of Uranium isotopes which were investigated with this experimental approach. When analysis of the new measured data is completed, data will be delivered to evaluators. Having data for multiple Uranium isotopes will support theoretical modeling capabilities and strengthens nuclear data evaluation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Photon beam quality variations of a flattening filter free linear accelerator

Purpose: Recently, there has been an increasing interest in operating conventional linear accelerators without a flattening filter. The aim of this study was to determine beam quality variations as a function of off-axis ray angle for unflattened beams. In addition, a comparison was made with the off-axis energy variation in flattened beams. Methods: Two Elekta Precise linear accelerators were modified in order to enable radiation delivery with and without the flattening filter in the beam line. At the Medical University Vienna (Vienna, Austria), half value layer (HVL) measurements were performed for 6 and 10 MV with an in-house developed device that can be easily mounted on the gantry. At St. Luke's Hospital (Dublin, Ireland), measurements were performed at 6 MV in narrow beam geometry with the gantry tilted around 270 deg. with pinhole collimators, an attenuator, and the chamber positioned on the table. All attenuation measurements were performed with ionization chambers and a buildup cap (2 mm brass) or a PMMA mini phantom (diameter 3 cm, measurement depth 2.5 cm). Results: For flattened 6 and 10 MV photon beams from the Elekta linac the relative HVL({theta}) varies by about 11% for an off-axis ray angle {theta}=10 deg. These results agree within {+-}2% with a previously proposed generic off-axis energy correction. For unflattened beams, the variation was less than 5% in the whole range of off-axis ray angles up to 10 deg. The difference in relative HVL data was less than 1% for unflattened beams at 6 and 10 MV. Conclusions: Off-axis energy variation is rather small in unflattened beams and less than half the one for flattened beams. Thus, ignoring the effect of off-axis energy variation for dose calculations in unflattened beams can be clinically justified.

43 PARTICLE ACCELERATORS↗

SU-E-T-346: Validation of Beam Accuracy of a Gated Spot-Scanning Proton Therapy System with Real-Time Tumor-Tracking at Hokkaido University

Purpose: At Hokkaido University, we have developed a gated spot scanning proton beam therapy system with real-time tumor-tracking under collaborative work with Hitachi Ltd. This system has the ability to gate proton beams from the synchrotron, turning the beam on only when the actual positions of inserted fiducial markers monitored by two fluoroscopic X-ray systems are within the planned positions [Shirato, 2012]. In this research, we validated the accuracy of the proton beams while utilizing external gating signals. Methods: The accuracy of spot positions, spot dose, absolute dose at the center of the SOBP, and range were measured while utilizing external gating signals. The following external gating signals were generated by an arbitrary waveform generator: (1) ON at all times (without gating), (2) an OFF period of 4 s followed by an ON period of 1 s, (3) two ON periods of 0.5 s with a 0.15 s OFF interval, (4) signals recorded during the treatment of real-time tumor-tracking X-ray therapy in Hokkaido University. The spot positions and spot dose were measured by beam monitors in the nozzle. The ranges were measured with a multi-layer ion chamber made by Hitachi Ltd. The absolute dose was measured with a Farmer ionization chamber and a RFA300 water phantom system. Results: The maximum error of the beam position in the isocenter plane was 0.8 mm without the gating signal and 1.0 mm with the gating signal. The maximum error of the spot dose was 0.0029 MU, below the criterion of 0.0032 MU. The maximum error of the absolute dose was 0.4% and the maximum variation of the range was 0.1 mm. Conclusion: It was confirmed with measurements of the beam that the accuracy of the proton beam met the criteria with external gating signals. This research was supported by the Cabinet Office, Government of Japan and the Japan Society for the Promotion of Science (JSPS) through the Funding Program for World-Leading Innovative R and D on Science and Technology (FIRST Program), initiated by the Council for Science and Technology Policy (CSTP)

60 APPLIED LIFE SCIENCES↗