Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERFEROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

The ATS-F interferometer - A precision wide field-of-view attitude sensor

An RF phase interferometer has been integrated into the ATS-F spacecraft attitude control system. Laboratory measurements indicate that the interferometer is capable of determining spacecraft attitude in pitch and roll to an accuracy of 0.18 deg over a field-of-view of plus or minus 12.5 deg about the spacecraft normal axis with an angular resolution of 0.004 deg. The system is completely solid state, weighs 17 pounds, and consumes 12.5 W of DC power.

Teichman, M. A.↗

Zone plate interferometer

A developed form of the Fresner zone-plate interferometer is described. Three basic configurations are distinguished, associated with the real and virtual first order foci of a zone plate. Related versions and higher order variants are also educed. Compensated phase zone plates used in this application are found to produce uniform amplitude wavefronts. The properties of the interferometer in this form are discussed and an example given of its high-quality performance.

Smartt, R. N.↗

Development of a spectroscopic photoelectric imaging Fabry-Perot interferometer preliminary observational results

In order to observe extended astronomical objects at high spatial and spectral resolution, a spectroscopic photoelectric imaging Fabry-Perot interferometer was constructed. Among the properties chosen for the instrument are an air-spaced, piezoelectrically scanned design allowing an accurately settable free spectral range and employing a single etalon of high finesse. Careful design of the etalon mountings and optical train preserves high ligh throughput. Spectra of single spatial elements with a photomultiplier were obtained, and an SEC vidicon detector was used to record a series of images through the interferometer while scanning the wavelength in discrete steps. The latter procedure yields sufficient information to reconstruct spectral features over the entire object, and for the conditions assumed, either series of observations requires only a small fraction of a rotational period for Jupiter or Saturn. An electronic control system was also constructed which permits rapid and flexible variation of the operational mode of the Fabry-Perot and its ancilliary devices so as to minimize loss of observational time.

Smith, W. H.↗

The structure of radio sources 3C 273B and 3C 84 deduced from the 'closure' phases and visibility amplitudes observed with three-element interferometers

The derived 'closure' phase relation for a three-element interferometer is used in a presented analysis of data obtained from observations at 7.8 GHz of the radio sources 3C 273B and 3C 84 by antennas in Massachusetts, California, Alaska, and Sweden (the first two antennas were used in combination with each of the last two separately to form two three-element interferometers). The brightness distribution is found for each source by expansion of both the fringe amplitude and the fringe phase in separate Fourier series.

Rogers, A. E. E.↗

Spectroscopic photoelectric imaging Fabry-Perot interferometer - Its development and preliminary observational results

In order to observe extended astronomical objects at high spatial and spectral resolution, we have constructed a spectroscopic photoelectric imaging Fabry-Perot interferometer (SPIFI). Among the properties chosen for the instrument are an air-spaced, piezoelectrically scanned design allowing an accurately settable free spectral range and employing a single etalon of high finesse. Careful design of the etalon mountings and optical train preserves high light throughput. We either obtain spectra of single spatial elements with a photomultiplier or use an SEC vidicon detector to record a series of images through the interferometer while scanning the wavelength in discrete steps. The latter procedure yields sufficient information to reconstruct spectral features over the entire object. For the conditions assumed, either series of observations requires only a small fraction of a rotational period for Jupiter or Saturn, for example.

Smith, W. H.↗

A very-long-baseline interferometer system for geodetic applications

A very-long-baseline interferometer system was designed and built for geodetic applications. Each interferometer terminal records a 360-kHz spectral band of noise from a compact extragalactic radio source. The center frequency of the spectral band can be selected to sample sequentially bands covering a much wider frequency range to obtain subnanosecond accuracy in group-delay measurements. A tunnel-diode pulse generator is used to calibrate the delays in the receiver. The necessary sets of algorithms and computer programs have been developed to analyze the data and have allowed the system to be employed to make accurate determinations of vector baselines, radio-source positions, polar motion, and universal time.

Whitney, A. R.↗

Optical fiber waveguide sagnac interferometer. Phase 1: Multiturn one meter diameter, single mode

A rotating ring interferometer was constructed using a 100 meters of single mode optical fiber wound on a crystal cylinder. A 20 inch diameter fiber interferometer gyroscope was built and its sensitivity was evaluated. Major noise sources were identified and improvements for the next phase of development were determined. The accuracy of .01 of a fringe can be improved to .0001 by the removal of the noise source.

Vali, V.↗

Interferometer mirror tilt correcting system

An interferometer is described, having several means for automatically adjusting the angular tilt of a reflecting surface in one of two paths to maintain the exit beams from the two paths parallel to each other. Three detectors at the output of the interferometer were disposed on mutually perpendicular axes which define a plane normal to the nominal exit beam axis. One detector at the origin of the axes was used as a reference for separate phase difference comparison with the outputs of the other two detectors on the X and Y axes to develop servo error signals.

Schindler, R. A.↗

Computer control of a far infrared interferometer

A simple interface has been designed for the automatic control and data collection from a Grubb Parsons Mark III cube interferometer. A computer is used to automatically step the movable mirror on the interferometer. Data may be directly input into the computer for immediate transformation or stored for later analysis via a fast Fourier transformation. The interface is based on a commercial analog-to-digital converter having a parallel-to-serial data converter. The device can also display ASCII characters sent from the computer in parallel binary code. The system is applicable to recording interferograms having long time durations and to measuring multiple interferograms for statistical averaging.

Breecher, J.↗

A white-light amplitude interferometer with 180-degree rotational shear

The paper reports on the fabrication, alignment, and test techniques of an equal-path, wave-front, folding amplitude interferometer with 180-degree rotational shear. The device may be used for measuring atmospheric phase-perturbing properties and designing optical filters used in processing spatial information. The instrument has been used to photograph the Michelson Stellar interferometer fringes.

Breckinridge, J. B.↗

A chevron beam-splitter interferometer

Fully tilt compensated double-pass chevron beam splitter, that removes channelling effects and permits optical phase tuning, is wavelength independent and allows small errors in alignment that are not tolerated in Michelson, Machzender, or Sagnac interferometers. Device is very useful in experiments where background vibration affects conventional interferometers.

Breckinridge, J. B.↗

Exposure time for space-borne IR spatial interferometer

A mathematical analysis is performed to determine the relationship between the signal-to-noise ratio and the exposure time for an orbiting IR heterodyne spatial interferometer. The analysis includes consideration of the transformation of the interferogram to obtain the source angular intensity distribution so that the signal-to-noise ratio pertains to the angular distribution rather than to the interferogram. The analysis is applied to a number of known IR sources. The results presented show that an interferometer with a 30-m baseline using half-meter telescopes should be able to image a source such as IRC + 30219 with a signal-to-noise ratio of 10 in a total exposure time of less than an hour.

Wolfe, R. H., Jr.↗

A two-dimensional white-light amplitude interferometer

A review of the applications of a point-symmetric, 180-degree, rotational shearing interferometer is given. Material includes, photographs of the Michelson stellar interferometer fringes from Alpha-Lyr, measures of amplitude of phase excursions in the atmosphere, and a measure of the order of interference of speckle patterns. New material includes unpublished double star speckle patterns to illustrate the isoplanatic patch, a measure of the time fluctuations in the earth's atmosphere, and measurements of the properties of a 256 channel linear reticon.

Breckinridge, J. B.↗

The Tidbinbilla interferometer

A proposal to operate a two element interferometer using the 64 m and 26 m antennas of the Tidbinbilla Deep Space Station is discussed. The instrument is to be operated as a correlation interferometer, the sine and cosine products being sampled once per second and recorded for later analysis. The receiver systems are currently under development. Preliminary measurements of the delay line and local oscillator systems and the site cables suggest that a phase stability to within about 1 deg should be achievable with temperature control of the receiver packages.

Batty, M. J.↗

Accurate radio positions with the Tidbinbilla interferometer

The Tidbinbilla interferometer (Batty et al., 1977) is designed specifically to provide accurate radio position measurements of compact radio sources in the Southern Hemisphere with high sensitivity. The interferometer uses the 26-m and 64-m antennas of the Deep Space Network at Tidbinbilla, near Canberra. The two antennas are separated by 200 m on a north-south baseline. By utilizing the existing antennas and the low-noise traveling-wave masers at 2.29 GHz, it has been possible to produce a high-sensitivity instrument with a minimum of capital expenditure. The north-south baseline ensures that a good range of UV coverage is obtained, so that sources lying in the declination range between about -80 and +30 deg may be observed with nearly orthogonal projected baselines of no less than about 1000 lambda. The instrument also provides high-accuracy flux density measurements for compact radio sources.

Batty, M. J.↗

Interferometer

An interferometer of relatively simple design which is tilt compensated, and which facilitates adjustment of the path lengths of split light beams is described. The interferometer includes a pair of plate-like elements with a dielectric coating and an oil film between them, that forms a beamsplitter interface, and with a pair of reflector surfaces at the ends of the plates. A pair of retroreflectors are positioned so that each split beam component is directed by a retroreflector onto one of the reflector surfaces and is then returned to the beamsplitter interface, so that the reflector surfaces tilt in a direction and amount that compensates for tilting of the beamsplitter interface.

Breckinridge, J. B.↗

Near-infrared spectral imaging Michelson interferometer for astronomical applications

The design and operation of an imaging Michelson interferometer-spectrometer used for near-infrared (0.8 micron to 2.5 microns) spectral imaging are reported. The system employs a rapid scan interferometer modified for stable low resolution (250/cm) performance and a 42 element PbS linear detector array. A microcomputer system is described which provides data acquisition, coadding, and Fourier transformation for near real-time presentation of the spectra of all 42 scene elements. The electronic and mechanical designs are discussed and telescope performance data presented.

Wells, C. W.↗

DC calibration of the strain sensitivity of a single mode optical fiber interferometer

The strain sensitivity of an optical fiber interferometer developed for the detection of pulsed ultrasonic waves in solids has been calibrated. The optical paths in both signal and reference arms of the interferometer are through similar 2 m lengths of ITT-110 single mode fibers mode stripped by index matching at both ends and attached to opposite sides of a 30 cm plexiglas bar 0.3 cm thick. Light from the output ends of both fibers was superimposed to form an interference fringe pattern that was interrogated in the far field to give a signal proportional to the differential optical fiber path length. Strain sensitivity was determined by comparing data obtained by clamping and bending the bar at different lengths to simple cantilever beam theory. Calibration indicates a minimum theoretical detectable strain of less than 10 to the -10.

Claus, R. O.↗