Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTEGRAL DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

1985 Annual Conference on Nuclear and Space Radiation Effects, 22nd, Monterey, CA, July 22-24, 1985, Proceedings

Basic mechanisms of radiation effects in structures and materials are discussed, taking into account the time dependence of interface state production, process dependent build-up of interface states in irradiated N-channel MOSFETs, bias annealing of radiation and bias induced positive charges in n- and p-type MOS capacitors, hole removal in thin-gate MOSFETs by tunneling, and activation energies of oxide charge recovery in SOS or SOI structures after an ionizing pulse. Other topics investigated are related to radiation effects in devices, radiation effects in integrated circuits, spacecraft charging and space radiation effects, single-event phenomena, hardness assurance and radiation sources, SGEMP/IEMP phenomena, EMP phenomena, and dosimetry and energy-dependent effects. Attention is given to a model of the plasma wake generated by a large object, gate charge collection and induced drain current in GaAs FETs, simulation of charge collection in a multilayer device, and time dependent dose enhancement effects on integrated circuit transient response mechanisms.

Jones, C. W.↗

SU-E-J-137: Incorporating Tumor Regression Into Robust Plan Optimization for Head and Neck Radiotherapy

Purpose: To develop a robust planning paradigm which incorporates a tumor regression model into the optimization process to ensure tumor coverage in head and neck radiotherapy. Methods: Simulation and weekly MR images were acquired for a group of head and neck patients to characterize tumor regression during radiotherapy. For each patient, the tumor and parotid glands were segmented on the MR images and the weekly changes were formulated with an affine transformation, where morphological shrinkage and positional changes are modeled by a scaling factor, and centroid shifts, respectively. The tumor and parotid contours were also transferred to the planning CT via rigid registration. To perform the robust planning, weekly predicted PTV and parotid structures were created by transforming the corresponding simulation structures according to the weekly affine transformation matrix averaged over patients other than him/herself. Next, robust PTV and parotid structures were generated as the union of the simulation and weekly prediction contours. In the subsequent robust optimization process, attainment of the clinical dose objectives was required for the robust PTV and parotids, as well as other organs at risk (OAR). The resulting robust plans were evaluated by looking at the weekly and total accumulated dose to the actual weekly PTV and parotid structures. The robust plan was compared with the original plan based on the planning CT to determine its potential clinical benefit. Results: For four patients, the average weekly change to tumor volume and position was −4% and 1.2 mm laterally-posteriorly. Due to these temporal changes, the robust plans resulted in an accumulated PTV D95 that was, on average, 2.7 Gy higher than the plan created from the planning CT. OAR doses were similar. Conclusion: Integration of a tumor regression model into target delineation and plan robust optimization is feasible and may yield improved tumor coverage. Part of this research is supported by Varian Medical System.

60 APPLIED LIFE SCIENCES↗

SU-D-16A-03: A Radiation Pneumonitis Dose-Response Model Incorporating Non- Local Radiation-Induced Bystander Effect

Purpose: Dose-response models that can reliably predict radiation pneumonitis (RP) to guide radiation therapy (RT) for lung cancer presently do not exist. A model is proposed that incorporates non-local radiationinduced bystander effect (RIBE). Methods: A single sigmoid response function, derived from published data for whole lung irradiation, relates RP probability to cumulative lung damage, regardless of fractionation scheme. Lung damage is assumed to be caused by direct local radiation damage, quantified via the linear-quadratic (LQ) model, and RIBE. Based on published data, RIBE is assumed to be activated when per-fraction dose rises above ∼0.6 Gy, but is constant with dose above that threshold. Integral RIBE damage is assumed proportional to lung volume irradiated above ∼0.6 Gy per fraction. Key model parameters include LQ α and β, and two RIBE parameters: the single-fraction probability δ of damage, and a proportionality parameter κ that relates the potential for RIBE damage to irradiated lung volume. All parameters are tentatively fitted from published data, the RIBE parameters from published RP rates for conventionally fractionated RT (CFRT) and stereotactic body RT (SBRT). Results: The model predicts dose-response curves that are consistent with clinical experience. It provides a tentative explanation for why V20 (33 fractions), V13 (20 fractions) and V5 (<10 fractions) are observed to be correlated with RP. It also provides a plausible explanation for the success of SBRT — RIBE damage increases with the number of fractions, so penalizes CFRT relative to SBRT. Conclusion: The proposed model is relatively simple, extrapolates from published data, plausibly explains several clinical observations, and produces dose-response curves that are consistent with clinical experience. While capable of elaboration, its ability to explain doseresponse experience with different fractionation schemes using a small number of assumptions and parameters is an advantage.

60 APPLIED LIFE SCIENCES↗

Use of Automation in Low Level Waste Storage and Management - 19227

The Australian Nuclear Science and Technology Organisation (ANSTO) generates Low Level Waste (LLW) and Intermediate Level Waste (ILW) from various site operations such as the operation of a research Reactor and the manufacture of Molybdenum 99. The Low Level Solid Waste (LLSW) generated is stored at ANSTO before and after conditioning. The current process flow involves the storage of LLSW waste before conditioning on racks, handled using forklifts. When the unconditioned waste is ready for conditioning, it is transferred to another facility, where volume reduction and packaging is carried out. Once conditioned, the waste is placed in further storage, pending dispatch to the proposed Australian National Radioactive Waste Management Facility (NRWMF). A new purpose built facility has been constructed, adjacent to the LLSW processing facility, for the storage and management of LLSW in both unconditioned and conditioned forms. This new facility will streamline the waste management process and significantly enhance the safety and efficiency of the process. In line with international best practises, the new facility utilises automation solutions to minimise the build footprint, and minimise the use of forklifts and other mobile plant. Most importantly, it applies the principle of ALARA (As Low as Reasonably Achievable) to minimise operator activities in areas where radioactive material is stored and eliminates double handling of the waste. The automation for unconditioned waste utilises an Automated Storage and Retrieval System (ASRS), a vertical stacker crane within high density racking, to provide easy storage and retrieval for processing and/or routine inspections. This system allows operators to control it from outside of the storage area whilst utilising integrated software that allows for the required tracking of the unconditioned waste. From the ASRS storage area, unconditioned waste will have a smooth transition to the processing facility which is located adjacent to the ASRS system. Once conditioned, the waste is catalogued and returned to a designated storage area within the new facility using an automated building gantry crane with a target delivery system to eliminate the need for operators in the main storage bay. The waste will be held here in preparation for dispatch to the future repository. The utilisation of the ASRS for the purpose of storing LLSW is an innovative use of automation that will eliminate operators from active areas, reduce dose rates received and integrate with the waste tracking software. Furthermore, the system has significant advantages with operational efficiencies increased, reduced double handling of nuclear waste and maximum use of building footprint. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dose Rate Effects in Linear Bipolar Transistors

Dose rate effects are examined in linear bipolar transistors at high and low dose rates. At high dose rates, approximately 50% of the damage anneals at room temperature, even though these devices exhibit enhanced damage at low dose rate. The unexpected recovery of a significant fraction of the damage after tests at high dose rate requires changes in existing test standards. Tests at low temperature with a one-second radiation pulse width show that damage continues to increase for more than 3000 seconds afterward, consistent with predictions of the CTRW model for oxides with a thickness of 700 nm.

linear integrated circuit↗

Quantification of Proton Dose Calculation Accuracy in the Lung

Purpose: To quantify the accuracy of a clinical proton treatment planning system (TPS) as well as Monte Carlo (MC)–based dose calculation through measurements and to assess the clinical impact in a cohort of patients with tumors located in the lung. Methods and Materials: A lung phantom and ion chamber array were used to measure the dose to a plane through a tumor embedded in the lung, and to determine the distal fall-off of the proton beam. Results were compared with TPS and MC calculations. Dose distributions in 19 patients (54 fields total) were simulated using MC and compared to the TPS algorithm. Results: MC increased dose calculation accuracy in lung tissue compared with the TPS and reproduced dose measurements in the target to within ±2%. The average difference between measured and predicted dose in a plane through the center of the target was 5.6% for the TPS and 1.6% for MC. MC recalculations in patients showed a mean dose to the clinical target volume on average 3.4% lower than the TPS, exceeding 5% for small fields. For large tumors, MC also predicted consistently higher V5 and V10 to the normal lung, because of a wider lateral penumbra, which was also observed experimentally. Critical structures located distal to the target could show large deviations, although this effect was highly patient specific. Range measurements showed that MC can reduce range uncertainty by a factor of ∼2: the average (maximum) difference to the measured range was 3.9 mm (7.5 mm) for MC and 7 mm (17 mm) for the TPS in lung tissue. Conclusion: Integration of Monte Carlo dose calculation techniques into the clinic would improve treatment quality in proton therapy for lung cancer by avoiding systematic overestimation of target dose and underestimation of dose to normal lung. In addition, the ability to confidently reduce range margins would benefit all patients by potentially lowering toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-BRD-04: Development of a Secondary MU Calculation Tool for An Integrated MR-LINAC

Purpose: To develop a fast secondary MU calculation tool for an integrated MR-Linac, an emerging technology for delivering image-guided on-line adaptive therapy. Methods: A software tool was developed to implement a modified Clarkson integration algorithm for point-dose calculation, considering the dosimtric effect of a magnetic field. A research planning system, considering the presence of a perpendicular 1.5 T magnetic field, was used to extract the beam data (e.g., depth doses and beam profiles) required for the MU calculation in homogeneous phantom of 60×60×40 cm3 for a prototype of MR-Linac integrating a 1.5 T MR scanner with 6MV photon beams. These dosimetric data may be replaced with those to be collected during the commissioning measurement of the MR-Linac. Results: The presence of the magnetic field resulted in noticeable changes including (1) shifts in beam profiles for small fields (< 2×2 cm2), and (2) changes in central-axis doses when one of field edges is < 2 cm away from the central axis. For example, the maximum change in central-axis dose was up to 8% for one of the field borders with a distance away from the central axis of <1 cm. These changes are relevant for the MU calculation particularly for IMRT and VMAT, where most of segments are small. These magnetic field affected beam profiles and depth doses were included in the software tool. The MU calculations from the software tool for selective representative plans were found to agree with those from the research planning system within 10%. Conclusion: The presence of a perpendicular magnetic field results in noticeable changes in beam profiles and depth doses for small fields. These changes are included in the secondary MU calc{sup 33}u{sup 3}lation to be used as a redundancy check for an integrated MR-Linac.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Australasian Gastrointestinal Trials Group (AGITG) Contouring Atlas and Planning Guidelines for Intensity-Modulated Radiotherapy in Anal Cancer

Purpose: To develop a high-resolution target volume atlas with intensity-modulated radiotherapy (IMRT) planning guidelines for the conformal treatment of anal cancer. Methods and Materials: A draft contouring atlas and planning guidelines for anal cancer IMRT were prepared at the Australasian Gastrointestinal Trials Group (AGITG) annual meeting in September 2010. An expert panel of radiation oncologists contoured an anal cancer case to generate discussion on recommendations regarding target definition for gross disease, elective nodal volumes, and organs at risk (OARs). Clinical target volume (CTV) and planning target volume (PTV) margins, dose fractionation, and other IMRT-specific issues were also addressed. A steering committee produced the final consensus guidelines. Results: Detailed contouring and planning guidelines and a high-resolution atlas are provided. Gross tumor and elective target volumes are described and pictorially depicted. All elective regions should be routinely contoured for all disease stages, with the possible exception of the inguinal and high pelvic nodes for select, early-stage T1N0. A 20-mm CTV margin for the primary, 10- to 20-mm CTV margin for involved nodes and a 7-mm CTV margin for the elective pelvic nodal groups are recommended, while respecting anatomical boundaries. A 5- to 10-mm PTV margin is suggested. When using a simultaneous integrated boost technique, a dose of 54 Gy in 30 fractions to gross disease and 45 Gy to elective nodes with chemotherapy is appropriate. Guidelines are provided for OAR delineation. Conclusion: These consensus planning guidelines and high-resolution atlas complement the existing Radiation Therapy Oncology Group (RTOG) elective nodal ano-rectal atlas and provide additional anatomic, clinical, and technical instructions to guide radiation oncologists in the planning and delivery of IMRT for anal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-CD-304-01: FEATURED PRESENTATION and BEST IN PHYSICS (THERAPY): Trajectory Modulated Arc Therapy: Development of Novel Arc Delivery Techniques Integrating Dynamic Table Motion for Extended Volume Treatments

Purpose: Integration of coordinated robotic table motion with inversely-planned arc delivery has the potential to resolve table-top delivery limitations of large-field treatments such as Total Body Irradiation (TBI), Total Lymphoid Irradiation (TLI), and Cranial-Spinal Irradiation (CSI). We formulate the foundation for Trajectory Modulated Arc Therapy (TMAT), and using Varian Developer Mode capabilities, experimentally investigate its practical implementation for such techniques. Methods: A MATLAB algorithm was developed for inverse planning optimization of the table motion, MLC positions, and gantry motion under extended-SSD geometry. To maximize the effective field size, delivery trajectories for TMAT TBI were formed with the table rotated at 270° IEC and dropped vertically to 152.5cm SSD. Preliminary testing of algorithm parameters was done through retrospective planning analysis. Robotic delivery was programmed using custom XML scripting on the TrueBeam Developer Mode platform. Final dose was calculated using the Eclipse AAA algorithm. Initial verification of delivery accuracy was measured using OSLDs on a solid water phantom of varying thickness. Results: A comparison of DVH curves demonstrated that dynamic couch motion irradiation was sufficiently approximated by static control points spaced in intervals of less than 2cm. Optimized MLC motion decreased the average lung dose to 68.5% of the prescription dose. The programmed irradiation integrating coordinated table motion was deliverable on a TrueBeam STx linac in 6.7 min. With the couch translating under an open 10cmx20cm field angled at 10°, OSLD measurements along the midline of a solid water phantom at depths of 3, 5, and 9cm were within 3% of the TPS AAA algorithm with an average deviation of 1.2%. Conclusion: A treatment planning and delivery system for Trajectory Modulated Arc Therapy of extended volumes has been established and experimentally demonstrated for TBI. Extension to other treatment techniques such as TLI and CSI is readily achievable through the developed platform. Grant Funding by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-E-T-29: A Dosimetric Study of Volumetric Modulated Arc Therapy with Simultaneous Integrated Boost for Rectal Cancer

Purpose: To compare the dosimetric differences among fixed field intensity-modulated radiotherapy (IMRT) and double-arc volumetricmodulated arc therapy (VMAT) plans with simultaneous integrated boost in rectal cancer. Methods: Ten patients with rectal cancer previously treated with IMRT were included in this analysis. For each patient, two treatment techniques were designed for each patient: the fixed 7 fields IMRT and double-arc VMAT with RapidArc technique. The treatment plan was designed to deliver in one process with simultaneous integrated boost (SIB). The prescribed doses to the planning target volume of the subclinical disease (PTV1) and the gross disease (PTV2) were 45 Gy and 55 Gy in 25 fractions, respectively. The dose distribution in the target, the dose to the organs at risk, total MU and the delivery time in two techniques were compared to explore the dosimetric differences. Results: For the target dose and homogeneity in PTV1 and PTV2, no statistically differences were observed in the two plans. VMAT plans showed a better conformity in PTV1. VMAT plans reduced the mean dose to bladder, small bowel, femur heads and iliac wings. For iliac wings, VMAT plans resulted in a statistically significant reduction in irradiated volume of 15 Gy, 20 Gy, 30 Gy but increased the 10 Gy irradiated volume. VMAT plans reduced the small bowel irradiated volume of 20 Gy and 30 Gy. Compared with IMRT plans, VMAT plans showed a significant reduction of monitor units by nearly 30% and reduced treatment time by an average of 70% Conclusion: Compared to IMRT plans, VMAT plans showed the similar target dose and reduced the dose of the organs at risk, especially for small bowel and iliac wings. For rectal cancer, VMAT with simultaneous integrated boost can be carried out with high quality and efficiency.

60 APPLIED LIFE SCIENCES↗

Application of the GBFP Method to Electron Partial-Wave Expansion Elastic Scattering Differential Cross Sections Within the Geant4 Toolkit - Paper 69

Analog Monte Carlo simulation of electrons in complex material geometries is generally impractical because the long range Coulomb interactions result in highly peaked differential cross sections (DCS) for scattering and energy-loss and extremely small collision mean free paths (mfp). The condensed history (CH) Monte Carlo method attempts to alleviate this limitation by advancing electrons in fixed steps and sampling angular deflections and energy losses from precomputed distributions obtained from approximate solutions to the underlying transport equation that are valid only for thin layers. Though CH is efficient and is widely employed in production codes (ITS, MCNP, EGS, Geant), step size restrictions and inconsistent handling of material and free surface boundaries limit the ultimate accuracy possible with this approach, especially in applications to highly heterogeneous media. Recently proposed alternatives to the CH method, such as the Generalized Boltzmann Fokker-Planck (GBFP) method, restore the correct transport mechanics by simulating single events based on a Boltzmann transport equation but with efficiency and accuracy achieved through the use of reduced-physics interaction models. Motivated by Lewis theory, various moment-preserving strategies are employed in the GBFP approach to construct DCSs that are less singular, and with mfps shorter than analog. Specifically, the approximate cross sections are constructed to rigorously preserve a finite number of angular and energy-loss moments of the analog DCSs while all higher moments are approximated in terms of the exact lower moments. By systematically increasing the number of moments retained, any desired accuracy can be obtained for integrated quantities, such as dose, reflection and transmission yields, as well as distributed quantities such as energy and angular distributions. For relativistic Rutherford cross section models, the GBFP method has been demonstrated in Monte Carlo simulation to yield accuracy comparable to analog but at a fraction of the cost. One advantage of the GBFP approach is that angular deflection and energy-loss interactions depend only on Legendre moments and energy-loss moments and not the detailed form of the analog DCSs. This feature allows moment-preservation to be enforced through DCSs expressed as a superposition of discrete (i.e., using delta-functions) angular deflections and discrete energy losses. This promotes extremely efficient computation when compared to analog and completely continuous or hybrid discrete-continuous moment-based DCS reconstructions, while yielding highly accurate results for integrated and distributed quantities. In this paper, we demonstrate that the moment-preserving algorithms central to our fully discrete GBFP method can be readily extended to apply to tabulated DCS data, specifically to the partial-wave expansion (PWE) elastic scattering DCSs. Since data libraries for the PWE DCSs for energy and material combinations of interest can be prohibitively large, the GBFP method provides a means to reduce data storage requirements. We implemented our algorithm in the Geant4 Monte Carlo code and all numerical results are obtained using this implementation. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

ITAR: A modified TAR method to determine depth dose distribution for an ophthalmic device that performs kilovoltage x-ray pencil-beam stereotaxy

Purpose: New technology has been developed to treat age-related macular degeneration (AMD) using 100 kVp pencil-beams that enter the patient through the radio-resistant sclera with a depth of interest between 1.6 and 2.6 cm. Measurement of reference and relative dose in a kilovoltage x-ray beam with a 0.42 cm diameter field size and a 15 cm source to axis distance (SAD) is a challenge that is not fully addressed in current guidelines to medical physicists. AAPM's TG-61 gives dosimetry recommendations for low and medium energy x-rays, but not all of them are feasible to follow for this modality. Methods: An investigation was conducted to select appropriate equipment for the application. PTW's Type 34013 Soft X-Ray Chamber (Freiburg, Germany) and CIRS's Plastic Water LR (Norfolk, VA) were found to be the best available options. Attenuation curves were measured with minimal scatter contribution and thus called Low Scatter Tissue Air Ratio (LSTAR). A scatter conversion coefficient (C{sub scat}) was derived through Monte Carlo radiation transport simulation using MCNPX (LANL, Los Alamos, NM) to quantify the difference between a traditional TAR curve and the LSTAR curve. A material conversion coefficient (C{sub mat}) was determined through experimentation to evaluate the difference in attenuation properties between water and Plastic Water LR. Validity of performing direct dosimetry measurements with a source to detector distance other than the treatment distance, and therefore a different field size due to a fixed collimator, was explored. A method—Integrated Tissue Air Ratio (ITAR)—has been developed that isolates each of the three main radiological effects (distance from source, attenuation, and scatter) during measurement, and integrates them to determine the dose rate to the macula during treatment. Results: LSTAR curves were determined to be field size independent within the range explored, indicating that direct dosimetry measurements may be performed with a source to detector distance of 20 cm even though the SAD is 15 cm during treatment. C{sub scat} varied from 1.102 to 1.106 within the range of depths of interest. The experimental variance among repeated measurements of C{sub mat} was larger than depth dependence, so C{sub mat} was estimated as1.019 for all depths of interest. Conclusions: Equipment selection, measurement techniques, and formalism for the determination of dose rate to the macula during stereotaxy for AMD have been determined and are strongly recommended by the authors of this paper to be used by clinical medical physicists.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-FG-207B-07: Feasibility of Low Dose Lung Cancer Screening with a Whole-Body Photon Counting CT: First Human Results

Purpose: To evaluate the feasibility of using a whole-body photon counting detector (PCD) CT scanner for low dose lung cancer screening compared to a conventional energy integrating detector (EID) system. Methods: Radiation dose-matched EID and PCD scans of the COPDGene 2 phantom and 2 human volunteers were acquired. Phantom images were acquired at different radiation dose levels (CTDIvol: 3.0, 1.5, and 0.75 mGy) and different tube voltages (120, 100, and 80 kVp), while human images were acquired at vendor recommended low-dose lung cancer screening settings. EID and PCD images were compared for quantitative Hounsfield unit accuracy, noise levels, and contrast-to-noise ratios (CNR) for detection of ground-glass nodules (GGNs) and emphysema. Results: The PCD Hounsfield unit accuracy was better for water at all scan parameters, and for lung, GGN and emphysema equivalent regions of interest (ROIs) at 1.5 and 0.75 mGy. PCD attenuation accuracy was more consistent for all scan parameters (all P<0.01), while Hounsfield units for lung, GGN and emphysema ROIs changed significantly for EID with decreasing dose (all P<0.001). PCD showed lower noise levels at the lowest dose setting at 120, 100 and 80 kVp (15.2±0.3 vs 15.8±0.2, P=0.03; 16.1±0.3 vs 18.0±0.4, P=0.003; and 16.1±0.3 vs 17.9±0.3, P=0.001, respectively), resulting in superior CNR for the detection of GGNs and emphysema at 100 and 80 kVp. Significantly lower PCD noise levels were confirmed in volunteer images. Conclusion: PCD provided better Hounsfield unit accuracy for lung, ground-glass, and emphysema-equivalent foams at 1.5 and 0.75 mGy with less variability than EID. Additionally, PCD showed less noise, and higher CNR at 0.75 mGy for both 100 and 80 kVp. PCD technology may help reduce radiation exposure in lung cancer screening while maintaining diagnostic quality.

60 APPLIED LIFE SCIENCES↗

Integrating Large Scale Data Sets to Develop Predictive Hypotheses of Low-Dose Radiation-Induced Health Effects

Over one hundred years of radiation biology research has revealed much about the DNA damages induced by the deposition of energy from exposure to ionizing radiation and the subsequent cellular responses. However, there are still significant gaps in our understanding of how these might lead to detrimental health effects, particularly at low doses (100 mGy (milligray)). Recent advances in high throughput omics technologies enable interrogation of induced radiation effects at the genomic, proteomic and metabolomic levels. These include changes in gene expression, protein modifications, e.g., phosphorylation, acetylation, and methylation, and metabolic changes. We will discuss the integration of data obtained from multiple omics platforms to understand radiation dose, and dose rate effects in a complex human tissue model as a function of time. We will use as an example our results on the low dose responses in a 3D human skin model.

ionizing radiation↗

Russian-Norwegian Cooperation In Regulation of the Public Radiation Protection in the Northwest Russia - 12440

In 1960's, the large technical bases of the Northern Fleet were arranged on the Kola Peninsula. These bases were involved in support of nuclear submarines performing acceptance and storage of radioactive waste (RW) and spent nuclear fuel (SNF). Since 1985, the waste acceptance has been stopped and the technical bases changed their functions to serve as sites of temporary storage (STS). According to the RF Government Directive of 09 February 2000 No 220-r, the STS were put under Rosatom responsibility in order to conduct operations dealing with the SNF and RW management being accumulated during the naval activity and originated from dismantlement of nuclear submarines and surface ships equipped with nuclear powered installations, as well as to carry out environmental remediation of radiation hazardous facilities in this region. The international collaborative assistance is very important to increase effectiveness of such works. This paper includes the findings of cooperation between the Federal Medical Biological Agency (FMBA) and Norwegian Radiation Protection Authority (NRPA) in radiation protection of the public in the course of the STS remediation. Since 2004, the following works has been carried out in this direction: - radiation threat assessment and identification of the priority directions of radiation and hygienic studies; - radiation situation inspections on-site and within the coastal offshore waters at different stage of remediation; - development of the documents including the criteria for the STS remediation and guidelines for radiation monitoring to control the mentioned criteria compliance; - development of the radio-ecological geo-information system. The developed criteria consider four basic options of the STS remediation - renovation, conversion, conservation and liquidation. The main (dose) and derived remediation levels have been determined for each option. The resulted from monitoring radiation parameters - including contents of {sup 137}Cs, {sup 90}Sr and {sup 60}Co in samples of soil, vegetation, seawater, seaweeds, bottom sediments, invertebrates and vertebrates, gamma dose rate values - are integrated in the database, which is the component of the geo-information system. The developed regulative and methodical documents and the geo-information system have been introduced in Regional Management-120 under FMBA of Russia, which is responsible for the radiation safety supervision, Centre of Hygiene and Epidemiology-120 under FMBA of Russia, which carries out regulatory radiation control, and in the operating organization involved in the STS remediation and responsible for radiation protection of workers and public. The works completed have permitted to solve the majority of problems in enhancement of radiation and hygienic supervision of SevRAO operation. However, some relevant questions in this area need additional efforts. In particular, in the course of specification of the design solutions, obtaining additional data on the radiation situation parameters and clarification of the prognostic assessments, the necessity will certainly arise to amend the regulatory documents taking the adopted design solutions into account. We are on the way to real results. Much has been done for the first time, and although it is difficult to foresee all future problems and challenges, our knowledge, experience and close cooperation permit to assess the prospects confidently. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dual ring multilayer ionization chamber and theory-based correction technique for scanning proton therapy

Purpose: To develop a multilayer ionization chamber (MLIC) and a correction technique that suppresses differences between the MLIC and water phantom measurements in order to achieve fast and accurate depth dose measurements in pencil beam scanning proton therapy. Methods: The authors distinguish between a calibration procedure and an additional correction: 1—the calibration for variations in the air gap thickness and the electrometer gains is addressed without involving measurements in water; 2—the correction is addressed to suppress the difference between depth dose profiles in water and in the MLIC materials due to the nuclear interaction cross sections by a semiempirical model tuned by using measurements in water. In the correction technique, raw MLIC data are obtained for each energy layer and integrated after multiplying them by the correction factor because the correction factor depends on incident energy. The MLIC described here has been designed especially for pencil beam scanning proton therapy. This MLIC is called a dual ring multilayer ionization chamber (DRMLIC). The shape of the electrodes allows the DRMLIC to measure both the percentage depth dose (PDD) and integrated depth dose (IDD) because ionization electrons are collected from inner and outer air gaps independently. Results: IDDs for which the beam energies were 71.6, 120.6, 159, 180.6, and 221.4 MeV were measured and compared with water phantom results. Furthermore, the measured PDDs along the central axis of the proton field with a nominal field size of 10 × 10 cm{sup 2} were compared. The spread out Bragg peak was 20 cm for fields with a range of 30.6 and 3 cm for fields with a range of 6.9 cm. The IDDs measured with the DRMLIC using the correction technique were consistent with those that of the water phantom; except for the beam energy of 71.6 MeV, all of the points satisfied the 1% dose/1 mm distance to agreement criterion of the gamma index. The 71.6 MeV depth dose profile showed slight differences in the shallow region, but 94.5% of the points satisfied the 1%/1 mm criterion. The 90% ranges, defined at the 90% dose position in distal fall off, were in good agreement with those in the water phantom, and the range differences from the water phantom were less than ±0.3 mm. The PDDs measured with the DRMLIC were also consistent with those that of the water phantom; 97% of the points passed the 1%/1 mm criterion. Conclusions: It was demonstrated that the new correction technique suppresses the difference between the depth dose profiles obtained with the MLIC and those obtained from a water phantom, and a DRMLIC enabling fast measurements of both IDD and PDD was developed. The IDDs and PDDs measured with the DRMLIC and using the correction technique were in good agreement with those that of the water phantom, and it was concluded that the correction technique and DRMLIC are useful for depth dose profile measurements in pencil beam scanning proton therapy.

60 APPLIED LIFE SCIENCES↗

An Analysis of Plan Robustness for Esophageal Tumors: Comparing Volumetric Modulated Arc Therapy Plans and Spot Scanning Proton Planning

Purpose: Planning studies to compare x-ray and proton techniques and to select the most suitable technique for each patient have been hampered by the nonequivalence of several aspects of treatment planning and delivery. A fair comparison should compare similarly advanced delivery techniques from current clinical practice and also assess the robustness of each technique. The present study therefore compared volumetric modulated arc therapy (VMAT) and single-field optimization (SFO) spot scanning proton therapy plans created using a simultaneous integrated boost (SIB) for dose escalation in midesophageal cancer and analyzed the effect of setup and range uncertainties on these plans. Methods and Materials: For 21 patients, SIB plans with a physical dose prescription of 2 Gy or 2.5 Gy/fraction in 25 fractions to planning target volume (PTV){sub 50Gy} or PTV{sub 62.5Gy} (primary tumor with 0.5 cm margins) were created and evaluated for robustness to random setup errors and proton range errors. Dose–volume metrics were compared for the optimal and uncertainty plans, with P<.05 (Wilcoxon) considered significant. Results: SFO reduced the mean lung dose by 51.4% (range 35.1%-76.1%) and the mean heart dose by 40.9% (range 15.0%-57.4%) compared with VMAT. Proton plan robustness to a 3.5% range error was acceptable. For all patients, the clinical target volume D{sub 98} was 95.0% to 100.4% of the prescribed dose and gross tumor volume (GTV) D{sub 98} was 98.8% to 101%. Setup error robustness was patient anatomy dependent, and the potential minimum dose per fraction was always lower with SFO than with VMAT. The clinical target volume D{sub 98} was lower by 0.6% to 7.8% of the prescribed dose, and the GTV D{sub 98} was lower by 0.3% to 2.2% of the prescribed GTV dose. Conclusions: The SFO plans achieved significant sparing of normal tissue compared with the VMAT plans for midesophageal cancer. The target dose coverage in the SIB proton plans was less robust to random setup errors and might be unacceptable for certain patients. Robust optimization to ensure adequate target coverage of SIB proton plans might be beneficial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗