Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPEDANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Impedance Modeling for Mixed Conductors with Simultaneous Insertion & Electrocatalytic Reactions: A Case Study of Transition-Metal Hydroxides in Aqueous Electrolyte

Electrochemical impedance spectroscopy (EIS) is commonly used to investigate the kinetics of mixed ionic–electronic conductor (MIEC) electrodes. Across various applications, MIECs exhibit ionic (e.g., insertion) and/or electronic (e.g., electrocatalytic) charge transfer reactions at the electrode/electrolyte interface. Bulk storage and transport of charge carriers also couple with these interfacial reactions. Here, we build a generalized, physics-based impedance model for MIECs with an ion-blocking current collector and explore how bulk and interfacial resistance, chemical capacitance, and DC polarization affect the impedance response. Using transition metal hydroxides as a case study, we provide guidance on extracting reaction kinetics or bulk resistance from the Nyquist plots in interface- or bulk-controlled conditions, respectively. Generalizing our EIS analysis enables a robust analysis of MIEC kinetics for a diverse set of systems.

36 MATERIALS SCIENCE↗

Tailoring the Ag + Content within the Tunnels and on the Exposed Surfaces of α-MnO 2 Nanowires: Impact on Impedance and Electrochemistry

Efficient conduction of both electrons and cations (e.g., Li + ) has a profound effect on the current and capacity of lithium-based batteries. With this study, we focus on cathode effects, with the preparation of pure silver hollandite materials with variable silver ion content within (intra-tunnel) and on the surface of α-MnO 2 tunneled materials, followed by the measurement and analysis of impedance and electrochemistry data. Specifically, pure Ag x Mn 8 O 16-y materials with low (x = 1.13) and high (x = 1.54) intra-tunnel silver content are compared with Ag x Mn 8 O 16-y ·aAg 2 O (a = 0.25, 0.63, 1.43) composites prepared via a new Ag 2 O coating strategy. When the Ag 2 O (a = 0, 0.25) content is low, the material with higher intra-tunnel silver (x = 1.53) content delivers up to ~5-fold higher capacity accounted for by a ~10-fold lower impedance than its lower intra-tunnel silver (x = 1.13) counterpart. In the presence of high Ag 2 O content (a = 0.63, 1.43), both composites exhibit comparable impedance but the lower intra-tunnel silver (x = 1.13) composite delivers up to ~1.5-fold higher capacity than higher intra-tunnel silver composite, highlighting the key role of Li + transport under those conditions. Our results demonstrate material design strategies which can significantly increase electronic and ionic conductivities.

25 ENERGY STORAGE↗

Electrode behavior RE-visited: Monitoring potential windows, capacity loss, and impedance changes in Li 1.03 (Ni 0.5 Co 0.2 Mn 0.3 ) 0.97 O 2 /silicon-graphite full cells

Here, the capacity and power performance of lithium-ion battery cells evolve over time. The mechanisms leading to these changes can often be identified through knowledge of electrode potentials, which contain information about electrochemical processes at the electrode-electrolyte interfaces. In this study we monitor electrode potentials within full cells containing a Li 1.03 (Ni 0.5 Co 0.2 Mn 0.3 ) 0.97 O 2 –based (NCM523) positive electrode, a silicon-graphite negative electrode, and an LiPF6-bearing electrolyte, with and without fluoroethylene carbonate (FEC) or vinylene carbonate (VC) additives. The electrode potentials are monitored with a Li-metal reference electrode (RE) positioned besides the electrode stack; changes in these potentials are used to examine electrode state-of-charge (SOC) shifts, material utilization, and loss of electrochemically active material. Electrode impedances are obtained with a Li x Sn RE located within the stack; the data display the effect of cell voltage and electrode SOC changes on the measured values after formation cycling and after aging. Our measurements confirm the beneficial effect of FEC and VC electrolyte additives in reducing full cell capacity loss and impedance rise after cycling in a 3.0–4.2 V range. Comparisons with data from a full cell containing a graphite-based negative highlight the consequences of including silicon in the electrode. Our observations on electrode potentials, capacity, and impedance changes on cycling are crucial to designing long-lasting, silicon-bearing, lithium-ion cells.

25 ENERGY STORAGE↗

Resolving Losses at the Negative Electrode in All-Vanadium Redox Flow Batteries Using Electrochemical Impedance Spectroscopy

We present an in situ electrochemical technique for the quantitative measurement and resolution of the ohmic, charge transfer and diffusion overvoltages at the negative electrode of an all-vanadium redox flow battery (VRFB) using electrochemical impedance spectroscopy (EIS). The mathematics describing the complex impedance of the V+2/V+3 redox reaction is derived and matches the experimental data. The voltage losses contributed by each process have been resolved and quantified at various flow rates and electrode thicknesses as a function of current density during anodic and cathodic polarization. The diffusion overvoltage was affected strongly by flow rate while the charge transfer and ohmic losses were invariant. On the other hand, adopting a thicker electrode significantly changed both the charge transfer and diffusion losses due to increased surface area. Furthermore, the Tafel plot obtained from the impedance resolved charge transfer overvoltage yielded the geometric exchange current density, anodic and cathodic Tafel slopes (135 5 and 121 5 mV/decade respectively) and corresponding transfer coefficients = 0.45 0.02 and = 0.50 0.02 in an operating cell.

complex impedance↗

Designing an impedance-based technique for studying corrosion on cladding materials

In nuclear cladding materials, changes in structure and chemistry over the lifetime of claddings can have a significant impact on fuel and reactor performance. Currently, chemical evolution over the lifetime of the fuel and cladding materials can only be inferred using post-irradiation examination. As an alternative to post-irradiation measurements, electrochemical impedance spectroscopy (EIS) can provide an in-pile measurement of changes in chemistry in oxides and hydrides. The objective of this study is to develop an impedance based sensing technology for measuring spatial- and time-resolved in-pile changes in cladding chemistry in order to understand the mechanisms of hydride formation, hydride dealloying and associated cladding corrosion so that a mitigation strategy and technology can be developed for reactor safe operation. Two prototype impedance-based sensors were designed and assembled using Zr-4 as working electrode and Pt as counter and reference electrode. One sensor is tubular type and the other one is plate-type. These sensors will be tested in static autoclave to investigate the effects of various environmental conditions (including temperature, pressure, and water chemistry) on cladding material corrosion mechanisms. These in-situ EIS sensors would provide corrosion-layer parameters in high-temperature water, such as (1) total layer thickness, (2) the evolution of oxide structures as uniform layer dielectric or sublayer(s), and (3) the possible electrochemistry of the volume corrosion process and the solid/liquid interface, such as the cyclic nature of corrosion of Zr alloys in high-temperature water. This work was focused on electrochemical sensor development, targeting cladding oxides/hydrides under thermodynamic equilibria; characterization of samples using Kelvin probe force microscopy (SKPFM), Raman spectroscopy, and scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS) to provide high-resolution co-localized characterization of zirconium oxide and metal/oxide interface.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Creating dynamic equivalent PV circuit models with impedance spectroscopy for arc-fault modeling.

Article 690.11 in the 2011 National Electrical Code{reg_sign} (NEC{reg_sign}) requires new photovoltaic (PV) systems on or penetrating a building to include a listed arc fault protection device. Currently there is little experimental or empirical research into the behavior of the arcing frequencies through PV components despite the potential for modules and other PV components to filter or attenuate arcing signatures that could render the arc detector ineffective. To model AC arcing signal propagation along PV strings, the well-studied DC diode models were found to inadequately capture the behavior of high frequency arcing signals. Instead dynamic equivalent circuit models of PV modules were required to describe the impedance for alternating currents in modules. The nonlinearities present in PV cells resulting from irradiance, temperature, frequency, and bias voltage variations make modeling these systems challenging. Linearized dynamic equivalent circuits were created for multiple PV module manufacturers and module technologies. The equivalent resistances and capacitances for the modules were determined using impedance spectroscopy with no bias voltage and no irradiance. The equivalent circuit model was employed to evaluate modules having irradiance conditions that could not be measured directly with the instrumentation. Although there was a wide range of circuit component values, the complex impedance model does not predict filtering of arc fault frequencies in PV strings for any irradiance level. Experimental results with no irradiance agree with the model and show nearly no attenuation for 1 Hz to 100 kHz input frequencies.

99 GENERAL AND MISCELLANEOUS↗

Impedances of Laminated Vacuum Chambers

First publications on impedance of laminated vacuum chambers are related to early 70s: those are of S. C. Snowdon [1] and of A. G. Ruggiero [2]; fifteen years later, a revision paper of R. Gluckstern appeared [3]. All the publications were presented as Fermilab preprints, and there is no surprise in that: the Fermilab Booster has its laminated magnets open to the beam. Being in a reasonable mutual agreement, these publications were all devoted to the longitudinal impedance of round vacuum chambers. The transverse impedance and the flat geometry case were addressed in more recent paper of K. Y. Ng [4]. The latest calculations of A. Macridin et al. [5] revealed some disagreement with Ref. [4]; this fact stimulated us to get our own results on that matter. Longitudinal and transverse impendances are derived for round and flat laminated vacuum chambers. Results of this paper agree with Ref. [5].

43 PARTICLE ACCELERATORS↗

3D Multiphysics Model for Large Scale Planar Cell: Inductance Investigation in Impedance Analysis

Developed a comprehensive 3D multiphysics model to analyze impedance behavior in large-scale planar Solid Oxide Fuel Cells (SOFCs). The model investigates how impedance varies across operating conditions and cell components, with a particular focus on inductive loops or negative capacitance at the air electrode. It was found that the Inductive loop disappears in the low-frequency zone when the activation overpotential or faradic current is not temperature-dependent. These findings offer new insights into SOFC impedance behavior.

impedence analysis↗

Magnetic and Impedance Analysis of Fe 2 O 3 Nanoparticles for Chemical Warfare Agent Sensing Applications

A dire need for real-time detection of toxic chemical compounds exists in both civilian and military spheres. In this paper, we demonstrate that inexpensive, commercially available Fe 2 O 3 nanoparticles are capable of selective sensing of chemical warfare agents (CWAs) using frequency-dependent impedance spectroscopy, with additional potential as an orthogonal magnetic sensor. X-ray magnetic circular dichroism analysis shows that Fe 2 O 3 nanoparticles possess moderately lowered moment upon exposure to 2-chloroethyl ethyl sulfide (2-CEES) and diisopropyl methylphosphonate (DIMP) and significantly lowered moment upon exposure to dimethyl methylphosphonate (DMMP) and dimethyl chlorophosphate (DMCP). Associated X-ray absorption spectra confirm a redox reaction in the Fe 2 O 3 nanoparticles due to CWA structural analog exposure, with differentiable energy-dependent features that suggest selective sensing is possible, given the correct method. Impedance spectroscopy performed on samples dosed with DMMP, DMCP, and tabun (GA, chemical warfare nerve agent) showed strong, differentiable, frequency-dependent responses. The frequency profiles provide unique “shift fingerprints” with which high specificity can be determined, even amongst similar analytes. The results suggest that frequency-dependent impedance fingerprinting using commercially available Fe 2 O 3 nanoparticles as a sensor material is a feasible route to selective detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

(abstract) Scaling Nominal Solar Cell Impedances for Array Design

This paper discusses a task the objective of which is to characterize solar cell array AC impedance and develop scaling rules for impedance characterization of large arrays by testing single solar cells and small arrays. This effort is aimed at formulating a methodology for estimating the AC impedance of the Mars Pathfinder (MPF) cruise and lander solar arrays based upon testing single cells and small solar cell arrays and to create a basis for design of a single shunt limiter for MPF power control of flight solar arrays having very different inpedances.

solar cells solar arrays AC impedance Mars Pathfin↗

Polyimide Aerogels and Porous Membranes for Ultrasonic Impedance Matching to Air

This work investigates acoustic impedance matching materials for coupling 200 kHz ultrasonic signals from air to materials with similar acoustic properties to that of water, flesh, rubber and plastics. Porous filter membranes as well as a new class of cross-linked polyimide aerogels are evaluated. The results indicate that a single impedance matching layer consisting of these new aerogel materials will recover nearly half of the loss in the incident-to-transmitted ultrasound intensity associated with an air/water, air/flesh or air/gelatin boundary. Furthermore, the experimental results are obtained where other uncertainties of the "real world" are present such that the observed impedance matching gains are representative of real-world applications. Performance of the matching layer devices is assessed using the idealized 3-layer model of infinite half spaces, yet the experiments conducted use a finite gelatin block as the destination medium.

acoustic impedance↗

(abstract) Vibration Method for Tracking the Resonant Mode and Impedance of a Microwave Cavity

We have developed a vibration technique to continuously maintain mode resonance and impedance match between a constant frequency magnetron source and resonant cavity. This method uses a vibrating metal rod to modulate the volume of the cavity that is equivalent to modulating an adjustable plunger. A similar vibrating metal rod attached to a stub tuner modulates the waveguide volume between the source and cavity. A phase sensitive detection scheme determines the optimum position of the adjustable plunger and stub tuner. The improved power transfer during the heating of a 99.8% pure alumina rod was demonstrated using this new technique. Temperature-time and reflected power-time plotswill be presented for the cases of no tracking, impedance tracker only, mode tracker only, and simultaneous impedance and mode tracking. Internal melting of the alumina rod near 2000°C with both trackers on will also be discussed.

microwave↗

NASA Investigation of Flow Direction Effects on Impedance Eduction for Acoustic Liners

In support of a collaboration with the International Forum for Aviation Research (IFAR), the NASA Langley Liner Physics Team has acquired a detailed dataset for use in the evaluation of flow direction effects on the acoustic liner impedance eduction process. Measurements are acquired with four acoustic liners designed to cover a range of sensitivities to source sound pressure level and tangential mean flow effects, specifically at source levels of 120 and 140 dB and centerline Mach numbers of 0.0, 0.1, 0.2, and 0.3. These measurements include detailed flow profile surveys upstream and downstream of the liner test window, as well as acoustic pressure data over the extent of the test window. The results clearly demonstrate the importance of the choice of Mach number used in the impedance eduction analysis. Average Mach number differences of less than 0.01 result in significant variation in the educed impedance spectra. These data will soon be supplied to the IFAR partners and will be made available for the general public within the next year.

acoustic↗

NASA Investigation of Flow Direction Effects on Impedance Eduction for Acoustic Liners

In support of a collaboration with the International Forum for Aviation Research (IFAR), the NASA Langley Liner Physics Team has acquired a detailed dataset for use in the evaluation of flow direction effects on the acoustic liner impedance eduction process. Measurements are acquired with four acoustic liners designed to cover a range of sensitivities to source sound pressure level and tangential mean flow effects, specifically at source levels of 120 and 140 dB and centerline Mach numbers of 0.0, 0.1, 0.2, and 0.3. These measurements include detailed flow profile surveys upstream and downstream of the liner test window, as well as acoustic pressure data over the extent of the test window. The results clearly demonstrate the importance of the choice of Mach number used in the impedance eduction analysis. Average Mach number differences of less than 0.01 result in significant variation in the educed impedance spectra. These data will soon be supplied to the IFAR partners and will be made available for the general public within the next year.

acoustic↗

Examination of Perforate Facesheet Impedance Prediction Models

This study examines several perforate facesheet impedance prediction models. Each model is validated with impedances educed from acoustic pressure measurements acquired in the NASA Langley Research Center Normal Incidence Tube (NIT) and Grazing Flow Impedance Tube (GFIT). This measurement dataset includes results for 73 NIT samples acquired at sound pressure levels of 100, 120, and 140 dB, and for 9 GFIT samples acquired at SPLs of 120 and 140 dB and at mean flow speeds of Mach 0.0, 0.3, and 0.5. Multiple metrics are evaluated based on different potential applications of the selected perforate facesheet model. An optimizer is then used to modify one of these models to more accurately match the full measurement dataset.

acoustic↗

Radio Frequency Surface Impedance Characterization System for Superconducting Samples at 7.5 GHz

A radio frequency (RF) surface impedance characterization (SIC) system that uses a sapphire-loaded Nb cavity operating at 7.5 GHz has been fabricated to measure the RF surface impedance of flat superconducting samples. Currently, the SIC system can make direct calorimetric surface impedance measurements in the central 0.8 cm2 area of 5 cm diameter disk samples in a temperature range from 2 to 20 K, exposed to a magnetic flux density of up to 14 mT. As an application, we present the measurement results for a bulk Nb sample.

36 MATERIALS SCIENCE↗

Low Impedance Bellows for High-current Beam Operations

In particle accelerators, bellows are commonly used to connect beamline components. Such bellows are traditionally shielded to lower the beam impedance. Excessive beam impedance can cause overheating in the bellows, especially in high beam current operation. For an SRF-based accelerator, the bellows must also be particulate free. Many designs of shielded bellows incorporate rf slides or fingers that prevent convolutions from being exposed to wakefields. Unfortunately these mechanical structures tend to generate particulates that, if left in the SRF accelerator, can migrate into superconducting cavities, the accelerator's critical components. In this paper, we describe a prototype unshielded bellows that has low beam impedance and no risk of particulate generation.

43 PARTICLE ACCELERATORS↗

Development of an Electrochemical Impedance Instrument for Monitoring Corrosion Formation (Oxide and Hydride) on Cladding Materials

The objective of this work package is to develop electrochemical impedance spectroscopic (EIS) techniques for the in pile measurement of changes in cladding materials in coupling with model simulation and material characterization. This work package will involve the initial development of electrochemical sensing technologies for measuring spatial and time resolved changes in cladding chemistry. Specific attention will be paid to monitoring changes in monitor cladding corrosion including oxide and hydride formation and deformation. The planned work during this period was focused on cladding material zirconium alloy corrosion, oxide and hydride development, and to characterize samples using EIS under controlled gas atmosphere, atom probe tomography (APT), Raman Spectroscopy, and Synchrotron X-ray diffraction (XRD). The corrosion, including oxide and hydride of zirconium alloy samples, was tested in this study. The samples were treated at a gas environment containing 3% H2 (vol%) balanced with N2 gas at various temperatures (100 – 500°C) and different times (up to 60 hours) and were characterized by in situ EIS. After treatment, various characterization techniques were applied to measure the samples, including TGA, Ramen, XRD, and APT. This study found that impedance spectra can be affected significantly with (furnace/environment) temperature. Higher temperature resulted in higher overall impedance, and longer exposure time exerted similar effects. Proof of concept characterization of oxidized samples, including TGA, Raman, XRD, and APT, were accomplished on samples exposed to 700 oC gas environment containing 20% O2 and 80% N2. TGA provides observable breakaway and bulk oxide growth measurements. High-temperature, in-situ Raman provides observation of oxidation stress at the surface of the oxide. Additionally, a transition from tetragonal to monoclinic zirconia can be seen early in the oxidation experiment. Specifically, tetragonal-rich zirconia is seen at the metal/oxide interface, where a transition to monoclinic-rich zirconia is seen in the bulk of the oxide. It has also been confirmed that highly compressive residual stresses are seen near the metal/oxide interface. It is concluded that the transition from tetragonal to monoclinic zirconia is induced by massive shifts in stress as the oxide grows. APT has supplied evident differences in the distribution of zirconium and oxygen at the metal/oxide interface. On the pre-breakaway sample, the metastable Zr(O) region at the boundary is relatively thin, interfaced by Zr-rich (i.e., metal) and O-rich (i.e., ZrO2) on either side. In contrast, it has been seen on a post-breakaway sample that the Zr(O) metastable region is much greater in thickness, with evidence of four “zones” showing slightly contrasting composition between 49-54% Zr. In addition, it can be seen from the Zr-2.65Nb post-breakaway sample that secondary element concentrations are considerably different than bulk composition measurements show. Specifically, Nb concentration is much lower than expected, whereas Fe concentration is much higher than expected. These differences could play a role in each element’s contribution to oxide growth mechanisms, as well as causation for breakaway. Future work is focused on analyzing EIS spectra of hydride and its correlation with characterization features, finite element (FE) modeling of cladding materials, electrochemical sensor development, targeting cladding oxides/hydrides under thermodynamic equilibria, during transients and under irradiation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗