Integration issues of a plasma contactor Power Electronics Unit

A hollow cathode-based plasma contactor is baselined on International Space Station Alpha (ISSA) for spacecraft charge control. The plasma contactor system consists of a hollow cathode assembly (HCA), a power electronics unit (PEU), and an expellant management unit (EMU). The plasma contactor has recently been required to operate in a cyclic mode to conserve xenon expellant and extend system life. Originally, a DC cathode heater converter was baselined for a continuous operation mode because only a few ignitions of the hollow cathode were expected. However, for cyclic operation, a DC heater supply can potentially result in hollow cathode heater component failure due to the DC electrostatic field. This can prevent the heater from attaining the proper cathode tip temperature for reliable ignition of the hollow cathode. To mitigate this problem, an AC cathode heater supply was therefore designed, fabricated, and installed into a modified PEU. The PEU was tested using resistive loads and then integrated with an engineering model hollow cathode to demonstrate stable steady-state operation. Integration issues such as the effect of line and load impedance on the output of the AC cathode heater supply and the characterization of the temperature profile of the heater under AC excitation were investigated.

Pinero, Luis R.↗

Neutron monitoring and electrode calorimetry experiments in the HIP-1 Hot Ion Plasma

Results are presented for two diagnostic procedures on HIP-1: neutron diagnostics to determine where neutrons originated within the plasma discharge chamber and electrode calorimetry to measure the steady-state power absorbed by the two anodes and cathodes. Results are also reported for a hot-ion plasma formed with a continuous-cathode rod, one that spans the full length of the test section, in place of the two hollow cathodes. The outboard neutron source strength increased relative to that at the midplane when (1) the cathode tips were moved farther outboard, (2) the anode diameters were increased, and (3) one of the anodes was removed. The distribution of neutron sources within the plasma discharge chamber was insensitive to the division of current between the two cathodes. For the continuous cathode, increasing the discharge current increased the midplane neutron source strength relative to the outboard source strength. Each cathode absorbed from 12 to 15 percent of the input power regardless of the division of current between the cathodes. The anodes absorbed from 20 to 40 percent of the input power. The division of power absorption between the anodes varied with plasma operating conditions and electrode placement.

Reinmann, J. J.↗

Hall Current Plasma Source Having a Center-Mounted or a Surface-Mounted Cathode

A miniature Hall current plasma source apparatus having magnetic shielding of the walls from ionized plasma, an integrated discharge channel and gas distributor, an instant-start hollow cathode mounted to the plasma source, and an externally mounted keeper, is described. The apparatus offers advantages over other Hall current plasma sources having similar power levels, including: lower mass, longer lifetime, lower part count including fewer power supplies, and the ability to be continuously adjustable to lower average power levels using pulsed operation and adjustment of the pulse duty cycle. The Hall current plasma source can provide propulsion for small spacecraft that either do not have sufficient power to accommodate a propulsion system or do not have available volume to incorporate the larger propulsion systems currently available. The present low-power Hall current plasma source can be used to provide energetic ions to assist the deposition of thin films in plasma processing applications.

Martinez, Rafael A.↗

Electric Propulsion Applications for Field Emitter Cathodes

Replacing hollow and filament cathodes with field emitter (FE) cathodes could significantly improve the scalability, power, and performance of some meso- and microscale Electric Propulsion (EP) systems.

Field emitters cathodes electric propulsion↗

NEXT Thruster Component Verification Testing

Component testing is a critical part of thruster life validation activities under NASA s Evolutionary Xenon Thruster (NEXT) project testing. The high voltage propellant isolators were selected for design verification testing. Even though they are based on a heritage design, design changes were made because the isolators will be operated under different environmental conditions including temperature, voltage, and pressure. The life test of two NEXT isolators was therefore initiated and has accumulated more than 10,000 hr of operation. Measurements to date indicate only a negligibly small increase in leakage current. The cathode heaters were also selected for verification testing. The technology to fabricate these heaters, developed for the International Space Station plasma contactor hollow cathode assembly, was transferred to Aerojet for the fabrication of the NEXT prototype model ion thrusters. Testing the contractor-fabricated heaters is necessary to validate fabrication processes for high reliability heaters. This paper documents the status of the propellant isolator and cathode heater tests.

Pinero, Luis R.↗

Space Station Cathode Ignition Test Status at 32,000 Cycles

A plasma contactor system has been baselined for the International Space Station for structural potential control. An ignition procedure was developed for the plasma contactor hollow cathode assembly (HCA). To demonstrate the required 99% HCA ignition reliability over 6,000 cycles, an ignition test was conducted. An accelerated test procedure was employed to rapidly accumulate ignition cycles. The test procedure minimized the differences between accelerated and non-accelerated test results. The development HCA used in this test has achieved 32,000 ignitions to date. The HCA has been qualified for cyclic operation, which could reduce xenon consumption and extend the life of the plasma contactor system.

Zakany, James S.↗

Advanced ion thruster research

A series of experiments conducted on a ring cusp magnetic field ion thruster; in which the anode, cathode and discharge chamber backplate were moved relative to the magnetic cusp; are described. Optimum locations for the anode, cathode and backplate which yield the lowest energy cost per plasma ion and highest extracted ion fraction are identified. The results are discussed in terms of simple physical models. The results of preliminary experiments into the operation of hollow cathodes on nitrogen and xenon over a large pressure range (0.1 to 100 Torr) are presented. They show that the cathode discharge transfers from the cathode insert to the exterior edge of the orifice plate as the interelectrode pressure is increased. Experimental evidence showing that a new ion extractor grid concept can be used to stabilize the plasma sheath at the screen grid is presented. This concept, identified by the term constrained sheath optics, is shown to hold ion beamlet divergence and impingement characteristics to stable values as the beamlet current and the net and total accelerating voltages are changed. The current status of a study of beamlet vectoring induced by displacing the accelerator and/or decelerator grids of a three grid ion extraction system relative to the screen grid is discussed.

Wilbur, P. J.↗

Space Station Cathode Design, Performance, and Operating Specifications

A plasma contactor system was baselined for the International Space Station (ISS) to eliminate/mitigate damaging interactions with the space environment. The system represents a dual-use technology which is a direct outgrowth of the NASA electric propulsion program and, in particular, the technology development efforts on ion thruster systems. The plasma contactor includes a hollow cathode assembly (HCA), a power electronics unit, and a xenon gas feed system. Under a pre-flight development program, these subsystems were taken to the level of maturity appropriate for transfer to U.S. industry for final development. NASA's Lewis Research Center was subsequently requested by ISS to manufacture and deliver the engineering model, qualification model, and flight HCA units. To date, multiple units have been built. One cathode has demonstrated approximately 28,000 hours lifetime, two development unit HCAs have demonstrated over 10,000 hours lifetime, and one development unit HCA has demonstrated more than 32,000 ignitions. All 8 flight HCAs have been manufactured, acceptance tested, and are ready for delivery to the flight contractor. This paper discusses the requirements, mechanical design, performance, operating specifications, and schedule for the plasma contactor flight HCAs.

Patterson, Michael J.↗

Cathode & Electromagnet Qualification Status and Power Processing Unit Development Update for the Ascendant Sub-kW Transcelestial Electric Propulsion System

A review of the component-level flight qualification efforts and power processing unit development status of the Ascendant Sub-kW Transcelestial Electric Propulsion System (ASTRAEUS) program is presented. Component-level qualification efforts were undertaken for the system’s ultra-compact heaterless LaB6 hollow cathode and electromagnets, both of which employ designs bespoke to ASTRAEUS, as they represent the highest failure risks for the thruster. Through parallel long-duration wear and ignition tests, the ASTRAEUS cathode demonstrated invariant discharge performance over more than 5000 h of operation at its maximum operating current of 4 A and demonstrated more than 25,000 ignition cycles. The ASTRAEUS electromagnets completed their environmental qualification through a demonstration of more than 1200 deep thermal cycles with no indication of coil degradation (the test articles previously completed qualification-level vibration and shock testing). ASTRAEUS’s prototype power processing unit has demonstrated more than 92% total power conversion efficiency and class-leading power density & specific power density of 4.5 W/cm3 & 1670 W/kg, respectively. The various power converters found in the ASTRAEUS power processing unit are reviewed with a focus on the methods by which such high performance was achieved.

Conversano, Ryan W.↗

Electric propulsion system technology

The work performed on the Ion Propulsion System Technology Task in FY90 is described. The objectives of this work fall under two broad categories. The first of these deals with issues associated with the application of xenon ion thrusters for primary propulsion of planetary spacecraft, and the second with the investigation of technologies which will facilitate the development of larger, higher power ion thrusters to support more advanced mission applications. Most of the effort was devoted to investigation of the critical issues associated with the use of ion thrusters for planetary spacecraft. These issues may be succinctly referred to as life time, system integration, and throttling. Chief among these is the engine life time. If the engines do not have sufficient life to perform the missions of interest, then the other issues become unimportant. Ion engine life time was investigated through two experimental programs: an investigation into the reduction of ion engine internal sputter erosion through the addition of small quantities of nitrogen, and a long duration cathode life test. In addition, a literature review and analysis of accelerator grid erosion were performed. The nitrogen addition tests indicated that the addition of between 0.5 and 1.0 percent of nitrogen by mass to the xenon propellant results in a reduction in the sputter erosion of discharge chamber components by a factor of between 20 and 50, with negligible reduction in thruster performance. The long duration test of a 6.35-mm dia. xenon hollow cathode is still in progress, and has accumulated more than 4,000 hours of operation at an emission current of 25 A at the time of this writing. One of the major system integration issues concerns possible interactions of the ion thruster produced charge exchange plasma with the spacecraft. A computer model originally developed to describe the behavior of mercury ion thruster charge exchange plasmas was resurrected and modified for xenon propellant. This model enables one to calculate the flow direction and local density of the charge exchange plasma, and indicates the degree to which this plasma can flow upstream of the thruster exhaust plane. A continuing effort to investigate the most desirable throttling technique for noble gas ion thrusters concentrated this year on experimentally determining the fixed flow rate throttling range of a 30-cm dia. thruster with a two-grid accelerator system. These experiments demonstrated a throttling capability which covers a 2.8 to 1 variation in input power. This throttling range is 55 percent greater than expected, and is due to better accelerator system performance at low net-to-total voltage ratios than indicated in the literature. To facilitate the development of large, higher power ion thrusters several brief studies were performed. These include the development of a technique which simulates ion thruster operation without beam extraction, the development of an optical technique to measure ion thruster grid distortion due to thermal expansion, tests of a capacitance measurement technique to quantify the accelerator system grid separation, and the development of a segmented thruster geometry which enables near term development of ion thrusters at power levels greater than 100 kW. Finally, a paper detailing the benefits of electric propulsion for the Space Exploration Initiative was written.

Brophy, John R.↗

Pulsed electromagnetic gas acceleration

Terminal voltage measurements with various cathodes and anodes in a high power, quasi-steady magnetoplasmadynamic (MPD) are discussed. The magnitude of the current at the onset of voltage fluctuations is shown to be an increasing function of cathode area and a weaker decreasing function of anode area. Tests with a fluted cathode indicated that the fluctuations originate in the plasma adjacent to the cathode rather than at the cathode surface. Measurements of radiative output from an optical cavity aligned to examine the current-carrying portion of a two-dimensional, 56 kA magnetoplasmadynamic discharge reveal no lasing in that region, consistent with calculations of electron excitation and resonance radiation trapping. A voltage-swept double probe technique allows single-shot determination of electron temperature and electron number density in the recombining MPD exhaust flow. Current distributions within the cavity of MPD hollow cathodes for various static prefills with no injected mass flow are examined.

Jahn, R. G.↗

Five-centimeter diameter ion thruster development

All system components were tested for endurance and steady state and cyclic operation. The following results were obtained: acceleration system (electrostatic type), 3100 hours continuous running; acceleration system (translation type), 2026 hours continuous running; cathode-isolator-vaporizer assembly, 5000 hours continuous operation and 190 restart cycles with 1750 hours operation; mercury expulsion system, 5000 hours continuous running; and neutralizer, 5100 hours continuous operation. The results of component optimization studies such as neutralizer position, neutralizer keeper hole, and screen grid geometry are included. Extensive mapping of the magnet field within and immediately outside the thruster are shown. A technique of electroplating the molybdenum accelerator grid with copper to study erosion patterns is described. Results of tests being conducted to more fully understand the operation of the hollow cathode are also given. This type of 5-cm thruster will be space tested on the Communication Technology Satellite in 1975.

Weigand, A. J.↗

The 15 cm diameter ion thruster research

The startup reliability of a 15 cm diameter mercury bombardment ion thruster which employs a pulsed high voltage tickler electrode on the main and neutralizer cathodes is examined. Startup of the thruster is achieved 100% of the time on the main cathode and 98.7% of the time on the neutralizer cathode over a 3640 cycle test. The thruster was started from a 20 C initial condition and operated for an hour at a 600 mA beam current. An energy efficiency of 75% and a propellant utilization efficiency of 77% was achieved over the complete cycle. The effect of a single cusp magnetic field thruster length on its performance is discussed. Guidelines are formulated for the shaping of magnetic field lines in thrusters. A model describing double ion production in mercury discharges is presented. The production route is shown to occur through the single ionic ground state. Photographs of the interior of an operating-hollow cathode are presented. A cathode spot is shown to be present if the cathode is free of low work-function surfaces. The spot is observed if a low work-function oxide coating is applied to the cathode insert. Results show that low work-function oxide coatings tend to migrate during thruster operation.

Wilbur, P. J.↗

A confocal laser-induced fluorescence diagnostic with an annular laser beam

Here, in this work, we report an annular beam confocal laser-induced fluorescence (LIF) configuration, which allows for high spatial resolution measurements of plasma properties in plasma setups and sources with limited optical access. The proposed LIF configuration utilizes the annular laser beam generated by a pair of diffractive axicons. The LIF signal is collected along the main optical axis within the ring region. It is shown experimentally that at a focal distance of 300 mm, a spatial resolution of ~5.3 mm can be achieved. Using geometric optics estimations, we showed that ~1 mm resolution at the same focal distance could potentially be achieved by modifying laser beam parameters. This approaches the localization accuracy of conventional LIF collection methods (with crossing laser beam injection and fluorescence collection optical paths). Measurements of the ion velocity distribution function in an argon plasma using both the confocal LIF with an annular laser beam and conventional LIF demonstrate a satisfactory agreement. The proposed LIF setup has potential applications for diagnostics in various plasma processing equipment and plasma sources, such as hollow cathodes, microplasmas, electric propulsion, etc.

47 OTHER INSTRUMENTATION↗

Numerical thermalization in 2D PIC simulations: Practical estimates for low-temperature plasma simulations

The process of numerical thermalization in particle-in-cell (PIC) simulations has been studied extensively. It is analogous to Coulomb collisions in real plasmas, causing particle velocity distributions (VDFs) to evolve toward a Maxwellian as macroparticles experience polarization drag and resonantly interact with the fluctuation spectrum. This paper presents a practical tutorial on the effects of numerical thermalization in 2D PIC applications. Scenarios of interest include simulations, which must be run for many thousands of plasma periods and contain a population of cold electrons that leave the simulation space very slowly. This is particularly relevant to many low-temperature plasma discharges and materials processing applications. We present numerical drag and diffusion coefficients and their associated timescales for a variety of grid resolutions, discussing the circumstances under which the electron VDF is modified by numerical thermalization. Though the effects described here have been known for many decades, direct comparison of analytically derived, velocity-dependent numerical relaxation timescales to those of other relevant processes has not often been applied in practice due to complications that arise in calculating thermalization rates in 1D simulations. Using these comparisons, we estimate the impact of numerical thermalization in several examples of low-temperature plasma applications including capacitively coupled plasma discharges, inductively coupled plasma discharges, beam plasmas, and hollow cathode discharges. Finally, we discuss possible strategies for mitigating numerical relaxation effects in 2D PIC simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser spectroscopy of metastable palladium at 340 and 363 nm

Here we report measurements of the isotope shift of the mass 104, 105, 106, 108, and 110 stable palladium isotopes for transitions from the metastable state $4d^9(^2D_{5/2})5s$, $^2[5/2]_3 → 4d^9(^2D_{5/2})5p, ^2[7/2]^o_4$ at 340 nm, and $4d^9(^2D_{5/2})5_s, ^2[5/2]_3 → 4d^9(^2D_{5/2})5p, ^2[3/2]^o_2$ at 363 nm. For 105 Pd , we determine the hyperfine structure of both transitions. The measurements were performed by saturation absorption spectroscopy in a custom-built hollow cathode lamp and will serve as a reference for collinear laser spectroscopy of short-lived neutron-rich palladium isotopes. We also report on the observation of a population inversion for the 363-nm transition under certain discharge conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Research and Development to Reduce Impurity Production and Transport of the Impurities to the Target in Linear Plasma Devices Using Helicon Plasma Sources

Linear plasma devices used to test plasma facing materials (PFMs) and components for fusion reactors are often suffering under the production of intrinsic impurities from the plasma source system. Most linear plasma devices use internal electrodes (hollow cathodes, reflex arc, or cascading arc), which typically are the source of the main impurities. The next-generation plasma generators use radio frequency (RF) plasma sources like helicons to avoid internal electrodes. However, high power operation of helicons has proven to result in impurity production due to the high rectified sheath voltages created. Depending on the plasma parameters and magnetic configuration, these impurities can be transported to the target and deposited there to unacceptable high levels. Here, in this contribution, the experimental results from Proto-MPEX are summarized, and the conclusions of the impurity source physics are given. Methods to reduce the impurity production, the impurity transport, and the net deposition on the target are presented. These methods to reduce the impurity production include Faraday screens to reduce the sheath voltage drop, high-Z refractory coatings to reduce the erosion yield, and wall conditioning methods. Methods to reduce the impurity transport include changes in the magnetic configuration as well as electron heating to change axial and radial temperature profiles. Preliminary results on the effectiveness of some of these methods are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fabricating Diamond-like Amorphous Carbon

Using a magnetically confined hot hollow cathode PE-CVD, hydrocarbon gas is decomposed under a diluent gas to deposit hydrogenated amorphous carbon onto a sample holder. During the fabrication of the hydrogenated amorphous carbon, the electric potential, electron temperature, and electron density of the plasma are measured with a Langmuir probe. Raman spectroscopy is used to determine the structural and electronic characterization of the final hydrogenated amorphous carbon solid.