Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High Temperature Test Facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Long-Term Static and Dynamic Corrosion Stability of Nonwetting Surfaces

Superhydrophobic surfaces (SHSs) and lubricant-infused surfaces (LISs) are two classes of nonwetting surfaces that have drawn attention due to their advanced functional properties including corrosion inhibition. Yet there is a conspicuous lack of corrosion study of SHSs and LISs with respect to their fabrication and material parameters, especially at high temperatures and under dynamic flow conditions over long durations, which is sought to be addressed in this article. Considering copper SHSs and LISs, a full factorial combinatorial study of two facile texturing processes, electrodeposition and etching, two different functionalization agents, stearic acid and mercaptan, and two types of infused lubricants, Krytox 104 and DOWSIL 510, is presented, encompassing over 650 measurements on 90 tested surfaces. All fabricated surfaces demonstrated water repellency with a contact angle above 150° and a sliding angle below 7°. For the first time, the study examines high-temperature corrosion stability and long-term corrosion durability of the nonwetting surfaces in both static fluid and dynamic turbulent flow conditions over a period of 30 days. Here, LISs and SHSs are shown to provide excellent corrosion inhibition over all tested corrosion conditions, with negligible presence of corrosion species on the surfaces and no deterioration of the texturing. The surfaces are also shown to rejuvenate easily to the initial wettability and corrosion resistance values. This study provides valuable insights into the selection of materials and processing parameters for the fabrication of nonwetting surfaces for the application of interest.

Copper↗

Final Status Report Confirming Completion of Mechanical Testing of HFIR Irradiated Nanocomposite Materials

This report provides a final status report on the in-cell mechanical testing of High Flux Isotope Reactor (HFIR)-irradiated nanodispersion-strengthened materials at the Irradiated Materials Examination and Testing (IMET) facility. All tension tests were performed at room temperature with a nominal strain rate of 0.018 mm/mm/min using shoulder-loading grip sets by following the standard testing procedure in ASTM E8/E8M. Round 1 (unirradiated) and round 2 (0.7 dpa) testing was completed in FY 2021. This report confirms completion of round 3 (1.4 dpa) and round 4 (2.1 dpa) tensile testing in FY 2022 with examples of test data collected on select sample conditions. Additionally, the report includes IDs of samples selected for shipment to Idaho National Laboratory (INL) for additional characterization.

36 MATERIALS SCIENCE↗

High temperature skin friction measurement

Skin friction measurement in the NASA Langley hypersonic propulsion facility is described. The sensor configuration utilized an existing balance, modified to provide thermal isolation and an increased standoff distance. For test run times of about 20 sec and ambient-air cooling of the test section and balance, the modified balance performed satisfactorily, even when it was subjected to acoustic and structural vibration. The balance is an inertially balanced closed-loop servo system where the current to a moving-coil motor needed to restore or null the output from the position sensor is a measure of the force or skin friction tending to displace the moving element. The accuracy of the sensor is directly affected by the position sensor in the feedback loop, in this case a linear-variable differential transformer which has proven to be influenced by temperature gradients.

Tcheng, Ping↗

Support of gas flowmeter upgrade

A project history review, literature review, and vendor search were conducted to identify a flowmeter that would improve the accuracy of gaseous flow measurements in the White Sands Test Facility (WSTF) Calibration Laboratory and the Hydrogen High Flow Facility. Both facilities currently use sonic flow nozzles to measure flowrates. The flow nozzle pressure drops combined with corresponding pressure and temperature measurements have been estimated to produce uncertainties in flowrate measurements of 2 to 5 percent. This study investigated the state of flowmeter technology to make recommendations that would reduce those uncertainties. Most flowmeters measure velocity and volume, therefore mass flow measurement must be calculated based on additional pressures and temperature measurement which contribute to the error. The two exceptions are thermal dispersion meters and Coriolis mass flowmeters. The thermal dispersion meters are accurate to 1 to 5 percent. The Coriolis meters are significantly more accurate, at least for liquids. For gases, there is evidence they may be accurate to within 0.5 percent or better of the flowrate, but there may be limitations due to inappropriate velocity, pressure, Mach number and vibration disturbances. In this report, a comparison of flowmeters is presented. Candidate Coriolis meters and a methodology to qualify the meter with tests both at WSTF and Southwest Research Institute are recommended and outlined.

Waugaman, Dennis↗

Testing of a 15 kA Superconducting Transformer

Here, the manufacturing of superconducting magnets for High Energy Physics (HEP) and Fusion Energy Sciences (FES) applications requires high-current conductors to generate stronger magnetic fields without increasing the inductance of the magnet. Increased inductance is undesirable due to the associated AC losses, which reduce the temperature margin; and the quench protection also becomes complicated. Testing high-current conductors with a direct current (DC) room temperature power supply is unfeasible for two primary reasons: 1) the limited capacity to supply large currents, and 2) the significant heat load losses at the current leads. A superconducting transformer offers a solution to both challenges. A 50-kA superconducting transformer is planned for manufacturing and commissioning at Brookhaven National Laboratory as part of its user facility upgrade. This transformer will facilitate the testing of superconducting cables, conductors, joints, and insert coils under high magnetic field conditions (10 T) and with currents up to 50-kA. To evaluate the manufacturing process and validate the theoretical models, the magnet division has developed and tested a 15-kA prototype transformer. A control loop has been implemented to ensure precise current delivery to the sample. This paper presents the coil design, manufacturing, and experimental results from the cold tests.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An Overview of Nuclear Thermal Rocket Element Environmental Simulator (NTREES) Capabilities, Upgrades, and Overlaps in Advanced Material Testing Areas

The Nuclear Thermal Rocket Element Environmental Simulator (NTREES) was designed to perform non-nuclear testing of nuclear thermal rocket (NTR) fuel elements and materials. NTREES can simulate the thermal hydraulic environment within the reactor of an NTR and has been leveraged to provide data on the thermochemical, thermomechanical and thermohydraulic performance of components and materials. Active upgrades to the NTREES facility include installing a DC power supply for DC powered joule heating, a supply gas chiller for a cryogenically cool gas supply, gas pre-heaters with sample holders for testing samples too small to be inductively heated by bathing them in hot gas, and a high temperature digital image correlation (DIC) capability for measuring high temperature strains real time. In addition to NTR testing, given the commonality of high enthalpy flow environments between the reactor of an NTP engine and the aerothermal heating of high-speed flight, the unique capabilities of NTREES to provide high temperature gas flows at high pressure without combustion or electrode spallation byproducts may lend itself to additional usage of the facility beyond the original intent.

Michael P Schoenfeld↗

Experimental performance of the regenerator for the Chrysler upgraded automotive gas turbine engine

Automobile gas turbine engine regenerator performance was studied in a regenerator test facility that provided a satisfactory simulation of the actual engine operating environment but with independent control of airflow and gas flow. Velocity and temperature distributions were measured immediately downstream of both the core high-pressure-side outlet and the core low-pressure-side outlet. For the original engine housing, the regenerator temperature effectiveness was 1 to 2 percent higher than the design value, and the heat transfer effectiveness was 2 to 4 percent lower than the design value over the range of test conditions simulating 50 to 100 percent of gas generator speed. Recalculating the design values to account for seal leakage decreased the design heat transfer effectiveness to values consistent with those measured herein. A baffle installed in the engine housing high-pressure-side inlet provided more uniform velocities out of the regenerator but did not improve the effectiveness. A housing designed to provide more uniform axial flow to the regenerator was also tested. Although temperature uniformity was improved, the effectiveness values were not improved. Neither did 50-percent flow blockage (90 degree segment) applied to the high-pressure-side inlet change the effectiveness significantly.

Winter, J. M.↗

Reference surface excess isotherms for carbon dioxide adsorption on ammonium ZSM-5 at various temperatures

Abstract This work is part of the effort at the Facility for Adsorbent Characterization and Testing (FACT lab) at the National Institute of Standards and Technology (NIST) to develop reference materials, reference data, and measurement best practices for adsorption metrology. High-pressure surface excess isotherms for CO 2 adsorption on NIST Reference Material 8852 (ammonium ZSM-5) at 15 °C, 25 °C, and 35 °C are reported, expanding on a FACT Lab-organized international interlaboratory study on this sorbent/sorbate pair at 20 °C. The range of temperatures of the present study is of interest for many CO 2 adsorption measurements and applications. Measurements were made using five different adsorption instruments, both manometric and gravimetric. Excellent agreement in the measured isotherms among the instruments was found. An empirical reference equation of the form, $${n}_{ex,ref}({P}_{eq})=\frac{c}{\{{1+\mathrm{exp}[\left(-\mathrm{ln}\left(P\right)+a\right)/b ]\}}^{b }} ,$$ n e x , r e f ( P eq ) = c { 1 + exp [ - ln P + a / b ] } b , [ n ex,ref is surface excess uptake (mmol/g); P eq is equilibrium pressure (MPa); P is ( P eq )/(1 MPa)]; a , b , c are constants] and the 95% uncertainty interval were determined for the isotherms at each of the temperatures. Lastly, the isosteric heat of adsorption is estimated from absolute isotherms derived from the surface excess reference data.

Nguyen, Huong Giang T. (ORCID:0000000210527565)↗

Benchmark Specification for Select Experiments Conducted at the University of Wisconsin-Madison Thermal Stratification Test Facility

The Department of Energy (DOE)-Nuclear Energy University Programs (NEUP) supported the creation and operation of the Thermal Stratification Test Facility (TSTF) at the University of Wisconsin Madison (UWM) as part of a larger effort to understand thermal stratification behavior in liquid-metal-cooled reactors. The TSTF was designed to simulate transients in a reactor plenum that are known to cause thermal stratification. High-reliability and high-resolution measurements of the flow and temperature were collected for use as experimental benchmarks to support validation efforts for computational models. The results of these tests contribute to the greater understanding of thermal stratification behavior of liquid sodium under various configurations and operating conditions. The six TSTF tests selected for benchmarking are a set of forced circulation tests at a fixed flow rate with different Upper Internal Structure (UIS) configurations in the test section (no UIS, solid UIS, and a UIS with flow area of 4, 8, 12, and 100%). This report provides a complete description of the benchmark problems, including all key test facility details, descriptions of each test condition, and measured data for comparison with modeled results.

42 ENGINEERING↗

Cryogenic Test Results of Hextek Mirror

A 250 mm diameter lightweight borosilicate mirror has been interferometrically tested from room-temperature down to 30 K at the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center (MSFC). The minor blank was manufactured by Hextek Corporation using a high-temperature gas fusion process and was then polished at MSFC. It is a sandwich-type mirror consisting of a thin face-sheet (approx.1.5 mm thick), a core structure (20 mm thick, approx.43 mm diameter cells, & 0.5-1.2 mm thick walls), and a thin back-sheet (3 mm thick). The mirror has a 2500 mm spherical radius-of- curvature @/lo). The areal density is 14 kg/sq m. The mirror was tested in the 1 m x 2 m chamber using an Instantaneous Phase Interferometer (PI) from ADE Phase Shift Technologies. The mirror was tested twice. The first test measured the change in surface figure from ambient to 30 K and the repeatability of the change. An attempt was then made by QED Technologies to cryo-figure the mirror using magnetorheological finishing. The second test measured the effectiveness of the cryo- figuring. This paper will describe the test goals, the test instrumentation, and the test results for these cryogenic tests.

Hadaway, James↗

Outgassing Characterization of Common Trash Items for Disposal By Nanoracks Airlock on the International Space Station

The arrival of the Nanoracks Airlock to the International Space Station (ISS) has provided the ISS program the capability to dispose of common trash items. The concept of operations involved the crew bagging up those items into a trash bag and then utilizing the robotic arm and the airlock to jettison the trash bag. Because of the unknown thermal vacuum stability of some of the items, a molecular contamination concern was raised by the ISS program as the trash is exposed to vacuum upon the evacuation of air from the airlock and the robotic arm moving the airlock to its jettison location. In order to characterize the representative outgassing rates for ISS trash, thermal vacuum testing was performed at White Sands Test Facility. Trash was sorted into a “lower” outgassing bag and a “mixed” bag. The “mixed” trash bag contained more items that were suspected to be not vacuum stable. Load cells were chosen as the primary means for measuring mass loss. A sharp decay in the outgassing rate was observed in the first 30 minutes followed by a slower decay. As expected, the “mixed” bag lost more mass. While Quartz Crystal Microbalances (QCMs) are often utilized to measure long term outgassing rates and the sticking coefficients of contaminants at different operating temperatures for vacuum stable materials, these measurements proved difficult due to the amount and the inclusion of materials with suspect thermal vacuum stability. Because of high rates of material outgassing, the facility was unable to maintain the CQCM temperature setpoint of 80 K QCMs.. The QCMs operating at the warmer temperatures also saturated on occasion due to high levels of condensed matter. Though testing was able to confirm high risk of outgassing contamination for the program, true sticking coefficients could not be determined, available measurements are provided herein.

Alvin Y Huang↗

Testing Long-Term Exposure To Vacuum

Facility for studying long-term effects of vacuum on materials described in report. Vacuum storage system maintains specimens at constant temperature and high vacuum. Enables specimens to be removed easily and safely for analysis. Nitrogen storage system maintains specimens at 77 degree F in pure, dry nitrogen gas under gauge pressure of 2 to 4 psi. Enables comparison of control specimens with specimens exposed to vacuum. Instrumentation-and-control system measures and records operating parameters and generates control signals and alarm indications as necessary.

Clark, D. L.↗

Promoted Metals Combustion at Ambient and Elevated Temperatures

Promoted combustion testing of materials, Test 17 of NASA STD-6001, has been used to assess metal propensity to burn in oxygen rich environments. An igniter is used at the bottom end of a rod to promote ignition, and if combustion is sustained, the burning progresses from the bottom to the top of the rod. The physical mechanisms are very similar to the upward flammability test, Test 1 of NASA STD-6001. The differences are in the normal environmental range of pressures, oxygen content, and sample geometry. Upward flammability testing of organic materials can exhibit a significant transitional region between no burning to complete quasi-state burning. In this transitional region, the burn process exhibits a probabilistic nature. This transitional region has been identified for metals using the promoted combustion testing method at ambient initial temperatures. The work given here is focused on examining the transitional region and the quasi-steady burning region both at conventional ambient testing conditions and at elevated temperatures. A new heated promoted combustion facility and equipment at Marshall Space Flight Center have just been completed to provide the basic data regarding the metals operating temperature limits in contact with oxygen rich atmospheres at high pressures. Initial data have been obtained for Stainless Steel 304L, Stainless Steel 321, Haynes 214, and Inconel 718 at elevated temperatures in 100-percent oxygen atmospheres. These data along with an extended data set at ambient initial temperature test conditions are examined. The pressure boundaries of acceptable, non-burning usage is found to be lowered at elevated temperature.

Engel, Carl D.↗

Thermal Stability of RP-2 for Hydrocarbon Boost Regenerative Cooling

A series of tests were performed in the NASA Glenn Research Centers Heated Tube Facility to study the heat transfer and thermal stability behavior of RP-2 under conditions similar to those found in rocket engine cooling channels. It has long been known that hydrocarbon fuels, such as RP-2, can decompose at high temperature to form deposits (coke) which can adversely impact rocket engine cooling channel performance. The heated tube facility provides a simple means to study these effects. Using resistively heated copper tubes in a vacuum chamber, flowing RP-2 was heated to explore thermal effects at a range of test conditions. Wall temperature (850-1050F) and bulk fluid temperature (300-500F) were varied to define thermal decomposition and stability at each condition. Flow velocity and pressure were fixed at 75 fts and 1000 psia, respectively. Additionally, five different batches of RP-2 were tested at identical conditions to examine any thermal stability differences resulting from batch to batch compositional variation. Among these tests was one with a potential coke reducing additive known as 1,2,3,4-Tetrahydroquinoline (THQ). While copper tubes were used for the majority of tests, two exploratory tests were performed with a copper alloy known as GRCop-42. Each tube was instrumented with 15 thermocouples to examine the temperature profile, and carbon deposition at each thermocouple location was determined post-test in an oxidation furnace. In many tests, intermittent local temperature increases were observed visually and in the thermocouple data. These hot spots did not appear to correspond with a higher carbon deposition.

Kleinhenz, Julie E.↗

High resolution microstructural, chemical studies and localized burnup analysis in an irradiated U–10Zr metallic fuel

This study involves high resolution characterization of a sodium bonded solid uranium (U)-10 wt% zirconium (Zr) metallic fuel irradiated in Fast Flux Test Facility (FFTF). The fuel centerline temperature during irradiation was estimated to be around 675 °C with the peak burnup 13.1 atomic percent. Samples for transmission electron microscopy (TEM) and atom probe tomography (APT) were prepared from different regions/zones in the fuel cross section radially to elucidate the microstructural changes and chemical redistribution of solute elements as well as fission products during irradiation experiment. TEM results indicate the irradiation in fast flux testing leads to the formation of extensive Zr-rich precipitates with varying sizes in the U–Zr fuel matrix. APT analysis performed to investigate redistribution of Zr, U and fission products along the radial direction of fuel pin showed Zr-rich precipitates entrapping the fission products in higher concentration as compared to the α-U phases. Here, the local burnup ( 235 U depletion) is found to be consistent, calculated by quantification of 235 U, 236 U and 238 U isotopes from mass spectrum obtained from APT along the radial direction. Zr-rich precipitation and its implication on fuel constitutional redistribution are discussed based on SEM, TEM and APT results.

APT↗

Seeing through nuclear fuel: Three-dimensional, nondestructive X-ray microscopy and volumetric analyses of neutron-irradiated TRISO-coated fuel kernels

The three-dimensional (3D) characterization of nuclear fuel with X-ray microscopy has historically proven difficult, due to uranium’s high attenuation of easily accessible X-rays, both in a laboratory setting and at a synchrotron user facility. However, this imaging modality provides nondestructive information that can be used to investigate morphological changes arising from external stimuli (e.g., neutron irradiation, high-temperature testing). Using an appropriate X-ray energy spectrum and an adequate X-ray filter, suitable transmissions through properly sized nuclear fuel specimens can be achieved. Here, in this study, we present the methods and results of using a commercially available, laboratory-based X-ray microscope (XRM) to examine the extent of 3D morphological changes of tristructural isotropic (TRISO)-coated fuel particles, specifically uranium oxide/uranium carbide fuel kernels, after high-temperature neutron irradiation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design and evaluation of high contact ratio gearing

Scoring test and surface fatigue tests were conducted on spur gears of a standard design and spur gears of a high contact ratio design. All testing was conducted in the Sikorsky 6-inch dynamic test facility at a speed of 8000 rpm using 23699 oil. Bulk gear temperatures were also recorded. The surface fatigue tests were run at Hertz stresses of 165 x 10 to the 7th power N/sq m and 145 x 10 to the 7th power N/sq m (240,000 and 210,000 psi), respectively.

Frint, Harold K.↗

The Mach 10 Component of NASA's Hyper-X Ground Test Program

The Mach 10 Hyper-X ground test program is described, in which experimental flowpath parametric testing is being done in the HYPULSE facility. This facility has been upgraded for this effort by adding a reflected-shock-tunnel operating mode to access test conditions at Mach 10 and below. A large test section and hypersonic nozzle have been installed to provide full-scale engine test capability and the instrumentation systems have been expanded. A model of the Hyper-X engine flowpath has been built for freejet testing in the shock tunnel at both Mach 7 and 10 flight conditions. The model has over 180 instrumentation ports, a pitot rake mountable at the engine inlet or exit, and optical windows for visualization of the isolator, combustor, and nozzle. Testing in HYPULSE has been completed at Mach 7 conditions to provide a link between pulse facility data and the large Hyper-X performance database that is being accumulated in long-duration facilities. Comparisons of Mach 7 data with computational predictions and with data recently acquired for an identical flowpath being tested in the NASA 8-foot High Temperature Tunnel are presented.

Bakos, R. J.↗