Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High Performance Building Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

New Whole-House Solutions Case Study: Fort Devens: Cold Climate Market-Rate Townhomes Targeting HERS Index of 40, Harvard, Massachusetts

Achieving aggressive energy efficiency targets requires tight coordination and clear communication among owners, designers, builders, and subcontractors. For this townhome project, MassDevelopment, the quasi-governmental agency owner, selected Metric Development of Boston, teaming with Building America team Consortium for Advanced Residential Buildings (CARB) and Cambridge Seven Architects, to build very high performing market-rate homes. Fort Devens is part of a decommissioned army base in working-class Harvard, Massachusetts, approximately one hour northwest of Boston. The team proposed 12 net zero energy-ready townhomes that were also designed to achieve a Home Energy Rating System (HERS) Index Score of 41 before adding renewables. The team carefully planned the site to maximize solar access, daylighting, and efficient building forms.

air tight envelope↗

Long-Term Monitoring of Mini-Split Ductless Heat Pumps in the Northeast

Transformations, Inc. has extensive experience building their high performance housing at a variety of Massachusetts locations, in both a production and custom home setting. The majority of their construction uses mini-split heat pumps (MSHPs) for space conditioning. This research covered the long-term performance of MSHPs in Zone 5A; it is the culmination of up to 3 years' worth of monitoring in a set of eight houses. This research examined electricity use of MSHPs, distributions of interior temperatures and humidity when using simplified (two-point) heating systems in high-performance housing, and the impact of open-door/closed-door status on temperature distributions. The use of simplified space conditioning distribution (through use of MSHPs) provides significant first cost savings, which are used to offset the increased investment in the building enclosure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: Selecting Ventilation Systems for Existing Homes

In multifamily buildings, particularly in the Northeast, exhaust ventilation strategies are the norm as a means of meeting both local exhaust and whole-unit mechanical ventilation rates. The issue of where the "fresh" air is coming from is gaining significance as air-tightness standards for enclosures become more stringent, and the normal leakage paths through the building envelope disappear. Researchers from the Consortium for Advanced Residential Buildings (CARB) found that the majority of high performance, new construction, multifamily housing in the Northeast use one of four general strategies for ventilation: continuous exhaust only with no designated supply or make-up air source, continuous exhaust with ducted make-up air to apartments, continuous exhaust with supply through a make-up air device integral to the unit HVAC, and continuous exhaust with supply through a passive inlet device, such as a trickle vent. Insufficient information is available to designers on how these various systems are best applied. In this project, the CARB team evaluated the four different strategies for providing make-up air to multifamily residential buildings and developed guidelines to help contractors and building owners choose the best ventilation systems.

apartments↗

Developing High-Performance Computing Model of Vapor Transition Through Advanced Membranes for Applications in 7AC Liquid Desiccant Air Conditioners

This poster for the 2019 Advanced Manufacturing Office Peer Review covers the high-performance computing model development for applications in Liquid Desiccant Air Conditioners. Conventional compressor-based cooling has undergone incremental changes over the past 100 years. Further improvements in efficiency require evermore complex systems, especially under humid conditions. Microporous membranes offer unique opportunities for efficient humidity control in buildings using an absorbent desiccant solution, but membranes are not designed for this purpose. This project used molecular dynamic (MD) simulations to determine the effect of membrane properties on important metrics for these air-conditioning applications, focusing on the membrane properties at the membrane/liquid/air interface. Improved membranes can enable smaller, more durable, and less costly designs for these membrane air conditioning systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

One Step Block-like Copolymers from an Upcycled Monomer Using Ring-Opening Metathesis Polymerization

Block-like copolymers can be readily synthesized in one step using monomers with widely separated reactivity ratios. Here, we show that trans,trans,trans-1,5,9-cyclododecatriene (CDT), produced from polybutadiene via cyclodepolymerization (CDP), undergoes gradient copolymerization via ring-opening metathesis polymerization (ROMP) with a selected norbornene monomer to produce a block-like copolymer that exhibits bulk nanophase separation and excellent thermomechanical performance. These data highlight a new ROMP copolymerization system with a sharp compositional drift and introduce a simple pathway to convert waste plastic into a valuable building block for high-value thermoplastic materials.

block copolymer↗

Surface and bulk two-level-system losses in lithium niobate acoustic resonators

Lithium niobate (LN) is a promising material for building acoustic resonators used in quantum applications, but its performance is limited by poorly understood material defects called two-level systems (TLSs). Here, in this work, we fabricate high-performance acoustic resonators from LN with quality factors up to 6 ×10 7 and use them to separate bulk and surface contributions to TLS loss. By comparing these bulk acoustic wave (BAW) resonators with previous surface-acoustic-wave and phononic-crystal studies, we show that devices with high surface-participation ratios are limited by surface TLSs, while our BAW devices reveal an intrinsic bulk TLS limit. Through systematic surface treatments and microscopy, we demonstrate that BAW resonator performance remains unchanged despite surface modifications, confirming operation in a bulk-limited regime. Here, our work establishes quantitative bounds on both surface and bulk TLS losses in LN within the context of the material growth and fabrication approaches we have pursued, and it provides guidance for future device engineering and materials development.

acoustic wave phenomena↗

Validation of a Hot Water Distribution Model Using Laboratory and Field Data

Characterizing the performance of hot water distribution systems is a critical step in developing best practice guidelines for the design and installation of high performance hot water systems. Developing and validating simulation models is critical to this effort, as well as collecting accurate input data to drive the models. In this project, the Building America research team ARBI validated the newly developed TRNSYS Type 604 pipe model against both detailed laboratory and field distribution system performance data. Validation efforts indicate that the model performs very well in handling different pipe materials, insulation cases, and varying hot water load conditions. Limitations of the model include the complexity of setting up the input file and long simulation run times. This project also looked at recent field hot water studies to better understand use patterns and potential behavioral changes as homeowners convert from conventional storage water heaters to gas tankless units. The team concluded that the current Energy Factor test procedure overestimates typical use and underestimates the number of hot water draws, which has implications for both equipment and distribution system performance. Gas tankless water heaters were found to impact how people use hot water, but the data does not necessarily suggest an increase in usage. Further study in hot water usage and patterns is needed to better define these characteristics in different climates and home vintages.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Passive Vents in New Construction Multifamily Buildings

Exhaust ventilation and corresponding outdoor air strategies are being implemented in high performance, new construction, multifamily buildings to meet program or code requirements for improved indoor air quality, but a lack of clear design guidance is resulting in poor performance of these systems despite the best intentions of the programs or standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of the Potential to Achieve very Low Energy Use in Public Buildings in China with Advanced Window and Shading Systems

As rapid growth in the construction industry continues to occur in China, the increased demand for a higher standard living is driving significant growth in energy use and demand across the country. Building codes and standards have been implemented to head off this trend, tightening prescriptive requirements for fenestration component measures using methods similar to the U.S. model energy code American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) 90.1. The objective of this study is to (a) provide an overview of applicable code requirements and current efforts within China to enable characterization and comparison of window and shading products, and (b) quantify the load reduction and energy savings potential of several key advanced window and shading systems, given the divergent views on how space conditioning requirements will be met in the future. System-level heating and cooling loads and energy use performance were evaluated for a code-compliant large office building using the EnergyPlus building energy simulation program. Commercially-available, highly-insulating, low-emittance windows were found to produce 24%–66% lower perimeter zone HVAC electricity use compared to the mandated energy-efficiency standard in force (GB 50189-2005) in cold climates like Beijing. Low-e windows with operable exterior shading produced up to 30%–80% reductions in perimeter zone HVAC electricity use in Beijing and 18%–38% reductions in Shanghai compared to the standard. The economic context of China is unique since the cost of labor and materials for the building industry is so low. Broad deployment of these commercially available technologies with the proper supporting infrastructure for design, specification, and verification in the field would enable significant reductions in energy use and greenhouse gas emissions in the near term.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of Oversized Crates containing Nuclear Waste

The 212-N Building at the Hanford Site held fifteen large crates containing glove boxes and process equipment associated with the development and fabrication of mixed oxide (MOX) fuel. The gloveboxes and associated equipment originated from the 308 Building of the Hanford Site and had been placed in the crates after a process upset in the 1960s. The crates were transported to the 212-N Building and had been in storage since 1972. In an effort to reduce the hazard categorization of 212-N the crates were removed from the building and Nondestructive Assay (NDA) was performed to characterize the crate contents meeting both Safeguards and Waste Management interests. A measurement system consisting of four configurable neutron slab detectors and high purity germanium (HPGe) detectors was deployed. Since no viable information regarding the waste matrix and configuration was available it was essential to correct for attenuation with a series of transmission measurements using californium and europium sources for both neutron and gamma applications. The gamma and neutron results obtained during this measurement campaign are compared and discussed in the paper.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RISK-INFORMED EXTERNAL HAZARDS ANALYSIS BY EEVE TOOLKIT

Introducing risk-informed safety analyses for external events can bring sensible benefits to the nuclear power industry easing the regulatory burden introduced in the aftermath of the Fukushima accident. In the framework of the US-DOE Light-Water Reactor Sustainability program, Risk-Informed Margin Characterization project (LWRS-RISMC), research activities were conducted at INL for developing and applying a toolkit for performing risk-informed external hazards analysis. The “EEVE” (External EVEnts) toolkit, a chain of INL and state-of-the-art codes, was set-up and applied for simulating earthquake-induced transients with internal flooding in a PWR. This was done using methodology set-up for evaluating new data and determining critical areas that would benefit most from advanced analysis methods. The methodology is agnostic and it can be applied to other external hazards than just seismic and flooding (e.g., high winds, intense precipitation, etc.). The first step was the deterministic calculations for evaluating the propagation of a set of earthquakes and for determining the effects on a fire suppression system in an auxiliary building. These deterministic calculations were performed using the LS-DYNA and the OPENSEE structural mechanics codes. Probability failures and event trees of a generic 3-loops Westinghouse PWR were derived from a generic SAPHIRE model. Seismically induced Loss of Offsite Power, Station Blackout, and fire suppression piping failure events were considered. SAPHIRE code allowed a pre-screening of all possible branches of the event tree and a selection of those with the largest Core Damage Frequency increase for further analysis using dynamic PRA methods. INL's EMRALD code performed dynamic PRA calculations of the identified sequences, integrating risk analysis with on-line deterministic safety analysis results (seismically-induced internal flooding calculations by NEUTRINO code and system analysis by RELAP5-3D code). RELAP5-3D Best-Estimate calculations coupled with RAVEN statistical code were used for deriving limit surfaces as function of relevant transient parameters. This data was used by EMRALD for determining the final core status (core damage/core safe). Finally, the coupling of seismic, flooding, system thermal-hydraulic, uncertainty quantification and probabilistic risk analysis for an advanced risk-informed external hazards analysis was demonstrated. Results showed the sensible decrease in the level of conservatism achieved using the developed risk-informed methodology, which allowed also improving the evaluation of the failure modes and failure probabilities of different components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Concept Design and Analysis of the Magnet System of the Sustained High Power Density Tokamak Facility

A recent National Academy study recommended a next-step sustained high power density (SHPD) facility for the United States that can be a bridge to a compact fusion pilot plant. A design has been initiated to investigate a possible SHPD non-deuterium-tritium device that builds upon recent low aspect ratio tokamak studies. Here, a 1.2-m device with a 2.4 aspect ratio has been chosen to evaluate physics performance goals within a double-null plasma machine arrangement centered on three component features: high current density toroidal field (TF) and central ohmic heating/poloidal field (PF) coils, liquid metal divertor/first wall systems, and the integration of a limited set of outboard dual-coolant lead lithium test blankets that can be maintained within a vertical maintenance approach.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Indoor air quality in 24 California residences designed as high-performance homes

Today’s high performance green homes are reaching previously unheard of levels of airtightness and are using new materials, technologies and strategies, whose impacts on Indoor Air Quality (IAQ) cannot be fully anticipated from prior studies. This research study used pollutant measurements, home inspections, diagnostic testing and occupant surveys to assess IAQ in 24 new or deeply retrofitted homes designed to be high performance green buildings in California. Although the mechanically vented homes were six times as airtight as non-mechanically ventilated homes (medians of 1.1 and 6.1 ACH 50 , n=11 and n=8, respectively), their use of mechanical ventilation systems and possibly window operation meant their median air exchange rates were almost the same (0.30 versus 0.32 hr -1 , n=8 and n=8, respectively). Pollutant levels were also similar in vented and unvented homes. In addition, these similarities were achieved despite numerous observed faults in complex mechanical ventilation systems. More rigorous commissioning is still recommended. Cooking exhaust systems were used inconsistently and several suffered from design flaws. Failure to follow best practices led to IAQ problems in some cases. Ambient nitrogen dioxide standards were exceeded or nearly so in four homes that either used gas ranges with standing pilots, or in Passive House-style homes that used gas cooking burners without venting range hoods. Homes without active particle filtration had particle count concentrations approximately double those in homes with enhanced filtration. The majority of homes reported using low-emitting materials; consistent with this, formaldehyde levels were approximately half those in conventional, new CA homes built before 2008. Emissions of ultrafine particles (with diameters <100 nm) were dramatically lower on induction electric cooktops, compared with either gas or resistance electric models. These results indicate that high performance homes can achieve acceptable and even exceptional IAQ by providing adequate general mechanical ventilation, using low-emitting materials, providing mechanical particle filtration, incorporating well-designed exhaust ventilation for kitchens and bathrooms, and educating occupants to use the kitchen and bath ventilation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Use of Unmanned Aerial Systems for Post-closure Waste Site Maintenance and Surveillance - 20143

The P- and R-Area Reactor buildings, located at SRS near Aiken, SC, were in-situ decommissioned by grouting below-grade portions of the buildings and demolishing some above-grade structures to grade level. Other reactor building structures were left above-grade and sealed to prevent human or animal access. Because the above grade-structures are expected to continue in their present state for hundreds of years, the condition of the building roofs is critical to mitigate rainwater intrusion. For this reason, building roof areas were strengthened with high strength concrete to ensure the long-term integrity of the roof structure. Periodic inspections of the roof structures are required to ensure that the roofs are functioning properly and to identify damage areas. The traditional method of inspecting closed reactor buildings requires the use of a helicopter and photographer to generate photographs and videos for review. This method proved sufficient but lacked the resolution and clarity that is required for a thorough inspection of the building structure. Fortunately, the Savannah River National Laboratory (SRNL) has established a Small Unmanned Aircraft System (sUAS) program using commercially available and custom-built remote-controlled aircraft. EC and ACP contacted the SRNL program to evaluate whether the sUAS technology could be employed for periodic reactor building inspections. The sUAS can fly within a few meters of the reactor buildings and hover, allowing for a more thorough aerial inspection. The initial sUAS inspection of the P-Area Reactor building was completed in February 2018 and at the R-Area Reactor building in August 2018 and were successful in providing higher resolution photos and videos. The sUAS inspections also revealed that vegetation had begun to grow on the roofs that could potentially damage the structure integrity. SRNL partnered with Virginia Polytechnic Institute and State University to build a custom heavy lift sUAS that could be equipped with herbicides to remotely treat the vegetative growth. Herbicides were successfully applied to the R-Area Reactor building roof using the custom sUAS in September 2018. The use of unmanned aircraft systems at SRS to perform aerial inspections and herbicide treatment in otherwise inaccessible areas has proven to be an efficient and cost-effective technology that provides high value, increases knowledge of facility conditions, and provides for early detection of damage. Periodic inspections of the reactor building roofs using sUAS technology are performed safely, efficiently, and at a significant cost and schedule savings while reducing emissions, noise, and fossil fuel use. The use of sUAS equipment for building inspections and herbicide application at SRS is unique within the DOE complex. The goal of SRS is to apply this remote technology to other waste unit operations and maintenance activities in the future. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Interpreting Write Performance of Supercomputer I/O Systems with Regression Models

This work seeks to advance the state of the art in HPC I/O performance analysis and interpretation. In particular, we demonstrate effective techniques to: (1) model output performance in the presence of I/O interference from production loads; (2) build features from write patterns and key parameters of the system architecture and configurations; (3) employ suitable machine learning algorithms to improve model accuracy. We train models with five popular regression algorithms and conduct experiments on two distinct production HPC platforms. We find that the lasso and random forest models predict output performance with high accuracy on both of the target systems. We also explore use of the models to guide adaptation in I/O middleware systems, and show potential for improvements of at least 15% from model-guided adaptation on 70% of samples, and improvements up to 10× on some samples for both of the target systems.

Xie, Bing↗

K-25 D and D Challenges - 12170

Decontamination and decommissioning (D and D) of the K-25 former gaseous diffusion plant provides lessons learned applicable to other D and D projects in the DOE Complex. The 175,000- square-meter, 1.6-kilometer-long building is contaminated with highly enriched uranium (HEU), Tc-99, trace quantities of other fission products, asbestos, PCBs, and other hazardous wastes. Safety challenges include deteriorated electrical systems, significant structural degradation, and criticality and exposure risks. The project completely revised the D and D approach after a worker fell through an operating floor and was seriously injured. For protection from deteriorated building conditions, the project reduced the number of workers in the facility, limited their hours in the building, and installed nets and barriers to protect them from falls through weakened floors and from falling material. The new plan involved removing high-risk components, removing motors and compressors, and demolishing the building from the outside with heavy equipment with most of the piping and components inside the building during demolition. The team provided temporary electrical power; reconfigured the criticality alarm system; upgraded security; performed sampling and analysis to locate and characterize HEU deposits and Tc-99; and, to establish 'criticality incredible' conditions, conducted a nondestructive assay program and injected foam into equipment and piping as a contamination fixative. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measure Guideline: Basement Insulation Basics

This guideline is intended to describe good practices for insulating basements in new and existing homes, and is intended to be a practical resources for building contractors, designers, and also to homeowners. These flowcharts are provided as a very high-level overview of the planning and selection process for basement insulation systems. Note that these guidelines—and certainly these charts—are not exhaustive. Many references are provided that discuss several viable basement systems as well as achieving thermal performance well above code minimums.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗