Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Helium cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

MHD Analysis of Dual-Coolant Lead-Lithium Blanket for Spherical Tokamak Advanced Reactor

The tritium breeding blanket is vital for future fusion power plants, with the Spherical Tokamak Advanced Reactor (STAR) project highlighting the dual-coolant lead-lithium (DCLL) design. The DCLL blanket performs shielding, energy exhaust, and tritium breeding using a lead-lithium alloy , with lithium as the breeder and lead as the neutron multiplier. It also serves as the primary coolant, with helium providing supplemental cooling. Reduced-activation ferritic/martensitic steel is used for the blanket structure. Magnetohydrodynamic (MHD) phenomena influence the liquid metal flow in a magnetic field, affecting heat transfer in the breeder affected by energetic neutrons. Understanding key flow parameters in such conditions is critical for efficient DCLL design. This study uses three-dimensional thermofluid MHD analysis with ANSYS CFX software, modified at Princeton Plasma Physics Laboratory, to simulate high Hartmann flows. The neutronics code MCNP, coupled with plasma equilibrium, provides heat source distribution. In conclusion, we examine electromagnetic interactions in adjacent fluid domains and analyze the magnetic field’s impact on flow distribution in the inboard and outboard blanket layout, using detailed mesh generation for accurate results.

DCLL↗

Construction of Cryogen-Free 4.3T Superconducting Wiggler for NSLS-II Ring

With the 3 GeV electron beam energy for the National Synchrotron Light Source II (NSLS-II) ring, only superconducting wigglers (SCW) producing greater than 4T peak field can cover the photon energy range of 20 keV and 200 keV with sufficient number of photons. The High energy Engineering X-ray (HEX) Diffraction beamline, which is primarily funded by the New York State Energy Research and Development Authority (NYSERDA) and NSLS-II, will be equipped with a 1.2m-long SCW with 70 mm period length and 4.3 T on-axis field. This SCW is free from the use of liquid Helium and is cooled only with cryo-coolers. The Electron Beam Chamber (EBC) with vertical aperture of 8 mm is made from 316LN stainless steel and copper plating is applied both surface and +-12.5mm wide from the center in the inner surface. The expected heat load from the electron beam of the NSLS-II ring is estimated to be 10 W/m. Here, we describe the design principles and engineering challenges for the device.

36 MATERIALS SCIENCE↗

Quench Analysis of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

The 2.0 T superconducting solenoid magnet (MARCO) being designed to be built for the EIC central detector (ePIC). Here, the magnet consists of three set of coil in a vacuum impregnated coil pack. Each coil pack consists of a total 554 turns winding wrapped with 6 layers of winding per coil. The coil case assembly is cooled by supercritical helium at 4.6 K. This manuscript presents quench analysis carried out on the magnet system along with the conductor stability. For the normal operation the magnet at 4.6 K and at normal operating current, the quench evaluation is carried out at 4.7 K for design assessment. The quench analysis carried out using commercial multi-physics FEA tool along an equivalent single coil quench model and the requirements for the magnet protection is also presented.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗

Electron beam irradiation of 1,4 dioxane

Electron beam irradiation produces both, reducing and oxidizing species which facilitate the reduction of contaminants found in water and wastewater. To investigate the impact of electron beam on 1,4-dioxane, a widely used solvent which has been declared as a probable human carcinogen by the U.S. Environmental Protection Agency, a beamline was designed and commissioned at the Upgraded Injector Test Facility at Jefferson Lab. Here, wastewater samples can be irradiated with a beam energy up to 10 MeV and a beam current of up to 100 nA. Beam acceleration is achieved by two superconducting radio-frequency cavities cooled by liquid helium in a cryomodule. A beam spot with a diameter of ~5 cm was produced at the target location using a pair of raster coils. Electron beam irradiation studies were performed using 1,4-dioxane in two different matrices, de-ionized water and secondary effluent wastewater, and for two concentrations, 10 microg/L and 100 microg/L. The concentration of 1,4-dioxane after irradiation was measured as a function of dose.

Li, Xi↗

Modeling and Analysis Support for Acceleratro-based Production of Mo-99

NorthStar Medical Radioisotopes, LLC, is in the process of commissioning a medical isotope production facility, which will use high-power electron accelerators to produce molybdenum-99 (Mo-99), the parent of technetium-99m (Tc-99m), through photonuclear reactions in molybdenum-100 (Mo-100). In this approach, a target comprising multiple thin disks of enriched molybdenum metal is bombarded with a 40-MeV electron beam. Electrons that impinge on the molybdenum target produce bremsstrahlung x-rays that cause the nuclear reaction. Because enriched Mo-100 is expensive, there is a desire to use as much beam power as possible to achieve maximum production yield and minimize the size of the target. This requirement leads to very high beam power density (heat deposition in the target), which creates challenging requirements for target cooling. In the latest concept developed by NorthStar, a stack of target (sintered molybdenum) disks is irradiated from two sides by a 40-MeV electron beam, with a total power of 250 kW (125 kW from each side). The target disks are cooled by pressurized helium gas flowing through channels between the disks. Inconel windows in the target housing form a pressure boundary between the helium within the housing and the evacuated beam tube.

07 ISOTOPE AND RADIATION SOURCES↗

Traveling-wave photodetector has sub-nanosecond response

Mercury-doped germanium photodetector uses waveguide which increases the absorption of microwave energy within the photodetectors. Waveguide and photodetector are placed in liquid helium Dewar and cooled. A carbon dioxide laser is light source and klystron provides microwave energy. Measured response times are approximately 1 nanosecond.

Sun, C.↗

Liquid neon heat transfer as applied to a 30 tesla cryomagnet

Since superconducting magnets cooled by liquid helium are limited to magnetic fields of about 18 teslas, the design of a 30 tesla cryomagnet necessitates forced convection liquid neon heat transfer in small coolant channels. As these channels are too small to handle the vapor flow if the coolant were to boil, the design philosophy calls for suppressing boiling by subjecting the fluid to high pressures. Forced convection heat transfer data are obtained by using a blowdown technique to force the fluid vertically through a resistance-heated instrumented tube. The data are obtained at inlet temperatures between 28 and 34 K and system pressures between 28 to 29 bars. Data correlation is limited to a very narrow range of test conditions, since the tests were designed to simulate the heat transfer characteristics in the coolant channels of the 30 tesla cryomagnet concerned. The results can therefore be applied directly to the design of the magnet system.-

Papell, S. S.↗

Low gravity phase separator

An apparatus is described for phase separating a gas-liquid mixture as might exist in a subcritical cryogenic helium vessel for cooling a superconducting magnet at low gravity such as in planetary orbit, permitting conservation of the liquid and extended service life of the superconducting magnet.

Smoot, G. F.↗

Strategy for the IRAS all-sky survey

IRAS (the Infrared Astronomical Satellite) was launched on January 25, 1983 (January 26 GMT) with the primary purpose of performing an infrared survey of the entire celestial sphere. To ensure completeness and reliability, every point of sky was to be covered by a minimum of four separate scans of the telescope field-of-view, and as much as possible with six, with certain added timing constraints on the elapsed interval between scans. These strong requirements for sky coverage, combined with a restricted, rotating viewing-window, made extensive planning for the survey strategy, both pre-launch and during operations, a necessity. The result was that on November 21 (November 22 GMT), when the liquid helium required for cooling was depleted, 96 percent of the sky was covered to the minimum depth of four and 71 percent was coverd to depth six or more.

Lundy, S. A.↗

Hinge spectrometer - A grating Fabry-Perot instrument for far-infrared/submillimeter spectroscopy in space

A compact submillimeter spectrometer can be constructed through the use of a combination of grating and Fabry-Perot techniques. The instrument has only one moving part, a grating that pivots about an accurately placed hinge. The entire optical train is cooled to liquid helium temperature for low-background low-noise operation and is designed for use in astronomical observations from aircraft, balloons, or space vehicles. Resolving power R about 20,000 at about 150 microns is demonstrated.

Harwit, Martin↗

32-GHz Wideband Maser Amplifier

High-gain, wideband, microwave amplifier based on ruby cooled by liquid helium. Features include low input equivalent noise temperature and 400-MHz bandwidth. Design basically extension of previous reflected-wave masers built for frequency range of 18 to 26 GHz. Maser amplifier includes eight stages connected in reflected-wave configuration. Particularly useful for detection of weak microwave signals in radio astronomy and communications.

Shell, J. S.↗

LWIR scene simulator developed for end-to-end performance evaluation of focal planes

The development of a long-wave infrared optical simulator facilitates evaluation of the end-to-end performance of long wavelength infrared (LWIR) focal plane arrays (FPAs) in a system-like environment. This simulator provides selectable structured scene inputs to a focal plane module or array. Background irradiances as low as 10 exp 10 photons/sq cm s are achievable when the simulator is cooled with liquid helium. The optical simulator can generate single or multiple targets of controllable intensities, and uniform or structured background irradiances. The infrared scenes can be viewed in a stationary mode or dynamically scanned across the focal plane.

Thompson, Niels A.↗

The No Vibrational Fundamental Band: Temperature Dependence of N2-Broadening Coefficients

Rovibrational spectra of the vibrational fundamental of nitric oxide have been recorded under N2-broadening conditions at 0.0056 cm(exp-1) resolution using the Solar McMath FTS at the Kitt Peak National Observatory. The temperature range for the experiments was 296 K to 183 K. The 30 cm absorption cell used for the measurements is cooled with a helium compressor and can operate at temperatures down to 60 K; vibration isolation of the cell allows its use with high performance Fourier Transform Spectrometers. From these spectra, N2-broadened line widths have been determined thru m = 16.5. Qualitative as well as quantitative discrepancies are observed between our experimental determinations of the temperature dependence of the broadening and theoretical calculations.

Spencer, M. N.↗

Fullerene Machines

Recent computational efforts at NASA Ames Research Center and computation and experiment elsewhere suggest that a nanotechnology of machine phase functionalized fullerenes may be synthetically accessible and of great interest. We have computationally demonstrated that molecular gears fashioned from (14,0) single-walled carbon nanotubes and benzyne teeth should operate well at 50-100 gigahertz. Preliminary results suggest that these gears can be cooled by a helium atmosphere and a laser motor can power fullerene gears if a positive and negative charge have been added to form a dipole. In addition, we have unproven concepts based on experimental and computational evidence for support structures, computer control, a system architecture, a variety of components, and manufacture. Combining fullerene machines with the remarkable mechanical properties of carbon nanotubes, there is some reason to believe that a focused effort to develop fullerene nanotechnology could yield materials with tremendous properties.

Globus, Al↗

Qualifying the Sunpower M87N Cryocooler for Operation in the AMS-02 Magnetic Field

The Alpha Magnetic Spectrometer-02 (AMs-02) experiment uses a superfluid helium dewar to cool a large superconducting magnet. The outer vapor-cooled shields of the dewar are to be held at 80 K by four Sunpower M87N cryocoolers. These cryocoolers have magnetic components that might interact with the external applied field generated by the superconducting magnet, thereby degrading the cryocoolers' performance. Engineering models of the Sunpower M87 have been qualified for operation in a magnetic environment similar to the AMs-02 magnetic environment. Although there was no noticeable performance degradation at field levels that were comparable to AMs-02 field levels, there appears to be a small performance degradation at higher field levels. It was theorized that there were three possible issues related to these performance losses at high magnetic fields: i) induced piston rubbing on the cylinder wall due to forces and torques on the linear motor due to the applied magnetic fields; ii) Magnetic hysteretic and/or eddy current damping of the balancer due to its motion in the applied magnetic fields; iii) Inductance losses in motor due to the applied magnetic field. The experiments conducted at the Massachusetts Institute of Technology (MIT) cyclotron facility in June 2002 were designed to test these. Tests were performed over a range of field levels that were lower, comparable, and higher than the field levels that the cryocoolers will experience in the AMs-02 operating environment. This paper describes the experiments and the inferences derived from them.

Mustafi, Shuvo↗

THz Instrumentation for the Herschel Space Observatory's Heterodyne Instrument for Far Infrared

The Heterodyne Instrument for Far Infrared (HIFI) on ESA's Herschel Space Observatory utilizes a variety of novel RF components in its five SIS receiver channels covering 480-1250 GHz and two HEB receiver channels covering 1410-1910 GHz. The local oscillator unit will be passively cooled while the focal plane unit is cooled by superfluid helium and cold helium vapors. HIFI employs W-band GaAs amplifiers, InP HEMT low noise IF amplifiers, fixed tuned broadband planar diode multipliers, high power W-bapd Isolators, and novel material systems in the SIS mixers. The National Aeronautics and Space Administration through the Jet Propulsion Laboratory is managing the development of the highest frequency (1119-1250 GHz) SIS mixers, the local oscillators oscillators for the three highest frequency receivers as well as W-band power amplifiers, high power W-band isolators, varactor diode devices for all high frequency multipliers and InP HEMT components for all the receiver channels intermediate frequency amplifiers. The NASA developed components represent a significant advancement in the available performance. This paper presents an update of the performance and the current state of development.

local oscillators↗

James Webb Space Telescope Integrated Science Instrument Module Thermal Balance/Thermal Vacuum Test Configuration and Test Planning at NASA's Goddard Space Flight Center

The James Webb Space Telescope (JWST) is the next of the great observatories , scheduled to be launched in 2014. Three of the four science instruments are passively cooled to their operational temperature range of 36K to 40K, and the fourth instrument is actively cooled to its operational temperature of approximately 6K. Thermal-vacuum testing of the flight science instruments at the Integrated Science Instrument Module (ISIM) element level will take place within a newly constructed shroud cooled by gaseous helium inside Goddard Space Flight Center s (GSFC) Space Environment Simulator (SES). The test enclosure surrounding the instruments during the integrated ISIM-level thermal balance testing is complex, and is designed to simulate as closely as possible the in-flight conductive and radiative thermal environment around the ISIM. Thermal control and measurement of parasitic sources of heat leak into the test volume is critical, as the dissipation plus known parasitics in the flight ISIM is approximately 454 mW, and additional parasitics attributed to the flight enclosure itself are nearly equal to this, resulting in the energy balance of the inflight ISIM being less than 1.0 W. Sources of test-induced parasitics must be carefully controlled and measured, and the ability to thermally control the test environment is critical to enable accurate thermal balance testing and thermal model correlation. This paper describes the test configuration and plans for the ISIM-level thermal vacuum/thermal balance testing at GSFC.

Glazer, Stuart↗

Cryogenic Thermal Vacuum Testing with Remote Optical Metrology

Flexure Engineering was awarded an SBIR to research and develop technology needed to build a thermal vacuum chamber made to take laser radar metrology through a window. The XATF test is proof of concept for this, and demonstrated the need for such a chamber. XATF refers to two pieces of critical ground support equipment for NASA's JWST (James Webb Space Telescope) Integrated Science Instrument Module (ISIM), the ISIM Alignment Target Fixture (IATF) and the Master Alignment Target Fixture (MATF). These optical alignment assemblies require characterization while under cryogenic temperature. A thermal vacuum chamber equipped with a shroud cooled with gaseous and liquid nitrogen was used. An inner shroud was cooled with liquid helium to approximately 30K. The XATF assemblies were kinematically mounted and oriented inside the inner shroud such that the optical targets were visible from outside an optical window on one of the chamber ports. Laser radar and theodolite mounted outside the window took measurements of various optical targets. Two cold cycles were completed. A third cycle was aborted. Metrology was successfully taken. There were some problems with the helium system. The cryo pumps were turned off to reduce vibrations during metrology. Many new technologies and testing methods must be developed for JWST and future programs that will require precision measurements. These technologies will be applicable to other cold temperature applications, such as lunar missions and superconductors. Remote metrology technologies can also be applicable to testing in harsh environments. Facilities with remote metrology capability will be valuable.

Boyd, Guinevere↗