Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HYDROGEN STATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Hydrogen quantitative risk assessment workshop proceedings.

The Quantitative Risk Assessment (QRA) Toolkit Introduction Workshop was held at Energetics on June 11-12. The workshop was co-hosted by Sandia National Laboratories (Sandia) and HySafe, the International Association for Hydrogen Safety. The objective of the workshop was twofold: (1) Present a hydrogen-specific methodology and toolkit (currently under development) for conducting QRA to support the development of codes and standards and safety assessments of hydrogen-fueled vehicles and fueling stations, and (2) Obtain feedback on the needs of early-stage users (hydrogen as well as potential leveraging for Compressed Natural Gas [CNG], and Liquefied Natural Gas [LNG]) and set priorities for %E2%80%9CVersion 1%E2%80%9D of the toolkit in the context of the commercial evolution of hydrogen fuel cell electric vehicles (FCEV). The workshop consisted of an introduction and three technical sessions: Risk Informed Development and Approach; CNG/LNG Applications; and Introduction of a Hydrogen Specific QRA Toolkit.

97 MATHEMATICS AND COMPUTING↗

System-of-systems optimization of hydrogen infrastructure for heavy-duty freight corridors: The interstate 10 case study

Medium and heavy-duty freight transportation requires hydrogen energy infrastructure that is cost-effective, operationally reliable, spatially coherent, and resilient to demand variability along major corridors. This paper presents an integrated hydrogen corridor planning framework using Oak Ridge National Laboratory's OR-AGENT that couples freight-driven, route-resolved hydrogen demand modeling with optimized station siting, sizing, and station-level techno-economic analysis. The framework is demonstrated for the Interstate 10 freight corridor and the Houston-to-Los-Angeles region. Hydrogen demand is derived from high-resolution origin–destination freight data, duty-cycle characterization, and physics-based energy consumption modeling. Candidate refueling sites are selected from existing heavy-duty diesel fueling locations and optimized subject to onboard storage and station capacity constraints. Resulting station throughputs are evaluated using established techno-economic models for electrolytic hydrogen production and dispensing infrastructure. Results show that a regional, portfolio-level aggregation, average dispensed electrolytic hydrogen cost of $6.87–$7.26/kg is currently feasible, and is strongly influenced by demand density and utilization.

Sujan, Vivek [ORNL] (ORCID:0000000269882342)↗

Refueling Infrastructure Scoping and Feasibility Assessment for Hydrogen Rail Applications

The feasibility and component cost of hydrogen rail refueling infrastructure is examined. Example reference stations can inform future studies on components and systems specifically for hydrogen rail refueling facilities. All of the 5 designs considered assumed the bulk storage of liquid hydrogen on-site, from which either gaseous or liquid hydrogen would be dispensed. The first design was estimated to refuel 10 multiple unit trains per day, each train containing 260 kg of gaseous hydrogen at 350 bar on-board. The second base design targeted the refueling of 50 passenger locomotives, each with 400 kg of gaseous hydrogen on-board at 350 bar. Variations from this basic design were made to consider the effect of two different filling times, two different hydrogen compression methods, and two different station design approaches. For each design variation, components were sized, approximate costs were estimated for major components, and physical layouts were created. For both gaseous hydrogen-dispensing base designs, the design of direct-fill using a cryopump design was the lowest cost due to the high cost of the cascade storage system and gas compressor. The last three base designs all assumed that liquid hydrogen was dispensed into tender cars for freight locomotives that required 7,500 kg of liquid hydrogen, and the three different designs assumed that 5, 50, or 200 tender cars were refueled every day. The total component costs are very different for each design, because each design has a very different dispensing capacity. The total component cost for these three designs are driven by the cost of the liquid hydrogen tank; additionally, delivering that much liquid hydrogen to the refueling facility may not be practical. Many of the designs needed the use of multiple evaporators, compressors, and cryopumps operating in parallel to meet required flow rates. In the future, the components identified here can be improved and scaled-up to better fit the needs of heavy-duty refueling facilities. This study provides basic feasibility and first-order design guidance for hydrogen refueling facilities serving emerging rail applications.

08 HYDROGEN↗

Simulating Future GPS Clock Scenarios with Two Composite Clock Algorithms

Using the GPS Toolkit, the GPS constellation is simulated using 31 satellites (SV) and a ground network of 17 monitor stations (MS). At every 15-minutes measurement epoch, the monitor stations measure the time signals of all satellites above a parameterized elevation angle. Once a day, the satellite clock estimates the station and satellite clocks. The first composite clock (B) is based on the Brown algorithm, and is now used by GPS. The second one (G) is based on the Greenhall algorithm. The composite clock of G and B performance are investigated using three ground-clock models. Model C simulates the current GPS configuration, in which all stations are equipped with cesium clocks, except for masers at USNO and Alternate Master Clock (AMC) sites. Model M is an improved situation in which every station is equipped with active hydrogen masers. Finally, Models F and O are future scenarios in which the USNO and AMC stations are equipped with fountain clocks instead of masers. Model F is a rubidium fountain, while Model O is more precise but futuristic Optical Fountain. Each model is evaluated using three performance metrics. The timing-related user range error having all satellites available is the first performance index (PI1). The second performance index (PI2) relates to the stability of the broadcast GPS system time itself. The third performance index (PI3) evaluates the stability of the time scales computed by the two composite clocks. A distinction is made between the "Signal-in-Space" accuracy and that available through a GNSS receiver.

global positioning system↗

Cesium Removal at Fukushima Nuclear Plant - 13215

The Great East Japan Earthquake that took place on March 11, 2011 created a number of technical challenges at the Fukushima Daiichi Nuclear Plant. One of the primary challenges involved the treatment of highly contaminated radioactive wastewater. Avantech Inc. developed a unique patent pending treatment system that addressed the numerous technical issues in an efficient and safe manner. Our paper will address the development of the process from concept through detailed design, identify the lessons learned, and provide the updated results of the project. Specific design and operational parameters/benefits discussed in the paper include: - Selection of equipment to address radionuclide issues; - Unique method of solving the additional technical issues associated with Hydrogen Generation and Residual Heat; - Operational results, including chemistry, offsite discharges and waste generation. Results show that the customized process has enabled the utility to recycle the wastewater for cooling and reuse. This technology had a direct benefit to nuclear facilities worldwide. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimizing Long Term Hydrogen Fueling Infrastructure Plans on Freight Corridors for Heavy Duty Fuel Cell Electric Vehicles

The development of a future hydrogen energy economy will require the development of several hydrogen market and industry segments including a hydrogen based commercial freight transportation ecosystem. For a sustainable freight transportation ecosystem, the supporting fueling infrastructure and the associated vehicle powertrains making use of hydrogen fuel will need to be co-established. This paper develops a long-term plan for refueling infrastructure deployment using the OR-AGENT (Optimal Regional Architecture Generation for Electrified National Transportation) tool developed at the Oak Ridge National Laboratory, which has been used to optimize the hydrogen refueling infrastructure requirements on the I-75 corridor for heavy duty (HD) fuel cell electric commercial vehicles (FCEV). This constraint-based optimization model considers existing fueling locations, regional specific vehicle fuel economy and weight, vehicle origin and destination (OD), vehicle volume by class and infrastructure costs to characterize in-mission refueling requirements for a given freight corridor. The authors applied this framework to determine the ideal long term public access locations for hydrogen refueling (constrained by existing fueling stations and dispensing technology), the minimal viable cost to deploy sufficient hydrogen fuel dispensers, and associated equipment, to accommodate a growing population of hydrogen fuel cell trucks. So the framework discussed in this paper can be expanded and applied to additional electrified powertrains as well as a larger interstate system, expanded regional corridor, or other transportation networks.

08 HYDROGEN↗

Hydrogen Storage System Cost Analysis (2017-2021) (Final Report)

This final technical report summarizes hydrogen storage system cost analysis results from 2017-2021. Results include onboard hydrogen storage system costs for light-duty vehicles, medium-duty vehicles, heavy-duty vehicles, class 8 long haul trucks, and passenger buses. Multiple storage systems are included, primarily focusing on compressed and cryo-compressed hydrogen in Type 3 and Type 4 storage systems. Additional analysis includes large-scale gaseous and liquid hydrogen storage at refueling stations in tube trailers and Dewars; advanced materials-based storage systems such as metal organic frameworks and metal hydrides; and a baseline setting analysis of compressed natural gas storage systems in support of the Institute for Advanced Composites Manufacturing Initiative (IACMI). Analyses were primarily conducted using a Design for Manufacture and Assembly ® methodology, which is a bottom-up process-based approach to estimating factory costs. Multiple annual production rates are reported to project high-volume costs relevant to mature markets.

08 HYDROGEN↗

CSULA Hydrogen Refueling Facility Performance Evaluation and Optimization

Throughout its history, Cal State LA has been in the forefront of advanced energy and transportation technologies. The station is located at the intersection of two major highways in Los Angeles region and has a convenient access. It is capable of producing up to 60 kg/day and can fuel 15-20 vehicles per day. Cal State LA had partnered with DOE to establish a robust station operation and performance data collection program. This consisted of equipping the station with additional instrumentation and collecting fueling performance data for several years. The data was further furnished to NREL for processing and agglomeration with data from other stations. In addition to fueling, maintenance and failure events were shared as well as hydrogen purity reports. The station has also undergone several upgrades in fueling protocols and hardware for improved performance and code compliance.

08 HYDROGEN↗

Data requirements for improving the Quantitative Risk Assessment of liquid hydrogen storage systems

Quantitative Risk Assessment (QRA) supports the development of risk-informed safety codes and standards which are employed to enable the safe deployment of hydrogen technologies essential to decarbonize the transportation sector. System reliability data is a necessary input for rigorous QRA. Here, the lack of reliability data for bulk liquid hydrogen (LH 2 ) storage systems located on site at fueling stations limits the use of QRAs. In turn, this hinders the ability to develop the necessary safety codes and standards that enable worldwide deployment of these stations. Through a QRA-based analysis of a LH 2 storage system, this work focuses on identifying relevant scenario and probability data currently available and ascertaining future data collection requirements regarding risks specific to liquid hydrogen releases. The work developed consists of the analysis of a general bulk LH 2 storage system design located at a hydrogen fueling station. Failure Mode and Effect Analysis (FMEA) and traditional QRA modeling tools such as Event Sequence Diagrams (ESD) and Fault Tree Analysis (FTA) are employed to identify, rank, and model risk scenarios related to the release of LH 2 . Based on this analysis, scenario and reliability data needs to add LH 2 -related components to QRA are identified with the purpose of improving the future safety and risk assessment of these systems.

08 HYDROGEN↗

California: California's Clean Energy Resources and Economy [Brochure]

California is remarkably well positioned to compete in the global race for clean energy. It is second in the nation among states with renewable power capacity, contains multiple renewable energy resources from all types of renewable energy, and is the nation’s leader in solar, biomass, and geothermal power generation. For example, California has the most solar photovoltaic installations in the country and is a leader in wind energy. It added more new wind power than any other state in 2011, and wind now makes up 4% of the state’s electricity generation. The state also takes advantage of abundant hydroelectric resources from California rivers. California is also a perennial leader in energy efficiency investment, leading the country with $\$$1.1 billion in utility investment for energy efficiency programs in 2010. Investment from 2010–2012 is expected to yield savings of nearly 7,000 gigawatt hours of electricity. The state has set unprecedented energy efficiency standards for appliances, equipment, and residential and commercial buildings. For example, the recently approved 2013 Building Energy Efficiency Standards will result in 25% and 30% more efficient residential and commercial construction standards respectively than those that they will be replacing, providing more savings for California energy users.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solid polymer electrolyte water electrolysis system development

Solid polymer electrolyte technology used in a water electrolysis system (WES) to generate oxygen and hydrogen for manned space station applications was investigated. A four-man rated, low pressure breadboard water electrolysis system with the necessary instrumentation and controls was fabricated and tested. A six man rated, high pressure, high temperature, advanced preprototype WES was developed. This configuration included the design and development of an advanced water electrolysis module, capable of operation at 400 psig and 200 F, and a dynamic phase separator/pump in place of a passive phase separator design. Evaluation of this system demonstrated the goal of safe, unattended automated operation at high pressure and high temperature with an accumulated gas generation time of over 1000 hours.

Source record↗

Nickel-Hydrogen Battery Cell Life Test Program Update for the International Space Station

NASA and Boeing North America are responsible for constructing the electrical power system for the International Space Station (ISS), which circles the Earth every 90 minutes in a low Earth orbit (LEO). For approximately 55 minutes of this orbit, the ISS is in sunlight, and for the remaining 35 minutes, the ISS is in the Earth s shadow (eclipse). The electrical power system must not only provide power during the sunlight portion by means of the solar arrays, but also store energy for use during the eclipse. Nickel-hydrogen (Ni/H2) battery cells were selected as the energy storage systems for ISS. Each battery Orbital Replacement Unit (ORU) comprises 38 individual series-connected Ni/H2 battery cells, and there are 48 battery ORU s on the ISS. On the basis of a limited Ni/H2 LEO data base on life and performance characteristics, the NASA Glenn Research Center at Lewis Field commenced testing through two test programs: one in-house and one at the Naval Surface Warfare Center in Crane, Indiana.

Miller, Thomas B.↗

Flywheel Energy Storage Technology Being Developed

A flywheel energy storage system was spun to 60,000 rpm while levitated on magnetic bearings. This system is being developed as an energy-efficient replacement for chemical battery systems. Used in groups, the flywheels can have two functions providing attitude control for a spacecraft in orbit as well as providing energy storage. The first application for which the NASA Glenn Research Center is developing the flywheel is the International Space Station, where a two-flywheel system will replace one of the nickel-hydrogen battery strings in the space station's power system. The 60,000-rpm development rotor is about one-eighth the size that will be needed for the space station (0.395 versus 3.07 kWhr).

Wolff, Frederick J.↗

Investigation into the High Voltage Shutdown of the Oxygen Generator System in the International Space Station

The Oxygen Generation System (OGS) Hydrogen Dome Assembly Orbital Replacement Unit (ORU) serial number 00001 suffered a cell stack high-voltage shutdown on July 5, 2010. The Hydrogen Dome Assembly ORU was removed and replaced with the on-board spare ORU serial number 00002 to maintain OGS operation. The Hydrogen Dome Assembly ORU was returned from ISS on STS-133/ULF-5 in March 2011 with test, teardown and evaluation (TT&E) and failure analysis to follow.

Carpenter, Joyce E.↗