Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HOUSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Rotating housing turbine

The invention is a new turbine structure having a housing that rotates. The housing has a sidewall, and turbine blades are attached to a sidewall portion. The turbine may be completely open in the center, allowing space for solids and debris to be directed out of the turbine without jamming the spinning blades/sidewall. The turbine may be placed in a generator for generation of electrical current.

33 ADVANCED PROPULSION SYSTEMS↗

NexusHaus: Solar Decathlon House

The University of Texas at Austin and The Technical University of Munich 2015 Solar Decathlon house is called Nexushaus because it combines UT Austin and TUM students in an affordable modular residential green building in the context of Austin, Texas, based on shape forming principles found in nature that demonstrates transformative technologies in Zero Net Energy, Zero Net Water and Carbon Neutrality. To meet the needs of the competition, a portable modular design has been developed with an assembly that enables ease of installation and both quantitative and qualitative performance in the design. The prefabricated house sits lightly on the land and forms the superstructure for photovoltaic technologies, rainwater collection, aquaculture and permaculture gardening and indoor/outdoor living. The ultimate goal of Nexushaus is to serve as a potential prototype for a next-generation modular home that could be reproduced in mass in an assembly plant in Austin.

solar decathlon, zero net energy, zero net water, ↗

A simplified regression building thermal modelling method for detached two-floor house in U.S.

The residential building sector accounts for approximately 37% of total U.S. electricity consumption. Within the residential building sector, heating and cooling is the main target for peak load shifting/reduction since it is the largest contributor to peak demand. In fact, the flexibility of residential HVAC loads can provide continuous variation of demand to provide grid services by varying their demand over a baseline. The performance of HVAC load control to provide grid services relies heavily on the accuracy of indoor air temperature or cooling/heating demand predictions and therefore the quality of building model. Besides forward models, popular building models are data-driven models which can be broken down into two categories: gray-box model, e.g. Resistance-Capacitance (RC) model and black-box model. RC model, also called lumped capacitance or network model, which is constituted with electrical analogue pattern with resistance (R) and capacitance (C). In general, RC models require considerable computation burden and long periods of data to train limited number of model coefficients. Black-box models have gained increasing interest due to their capability in analyzing large-scale data and flexibility in practical applications. But, the data-mining based (machine learning algorithms/techniques based) models tend to have invisible model structures which poses a problem when trying to use the model for optimal control or model predictive control of the HVAC system. Hence, there is a continuing need for efficient online system identification techniques, which can provide explicit parameters for the model. Traditional regression models fit well for this specific purpose. This paper presents an innovative way to predict average indoor temperature in separate floors of typical detached residential house. A rolling horizon linear regression model, which includes online adaptive correction component, is proposed to predict the temperature difference between downstairs and upstairs. A RC model is used to predict the overall mean indoor air temperature. Since the adaptive algorithm needs to be implemented online, a less computation-demanding polynomial fitting algorithm is adopted. This kind of fitting problem can be cast as linear regression problem with multiple variables, parameters of which can be efficiently obtained by well-known gradient descent method.The validation is conducted by comparing the predicted results with the results from data-mining based models as well as measured data from a real typical detached two-floor house. The results show that the developed method has satisfactory performance in predicting the building indoor temperature in 1st and 2nd floors.

Cui, Borui↗

Attachment of cylinders in the housing of free-piston stirling machines

An improvement to a free-piston Stirling machine having a cylinder mounted within a housing. The cylinder has a flange for mounting the cylinder within the housing to a transition plate with a central opening for receiving the cylinder. An elastic rim bounds and surrounds the opening and extends in an axial direction from the plate to a crest of the rim. The crest of the rim is in contact against a first axially facing side of the cylinder flange. The interior side of the rim is outwardly spaced from the exterior side of the cylinder. A compliant clamp is attached to the transition plate and is positioned on the opposite, axially facing side of the cylinder flange. The compliant clamp has an elastic spring extending against the cylinder flange which applies a force urging the cylinder flange in an axial direction against the crest of the elastic rim.

Cale, E. Todd↗

Using the Monte Carlo Method to Evaluate the Reliability of Screening Multifamily Housing for Radon

When screening for radon in a multifamily housing complex using a fixed sample density (e.g., testing 1 in 10 (10%) or 1 in 4 units (25%)), the statistical confidence is dependent upon the assumed elevated radon frequency. For example, testing 25% of units in a complex estimated to have eight units with elevated radon levels will provide 90% confidence. However, if it is assumed that, in the same complex, there are only three units with elevated radon levels, the confidence drops to around 58% for the same sample density. Furthermore, in the previous example, if elevated radon levels are not found during the screening, all that can be stated is that the screening provides 90% confidence that there are no more than seven units in the complex with elevated radon levels. To more fully illustrate this uncertainty, ten separate multifamily housing radon data sets with 1 to 10 units with radon levels ≥4 pCi/L (Table 1) were selected for analysis using the Monte Carlo statistical method. Unlike other mathematically based statistical approaches, the Monte Carlo statistical method relies on repeated analysis of randomly selected data. from a 100% sampled complex at various sample densities. Success for each simulation is defined as finding at least one unit with elevated radon levels. In this statistical method, confidence in the overarching conclusion can be greatly enhanced by repeating the simulated screening hundreds or even thousands of times. For this study, each of the ten data sets was simulated 1,000 times. For each simulation, the data set was randomized three times before the fixed percentage of data was selected.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Methods of fabricating vacuum housings with hermetic solder seals using capillary solder wicks

Hermetically sealed electronic devices and methods for fabricating the hermetically sealed electronic devices are provided. The devices include a solder sealed vacuum housing. The solder seal is formed using a solder wick having an external solder reservoir. When the reservoir is filled with molten solder, the solder is drawn via capillary action into a precisely defined narrow gap between two components of the housing where it forms an airtight and vacuum-tight seal.

Frisch, Henry J.↗

Blending Behavioral Science and Physics-Based Models Inform Equitable Decarbonization Pathways in the US Housing Stock: Preprint

A just energy transition is an imperative of the Biden-Harris Administration, emphasizing the equitable distribution of benefits through energy-efficient and decarbonizing household technologies. Understanding the factors that increase a household's willingness to adopt these technologies helps policymakers implement more targeted and effective approaches. Our research addresses this by blending 550,000 housing stock types and energy simulation data with a nationally representative survey on residential technology adoption and decision-making (n=10,000). We identify energy equity gaps across tenure and income, highlighting disparities in energy burdens and insecurity. Findings show that households with prior modification experience are more willing to renovate, suggesting that small-scale retrofit programs could foster greater willingness. Energy secure but burdened homeowners are least willing to modify, highlighting the need to consider energy bill perceptions in policy design. Nearly half of US households that are energy burdened also face energy insecurity, with a significant gap in assistance for low-income households. We emphasize the need to understand household perceptions to improve policy. This research underscores the importance of understanding household behaviors to improve policy effectiveness, offering actionable insights for policymakers to promote equitable housing upgrades and advance a decarbonized future.

behavioral science↗

Greening the U.S. House of Representatives

The Greening the Capitol initiative was launched in March, 2007 with the threefold goals of making the U.S. House of Representatives: 1) carbon neutral within 18 months, 2) reducing energy use by 50percent in ten years, and 3) becoming a model of sustainable operations. We report on the recommendations to meet these goals, looking at the targets of opportunity at the Capitol Power Plant, the existing buildings, and the overall operations of the complex. Our findings have shown that these goals are achievable, and that through an integrated approach the savings in carbon and energy can be met. Specific examples include the lighting retrofits in the House offices, parking areas, and the Capitol dome; the retrofits to the HVAC systems and controls, including duct sealing, improving the efficiency of the energy and water use in the food service areas; and improved operations of the steam and chilled water distribution system. A key aspect has been better tracking and feedback to the building operators of the actual energy consumption. We report on the technical opportunities presented by these historic and symbolic buildings in becoming models of sustainability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EFFECT OF TEMPERATURE AND HUMIDITY ON FORMALDEHYDE EMISSIONS IN TEMPORARY HOUSING UNITS

The effect of temperature and humidity on formaldehyde emissions from samples collected from temporary housing units (THUs) was studied. The THUs were supplied by the U.S Federal Emergency Management Administration (FEMA) to families that lost their homes in Louisiana and Mississippi during the Hurricane Katrina and Rita disasters. Based on a previous study 1, 2, four of the composite wood surface materials that dominated contributions to indoor formaldehyde were selected to analyze the effects of temperature and humidity on the emission factors. Humidity equilibration experiments were carried out on two of the samples to determine how long the samples take to equilibrate with the surrounding environmental conditions. Small chamber experiments were then conducted to measure emission factors for the four surface materials at various temperature and humidity conditions. The samples were analyzed for formaldehyde via high performance liquid chromatography. The experiments showed that increases in temperature or humidity contributed to an increase in emission factors. A linear regression model was built using natural log of percentage relative humidity (RH) and inverse of temperature (in K) as predictor variables, and natural log of emission factors as the target variable. The coefficients of both inverse temperature and log relative humidity with log emission factor were found to be statistically significant for all the samples at the 95percent confidence level. This study should assist to retrospectively estimate indoor formaldehyde exposures of occupants of temporary housing units (THUs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Expert Meeting Report: Advanced Envelope Research for Factory Built Housing

This report provides information about the expert meeting on advanced envelope research for factory built housing, hosted by the ARIES Collaborative on October 11, 2011, in Phoenix, Arizona. The goals of this meeting were to provide a comprehensive solution to the use of three previously selected advanced alternatives for factory-built wall construction, assess each option focusing on majorissues relating to viability and commercial potential, and determine additional steps are required to reach this potential.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stud Walls With Continuous Exterior Insulation for Factory Built Housing: New York, New York (Fact Sheet), NREL (National Renewable Energy Laboratory)

The Advanced Envelope Research effort will provide factory homebuilders with high performance, cost-effective alternative envelope designs. In the near term, these technologies will play a central role in meeting stringent energy code requirements. For manufactured homes, the thermal requirements, last updated by statute in 1994, will move up to the more rigorous IECC 2012 levels in 2013, the requirements of which are consistent with site built and modular housing. This places added urgency on identifying envelope technologies that the industry can implement in the short timeframe. The primary goal of this research is to develop wall designs that meet the thermal requirements based on 2012 IECC standards. Given the affordable nature of manufactured homes, impact on first cost is a major consideration in developing the new envelope technologies. This work is part of a four-phase, multi-year effort. Phase 1 identified seven envelope technologies and provided a preliminary assessment of three selected methods for building high performance wall systems. Phase 2 focused on the development of viable product designs, manufacturing strategies, addressing code and structural issues, and cost analysis of the three selected options. An industry advisory committee helped critique and select the most viable solution to move further in the research - stud walls with continuous exterior insulation. Phase 3, the subject of the current report, focused on the design development of the selected wall concept and explored variations on the use of exterior foam insulation. The scope also included material selection, manufacturing and cost analysis, and prototyping and testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Envelope Research for Factory Built Housing, Phase 3 -- Design Development and Prototyping

The Advanced Envelope Research effort will provide factory homebuilders with high performance, cost-effective alternative envelope designs. In the near term, these technologies will play a central role in meeting stringent energy code requirements. For manufactured homes, the thermal requirements, last updated by statute in 1994, will move up to the more rigorous IECC 2012 levels in 2013, the requirements of which are consistent with site built and modular housing. This places added urgency on identifying envelope technologies that the industry can implement in the short timeframe. The primary goal of this research is to develop wall designs that meet the thermal requirements based on 2012 IECC standards. Given the affordable nature of manufactured homes, impact on first cost is a major consideration in developing the new envelope technologies. This work is part of a four-phase, multi-year effort. Phase 1 identified seven envelope technologies and provided a preliminary assessment of three selected methods for building high performance wall systems. Phase 2 focused on the development of viable product designs, manufacturing strategies, addressing code and structural issues, and cost analysis of the three selected options. An industry advisory committee helped critique and select the most viable solution to move further in the research -- stud walls with continuous exterior insulation. Phase 3, the subject of the current report, focused on the design development of the selected wall concept and explored variations on the use of exterior foam insulation. The scope also included material selection, manufacturing and cost analysis, and prototyping and testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Envelope Research for Factory Built Housing, Phase 3. Design Development and Prototyping

The Advanced Envelope Research effort will provide factory homebuilders with high performance, cost-effective alternative envelope designs. In the near term, these technologies will play a central role in meeting stringent energy code requirements. For manufactured homes, the thermal requirements, last updated by statute in 1994, will move up to the more rigorous IECC 2012 levels in 2013, the requirements of which are consistent with site built and modular housing. This places added urgency on identifying envelope technologies that the industry can implement in the short timeframe. The primary goal of this research is to develop wall designs that meet the thermal requirements based on 2012 IECC standards. Given the affordable nature of manufactured homes, impact on first cost is a major consideration in developing the new envelope technologies. This work is part of a four-phase, multi-year effort. Phase 1 identified seven envelope technologies and provided a preliminary assessment of three selected methods for building high performance wall systems. Phase 2 focused on the development of viable product designs, manufacturing strategies, addressing code and structural issues, and cost analysis of the three selected options. An industry advisory committee helped critique and select the most viable solution to move further in the research -- stud walls with continuous exterior insulation. Phase 3, the subject of the current report, focused on the design development of the selected wall concept and explored variations on the use of exterior foam insulation. The scope also included material selection, manufacturing and cost analysis, and prototyping and testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: Stud Walls with Continuous Exterior Insulation for Factory Built Housing

The Advanced Envelope Research effort will provide factory homebuilders with high performance, cost-effective alternative envelope designs. In the near term, these technologies will play a central role in meeting stringent energy code requirements. For manufactured homes, the thermal requirements, last updated by statute in 1994, will move up to the more rigorous IECC 2012 levels in 2013, the requirements of which are consistent with site built and modular housing. This places added urgency on identifying envelope technologies that the industry can implement in the short timeframe. The primary goal of this research is to develop wall designs that meet the thermal requirements based on 2012 IECC standards. Given the affordable nature of manufactured homes, impact on first cost is a major consideration in developing the new envelope technologies. This work is part of a four-phase, multi-year effort. Phase 1 identified seven envelope technologies and provided a preliminary assessment of three selected methods for building high performance wall systems. Phase 2 focused on the development of viable product designs, manufacturing strategies, addressing code and structural issues, and cost analysis of the three selected options. An industry advisory committee helped critique and select the most viable solution to move further in the research — stud walls with continuous exterior insulation. Phase 3, the subject of the current report, focused on the design development of the selected wall concept and explored variations on the use of exterior foam insulation. The scope also included material selection, manufacturing and cost analysis, and prototyping and testing.

Advanced envelope research↗

Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate

This report describes a research study that was conducted by the Building Science Corporation (BSC) Building America Research Team. BSC seeks to research and report on the field monitoring of the performance of in-situ supplemental dehumidification systems in low energy, high performance homes in a hot-humid climate. The purpose of this research project was to observe and compare the humidity control performance. Specifically, the study sought to compare the interior conditions and mechanical systems operation between two distinct groups of houses; homes with a supplemental dehumidifier installed in addition to HVAC system, and homes without any supplemental dehumidification. The subjects of the study were 10 single-family, new construction homes in New Orleans, LA.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Best Practices Series, Volume 9: Builders Challenge Guide to 40% Whole-House Energy Savings in the Hot-Dry and Mixed-Dry Climates

This best practices guide is the ninth in a series of guides for builders produced by the U.S. Department of Energy’s Building America Program. This guide book is a resource to help builders design and construct homes that are among the most energy-efficient available, while addressing issues such as building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the hot-dry and mixed-dry climates can achieve homes that have whole house energy savings of 40% over the Building America benchmark (a home built to mid-1990s building practices roughly equivalent to the 1993 Model Energy Code) with no added overall costs for consumers. These best practices are based on the results of research and demonstration projects conducted by Building America’s research teams. The guide includes information for managers, designers, marketers, site supervisors, and subcontractors, as well as case studies of builders who are successfully building homes that cut energy use by 40% in the hot-dry and mixed-dry climates.

54 ENVIRONMENTAL SCIENCES↗